Sie sind auf Seite 1von 53

NEC

NECITR-YTC
ART-MARI04

..

"

11(1; t~ t~T

PASOLINK PLUS SOFTWARE VER 4.23.xxx

,\

NEC International Training, Ltd.


Yokohama Training Center
,

n~t

V02

NEC

PNMT-GENERAL
.

NECITR-YTC
ART-MAR/04 V02

PASO LINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF


A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK
MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT
HAUL RADIO TRANSMISSION NETWORK.
PNMT IS DESIGNED AS AN ONSITE MAINTENANCE
TOOL TO BE USED BY THE FIELD ENGINEERS AND
TECHNICIANS. IT CONNECTS DIRECTLY TO THE
PNMT PORT OF THE PASOLINK IOU. PNMT CAN BE
USED TO MONITOR LOCAL / REMOTE EQUIPMENT
STATUS AND PROVIQES CONTROL CAPABILITIES
SIMILAR TO THOSE AVAILABLE IN PNMS.
PNMT IS ALSO USED TO DOWN LOAD SYSTEM AND
CONFIGURATION FILES TO THE NE AND UPGRADE
THE SOFTWARE IN THE IOU

WHEN CONNECTED TO AN IOU. PNMT . CAN


MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT
ANY REMOTE NETWORK ELEMENT UNDER THE
CONTROL OF THE CENTRAL PM.

PNMT

NEC

FUNC IONS

NECITR-YTC
ART-MAR/04 V02

II

MICROSOFT WINDOWS 98/NT/2000/XP WORKSTATION GRAPHICAL USER INTERFACE

II

ONE HOP LINK DISPLAY ON THE PNMT SCREEN

II

COMMUNICATE WITH REMOTE NEs ON THE SAME NETWORK

II

COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE NEs

II

TRANSMISSION

II

SEVERAL LEVELS OF LOGIN I LOGOUT

II

EVENT LOGGING WINDOW

II

PERFORMANCE MONITORING FUNCTION WINDOW

II

LOCAL I REMOTE EQUIPMENT CONTROL FUNCTION

III!I

LOCAL/REMOTE PM CONFIGURATION MANAGEMENT

II

LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE

EQUIPMENT CONTROL VIA LOCAL AND REMOTE CTRL MODULES

PNMT

r"
i

NEC

PNMT COMMUNICATION INTERFACE

NECITR- YTC
ART-MAR/04 V02

COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :
VIA THE PNMT PORT OF THE LOCAL PASOLINK EQUIPMENT
VIA THE DSC TO A REMOTE PASOLINK EQUIPMENT
PNMT PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND
CONSISTS OF A RJ45 CONNECTOR. PNMT PORT CONNECT THE PM
CTRL MODULE IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT
COMMUNICATION PORT OF THE PNMT COMPUTER.
PROPERTIES OF THE PNMT PORT ARE AS FOllOWS:

3 METERS

PORT CONFIGURATION

RS-232

CONNECTOR TYPE

RJ45

BITS PER SECOND RATE

1200 TO 19200 Default(19200)


PC (PIHAT,I

PAS()l INI(~
PNLAT po II.

<>

1
.2
J.
4
S

C,D
D;D
!;:);D
DSFi:
GilD

6-

DT'Fi:
C1l:i
RTI;

7
:a.

PNMTPORT

PNMT

NEC
HARDWARE/SOFTWARE CONFIGURATION
II

NECITR-YTC
ART-MAR/04 V02

RECOMMENDED PNMT MOBILE PC CONFIGURATION


LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE)
CPU:
PENTIUM-II 500 MHz OR HIGHER
RAM:
128 MB OR MORE
HOD:
5 GB OR MORE
FDD:
3.5INCH
CD-ROM: 8 x OR HIGHER
INTEGRATED SOUND CARD AND SPEAKER

II

SOFTWARE CONFIGURATION
ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD DISK
AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED
WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS
OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM

II

OPERATING SYSTEM
WINDOWS
WINDOWS
WINDOWS
WINDOWS

II

98 (ENGLISH VERSION) OR
NT WORKSTATION Ver 4.0 (ENGLISH VERSION)
2000 (ENGLISH VERSION)
XP (ENGLISH VERSION)

APPLICATION PROGRAM
NEC PNMT SOFTWARE
PNMT

NEC

START UP
,

NECITR-YTC
ART-MAR/04 V02

CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU PNMT PORT USING A RS232C CABLE
DOUBLE CLICK ON THE PNMT SHORTCUT
ICON ON THE DESKTOP OR CLICK ON
STARTPROGRAMPNMTPNMT

Coneel

Selected

PNMT PROGRAM STARTUP AND


TRIES TO GET CONNECTED TO THE
PASOLINK EQUIPMENT

k EI_nI

Acquiring data. Please wait...


MTPC1)( Power
TX Frequency
RX FreauencY
Frame 10
1)( Powefcohlrol

MainINTFC

AFTER CONNECTING TO THE PASOLINK


EQUIPMENT TRIES TO ACQUIRE DATA FROM
THE LOCAL EQUIPMENT AND THE REMOTE
EQUIPMENT TO DISPLAY ON THE LINK
SUMMARY WINDOW

PNMT

ALS
MAINT

'

"2%jEi
23010.750 MHz
22002.750 MHz
1
ATPC
STM.1(Optical)
Enable
OFF

PMC IV,,,,,,,

NEC
NECITR-YTC
ART-MAR/04 V02

SHUT DOWN
IF YOU HAVE NOT LOGIN FIRST THE
EXIT MENU CANNOT BE SELECTED.

TO EXIT THE PNMT PROGRAM


CLICK ON EXIT IN THE SYSTEM
DROPDOWN MENU AND CLICK YES.

"

IN THE DIALOG BOX


THAT OPENS CLICK
YES

Not Connected

Not Connected

THE SCREEN INDICATES NOW PNMT


SHUTDOWN. IT WILL TAKE FEW MINUTES TO
SHUTDOWN

PNMT

NEC
NECITR-YTC
ART-MAR/04 V02

PNMT MAIN SCREEN


PNMT MAIN SCREEN IS SPLIT IN TO TWO TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.
PNMT WINDOW
MENU BAR
COMMON TOOL BAR
LINK SUMMARY WINDOW
NE-SPECIFIC MENU ITEMS

--

--.--.---.---

Selected Network Element

I"

jg]

LinkPerformanceMonitor

Opposite Network Element


. '.'

. ..

L~ ConfigUrat~~~.~J.~:ve~~Lo~..L~.~i~~,~~~~~~~~~:~~~it~~
. ..
C..:

~iQ~QOL---"""

''''''-'

r::.AUX8l
BLOCK DIAGRAM
L

NE-SPECIFIC DATA

-15 dB

MTPCTX PowerB
23290.000 MHz
TX Frequency
RX Frequency., 22282.000 MHz
Frame 10' .
1

22282.000 MHz
23290.000 MHz

=j

CLICK ON THE ARROW


ICONS IN THE MIDDLE OF
THE SCREEN TO EXPAND
THE LEFT OR RIGHT DATA
WINDOW. CLICKING ON THE
BLOCK WILL RETURN THE
ORIGINAL SPLIT SCREEN.

TAB SELECTION FOR


OTHER EQUIPMENT
VIEWS

ATPC

MTPC
10/100BASE-T

OFF

OFF

""'.&"~

Ready
SELECTED

PNMT

NE

OPPOSITE

NE

LOGIN INFORMATION

NEC

PNMT MAIN SCREEN

NECITR-YTC
ART -MAR/04 V02

COMMON MENU BAR


COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEM
HAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE.
COMMON TOOL BAR
COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS
LINKSUMMARYWINPQW
LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP).
THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE

WINDOWOFTHE LINKSUMMARYWINDOW.IT SHOWSGRAPHICALLYTHE STATUSOFTHE PASOLINKEQUIPMENTIN ~


BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS
WINDOW
N~.SPE;GIFJGPAIA;
NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE
WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM.
NE SPECIFIC MENU ITEMS:
EQUIPMENT CONFIGURATION
EVENT LOG
LINK PERFORMANCE MONITOR

-r--

c=

EQUIPMENT SETUP
PROVISIONING
MAINTENANCE

TAB SELECTION
DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX lIP
CTRL AND VERSION) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.

NE.!:3LQGKPJAGRAM;
STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX lIP AND CTRL) ARE SHOWN IN THE BLOCK
DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE
DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,

PNMT

NEC

PNMT WINDOW MENU ITEMS

NECITR-YTC
ART-MAR/04 V02

REFRESH
HELP

DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT

ABOUT

DISPLAY THE PNMT VERSION NUMBER


THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY
AND TO UPDATE EQUIPMENT INFORMATION
THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE
USER NAME AND PASSWORD.

--ir=
r

THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW

LOGIN / LOGOUT
CHANGE PASSWORD
ALARM BUZZER

THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND


DEFINE THE BUZZER SOUND

THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN
THE NETWORK

CONNECT
EXIT

THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM

PNMT

NEC

NE SPECIFIC MENU ITEMS


I

CONFIGURATION

EVENT LOG
I

LINK PERFORMANCE MONITOR

LTHIS

NECITR-YTC
ART-MAR/04 V02

FUNCTION DOWN LOAD THE PERFORMANCE DATA FROM THE SELECTED NE AND
OPEN THE G826 LINK P~RFORMANCE INFORMATION WINDOW.

THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND
DISPLAY THE INFORMATION IN EVENT LOG WINDOW

"

FREQUENCY

SETTING

EQUIPMENT SETUP
MTPC / A TPC MODE

PROVISIONING

FRAME 10

MAINTENANCE
MAIN INTFC ELCT/OPT
REDUNDANCY SELEC
ALS DELAY TIME
MAINT MODE ON/OFF

OH ASSIGNMENT

NEAR END LOOPBACK

MTPC STATUS

FAR END LOOPBACK

ATPC STATUS

IF LOOP3ACK

SUB BB INTERFACE

SWITCHOVER (1+1)

BER THRESHOLD

TX MUTE ON/OFF
CW ON/OFF
ALS RESTART
ATPC MANUAL

PNMT

10

NEC

PNMT LOGIN I LOGOUT & EXIT

NECITR-YTC
ART-MAR/04 V02

"

rj:'~!PN NT' "

:}b}1..f.:

CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN
THE LOGIN/LOGOUT WINDOW

TO LOGIN SELECT LOGIN IN THE


LOGIN/LOGOUT WINDOW.
ENTER THE USER NAME ACCORDING TO THE
PRIVILEGES AND THE PASSWORD.
CLICK OK TO LOGIN

Username:
Password: .

Fj

~;.

EJ

login I logout
,

r.

TO PROTECT THE NETWORK AND NETWORK


MANAGEMENT SYSTEM FROM UNAUTHORIZED
ACCESS OR MODIFICATIONS, FIVE LEVELS OF
USERS ARE DEFINED WITH DIFFERENT
PRIVILEGES. THE FUNCTIONS AVAILABLE
DEPENDS ON THE USER ACCESS LEVEL, (SEE
THE TABLE NEXT PAGE)

.~

TO LOGOUT SELECT LOGOUT IN THE


LOGIN/LOGOUT WINDOW AND CLI,CKOK.

!~,~.~.~.ij

Password:

PNMT

11

NEC
NECITR-YTC
ART-MAR/04 V02

USER NAMES & PRIVILEGES


-

Category
SYSTEM

PROVISIONING

MTI'C

ONNECT (REMOTE
MTPC TX POWER
i\\.DDITIONAL

THRESHOLD

SUB INTERFACE
OIl ASSIGNMENT

SKITI'

PEHFORM;\NCE

MONlTOR
EVENT U)(;
AUX I/O

('THI,

CONTIOI,
D()WNI,OAD
UI'LOAD
CPt' RESET

l1li

/ MINIMUM
LEVEL

III
l1li

II

III
l1li

III

III

III

III

II

III

III

III

III

III

III

l1li

III

III

III

III

III

III

III

SD ( MUX / DMR)
MAIN OUTI'UT CONTROL

..

II

III

II

III

ALS ENABLE/DISABLE

l1li

i!I!

l1li

(RADIO)

AND ALS DELAY

SUB INTERFACE

!II

III

II

WS INTFC AND WS LINE LENGTH

!II

II

l1li

ASSIGNMENT

!II

!II

III

CHANNEL

II

III

III

III

III

III

III

l1li

!III

III

!III

III

USAGE

DIRECTION

EQUIPMENT
NE NAME

MAINTENAN('E

l1li

II

V-ll-?
EQUIPMENT

l1li

II
l1li

E-BER (MUX / DMR)

RX SWITCH

MAIN INn:JUACE

Admin

II

III

HIGH BER(RADIO)

Remote

l1li

LEVEL

ADDITIONAL AIT
ODU CPU ALM MODE

BEHTHRESIIOLD

Local

LOGIN)

AIT

ATPC MAXIMUM

. RX

User
II

BUZZER

RX THRESHOLD
All'C

Monitor

Item
ALARM

SETTING

SETUP

NOTE

III

III

II

III

MAINT MODE ON/OFF

II

III

II

l1li

TXIRX FREQUENCY
TX / RX SWITCH

II

III

III

III

III

TX MUTE
LOOPBACKI
LOOP BACK2 AND IF LOOPBACK
CW
ALS RESTART
A TPC MANUAL
PMON THRESHOLD
SAVE TO DISK
SA VE TO DISK
INPUT AND OUTPUT
RELA Y CONFIGURATION
DATE / TIME
CONFIGURATION
FILE
PROGRAM FILE
CONFIGURATION
FILE
RESET

II
II

II
II
II

PNMT

..
..
..
II

..
..
II

..

IIJ
II
II
III
II

l1li
l1li
l1li
II
II
II
III

III
III
II
III
II
III
II
II
!II
l1li

III

l1li
III
III
III

..

..

III

12

NEC

OVERALL WINDOW

NECITR- YTC
ART-MAR/04 V02

OVERALL WINDOW FOR (1+1) CONFIGURATION

e~G

~:
- -'W'

!": ConflQuratlon

.i

Selet:ted
tletwork
.~_.. '0'_"0'
...
"""""""'''

rgJEventLoQ

Element

MTPCTXPower
#TXFrequericy
RXFrequency
Frame10

.0'"
0

! (?J LlnkPerformanceMonltor

-17 dB
7282.000 MHz
7443.000MHz
1

MTPCTX Power
TX Frequency
RXFrequency
Frame10

I:~riAOxYiil
I". CTRti?kl

OFF
NO.1
NO.1

OFF
NO.1
NO.2
~

MTPC MODE

OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION:

.'

ATPC MODE

WHEN MTPC MODE IS SELECTED, MTPC POWER LEVEL

TX AND RX FREQUENCIES USED

FRAME 10 USED

TX POWER CONTROL MODE SELECTED (ATPC OR MTPC)

MAIN INTERFACE USED (ELECTRICAL OR OPTICAL)

ALS FUNCTION ENABLE / DISABLE STATUS

MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR


CHANGE TO YELLOW.

SELECTED TX AND RX CHANNEL IN (1+1) CONFIGURATION

OVeran

Really

CLICK THE OVERALL TAB TO DISPLAY THE OVERALL


, WINDOW

PNMT

13

NEC

ODU WINDOW

NECITR- YTC
ART-MAR/04 V02

CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU
WINDOW TO VIEW THE ODU DETAILS
ODU WINDOW FOR (1+1) CONFIGURATION

r~

Alarm

11Selected 'I

i Metering

i I
I.

RX Level

la m

I. <,.... .

I httf/RXl.:EYEL4iMih,1
I

:J

-61 dam

'RXLEVEL

Metering
I
RXLevel

I~

I
I -60dBm I

I Not
""",, II

..COMMON

Alarm

Alarm

,_J~
~

11-

CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS

PNMT

14

NEC

ODU DETAIL
TX

I "Selected

Alarm

'I

Metering

1"Dtpower
MTPC Status
MJRcTXPower
"

+8 dBm

NECITR-YTC
ART-MAR/04 V02

IN (1+1) CONFIGURATION, ONLINE SELECTED/NOT SELECTED STATUS


GREEN
SELECTED
WHITE
NOT SELECTED
TX INPUT ALM-

LOSS OF TX IF INPUT LEVEL IN THE ODU

TX POWER ALM-

TX RF POWER DECREASES 3 TO 6 dB FROM NOMINAL

-17 dB
VlRX1U:'ireshbldLevel, -55 dBm
Additioha I'Attenuation
0 dB

STATUS AND MONITORING

0 dB
-10 dB
-55 dBm
0 dB
HOLD

"

TX POWER METERING -

TRANSMITTED POWER OF THE ODU IN dBm

MTPC TX POWER -

INDICATES THE ATTENUATION VALUE USED IN MTPC MODE

RXTHRESHOLDLEVEL-

INDICATES THE RX LEVEL AT WHICH ATPC IS ACTIVATED

ADDITIONAL ATTENUATION - INDICATES THE AMOUNT OF ADDITIONAL ATTENUATION USED


ATPC CONTROL RANGE ODU ALARM MODE

MAX AND MIN POWER LEVELS FOR ATPC MODE


WHEN CONTROL BETWEEN IOU AND ODU FAIL THE ODU OUTPUT POWER

SETTING
RX
Alarm

~
,

0
"

'

,,,,,,
""

, "".,.
"""""j

Metering
I

"

RX LEVEL ALM

'

fi ~ l!iTE'WELr
",
'.,J''':".J',',

W.',;cWM,.
'~4,""_"
'" w.

4,RXLevel

Metering
I~st; J~;QWe~i!$upply

ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL

RX LEVELMONITOR-

-52 dBm

-44 V

ODU RF RX LEVEL IN dBM

APC ALM -

INDICATES THE ODU LOCAL OSCILLATOR UNLOCK CONDITION

CABLE ALM -

INDICATES THAT COMMUNICATION BETWEEN ODU AND IOU FAILS

POWER SUPPLY METERING - DISPLAY THE VALUE OF ODU POWER SUPPLY LEVEL IN VOLTS

STATUS COLORS
GREEN
NORMAL
RED
ALARM

PNMT

15

NEC
NECITR-YTC
ART-MAR/04 V02

IDU WINDOW
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
IDU WINDOW FOR (1+1) CONFIGURATION

! MODULE
i Alarm
i ~SWUNIT

i!
I

I
I
!

! ,MDUNIT

""'.""

"-'---'-'------

! No.2 MD UNIT ----......----! rTX

I Not Selected I

II

, ! rRX

i !! Alarm

! COMMON
I Alarm
i 18IG,MDCpu_1
!

CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO

PNMT

THE IDU DETAILS

16

NEC
NECITR-YTC
ART-MAR/04 V02

IDU DETAIL
MAIN INTFC ALM -150MB INTFC / OPT INTFC FAILURE
SUB INTFC ALM - WS INTFC / LAN CARD FAILURE ( OPTION)
MODEM ALM 1"2 - MODEM 1 OR MODEM 2 FAILURE
PS ALM 1-2 -IDU1 OR IOU 2 POWER SUPPLY FAILURE

"
- No.1

MD UNIT

TXAlarm

~
~

IN (1+1) CONFIGURATION, ON LINE SELECTED/NOT SELECTED STATUS


GREEN
SELECTED
WHITE
NOT SELECTED
MOD ALM

- MODULATORFAILURE

DUE TO TX SID~ LSI FAILURE

DEM ALM - DEMODULATOR FAILURE DUE TO RX SIDE LSI FAILURE


HIGH BER ALM -IN THE 1+1 CONFIGURATION HIGH BER ALM ON THE RADIO SECTION

IDU COMMON ALARMS


MAIN INTFC LOS - LOSS OF STM-1 INPUT SIGNAL
SUB INTFC LOS - WS INTFC OR LAN CARD INPUT SIGNAL FAILURE
MDCPU -INDICATES COMMUNICATION FAILURE BETWEEN CPU AND OTHER MODULES
FAILUREFROMTHE MUXSIDE
egrapelMIJJX] LOF MUX - STM-1SIGNALSYNCHRONIZATION
egrade[DMR] LOF DMR - STM-1SIGNALSYNCHRONIZATION
FAILUREFROMTHE RADIOSIDE
E-BER MUX - EXCESSIVE BER ALARM FROM THE MUX SIDE
E-BER DMR - EXCE$SIVE BER ALARM FROM THE RADIO SIDE
SIGNAL DEGRADE MUX - SO ALARM OF THE ATM-1 SIGNAL FROM MUX SIDE
STATUS COLORS
GREEN
NORMAL
RED
ALARM

SIGNAL DEGRADE DMR - SO ALARM OF THE STM-1 SIGNAL FROM RADIO SIDE

PNMT

17

NEC

IDU DETAIL

NECITR-YTC
ART-MAR/04

V02

MAIN INTERFACE STM-1


ALS ALS DELAY TIME -

WHEN OPTICAL INTERFACE IS USED, ALS FUNCTION ENABLE IDISABLE STATUS


WHEN ALS IS OPERATING DELAY TIME BETWEEN 2SEC LASER TRANSMISSIONS

STM-1 OUTPUT CONTROL - STM-1 O/P MS AIS IS INSERTED INDICATE "NORMAL"


"UNDER EXECUTION" WHEN UNFRAMED ALL"1" ARE INSERTED
MAlmNTE~FACE 10/100 BA~E-T
LINK WHEN LAN PORT CONNECTION TO EXTERNAL EQUIPMENT IS DISCONNECTED
COLLISION MODE

INDICATE "ALARM" OTHERWISE "NORMAL"


WHEN LAN PORT COLLISION STATUS "NORMAL" OR "COLLISION"
LAN PORT MODE IS 10BASE-T OR 100 BASE-T

DUPLEX LAN PORT DUPLEX MODE USED IS "FULL DUPLEX" OR "HALF DUPLEX"
LINK DOWN CONTROL - FAR END LINK DOWN CONTROL STATUS "NORMAL" I "UNDER EXECUTION"

~SUB INTFC

$UI?~JNTERFAGI;
SUB INTERFACE - TYPE OF SUBINTFC USED (WS/LAN) OR NOT USED STATUS
WS INTFC TYPE OF WS CARD USED, 2MB OR 1.5 MB -INVALID WHEN WS INTFC IS NOT USED
WS LINE LENGTH - WHEN THE WS INTFC CARD USED IS 1.5MB TYPE, LINE LENGTH SETTING
AIS RCVD -

IN THE WS INTFC CARD AIS SIGNAL IS RECEIVED OR NOT STATUS

AIS SEND -

IN THE WS INTFC CARD AIS IS SENT OR NOT STATUS

'"

0" Assignment

.'

I Assignmenti1?1
Customize I

<>

QHA$$IGNMENI
ASSIGNMENT-

DSC2
58CT
NotUsed
DSC4

OH ASSIGNMENT SELECTED; CUSTOMIZE


OR EASY
.
ASSIGNMENTS FOR EACH OH CHANNEL
~"""'--"""''''''

BER METERING -

CURRENT VALUE OF THE DETECTED BER

SIGNAL DEGRADE (MUX) E-BER (MUX) -

THRESHOLD SETTING FOR SIGNAL DEGRADE BER FOR MUX SIDE


EXCESSIVE BER THRESHOLD SETTING FOR MUX SIDE

SIGNAL DEGRADE (DMR) E-BER (DMR) -

THRESHOLD SETTING FOR SIGNAL DEGRADE BER FOR RADIO SIDE


EXCESSIVE BER THRESHOLD SETTING FOR RADIO SIDE

HIGH BER RX SWITCH -

THRESHOLD SETTING FOR HIGH BER ALARM (FOR 1+1 SYSTEMS)


BER THRESHOLD SETTING FOR REDUNDANCY SWITCHING (FOR 1+1 SYSTEMS)

PNMT

18

NEC
NECITR- YTC
ART -MAR/04 V02

CHANGE PASSWORD

CLICK ON CHANGE PASSWORD IN THE SYSTEM


DROPDOWN MENU TO OPEN THE CHANGE PASS WORD
WINDOW.
<>

ENTER THE OLD PASSWORD

ENTER THE NEW PASSWORD

RE-ENTER THE NEW PASSWORD TO CONFIRM

CLICK OK TO CHANGE THE


PASSWORD.
CLICK CANCEL TO EXIT WITHOUT
CHANGING PASSWORD

PNMT

19

NEC

ALARM BUZZER

NECITR-YTC
ART-MAR/04 V02

CLICK ON ALARM BUZZER ON


THE SYSTEM DROP DOWN
MENU TO OPEN THE ALARM
BUZZER SETTING WINDOW.

SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER


SOUND CAN BE CHANGED BY SELECTING A DIFFERENT
WAV FILE. USE BROWSE ~TO

THE WAV FILE.

~..

LOCATE THE PATH TO

LICK HERE TO TEST THE BUZZER SOUND

CLICK OK TO IMPLEMENT THE


OPTION SELECTED OR CLICK
CANCEL TO EXIT WITHOUT
CHANGING THE SETTINGS.

SELECT BEEP TO ENABLE THE


BUZZER WITH BEEP FREQUENCIES
INSTEAD OF WAVE FILE SOUND
BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES
AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL
FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED
BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.

PNMT

20

NEC

SEARCH I CONNECT TO NETWORK ELEMENT

NECITR- YTC
ART-MAR/04 V02

CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.

AlarmBuzzer..
Connect.. .
Exit

TOOL BAR ITEMS

'~;..!No:OO1

,
_J

~- Pasolink
V31+0
P asolink V3 1 +0

No.002

Alarm'

Normal

Normal

No.OO1

Normal

Alarm

Normal

CLICK THE SEARCH FOR NETWORK ELEMENT TO


SEARCH AND LIST THE OTHER NEs IN THE
NETWORK

172.018.000.001

<t

TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND


HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK
ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE
DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE

r'I*PNMT
~$tem

",

.<.,

. ,', ,.'

tI elp

DISPLAYED IN THE LINK SUMMARY WINDOW. 1

l.i~r\.'!'",

Ff

tONNECT
TO NETWORKELEMENT
SEARCHFORNETWORKELEMENT

PNMT

CV

'

Do you

w~:to

. . ;"".,I

.,

~~nnect10

the selected

Netw~k
f

~~.
PNMT

Iement ?

MTPC 1X Power
1X Frequency
RX Frequency
Frame ID

'23<8
23010.750 MHz
22002.750 MHz
1

21

NEC

HELP FUNCTION

NECITR- YTC
ART-MAR/04 V02

PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN


PDF FILE FORMAT. IF THE ACROBAT READER' IS
INSTALLED IN THE PNMT PC, CLICKING HELP AND
SELECTING THE RELEVANT PNMT FILE WILL OPEN THE
PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.

PNMT(PASOLINKMIU).pdf
PNMT(PASOLINKV4).pdf
PNMT(PASOLINK).pdf
PNMT(PASOLINK+PDH).pdf
"

System Refresh Help

,,

~~--

I EB ~ {;-

BUZZER STOP - ICON IS ACTIVE ONLY WHEN


THE
ALARMED
EQUIPMENT
DISPLAY
WINDOW IS SELECTED FROM THE TABs OR
FROM THE BLOCK DIAGRAM SYMBOLS.

PNMTRev4.20.001

REFRESH - OPEN THE NE LIST WINDOW


CONNECT

- OPEN

f3

About PNhH

light (C) 2001 N

THE NE LIST WINDOW

OPEN THE LOGIN/LOGOUT WINDOW


DISPLAY THE PNMT SOFTWARE VERSION INFORMATION

PNMT

22

NEC

EQUIPMENT CONFIGURATION WINDOW

NECITR-YTC
ART-MAR/04 V02

NE SPECIFIC MENU-BAR-

~LinkPerformanceM
onitor

1kx'

'.'~W'",

h;;

"';';

CLICK CONFIGURATION FROM THE NE SPECIFIC MENU BAR AND FROM THE
DROP DOWN MENU SELECT EQUIPMENT SETUP.

