HIGHMAST LIGHTING NOTES:

DESIGN CRITERIA:

1.

1.

Designed in accordance with the FDOT Structures Manual.

2.

Poles are designed to support the following:

High Mast materials:


a. Pole: ASTM A1011 Grade 50, 55, 60 or 65 (Less than ") or ASTM A572 Grade 50,
55, 60, or 65 (" and over) or ASTM A595 Grade A (55 ksi yield) or Grade B (60
ksi yield).

a.

(1) cylindrical head assembly with a maximum effective projected

b.

(8) cylindrical luminaires with a maximum effective projected area

area of 6 SF (Cd=1) and 340 lbs (Max).


b. Steel Plates: ASTM A709 Grade 36 or ASTM A36

of 3.0 SF (Cd=0.5) and 77 lbs. each.


c. Weld Metal: E70XX
3.
d. Anchor Bolts: ASTM F1554 Grade 55 with ASTM A563, Grade A heavy-hex nuts and
plate washer.

Foundation design based upon the following soil criteria:


Classification

= Cohesionless (Fine Sand)

Friction Angle

= 30 Degrees (30)

Unit Weight

50 pcf (assumed saturated)

e. Handhole: ASTM A709 Grade 36 or ASTM A36 Frame with ASTM A36 cover.
Only in cases where the Designer considers the soil types at the
f. Caps: ASTM A1011 Grade 50, 55, 60 or 65 or ASTM B209.

specific site location to be of lesser strength properties should an


analysis be required. Auger borings, SPT borings or CPT soundings may

g. Nut Covers: ASTM B26 (319-F)

be utilized as needed to verify the assumed soil properties, and at


relatively uniform sites, a single boring or sounding may cover several

h.

Stainless Steel Screws:AISI Type 316

foundations. Furthermore, borings in the area that were performed for


other purposes may be used to confirm the assumed soil properties.

2.

Reinforcing steel: ASTM A615, Grade 60.

3.

Concrete: Class IV (Drilled Shaft) with a minimum 4,000 psi compressive strength at

4.

Foundation applies only to slopes of 1:4 or flatter. Provide a minimum

5.

Poles are designed for 6 mil galvanization thickness.

24" shaft projection on the high side.

28 days for all environmental classifications.


4.

Welding: American Welding Society Structural Welding Code (Steel)

ANSI/AWS DI.1

Current edition).
5.

Galvanization:
a. Nuts, Bolts, Washers and Threaded Bars/Studs: ASTM F2329.
b. Other items (Including Pole): ASTM A123

6.

Hole diameters for anchor bolts: not greater than the bolt diameter plus ".

7.

Poles: Tapered with the diameter changing at a rate of 0.14 inch per foot with a
minimum 16-sided pole shaft and maximum of two longitudinal seam welds. Circumferentially
welded pole shaft butt splices and laminated pole shafts are not permitted.
Longitudinal seam welds within 6 inches of pole to base must be complete penetration
welds. Longitudinal seam welds at telescopic field joints must be complete penetration
welds for the splice length plus 6 inches.

C:
\d\projects\standards\roadway\17500-s\17502-01.
dgn

8.

One hundred percent of full-penetration groove welds and a random 25 percent of


partial penetration groove welds shall be inspected. Full-penetration groove weld
inspection shall be performed by nondestructive methods of radiography or
ultrasonics.

9.

Furnish each pole with a 2"x4" (Max.) aluminum identification tag. Submit details for
approval. Secure to pole with 0.124" stainless steel rivets or screws. Locate
identification tag on the inside of pole and visible from handhole. Include the
following information: Financial Project ID, Pole Mounting Height, Manufacturers Name, Fy of
Steel, and Base Wall Thickness.

10. Verify CSL access tubes will not interfere with anchor bolt installation before
excavating the shaft. When CSL access tube locations conflict with anchor bolt
locations, move the CSL access tube location two inches along the inner
circumference of the reinforcing cage. Notify the Engineer before excavating the
shaft if the CSL access tube locations cannot be moved out of conflict with anchor bolt

12/30/2011

11:
49:
02 AM

rd960rh

locations.

LAST
REVISION

01/01/12

REVISIO N

STANDARD POLE DESIGN NOTES


DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

HIGHMAST LIGHTING

NO.

17502

SHEET
NO.

