EcoAir series

Smart Ventilation
For
Smart People

Range of capacity from


1000-6000m3

OHRU - C - Heat Recovery Units


Compact series

OzonAir products are designed to meet most


necessary customers requirements for small
and medium commercial and industrial building
requirements for fresh clean air, heating and
cooling.
This range is mainly designed for heavy and
continously use in different applications as
offices, restaurants, small production facilities
and other buildings wherefresh air is essential
and energy saving is important for smart
investors.
Energy and heat recovery is our mission.
We are designing and manufacturing
most delicate air to air Heat Recovery
Equipment ready for continuous work.
We have cared about saving energy before
global warming was even thought about and
before CO2 emissions became a topic of conversation. We work on this field for more than
15 years and this is our contribution to the world.
As Engineers, we believe we should use all resources as efficiently as possible.
Ozon operates in two ways.
First as a Supplier and Manufacturer of its own brand products and
secondly as a Manufacturer of OEM orders for several world wide known brands and
companies.
All products are designed and made in manufacturing plant in Macedonia.
Manufacturing the HVAC equipment and units is ISO 9001:2008 and ISO 14001:2004
certified.
OHRU-C units from EcoAir series or products conform with the protection requirements of Council
Directive 89/336/EEC relatingto electromagnetic compatibility.
Filter G3
Filter G3

Exhaust Air

Fresh Air
Heat Recovery
Exhanger

SIDE PANELS

Exhaust Air fan

Fresh Air Supply fan

In todays living ventilation and better indoor air quality (IAQ) is not a luxury anymore,
but need.
Fresh and clean air is crucial for good mental and physical condition for the people.
With fresh and clean air in the buildings kids can be more happier, students can think and
learn faster, workers can be more productive and all people can live healthier lives.
Fresh air keeps our health.
EcoAir OHRU - C series of products are designed for fresh air.
But, they can SAVE ENERGY during this process.

WHY DO WE NEED EcoAir OHRU - C SERIES OF HEAT RECOVERY


VENTILATION UNITS?
- To live healthier lives
- To save energy
- To reduce the CO2 emission in the air
- To recover the energy for heating and cooling
- To remove or decrease the odors
- To remove contaminants from the air
Ventilation is also required to remove moisture from swimming pools and changing rooms.
As the OHRU-C combines the ability to supply and exhaust air within one unit, it is ideal for
todays buildings, which have double or triple glazing and are much more airtight.
The OHRU-C was specifically designed to meet the needs of modern buildings and at the same
time save energy and reduce CO2 emissions.
The OHRU-C features EUROVENT certified recuperators for air to air energy recovery and
are 100% reliable.

OHRU - C Heat Recovery Unit for best ventilation


Efficiency may be as high as 70% for certain applications where indoor moisture is high.
Ventilation is even more important than ever and a successful building needs to keep the
occupants comfortable.A good ventilation system with heat recovery is the best way to
achieve this goal.
The Series OHRU - C are designed to handle air volumes up to 6000 m3/h. Each unit handles
both supply and exhaust air and incorporates a EUROVENT certified heat recovery core.
The heat recuperator will extract energy (hot or cold) from the exhaust air and transfer it to
the incoming fresh air. When used in conjunction with air conditioning systems, energy will be
saved in both heating and cooling modes.