INDICATES THE ODU FREQUENCYBAND INFORMATION AND TX/RX


FREQUENCIES

7414.000

MHz

7483.750
161.000

MHz
MHz

IN 1+1 HOT STBY, ODU1 IS


ONLY SHOWN AS ODU2 HAS
_THE
SAME SETTING
IN 1+1 TWIN_PATHBOTH
ODU1 AND ODU2 ARE
SHOWN, AS THE SETTINGS
ARE INDEPENDENT

Upper
7443.000

MHz

7282.000 MHz
--..-.-..--...........--..-..-.-....-................-..-..............

PiT><P6We(Cbntf6r

MTPC

lDU

SHOW THE IDU CONFIGURATION

1+1(HS)
STM-1
RST

i
i

- ~~
I
I

SHOW THE FRAME ID SETTING

STM-1(Electrical)
128QAM

IN 1+1 HOT STBY, FRAME ID


FOR NO.1 AND NO.2 ARE THE
SAME
IN 1+1 TWIN PATH FRAME ID
CAN BE SET THE SAME OR
DIFFERENT

SETUP BUTTON OPEN THE SETUP


CONTROL WINDOW

CTRl

NE NAME IS DISPLAYED. CAN BE


CHANGED FROM HERE

NOTE ENTERED FOR THE


SELECTED NE IS DISPLAYED. CAN
BE CHANGED FROM HERE

','JPAddre$$
MGNENahisi

"om.

172.18.0.1
NO.001

INDICATE THE IP
ADDRESS USED BY THE
NE

IN THE CASE OF 1+0 ONLY ONE ODU AND IDU SETTINGS ARE
DISPLAYED

PNMT

23

NEC

CONTROL SETTING

THE NAME ENTERED TO IDENTIFY THE NETWORK


ELEMENT CAN BE CHANGED FORM THIS WINDOW. A
MAXIMUM OF 32 CHARACTERS CAN BE USED.

FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE


NAME BundN TO OPEN THE NE NAME SETTING
WINDOW.

NECITR-YTC
ART-MAR/04 V02

.
NO.001
172.18.0.1

ENTER THE NAME AND CLICK EXECUTE TO SHOW THE


NAME IN THE EQUIPMENT SETUP WINDOW.
CLICK THE NOTE BUTTON TO OPEN THE
NOTE WINDOW.

A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE


ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS
CAN BE USED IN THIS FIELD'
ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE
NOTE IN THE EQUIPMENT SETUP WINDOW.

PNMT

24

NEC
NECITR- YTC
ART-MAR/04 V02

SETUP CONTROL WINDOW


FROM THE EQUIPMENT SETUP WINDOW
CLICK ON THE SETUP BUTTON

I...

Setup

FREQUENCY BAND RELATED INFORMATION OF THE


ODU IS DISPLAYED AUTOMATICALLY

ACTIVE WHEN THE REDUNDANCY CONFIGURATION


IS 1+1 TWIN PATH.

..71

07483.750 MHz
ShifCFrequency

ENTER OR SELECT THE TX FREQUENCY ACCORDING


TO THE FREQUENCY TABLES. CORRESPONDING RX
FREQUENCY IS AUTOMATICALLY DISPLAYED

Upper/LOW"3f

01f;i 000MHz
UpP'"'f

SELECT THE TX POWER CONTROL MODE ATPC


OR MTPC
REDUNDANCY CONFIGURATION SELECTION
AUTOMATICALLY INDICATES THE SOH SIGNAL TYPE
MAIN INTFC SELECTION
AUTOMATICALLY INDICATE THE MODULATION TYPE
FRAME 10 SETTING (0-7). IN THE CASE OF HOT
STANDBY BOTH NO.1AND NO.2 CHANNEL HAVE THE
SAME SETTING.

'

IN THE CASE OF TWIN PATH FRAME 10 FOR NO.1 AND


N02 CHANNELS CAN BE SET SEPARATELY..
CLICK THE EXECUTE BUTTON TO CARRY
OUT THE EQUIPMENT SETUP SETTINGS.

PNMT

CLICK THE CLOSE BUTTON TO EXIT THE


SETUP CONTROL WINDOW

25

NEC

FREQUENCY CONTROL

NECITR-YTC
ART-MAR/04 V02

07414.000MHz

ODU FREQUENCY BAND INFORMATION ARE DISPLAYED


HERE.

07483.750MHz
0161.000MHz

.'

CHANGE THE TX FREQUENCY AND THE

:-I M.Hz CORRESPONDING RX FREQUENCY IS DISPLAYED

WHEN SETTING THE FREQUENCY FOLLOWING SHOULD BE CONSIDERED


fj FOR THE 6/7/8 GHZ BAND ODUs THE TRANSMIT FREQUENCY MUST BE THE SAME AS
THAT INDICATED ON THE LABEL ATTACHED ON THE SIDE OF THE ODU. IF ANOTHER
FREQUENCY IS SET, NORMAL TRANSMISSION AND RECEPTION OF THE RF SIGNAL IS
NOT POSSIBLE.
fj FOR THE 11-38 GHZ BAND ODUs, THE FREQUENCY SET SHOULD BE WITHIN THE
TRANSMIT FREQUENCY BAND OF THE ODU. (REFER TO THE DOCUMENT RADIO

FREQUENCYPLANFORTHEPASOLlNK+).
fj

FORTHE 11-38GHZBANDODUsUSEDIN 32 QAMSYSTEMS,THE FREQUENCYSETTING


SHOULD BE AT LEAST +21 MHZ AWAY FROM THE BAND'S "START" FREQUENCY AND
AT LEAST -21 MHZ AWAY FROM THE BAND'S "STOP" FREQUENCY.

II FOR THE 11-38GHZ BAND ODUs USED IN 128 QAM SYSTEMS, THE FREQUENCY
SETTING SHOULD BE AT LEAST +12 MHZ AWAY FROM THE BAND'S "START"
FREQUENCY AND AT LEAST -12 MHZ AWAY FROM THE BAND'S "STOP" FREQUENCY.
II IN (1+1) HOT-STANDBY SYSTEMS, THE FREQUENCY ENTERED IS AUTOMATICALLY SET
FOR BOTH NO.1 AND NO.2 ODUs
II IN (1+1) TWIN PATH SYSTEMS, THE FREQUENCY SETTING OF THE NO.1 AND NO.2
ODUs ARE NOT IDENTICAL AND ARE ENTERED SEPARATELY.

PNMT

26

NEC

PROVISIONING

NECITR-YTC

ART-MAR/04V02

00~E~tLBI~rpfT5 Q~kPei'f6rmanceMonitor
;~;"7Wf.7NfTI";'1M-';JJj::,
.
1'\~:9pip~ent~:~Ju~I;::}\

:~Maintenance

CLICK CONFIGURATION ON THE NE SPECIFIC MENU AND SELECT

1 PROVISIONING TO
-....--.-...--..--.--.-.....................

OPEN THE PROVISIONING WINDOW.

, MAININTFC

:STM-1Optical
.

ALS ENABLE AND ALS DELAY SETTING

Not Used

ALSDelayTlme
',ALS
..

60sec
Enable

10J100BASE-T
PORT Usaoe
PORT 1
PORT 2
Far End Link Down
Clock Source

INDICATE THE LAN PORT SETTINGS

OH ASSIGNMENT SELECTION
-:;r

-~
Q
INDICATE OH CHANNEL ASSIGNMENTS

Assignmenl I

P1 :75MbpsIP2:75Mbps
Auto Nealotiation
Auto NeaioUation
Disable
Internal Clock

Customize I

Channel Usage
DSC2
""""58"C1
NotUsed
DSC4

~
..:?

0E-0

1E-6
1E-3

SUB INTERFACE SETTING

BER THRESHOLD SETTING

MS-AIS GENERATION SETTING

Direction
CO-5ifiiCtiOn
Co-Direction

f
INDICATE THE TX POWER CONTROL
MODE
WHEN MTPC MODE IS SELECTED MTPC
POWER SETTING
WHEN ATPC MODE IS SELECTED ATPC
POWER SETTING

EITHER MTPC SETTING OR ATPC SETTING


WINDOWS WILL BE DISPLAYED AT A TIME,
DEPENDING ON THE TX POWER CONTROL
MODE SELECTED.

"','MTPC 1)( Power4tw:


,. RXThreshold Level,
Additional Attenuation

.17 d8
-55 d8m

1)( MAX Power


1)( MIN Power
RX Threshold Level
Additional Attenuation

a d8
-10 d8
.55 d8m
a d8

ODUALMM!J.CtL..J

OdS

HOLD

PNMT

27

NEC

ALS SETTING

NECITR-YTC
ART-MAR/04 V02

ALS
CLICK ALS BUTTON IN THE PROVISIONING WINDOW TO
OPEN ALS SETTING WINDOW.. THIS FUNCTION IS
AVAILABLE
.
. FOR OPTICAL
............. INTERFACE ONLY.

r MAIN INTFC--.--Enable

60sec

TO ENABLE ALS FUNCTION SELECT ENABLE OR SELECT


DISABLE TO DISABLE IT, CLICK EXECUTE TO CARRY OUT
THE SELECTION. CLICK CLOSE TO EXIT ALS SETTING
WINDOW.

"
ALS DRAY TIME
AUTOMATIC LASER SHUT DOWN FUNCTION

CLICK ALS DELAY TIME BUTTON IN THE


PROVISIONING WINDOW TO OPEN ALS
DELAY TIME SETTING WINDOW.. THIS
FUNCTION IS AVAILABLE FOR OPTICAL
INTERFACE ONLY.

