DEUTZ EMR3 FAULT CODE 142 EEPROM error

By : R. Sauer

EEPROM stands for Electrically Erasable Programmable Read Only Memory. This memory type
is semi-permanent meaning that it can store information without the ECU being powered but it can
be erased and reprogrammed when a specific signal is received. This memory is used for storage of
operating hours and logistic data between shutdowns.
EEPROM significa elctricamente programable y borrable memoria de slo lectura. Este tipo de memoria es significado semipermanente que puede almacenar informacin sin la ECU recibe alimentacin pero se puede borrar y reprogramar cuando se recibe
una seal especfica. Esta memoria se utiliza para el almacenamiento de las horas de funcionamiento y datos logsticos entre
paradas.

When the engine is shutdown, the ECU remains active for approx. 10-20 seconds. During this
time, the logistic data is written to EEPROM so it is available the next time the ECU is booted. If
this process is interrupted, the logistic data will not be accurate and a fault code 142 will likely
occur.
Cuando el motor est apagado, la ECU se mantiene activa durante aprox. 10-20 segundos. Durante este tiempo, los datos de logstica
se escribe en EEPROM para que est disponible la prxima vez que la ECU se arranca. Si este proceso se interrumpe, los datos
logsticos no sern exactos y un cdigo de fallo probablemente se producirn 142.

The most common causes of this fault are


1. Main battery disconnect (E-stop) prior to completion of the EEPROM processes.
2. Incorrect wiring resulting in a loss of power to the ECU prior to completion of the
EEPROM processes.
3. Recent programming of the ECU.
Las causas ms comunes de esta falla son ...
1. Principal de desconexin de la batera (E-stop) antes de la finalizacin de los procesos de EEPROM.
2. Cableado incorrecto que resulta en una prdida de energa a la ECU antes de la finalizacin de los procesos de EEPROM.
3. Programacin reciente de la ECU.

The 142 fault code cannot be erased using normal means. This error must be reset by erasing the
EEPROM. A side effect of this erasure is the loss of engine operating hours stored in the
ECU. As a result, the following steps should be taken any time you are addressing this error.
1. Save a copy of the dataset using Overall Programming in Serdia.
2. Save a copy or error memory 1 and 2.
3. Record the current number of engine operating hours.
4. Use Serdia Tasks to reset the EEPROM.
5. Use Overall Programming to install the dataset saved earlier and enter the operating hours.
El cdigo 142 de fallo no se puede borrar utilizando los medios normales. Este error se debe restablecer mediante el borrado de la
EEPROM. Un efecto secundario de esta supresin es la prdida de horas de funcionamiento del motor almacenados en la ECU.
Como resultado de ello, los siguientes pasos deben tomarse en cualquier momento que se est dirigiendo este error.
1. Guarde una copia de la base de datos usando "Programacin general" en Serdia.
2. Guarde una copia o un error de memoria 1 y 2.
3. Registre el nmero actual de horas de funcionamiento del motor.
4. Utilice Tareas Serdia para restablecer la EEPROM.
5. Utilice Programacin general para instalar el conjunto de datos guardado anteriormente e introduzca las horas de operacin.

Using Serdia Tasks to reset the EEPROM

Entering the operating hours in Overall Programming

The illustrations above are linked to the guides for each task in FSDS.