Luminaire Head

Luminaires

Length Section (
1)

Pole Design Table*


Section 1 (Top)
Design
Wind
Speed

Joints

Splice Length (
1)

Telescopic Field

(8 Maximum)

110 mph

Round or 16-Sided
Pole (Faces not
shown for clarity)

(see Note 9)
Handhole Door

Section 3

Minimum
Minimum
Minimum
Tip Dia. Base Dia. Length WallTh.
Tip Dia. Base Dia. Length WallTh.
Tip Dia. Base Dia.
Splice L.
Splice L.
Splice L.

80

42-0"

0.250"

2-0"

5.313"

11.219"

40-0"

0.250"

---

100

24-6"

0.179"

2-0"

120

44-9"

0.250"

2-0"

10.375"

16.000"

---

---

---

---

---

6.406"

9.844"

40-0"

0.250"

6.250"

12.531"

40-0"

0.250"

2-6"

9.188"

14.781"

40-0"

0.250"

---

13.875"

19.500"

2-9"

11.688"

17.313"

40-0"

0.313"

---

16.375"

22.000"

80

42-0"

0.250"

2-0"

5.281"

11.188"

40-0"

0.313"

---

10.375"

16.000"

---

---

---

---

---

100

24-6"

0.179"

2-0"

6.906"

10.344"

40-0"

0.250"

2-6"

9.656"

15.281"

40-0"

0.313"

---

14.375"

20.000"

120

45-6"

0.250"

2-6"

9.250"

15.625"

40-0"

0.250"

3-0"

14.719"

20.344"

40-0"

0.313"

---

19.375"

25.000"

80

42-3"

0.250"

2-3"

7.281"

13.219"

40-0"

0.313"

---

12.375"

18.000"

---

---

---

---

---

100

24-6"

0.250"

2-0"

8.188"

11.625"

40-0"

0.313"

2-6"

10.781"

16.406"

40-0"

0.375"

---

15.375"

21.000"

120

46-6"

0.250"

3-0"

12.406"

18.938"

40-0"

0.313"

3-6"

17.938"

23.563"

40-0"

0.375"

---

22.375"

28.000"

* Diameter Measured Flat to Flat

Joints

Splice Length (
2)

Length Section (
n)

Identification Tag

150 mph

Length WallTh.

Section 2

Base Plate and Bolts Design Table


Telescopic Field

C:
\d\projects\standards\roadway\17500-s\17502-02.
dgn

0.
14 in/ft Taper, Typ.

Length Section (
2)

Overall H eight

130 mph

Pole Overall
Height (ft)

Design
Wind
Speed

Pole Overall
Height (ft)

Base Plate
Diameter

Base Plate
Thickness

Bolt
Circle

No.
Bolts

Bolt
Diameter

Bolt
Embedment

80

30.0"

2.500"

23.0"

1.75"

38"

110 mph

100

33.5"

2.500"

26.5"

1.75"

42"

120

36.0"

2.750"

29.0"

1.75"

45"

130 mph

150 mph
Base Plate

Shaft Design Table

80

30.0"

2.500"

23.0"

1.75"

43"

100

34.0"

2.750"

27.0"

1.75"

50"

120

41.0"

3.250"

33.0"

2.00"

52"

80

32.0"

2.750"

25.0"

1.75"

49"

100

37.0"

3.000"

29.0"

2.00"

53"

120

46.0"

3.250"

37.0"

10

2.25"

57"

Design
Wind
Speed

Pole Overall
Height (ft)
80

110 mph

100

130 mph

150 mph

Shaft
Diameter

Shaft
Length

Longitudinal
Reinforcement

4-0"

13-0"

14 - # 11

4-0"

15-0"

14 - # 11

120

4-6"

16-0"

16 - # 11
14 - # 11

80

4-0"

14-0"

100

4-0"

16-0"

14 - # 11

120

4-6"

18-0"

16 - # 11

80

4-0"

16-0"

14 - # 11

100

4-6"

17-0"

16 - # 11

120

5-0"

20-0"

18 - # 11

rd960rh

Wire screen
2-0" Min.

to highmasts
on Fill

Fill H eight

Line adjacent

25M axim um

Natural Ground

12/30/2011

11:
49:
03 AM

(Max. Slope)
1

Drilled
Shaft

LAST
REVISION

01/01/09

REVISIO N

ELEVATION

POLE DESIGN TABLES

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

HIGHMAST LIGHTING

NO.

17502

SHEET
NO.

10"

11"

Shaft Diameter
Base Plate
4"

p
a
"L
2

2
)
.
n
Mi
(

Diameter
Handhole Ring

Bolt Circle

1
2"

Center of

x 6" Ring

1
4"

#5 Tie Bars

Drilled Shaft

Thick

Handhole
Door
Padlock Tab

CSL tube (Typ.)