WHEN THE OPTICAL SIGNAL INPUT TO THE


MAIN INTFC IS LOST, THE ALS FUNCTION
AUTOMATICALLY SHUTS THE MAIN INTFC
OUTPUT LASER. MAIN INTFC WILL THEN
PERIODICALLY TRANSMIT A 2MSEC BURST OF
LAS:=R.

SELECT THE DELAY TIME FOR ALS


OPERATION AND CLICK EXECUTE.

THE ALS DELAY TIME DEFINES THE DURATION


BETWEEN 2SEC BURSTS OF LASER EMISSION.
THE DELAY TIME CAN BE SET TO 60, 180 OR 300
SECONDS.

CLICK CLOSE TO EXIT THE ALS DELAY


TIME SETTING WINDOW.

PNMT

28

NEC

OH ASSIGNMENT

NECITR- YTC
ART-MAR/04 V02

THERE ARE TWO VOICE CHANNELS, TWO V11 CHANNrLS AND OPTIONAL LAN PORT AVAILABLE IN PASOLINK PLUS EQUIPMENT. IT IS POSSIBLE TO
ASSIGN THESE CHANNELS TO ANY OF THE EIGHT SDH OH AND RADIO OH CHANNELS AS SHOWN IN THE DIAGRAM. THE ASSIGNMENT OF THESE
CHANNELS CAN BE CUSTOMIZE BY THE USER OR USE THE FACTORY DEFAULT....
CLICK ASSIGNMENT BUTTON TO OPEN THE
.
PROVISIONING WINDOW
OH ASSIGNMENT SETTING WINDOW.
rOH Assignment
I

.j. E1 (MUX)
F1 (MUX)

.j..j. --

E1 (DMR)
F1 (DMR)
DSC1 TO 4

.j.~(MUX)
.j.
f'1 (MUX)

EASY
WHEN "EASY" IS SELECTED THE SAME
SETTING AS THE FACTORY SETTING IS
USED. WITH THIS SELECTION, LAN CARD
ASSIGNMENT
IS NOT POSSIBLE. V11
DIRECTION SETTING CAN BE CHANGED IF
REQUIRED.
CUSTOMIZE
WHEN CUSTOMIZE IS SELECTED IT ALLOWS
THE
ASSIGNMENT
OF
TWO
VOICE
FREQUENCY CHANNELS (VF1 AND VF2),
TWO DATA CHANNELS (V11-1 AND V11-2)
AND OPTIONAL LAN CARD INTERFACE.

"

TO USE CUSTOMIZE SETTING CLICK CHANNEL USAGE


BUTTON TO OPEN THE CHANNEL USAGE SETTING WINDOW.
TO CHANGE THE
DIRECTION OF V11
CHANNELS CLICK
DIRECTION BUTTON AND
SELECT CO-DIRECTION
OR CONTRA-DIRECTION.
THIS SETTING IS
AVAILABLE FOR BOTH
EASY AND CUSTOMIZE.

V11.2
VF.1
VF-2

CLICK EXECUTE TO CARRY OUT THE


SETTING AND CLICK CLOSE TO EXIT THE
SETTING WINDOW.

IF ANY OF THE VOICE, DATA AND LAN


CHANNELS ARE NOT USED DESELECT
THE USED SETTING

TO ASSIGN ANY OH CHANNEL TO VOICE,


DATA OR LAN CHANNEL, CLICK THE
BUTTON INTERSECTING THE COLUMN
AND ROW. SELECTED SETTING IS
SHOWN IN GREEN,

CLICK EXECUTE BUTTON TO ASSIGN


THE CUSTOMIZE SETTING. CLICK CLOSE
TO EXIT

PNMT

29

NEC

SUB INTERFACE SETTING

NECITR- YTC
ART -MAR/04 V02

THEREARE SEVERALTYPESOFOPTIONALSUB INTERFACECARDSAVAILABLEFORPASOLINKPLUSEQUIPMENT.SUB INTERFACESETTINGIS


AVAILABLEFROMTHE PROVISIONING
WINDOW.

. 2.048 MBPS UNBALANCED WS INTFC [G7905A]

.
.
.
.

SELECT NOT USED WHEN SUB INTFC


CARD IS MOUNTED BUT NOT USED.:

2.048 MBPS BALANCED WS INTFC [G7905B]

SELECT WS INTFC WHEN THE WS INTFC


CARD IS MOUNTED AND USED..

1.544 MBPS (AMI OR B8Z3) WS INTFC [G7905C]


CLUSTER ALARM CARD

SELECT WS/CLUSTER ALARM WHEN


THAT OPTION CARD IS MOUNTED AND
USED..

LAN CARD [G7906A]


r. Waysidel

Cluster Alarm

r Cluster
Alarm (~1 DBASE.
T

EKecute

LANmCA.RQ
WS INTFC
1.5M8(AMI)
0-40.5M

<

. il8MLt.1

SELECT CLUSTER ALARM WHEN THE


CLUSTER ALARM CARD IS MOUNTED
AND USED..
SELECT 10BASE-T WHEN THE LAN CARD
IS MOUNTED AND USED..
CLICK EXECUTE TO IMPLEMENT THE
SUB INTFC CARD SELECTiON

THISOPTIONISAVAILABLEWITHBOTH32 QAMAND 128QAMSYSTEMS.

. 32 QAM SYSTEMS USE THE RFCOH AT A RATE OF 2.048 MBPS


. 128QAM SYSTEMS USE THE OH ASSIGNMENT TO SELECT DSC

OR

RSOH (E1/F1) AT A RATE OF 64 KBPS.


THE SWITCH ON THE LAN CARD SHOULD BE SET TO CROSS OR STRAIGHT
ACCORDING TO THE TYPE OF LAN CABLE USED.

THIS OPTION IS AVAILABLE WITH


32 QAM SYSTEMS ONLY..

Co:n:5f;fBI

Not used

Close

TO USE THE SUB INTFC OPTION


CLICK THE SUB INTFC BUTTON..
TO SELECT THE TYPE OF
WS INTFC USED, CLICK THE
WS INTFC BUTTON AND
FROM THE WS INTFC
SETTING WINDOW SELECT
THE WS INTFC TYPE
,

1.5MB
fBSZSI

(Me

CLICK EXECUTE TO IMPLEMENT THE SELECTED


WS INTFC OPTION

WHEN 1.5 MB IS SELECTED


THE LINE LENGTH OF THE
WS INPUT SIGNAL SHOULD
BE SELECTED.
CLICK THE WS LINE LENGTH
BUTTON TO OPEN THE
SETTING WINDOW.

CLICK EXECUTE TO IMPLEMENT THE SELECTED WS


LINE LENGTH SETTING

IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW

PNMT

30

NEC
NECITR-YTC
ART-MAR/04 V02

A TPC SETTING
AUTOMATIC TX POWER CONTROL
ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION
POWER DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM
DOES NOT APPEAR.

ATPC TX MAX Power(No.1)

ATPCTXMINPower(No.1)- No.OO1

- No.OO1

!,

VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER.


IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN
FOR AN ATPC MAX PWR SETTING OF ODB AND ATPC MIN PWR
SETTING OF -10DB, THE ODU OUTPUT POWER DURING ATPC
OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM

PROVISIONING WINDOW
ATPCStatus-

R)(,Yhreshold Level(No.1) - No.OO1"'.i;~;:

-1

RXTHRE$HQI"PJ"EYE;I"
WHEN THE MONITORED RX SIGNAL LEVEL
FALLS BELOW THIS LEVEL, CONTROL SIGNAL
SENT TO THE OPPOSITE STATION INITIATE THE
ATPC FUNCTION.
THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE
STATION IS SET TO ATPC MODE

lXMAX;!?ower'
TXMINPower
RXThresholdLevel
AdditionalAttenuation

AQDITIONAL ATTJ;J\~YA nON


ADDITIONAL ATTENUATION IS A SPAN
ATTENUATOR USED TO REDUCE THE TX
POWER IN SITUATIONS LIKE SHORT HOP
LENGTH.

'I

HOLD

CLICK THE APPROPRIATE BUTTON TO


OPEN THE SELECTED SETTING WINDOW..
AFTER SELECTING OR SETTING THE
PARAMETER CLICK EXECUTE BUTTON TO
IMPLEMENT THE SETTING.

THE ATPC CONTROLLED OUTPUT POWER


OR MTPC SET OUTPUT POWER, WILL BE
REDUCED BY THE SET ATTENUATION
VALUE.
ODU ALARM MODE
THIS ITEM DEFINES THE ODU TRANSMIT
POWER LEVEL WHEN CONTROL
COMMUNICATION BETWEEN THE IOU AND THE
ODU FAILS. WHEN THE TX POWER CONTROL
MODE IS SET TO MTPC THIS ITEM IS NOT
DISPLAYED.

ODU)\LMMode

0 dB
-23 dB
-55 dBm
0 dB

IN ALL SETTING WINDOWS, CLICK CLOSE


TO EXIT THE WINDOW
MAX HOLD:
SET THE ODU OUTPUT TO THE ATPC
MAXIMUM POWER LEVEL
MINIMUM HOLD:
SET THE ODU OUTPUT TO THE ATPC
MINIMUM POWER LEVEL

HOLD:

SET THE ODU OUTPUT TO THE LEVEL AT THE


TIME
OF
IDU-ODU
CONTROL
COMMUNICATION FAILURE.