CONSTRUCTION
HEAT RECUPERATOR
All 5 sizes of OHRU-C incorporate EUROVENT certified aluminum plate heat recuperators.
The efficiencies vary for each size, but will be approximately within the ranges from 50%to
60%.Efficiencies may rise up to 80% for high temperature and humid applications such as
swimming pools, changing rooms or similar.Recuperators are available with epoxy coating
for coastal and swimming pool applications.
FANS
All fans are direct drive powered and specially selected for efficient operation. All of the fans
used for the OHRU-C series are ideal for speed regulation and a full range of matched speed
controllers are available.On all models, fans are wired to externally mounted isolators.
SPECIFIC FAN POWER
OHRU-C units are fitted with two high quality fans of latest design. None of the fans have belts
or pulleys, which cause transmission losses and lower the overall fan set efficiency. All fans
have been checked for Specific Fan Power (SF) and are lower than the requirement, stated
in Part L2 of the Building Regulations, of 2.0 watts/l/s.
MOTORS
Fan motors are totally enclosed and suitable for speed control. All fans are with built in
anti-vibration mountings, but in accordance with best practice, we still recommend the use
of anti vibration mounts and flexible connections.
PANELS
Panels are 1 mm thickness with normally insulated model with PE foam 6 mm thickness.
The skin is made of galvanized sheet metal.
FILTERS
Standard supply and exhaust air filters are EU4 (G4) grade according to EN 779 disposable
pleated panel. Manometers are available as an option.
DRAIN
A drain pane connection is fitted to the exhaust air side of the casing to allow any condensate
to drain away. This connection should be trapped and piped up with an air break before conn ection to any common drain lines. The depth of the trap should be equal to the suction pressure plus 25mm.

CONDENSATION
The efficiency of a recuperator depends on many variables and as our recuperator operate
with high efficiencies, condensation is likely to occur in the exhaust air stream as dew point
conditions are reached. For this reason, all of our OHRU-C Units are fitted with drain trays as
standard. All OHRU-C efficiencies are computed using design conditions of: -15C/85% RH
and 21C/50% RH. OHRU-C use Eurovent Certified Recuperators. Independent Laboratory
Tests confirm actual performance against the software model.

PLUG AND PLAY INSTALLATION


ON SITE CHANGING OF CONNECTION SIDES
ler without knowledge and skills can
All OHRU-C units are specifically designed so even instal
change and rotated connections for inlet or exhaust in every possible direction with simple
operation. One side changing can take approximately 5min. For any special request or
connections possibility please discuss with our engineers.

CONTROL PANEL
MANUAL BASE UNIT CONTROLER
OHRU-C units can be simply controlled with manual controller. It controls on/off function of the
unit in base version.

Placing an order
OHRU-C-1000-EU4-IV-01-SS-f-DC

OHRU-C-1000-EU4-IV-01-SS-f-DC
Optional controller:
NC - no controller
SC - standard controller
DC - digital controller

OzonAir
brand
Heat Recovery
unit

Optional flexible duct connection:


Compact
Optional inner skin:
SS-stainless steel
EC-epoxy coating

Type:
1000
2000
3000
4000
6000

Air filter:
G3, EU4
Type of mounting
IVindoor vertical unit
IHindoor horizontal unit

First number: 0-round duct connection


1-square duct connection
Second number: 1 side configuration of duct connections

OzonAir OHRU - C series covers an airflow range


from 1000 up to 6000 m3/h

OHRU - C - GENERAL TECHNICAL DATA

OzonAir OHRU - C Technical Data For Standard Models


Maximum Curent A
220V/50Hz 380V/50Hz

Type

Volume
m3/h

Pressure* Pa

Efficiency - %

Fan Speed

Motor Power
W

1000

1000

110

51,1

2x147

2x1,5

IP44

2000

2000

135

51,2

2x350

2x3,1

IP55

3000

3000

210

50,2

2x550

2x5,9

4000

4000

210

55,0

2x600

2x6,6

6000

6000

210

54,3

2x1350

2x10,8

Protection

IP10
IP55
IP20

OHRU - C - TECHNICAL DATA FOR RECOVERY UNIT


OHRU - C Technical Data For The Recovery Unit
Thermal recovery
unit for OHRU
Efficiency - %
Recovery thermal
power kW
Renewal air outlet
temperature C

1000

2000

3000

4000

6000

51,1

51,2

50,2

55,0

54,3

6,1

12,0

17,6

25,8

38,2

6,2

6,4

6,7

5,6

5,7

Values referring to the following conditions: Tout. air.=-15C; Tin=20C; R.H.in = 50%; Nominal airflow

OHRU - C - TECHNICAL DATA FOR NOISE


OHRU - C Noise Levels
OHRU type
Speed
OHRU 1000
OHRU 2000
OHRU 3000
OHRU 4000
OHRU 6000