1
4"

1
-9"

10"

1
-8"

Full Pen.

Padlock Tab
6"

Hinge Mount
(Typ.)

Edge of

Equally Spaced.

Base Plate
Longitudinal
Reinforcement
Eq. Spaced
(See Table For
Reinforcement)

(See Table)

Center of Drilled

Base

Partial Penetration

6" Cover

Joint

(Typ.)

"

"

3 4

=
R

Diameter (Pole)

Shaft, Base

4"

Anchor Bolts

3 4

Full Pen.

=
R

Plate, and Pole

FOUNDATION PLAN

(T = Wall Thickness)

SECTION A-A

HANDHOLE RING

(Anchor Bolts and Conduits Not Shown)

HANDHOLE DOOR
2 X Bolt Diameter

" Wall Thk. +


45 deg.

x Wall Thk.

Bolt Circle

Anchor Bolts
Base Plate

Shaft Diameter

Double Nuts, Top Nut may be half

Diameter

Nut Cover (not shown) for each bolt

1
4"

1
-8"

Base Plate

(
Top)

4" Cover

"

6 Sp. @

Ring
C:
\d\projects\standards\roadway\17500-s\17502-03.
dgn

1" Min.

4"

Handhole

Silicone Caulk

Plate Washer

5"

M in.

2
-0"

3
8"

3"X " Backing

height Jam Nut. Provide individual

1" x 1" Chamfer

Base Plate

Thickness

Opening

(1) Bolt Diameter

Handhole

(Max.)

Door

Anchor Bolt

Drilled Shaft

Leveling

Wire screen

Finished Grade
1: 4 Max Slope

Tip Diameters or
Base Diameters
measured flat to flat

SECTION C-C

Center of Arm

Sp. @

M in.

Bolt Em bedm ent

2
-0"

see Spec. 649-6

1
-6" (
M ax.
)

12"

Base Diameter

rd960rh

Shaft Length

Nuts

Inside Radius

Double Nuts (Typ.)

Wall

measure center

Thickness

to flat

Typ. (see Note)

12/30/2011

BASE PLATE AND ANCHORAGE ELEVATION


(Conduits Not Shown)

Break Radius Typical

Spacing

Drilled Shaft

# 5 Ties

11:
49:
04 AM

1"

7"

0.6 x Wall Thickness

6" Cover

NOTE:

Min. Break Radius

Longitudinal seam welds within six inches of

= 0.25 x (Inside

circumferential welds shall be complete penetration

Radius)

welds. Longitudinal seam welds at telescopic field


splices shall be complete penetration welds for

(Typ.)

the splice length plus six inches.

SECTION B-B
(Conduits Not Shown)

SECTION E-E

LAST
REVISION

07/01/10

REVISIO N

POLE FOUNDATION
DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

HIGHMAST LIGHTING

NO.

17502

SHEET
NO.

Twistlock disconnect

Schedule 40 PVC conduit. Circuit conductors


and conduit size as shown In plans. (Typical).
Schedule 40
PVC conduit
with 4/0 Cu
Pigtail Cord W/Female Receptacle

bare ground
wire.

Male Inlet

Circuit Breaker Panel Box with Surge


Interrod distances must

Arrester mounted to Top of Circuit Breaker

be a minimum of 10.

Panel Box for easy access. Service entrance


fittings shall be used on all conductors entering
Circuit Breaker Panel Box.

Attach Copper Lugs (Two-Hole,


Straight Tongue, Two-Barrel)
to winch support plate to

#6 ground

accommodate 2-4/0 and 2-#6


conductors for grounding.

4/0 ground

Schedule 80
PVC conduit

Wire Screen
see Spec. 649-6

4/0 AWG stranded


C:
\d\projects\standards\roadway\17500-s\17502-04.
dgn

CU bare ground
wire connected to
grounding lug
inside pole.

#6 Bonding Ground

expansion

2
-6"

3
8"

joint (sealed)

12" bed of pearock or


crushed stone for drainage.

U L approved ground rod

5
8"

diameter 20 long copper clad with


approved ground connection.

4/0 Cu bare
ground wire
connected to
Minimum of (6)

5
8"

x 20

rd960rh

approved ground rods.

Schedule 40

grounding field

PVC conduit

or array.

with 4/0 Cu
bare ground

Schedule 40 PVC conduit. Circuit conductors

11:
49:
04 AM

wire.

and conduit size as shown in plans. (Typical).