PNMT

E~ecule
I
31

NEC

MTPC SETTING

NECITR- YTC
ART-MAR/04 V02

MIPC TX PQWER
MTPC TX PWR DEFINES THE ODU OUT PUT
POWER IN MTPC MODE. THE VALUE
ENTERED IS THE ATTENUATION LEVEL IN
DB FROM THE MAXIMUM ODU OUTPUT
POWER. IN ATPC MODE THIS MENU ITEM
DOES NOT APPEAR.

.
.

32 QAM SYSTEM 0 TO 23 DB
128QAM SYSTEM 0 TO 20 DB
TO GET THE MAXIMUM OUTPUT POWER
SET THE ATTENUATION TO ODB.

IN THE PROVISIONING WINDOW THE MTPC


STATUS IS ACTIVE WHEN THE TX POWER
CONTROL MODE IS SET TO MTPC..

RX.THR!;$HQl.,[)!"EV!;!"
IN MTPC MODE THIS VALUE IS SET, IN CASE
THE OPPOSITE STATION IS SET TO ATPC MODE.
THEN, IF THE MONITORED RX SIGNAL LEVEL
FALLS BELOW THIS LEVEL, CONTROL SIGNAL
SENT TO THE OPPOSITE STATION INITIATE THE
ATPC FUNCTION.

~~.~.:.~
-55 dBm
0 dB

i-.I

CLICK THE APPROPRIATE BUTTON TO


OPEN THE SELECTED SETTING WINDOW..
AFTER SELECTING OR SETTING THE
PARAMETER CLICK EXECUTE BUTTON TO
IMPLEMENT THE SETTING.

AJ2.PJIlQJ'-1l~b__AII!;NUAIIQN
ADDITIONAL ATTENUATION IS A SPAN
ATTENUATOR USED TO REDUCE THE TX
POWER IN SITUATIONS LIKE SHORT HOP
LENGTH.

IN ALL SETTING WINDOWS, CLICK CLOSE


TO EXIT THE WINDOW

THE ATPC CONTROLLED OUTPUT POWER


OR MTPC SET OUTPUT POWER, WILL BE
REDUCED BY THE SET ATTENUATION
VALUE.
SETTING RANGE 1 TO 5 dB.

PNMT

32

NEC.
NECITR-YTC
ART-MAR/04 V02

10/100BASE-T SETTING
PQRIJlPQRTMQQ!;AN.PP!JP!..,E)(
$I;TTJNG
SETS THE MODE USED AND DUPLEX
SETTING. DEPENDS ON THE EXTERNAL
EQUIPMENT SETTING.

PoRT.U$AGI;.
SETS THE RATE USED BY PORT1 AND
PORT2

PORT

r P1: 75Mbps

r. P1: 1DDM
bpsr

P2: 75Mbps

P2: 5DMbps

Execute~

r Auto
Negot~tiO/1

r.

1DBASE-TI
HaUDuplex

1DBASE-TI
Full Duplex

10DBASE.TXI r
HaUDuplex

100BASE.TXI I

FullDuplex!
Execute

"'"

Far End Link

r Disable

r. Enable

Close

PORTUsage
P1:75Mbps/P2:75Mbps
PORT1
AutoNegiotiation
101100BASE,T
PORT2
AutoNegiotiation
FarEndLink Down
Disable
ClockSource
InternalClock

'4

CLICK THE APPROPRIATE BUTTON TO


OPEN THE SELECTED SETTING WINDOW..

AFTER SELECTING OR SETTING THE


PARAMETER CLICK EXECUTE BUTTON TO
IMPLEMENT THE SETTING.
IN ALL SETTING WINDOWS, CLICK CLOSE
TO EXIT THE WINDOW

ClockSource'-'InternalClock

Close

II~

II"

Execute

CLOQKSOURQ.!;
SELECTSTHE CLOCKUSEDBYTHE LANPORT

P1 : 1DDMbps
P2: NotUsed

IN THE PROVISIONING WINDOW THE


10/100BASE-T CONTROLS ARE ACTIVE
WHEN THE WHEN THE 10/100BASE-T MAIN
INTFC CARD IS MOUNTED

"._111"-

EAR!;N.P!"!NK.PQVVN
WHEN THE LINK IS DOWN SENDS THE
INFORMATION
TO
THE
FAR
END
TO
DISCONNECT THE FAR END LINK. THIS
FUNCTION CAN BE ENABLED OR DISABLED.

P1: BestEffort r
P2: BestEffort

r. DMRClock.)
Internal Clock

Close

Execute

PNMT

33

NEC
NECITR- YTC
ART-MAR/04 V02

BER THRESHOLD SETTING


BER THRESHOLD
THE BER IN THE PASOLlNK+
IN 3 SECTIONS

SYSTEM IS MONITORED

MUX SECTION
DMR SECTION
RADIO SECTION

PROVISIONING WINDOW

THE RADIO SECTION IS AVAILABLE IN (1+1) SYSTEMS ONLY


AND IS USED FOR SWITCHOVER FUNCTION
THE MUX AND DMR SECTION BER IS MEASURED IN TERMS
OF SIGNAL DEGRADE (SO) AND EXCESSIVE BER (E_BER).

'l

THE RADIO SECTION, ON THE OTHER HAND, MONITORS


THE BER FOR SWITCHOVER PURPOSES. WHEN THE BER
BECOMES WORSE THAN THE PRESET VALUE OF THE LOW
BEt{, THE RX SIDE SWITCHES TO THE OTHER CHANNEL IN
A 1+1 CONFIGURATION. THE PRESET VALUE MENTIONED
ABOVE IS CALLED THE BER THRESHOLD.

BER ALM THRESHOLD (RADIO) APPEARS


IN 1+1 REDUNDANT SYSTEMS ONLY

o4f--

SIX BER THRESHOLDS ARE AVAILABLE


HIGH BER: EXCESSIVE BER ALARM SETTING FOR THE RADIO
SECTION SET BEFORE ANY SWITCH OVER IN (1+1) REDUNDANCY
SWITCHING CONFIGURATION
LOW BER FOR RX SWITCH:
THE BER LEVEL FOR DEGRADED
SIGNAL IN THE RADIO SECTION. USED FOR RX SWITCH OVER IN (1+1)
SYSTEM.

C"')
0
I
W

0
uJ

uJ

to
0
uJ

to
uJ

ex)
0

'"
0

uJ

uJ

0
~

~
~

N
~

uJ

uJ

I
E-BER(DMR) EXCESSIVE BER LEVEL FOR RADIO SECTION. SET
WORSE THAN THE SWITCHOVER LEVEL.
SD(DMR)

L(')
0

High BER

I E-BER(OMR)I
I E-BER(MUX) I

SIGNAL DEGRADE BER LEVEL FOR RADIO SECTION.

Low BER for RXSW

SO(OMR)

SO (MUX)

E-BER(MUX) EXCESSIVE BER DETECT LEVEL FOR INPUT STM-1


SIGNAL FROM
THE MUX.
SD(MUX) SIGNAL DEGRADE ALARM LEVEL FOR INPUT STM-1 SIGNAL
FROM THE MUX
IN THE PROVISIONING WINDOW THE MTPC

~ . __n.-

-.. --...--

PNMT

34

NEC
NECITR- YTC
ART-MAR/04 V02

BER THRESHOLD SETTING

BER ALM Threshold(DMR)- No.OOl.

'.

..

.'..'

CLICK THE APPROPRIATE BUTTON IN THE


PROVISIONING WINDOW THRESHOLD SECTION TO
OPEN THE REQUIRED BER SETTING WINDOW..

AFTER SELECTING THE BER ALARM


THRESHOLD VALUE, CLICK EXECUTE
BUTTON TO IMPLEMENT THE SETTING.

IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW


...

,.......

BER ALM Threshold{Radio) .,.No.OOle-

r-~(

IN THE PROVISIONING WINDOW THE MTPC


~
~.~ .
_H --...--

PNMT

;../,",:./..c

r 3E.9

'

3E.10

35

NEC
NECITR- YTC
ART-MAR/04 V02

MAINTENANCE
CLICK MAINTENANCE, ON THE, CONFIGURATION
DROP DOWN MENU TO OPEN THE MAINTENANCE
WINDOW

TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO


MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE
WINDOW TO OPEN THE MAINTENANCE MODE SELECTION WINDOW. SELECT
MAlNT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE
SELECTION

THESE CONTROL ARE AVAilABLE FOR


(1+1) CONFIGURATION. PROVIDES
MANUAL SWITCH OVER OF PASOLINK
CHANNEL
FOR NORMAL OPERATION SELECT'
AUTO FOR AUTO REDUNDANCY
SWITCHING..

'-'-""-""---

AlS RESTART IS ACTIVE ONl Y WHEN


OPTICAL INTFC IS USED

MAINTENANCE WINDOW FOR (1+0)


CONFIGURA TlON (REMOTE NE)

~
Control
1*'. \:'ktMAlNTe':v;;.(~~q
ERROR'

E3

BEFORE TRYING TO CONTROL ANY


MAINTENANCE FUNCTION
SET THE
SELECTED EQUIPMENT TO MAINTENANCE
MODE. OTHERWISE AN ERROR MESSAGE.
WILL BE DISPLAYED

PNMT

OFF

OFF
OFF
OFF

OFF
OFF
22002.750 MHz
23010.750 MHz

36

NEC

LOOP BACK CONTROL


FROM THE MAINTENANCE WINDOW SET THE
SELECTED NE TO MAINTENANCE MODE

Control
L
MAlNT

ON

1-

NECITR- YTC
ART-MAR/04 V02

YELLOWBACKGROUND
INDICATE
MAINTENANCE
MODE

'rr-/)J

CLICK THE MA
OPEN THE FAR NO
WINDOW

CLICK THE
OPEN THE NEA'
WINDOW

Main Signal

LP BACK 2 BUTTON TO
BACK CONTROL

LP Back-2

- No.Om

------.---.---------

Execute
SELECT LOOPBACK ON OR OFF AND
CLICK ON EXECUTE TO ENABLE NEAR END
LOOPBACK ON THE SELECTED CHANNEL.
CLICK CLOSE TO EXIT THE LOOPBACK
CONTROL WINDOW..