Noise to free field at 1m distance

1
36
46
49
41
42

2
39
48
50
43
50

3
45
48
52
46
54

Sound level (Lp) taken in a resonance chambre following ISO 3741 standard

OHRU - C - GENERAL PERFORMANCE DATA FOR RECOVERY UNIT

OHRU - C series Recovery Thermal Yeld


OHRU

Air volume
m/h

Indoor air
temperature - C

Indoor relative
Outdoor air
humidity - % temperature - C
Winter operation

50
1000

1000

20
60

50
2000

2000

20
60

50
3000

3000

20
60

50
4000

4000

20
60

50
6000

6000

20
60

-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7
-15
-7
0
7

Outdoor
relative
humidity - %

Air after
recovery - C

Efficiency - %

Power kW\

80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50
80
70
60
50

6,2
8,9
11,4
14,3
7,2
9,6
11,8
14,3
6,4
9,1
11,5
14,4
7,4
9,8
12,0
14,4
6,7
9,3
11,7
14,5
7,7
10,0
12,1
14,5
5,6
8,4
10,9
13,9
6,6
9,2
11,5
14,0
5,7
8,5
11,0
14,0
6,7
9,3
11,6
14,1

51,1
49,5
45,9
44,2
55,8
54,0
50,2
45,0
51,2
48,5
45,0
43,3
54,7
52,9
49,2
44,1
50,2
47,7
43,9
42,3
53,5
51,8
48,0
43,1
55,0
52,3
48,8
46,6
58,7
56,7
53,0
47,8
54,3
51,6
48,1
46,0
58,0
56,0
52,3
47,1

6,1
4,5
3,1
1,9
6,5
4,9
3,4
2,0
12,0
8,8
6,0
3,8
12,8
9,6
6,6
3,8
17,6
12,8
8,8
5,5
18,8
14,0
9,6
5,6
25,8
18,9
13,1
8,1
27,5
20,5
14,2
8,3
38,2
28,0
19,3
12,0
40,7
30,4
21,0
12,3

OHRU - C - DIMENSIONS

OzonAir OHRU Dimensions


OHRU

1000
2000
3000
4000
6000

1020
1200
1375
1475
1675

455
526
610
675
807

860
940
1075
1115
1400

232
232
332
331
373

208
262
290
294
404

99
119
103
113
164

300
350
400
500
600

300
350
400
500
600

65
60
69
29
50

124
132
160
191
202

78
88
105
88
104

Duct Connection

Round
350
400
450
550
610

Square
300x300
350x350
400x400
500x500
600x600

Weight
85
110
130
170
250

ENVIRONMENTAL POLICY
Together we work for Green planet
Ozon Company is committed to preserve environment through
implementation of environment protection policies. We strive to:
Comply with all applicable environmental legal and other environmental
requirements.
Keep the natural resources as much as possible.
Improve effectively the environmental management system.
Reduce the environmental pollution, Recycle, Recover and Re-use of natural
resources.
We are a Green Company and we aim to prevent environmental pollution by
practicing best environmental management system for a healthier global
world.
We all should give our maximum efforts to make things better.
So, can we make a difference?
Yes.
So, can You make a difference?
Yes.
No matter where you live, Europe or China, the USA or Macedonia, Japan or
Argentina, we must work together to protect our world.
The world we live in, the world we build and the world that we will leave for
next generation. We all must think about our children and their future.
We must take steps together to make Green and Healthier future.
We, in Ozon have already started and make first steps.
Join us for better world for all.

Post address: Zagrebska 45, 1000 Skopje, Macedonia


Head offices: Varsavska br.1, Skopje,
Tel/Fax: + 389 2 309 12 12; 309 12 11;
e-mail: info@ozon.com.mk
www.ozon.com.mk

This document is provided "as it is" with our full carefulness. Ozon may change, revise and delete the contents of
this catalogue without prior notification to anyone. Ozon will not be responsible for any damage, and loss that may
arise from the use of this catalogue.
OZON", "OzonAir" and "EcoAir", logo, product name, etc., used in this document are "trademark" registered and
owned by OZON dooel Macedonia and its affiliate Ozon USA. User shall contact us by writing prior to use any of
Ozon logo marks.

Das könnte Ihnen auch gefallen