NOTES:
1.

At all pull boxes and pole bases, ends of conduit shall be sealed in accordance with Section 630 of the

12/30/2011

Standard Specifications For Road And Bridge Construction.


2.

Slabs to be placed around all Poles and Pull Boxes.

3.

For Pull Boxes between Poles refer to Index 17500.

LAST
REVISION

01/01/12

REVISIO N

WIRING DETAILS
DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

HIGHMAST LIGHTING

NO.

17502

SHEET
NO.

To
The contractors attention is directed to those plan

Luminaire

sheets detailing the mounting of luminaires at the


pole top.

Particular attention is directed to


Ground to Winch

alignment of luminaire light distributions. Special


Cover

attention must be exercised in the physical alignment

Support Plate

of these luminaires to ensure that the approved


photometric layout is physically produced at each

Circuit Panel

Equipment

lighting standard in the field. A marking shall be

SPD

Ground Conductor

placed on the external face of the refractor to

Breaker

allow visual inspection of alignment. The marking


shall correspond to the 0 axis of the refractor.

Head plate

See legend for number

4/0 Ground

of luminaires, lamp wattage


and light distribution.
Lift cable sheaves
Conduit
Luminaire support ring
Grounding Array

480V Phase

#6 Bonding Ground

to Phase
Lift cables (2 minimum)

Pole cable

20 Ground

& sheaves

Pull Box

Rod

2" slip fitter


Cover

HI
GH MAST POL
E WI
RI
NG DI
AGRAM

Lift
cables
Power Cable Terminator

600 Volt rated Pole Cable.

Luminaires

Size of conductors to be determined


by luminaire load.

All hardware for mounting heavy duty


drill to pole shall be Stainless Steel.

Male Inlet

1
2"

C:
\d\projects\standards\roadway\17500-s\17502-05.
dgn

2" Slip-fitter Assembly

Slip clutch
Step-down transformer provided with

(equally spaced around ring)

120V. grounded receptacle for electric


drill & receptacle for supply cable.
Power Cord

(see schematic)

With Male Inlet

25 minimum remote control cable


same as Pole Cable.

ON

OFF

Remote
control
switch
Covered receptacle to power
luminaires when in the lowered

Receptacle

position with Male Inlet.

Pole Cable
High mast pole

Winch cable

off
on

Female Plug

Circuit Breaker Cable


rd960rh

heavy duty reversible or 1 HP

Portable Motor(1) per project.

Luminaire support ring

with Female Plug

gnd.
Remote control switch
Positive drive reversible winch

11:
49:
05 AM

Hand hole
Winch
Supply cable receptacle
Lock nuts

A surge protector shall


600 Volt rated Circuit Breaker Cable.

be located in the pole with


the circuit breaker. The surge

Size of conductors to be determined

SCHEMATI
C OF REMOTE AUXI
L
I
ARY POWER UNI
T

by luminaire load.

protector shall be mounted


12/30/2011

at the front near hand hole


for easy access.

LAST
REVISION

01/01/12

REVISIO N

Base plate

Base plate

LOWERING DETAILS

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

HIGHMAST LIGHTING

NO.

17502

SHEET
NO.

10-0"

2-0"

Varies

Varies

NOTES:
1.

Use compacted select material in accordance with Index 505.

2.

Concrete shall be Class NS with a minimum strength at 28 days of fc=2.5 ksi.

3.

Outside edge of slab shall be cast against formwork.

4.

The pull box shown is 13" x 24"; others approved under

10
-0"

Pull Box

Slabs to be placed around all Poles and Pull Boxes. In urban areas or where
space is limited slab dimensions may be adjusted as shown in the plans.

6.

12"

Section 635 of the Standard Specifications may be used.


5.

13"
Typ.

Concrete for slabs around poles and pull boxes shall be included

7.

The

1
2"

1
2"

thick expansion joint between the pole shaft and slab shall

in the price of pole or pull box.


Expansion

Joint (Sealed)

be sealed with a hot poured elastic joint sealer.

C:
\d\projects\standards\roadway\17500-s\17502-06.
dgn

SLAB DIMENSIONS

1
2"

Expansion Joint (Sealed)

SHAFT LOCATION

6"

L BOX
PUL
ON
OCATI
L

6"

rd960rh

4" SELECT MATERIAL

12/30/2011

11:
49:
06 AM

SECTION C-C

REVISION

01/01/12

REVISIO N

SLAB DETAILS
LAST

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

HIGHMAST LIGHTING

NO.

17502

SHEET
NO.