CI&1e

SELECT LOOPBACK ON OR OFF AND


CLICK ON EXECUTE TO ENABLE FAR END
LOOPBACK ON THE SELECTED CHANNEL.
SELECT LOOPBACK ON OR OFF AND CLICK ON
EXECUTE TO ENABLE FAR END LOOPBACK ON THE
SELECTED CHANNEL.
CLICK CLOSE TO EXIT THE LOOPBACK CONTROL
WINDOW..
IF LOOP BACK IS NOT AVAILABLE FOR A REMOTE NE

PNMT

CLICK CLOSE TO EXIT THE LOOPBACK


CONTROL WINDOW..

37

NEC
NECITR-YTC
ART-MAR/04 V02

MAINTENANCE

THIS CONTROL SETS THE DURA nON THAT THE


LASER IS ON, WHEN ALS MANUAL RESTART
CONTROL IS PERFORMED.
CLICK THE ALS RESTART BUTTON ON THE
MAINTENANCE WINDOW TO OPEN THE ALS
RESTART CONTROL WINDOW. SELECT THE
DURATION OF THE LASER BURST AND CLICK
EXECUTE TO IMPLEMENT THE ALS MANUAL
RESTART CONTROL.

THIS CONTROL TRANSMIT AN UN- MODULA TED


CARRIER FOR MEASUREMENT PURPOSE. THIS
CONTROL MA Y INTERRUPT TRAFFIC.
CLICK THE CW (MOD CARRIER) BUTTON ON THE
MAINTENANCE WINDOW TO OPEN THE CW
CONTROL WINDOW. CLICK ON OR OFF AND
EXECUTE TO IMPLEMENT THE MAINTENANCE
CONTROL.

THIS CONTROL SWITCH OFF OR MUTE THE TX


OUTPUT POWER OF ODU110DU2 OF THE
SELECTED NE. THIS MAY INTERRUPT THE
TRAFFIC
CLICK THE TX MUTE BUTTON ON CH1 OR CH2
ON THE MAINTENANCE WINDOW TO OPEN THE
TX MUTE CONTROL WINDOW. CLICK ON/OFF AND
EXECUTE TO IMPLEMENT THE MAINTENANCE
CONTROL.

TO CLOSE ANY MAINTENANCE CONTROL


WINDOW CLICK CLOSE BUTTON. TO
NORMALIZE MAINTENANCE MODE
NORMALIZE ALL MAINTENANCE
CONTROLS FIRST.

PNMT

38

NEC
NECITR-YTC
ART-MAR/04 V02

MAINTENANCE

THIS CONTROL CAN CHANGE THE TX


FREQUENCY OF ODU1 OR ODU 2 OF THE
SELECTED NE. WHEN THE TX FREQUENCY IS
CHANGED CORRESPONDING RX FREQUENCY IS
AUTOMA TICALLY DISPLA YED. THIS CONTROL
MAY INTERRUPT THE TRAFFIC.

No.2
OFF"
OFF

Off
7443.000 MHz

RXFreq~ency
~

I.

ATPCManUal'

7282.000MHz
.

OFF

'-'--''''''''''

u
I!

Execute

,Close

CLICK THE TX FREQUENCY BUTTON ON CH1 OR


CH2 ON THE MAINTENANCE WINDOW TO OPEN
THE TXlRX FREQUENCY CONTROL WINDOW.
CHANGE THE TX FREQUENCY AND CLICK
EXECUTE TO IMPLEMENT THE MAINTENANCE
CONTROL.

ATPC ManuaPNo.OO1
THIS CONTROL SET THE A TPC CONTROL TO
MANUAL AND ADJUST THE OUTPUT POWER

'''-''''-''''''''''''''-''-''~

CLICK THE AT PC MANUAL BUTTON OF CH1 OR


CH2 ON THE MAINTENANCE WINDOW TO OPEN
THE ATPC MANUAL CONTROL WINDOW. SELECT
THE ATPC MANUAL ON/OFF. IF ON SELECT THE
REQUIRED ATT TO TX THE REQUIRED OUT
POWER. THEN CLICK EXECUTE TO IMPLEMENT
THE MAINTENANCE CONTROL.
TO CLOSE ANY MAINTENANCE CONTROL WINDOW
CLICK CLOSE BUTTON. TO NORMALIZE
MAINTENANCE MODE NORMALIZE MAINTENANCE
CONTROLS FIRST.

PNMT

39

NEC

AUX I/O WINDOW - MONITOR/CONTROL

NECITR-YTC
ART-MAR/04 V02

AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE
PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS
ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.
CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX 110TAB TO
VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY

~.

CONFIGURE CONTROL RELAY OUTPUTS


CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE
AND CONTROL THE
EXTERNAL CONTROLS
.
.
...

ENTER THE NAME TO


APPEAR FOR
SELECTED CONTROL
ITEM ( UP TO 32
CHARACTERS)
ENTER THE LABEL FOR
EACH CONDITION
EVENT ON AND EVENT
OFF

"(

ENTER THE SELECTED EXTERNAL ALARM NAME,


(UP TO 32 CHARACTERS)
CONFIGURE ALARM INPUTS
CLICK THE INPUT 1-6
BUTTONS TO CONFIGURE
THE EXTERNAL ALARM

ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND


EVENT OFF.

SELECT THE CONDITION FOR


ALARM, EVENT ON OR EVENT
OFF

-I
X.733 ALARM/SEVERITY

EXTERNAL MONITORING ITEMS


CAN BE DEFINED AS ALARMS OR
AS STATUS CHANGE.
CLICK EXECUTE TO CARRY
OUT THE CHANGE

SETTING

CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW

PNMT

40

NEC

RELAY CONFIGURATION

NECITR-YTC
ART-MAR/04 V02

CONFIGURING THE TWO PARALLEL INTERFACE CONNECTORS, ALM AND ALM/AUX CAN BE CARRIED OUT FROM THIS MENU. ALTOGETHER 8 RELAY
OUTPUTS (RL4 TO RL11) CAN BE CONFIGURED FOR OUTPUTTING EQUIPMENT ALARMS. OUT OF THE 8 RELAYS, FOUR CAN BE CONFIGURED TO
CONTROL EXTERNAL HOUSEKEEPING EQUIPMENT.
II RL01 TO RL03 ARE ASSIGNED TO MAINT, PS ALM AND CPU ALM AND CANNOT BE
CHANGED.
II
Alarm I Status I Control
~nput-1
In

Inpul-2
Inpul-3
Inpul-4
Inpul-5
Inpul-6

Relay Configuration

RL08 TO RL11 CAN BE ASSIGNED TO THE FOUR HOUSE KEEPING CONTROL


OUTPUTS. IF THE RELAYS ARE NOT ASSIGNED TO OUTPUT HOUSE KEEPING
CONTROL, THEY CAN BE ASSIGNED TO OUTPUT EQUIPMENT ALARMS.

II RL04 TO RL07 CAN BE ASSIGNED TO ABOUT 23 EQUIPMENT ALARMS.


II MORE THAN ONE ALARM CAN BE ASSIGNED TO A RELAY

~ CLICK THE RELAY


CONFIGURATION
BUTTON IN THE AUX 1/0
WINDOW TO OPEN
RELAY CONFIGURATION
SETTING WINDOW

RelavConllQ@rt!ori

SELECT THE NUMBER OF HOUSE KEEPING


CONTROLS OR SELECT DISABLE. IF HK IS
INDICATED UNDER RL08 TO RL11 THEY ARE USED
FOR HK CONTROL IF NOT THEY CAN USED FOR
ALARMS.

RL04 TO RL07 CAN BE ASSIGNED ANY


EQUIPMENT ALARM BY CLICKING ON THE
BUTTON INTERSECTING THE ALARM ROW
AND RELAY COLUMN. THE SELECTED
BUTTON WILL CHANGE COLOR TO GREEN.

CLICK EXECUTE TO CARRY OUT THE CHANGES


PNMT

41

NEC
NECITR- YTC
ART-MAR/04 V02

CTRL & VERSION WINDOWS

CLICK THE VERSION TAB TO DISPLAY THE VERSION


INFORMATION WINDOW FOR THE SELECTED NE.

CLICK THE CTRL SYMBOL ON THE BLOCK DIAGRAM OR


THE CTRL TAB TO DISPLAY THE CTRL WINDOW FOR
THE SELECTED NE.

G8223R
8/30/01
004037

18I\OXt;~1

"'"'5'fi'1O

ill
Alarm
t=ji;jii,Calendar". 'I

MAININTFC'
G7S97A
3/7/02
004324

Control

Ready

DatefTime

G8223R
9/14/01
004038
0010
2.13

VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE,


SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER
ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED
NETWORK ELEMENT.

CONFIGURATION AND SETTING OF THE PASOLINK


MANAGEMENT CONTROL IS PROVIDED IN THIS WINDOW.

PNMT

42

NEC

DATE TIME SETTING

NECITR-YTC
ART-MAR/04 V02

DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENT'S PM CTRL CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
[CTRL WINDOW]
t

Control
DatelTime

CPU Reset

TO DISPLAY THE CURRENT DATE/TIME


STORED IN THE NE, SELECT GET
DATE/TIME AND CLICK EXECUTE.

Download (PC CTRl )


Configuration File
Program File
EquipmenIConfig. File

THE CURRENT DATE/TIME STORED IN


THE PM CARD, IS DISPLAYED.

CLICK DATEITIME
BUTTON IN THE CTRL
WINDOW TO OPEN THE
DATE/TIME SETTING
CONTROL WINDOW

TO CHANGE THE PM CARD DATE TIME SETTING,


SELECT SET DATE/TIME.

TO CHANGE THE PM CARD DATE TIME SETTING,


SELECT SET DATEITIME.
TO DISPLAY AND SET THE DATE/TIME SET IN THE
PNMT PC TO THE NE, SELECT DISPLAY PC TIME BOX
AND CLICK THE EXECUTE BUTTON.

CHANGE THE DATE /TIME SETTING AS REQUIRED,


CLICK THE EXECUTE BUTTON.

PNMT

43

NEC

DOWN LOAD CONFIGURATION FILES


[CTRL WINDOW]

NECITR-YTC
ART-MAR/04 V02

THIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE NETWORK CONFIG TOOL TO
THE CTRL IN THE SELECTED f':IETWORK ELEMENT. THERE ARE TWO FILES CREATED FOR EACH NE, MIB.CFG
CONTAINS THE IP ADDRESS OF THE NE AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION. THE
NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK NETWORK WHERE NE IS LOCATED.
CLICK THE CONFIGURATION FILE BUTTON UNDER THE DOWNLOAD (PCCTRL)
CTRL WINDOW, TO OPEN THE DOWNLOAD CONFIGURATION FILE WINDOW.

IN THE

DOWN LOAD
SELECT EACH CONFIG FILE ONE BY ONE FROM
THE TYPE WINDOW
BROWSE AND SELECT THE PATH/LOCATION TO
THE FILE SELECTED IN THE TYPE WINDOW.
(

CLICK EXECUTE BUTTON TO DOWN LOAD THE


SELECTED CONFIG FILE..
REPEAT THE DOWNLOAD PROCEDURE FOR THE
OTHER CONFIG FILE..
A MESSAGE WINDOW INDICATE THE STATUS OF
THE DOWNLOAD OPERATION AND IT WILL CLOSE
AUTOMATICALLY ONCE THE OPERATION IS OVER

..

UPDATE
AFTER THE SUCCESSFUL DOWN LOAD OF
THE CONFIGURATION FILES. CLICK
UPDATE BUTTON. UPDATE
CONFIGURATION FILE WINDOW OPENS.

WAR.N.lN.G..

SELECT THE APPROPRIATE BOX FOR THE


TYPE OF CONFIGURATION FILE(S) THAT
WILL BE UPDATED.

MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN


LOADED TO THE CTRL IN THE CORRECT NE. INCORRECT
CONFIGURATION FILE WILL LEAD TO CTRL OR NETWORK
FAILURE

CLICK EXECUTE BUTTON TO START THE


UPDATE OPERATION..

MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED


THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE
THE CTRL WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE
CTRL FAILURE.

WHEN UPDATING, PM CTRL TO PM CTRL


COMMUNICATION WILL BE LOST WHEN CTRL
INITIALIZES TO THE NEW SYSTEM
CONFIGURATION. DURING THIS TIME PNMT
CONNECTION TO THE PASOLINK WILL BE LOST
BUT WILL AUTOMATICALLY BE RECONNECTED
AFTER THE PM CTRL RESETS

CLICK CLOSE BUTTON WHEN DONE

PNMT

44

NEC
NECITR-YTC
ART-MAR/04 V02

DOWN LOAD PROGRAM FILE


[CTRL WINDOW]
.

THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE CTRL.


THIS OPERATION AFFECTS ONLY THE PM CTRL TO PM CTRL COMMUNICATION.
AND WILL NOT DISRUPT THE RADIO LINK.
CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PCCTRL) IN
THE CTRL WINDOW.

SELECT THE MODULE THE


APPLICATION PROGRAM IS TO BE
DOWNLOADED.

CTRL CAN BE RESET USING THIS


FUNCTION

ENTER THE PATH TO THE


PROGRAM FILE TO BE
DOWNLOADED OR CLICK BROWSE
TO LOCATE THE PROGRAM FILE.

CLICK THE CTRL RESET BUTTON ON THE


CTRL WINDOW.

CLICK THE EXECUTE BUTTON TO


START DOWNLOAD OPERATION'
CLICK ON THE CPU RESET
BUTTON TO SWITCH TO THE NEW
PROGRAM FILE

DOWNLOAD PROGRESS IS
INDICATED HERE

SELECT WITH ROM (PROGRAM)


SWITCHING OPTION IF YOU WANT TO
SWITCH TO A NEWLY DOWNLOADED
CTRL PROGRAM FILE

CLICK EXECUTE BUTTON TO


RESET THE CPU

RESETTING THE CTRL WILL NOT AFFECT THE


TRAFFIC. THE CONNECTION TO THE
SELECTED PASOLINK WILL BE LOST FOR FEW
MINUTES AND WILL BE RECONNECTED

AUTOMATlCALLY.

PNMT

WARNING
MAKE SURE THAT THE CORRECT
PROGRAM FILE IS DOWNLOADED
TO THE CTRL. INCORRECT
PROGRAM FILE WILL LEAD TO
CTRL FAILURE.

45

NEC

UPLOAD CONFIGURATION FILE


[CTRL WINDOW]

NECITR- YTC
ART-MAR/04 V02

THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM


THE CTRL OF THE SELECTED NE TO THE PNMT PC.
WHEN EQUIPMENT IS CONFIGURED (AUXILIARY ALARMS, BER
THRESHOLD ETC.) TAKE A UPLOAD OF THE EQUIPMENT
CONFIGURATION FILE TO THE PNMT PC.
,',""'0:1

Browse...I

Execute
Upload Configuration File - No.OO1'

Close

WHEN THE PASOLINK IDU FOR A SITE IS REPLACED FOR SOME


REASON THE EQUIPMENT CONFIGURATION FILE CAN BE
DOWN LOADED TO CONFIGURE THE REPLACED IDU.

CLICK THE CONFIGURATION FILE


UNDER THE UPLOAD
(CTRLPC) TO OPEN THE
UPLOAD CONFIGURATION FILE
WINDOW.

:~

111iI':'Ti1r.F.r.I"I!IJ'"I!"'1o11fi1i11ml;-;~~."
F~e
C:\Documents

Execute

and Settings\O

...

Header Information

SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE


WINDOW., MIB CONFIG OR NETWORK CONFIG.

NE NAME-''No.002''
IP ADDRESS-"172. 18.0.2"
EQUIPMENT TYPE.''Peso+ST

M.1 ,.

SUBTYPE-';;'"
DATE-"2003/09/03

1 3:55:51"

ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN
THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF
NECESSARY.
CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE
WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATIQN,
AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..
AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE
THE WINDOW.

PNMT

Execute

Update...

Close

AFTER DOWN LOADING, CARRY OUT THE UPDATE OPERATION

46

NEC

EVENT & PERFORMANCE DATA

NECITR-YTC
ART-MAR/04 V02

r0

nnnn

n__n__nnnnnn

n_nnnnnn

000000__00

00

00--00__00_0000____-

0
0

~~

Status Change
Alarm Occurrence
Alarm Recovery

i:
.

i
0

'

i
Link
Performance
ES

Controls

SES

Parameter Change

~~~
OFS

!,
i

0
0

.
'n_n

Oldest

300

nnn--_nn__nn

ii

'81:

!
.

0 mm

mmmm

'81:

~.,.

00

':

~;:UllJi

00_--'

0000

i
i

"'"

'~':_--'--"

III

,..

00'-

::::::::::::::::::::::
n

nnn__nn

~,_~'/ ~--nn_,
n_.'

atest 1

IDU (PM Card)

nn_nJ

i0
:

I0

i
0

EVENT LOG AND PERFORMANCE DATA ARE UPLOADED TO THE PNMT


EACH TIME EVENT LOG AND PERFORMANCE MONITOR ARE SELECTED.

PNMT

47

NEC

EVENT LOG

NECITR-YTC
ART-MAR/04 V02

. A MESSAGE WINDOW

SHOWS THE PROGRESS OF


THE UPLOAD

CLICK ON THE EVEN LOG IN


THE NE SPECIFIC MENU BAR
TO UPLOAD THE EVEN LOG
ITEMS FROM THE SELECTED
NE.
EVENT LOG VIEW WINDOW SHOWS
ALARM EVENTS, COMMAND EVENTS
AND STATUS CHANGES.

DIFFERENT COLORS SHOWS THE


TYPE OF EVENT.
EVENT LOG IS PRESENTED IN A TABLE
FORM SHOWING THE DATE OF THE
EVENT, THE ITEM THAT TRIGGERED
THE EVENT AND THE STATUS
CHANGE.

LICK FILE-UPLOAD TO REFRESH THE EVENT


LOG DISPLAY
CLICK FILE-SAVE AS TO SAVE THE EVENT
LOG TO
CLICK FILE-PRINT TO PRINT THE EVENT
LOG INFORMATION

PNMT

48

NEC

LINK PERFOR'MANCE MONITOR

NECITR- YTC
ART-MAR/04 V02

NE SPECIFIC MENU BAR

,.

THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED


ACCORDING TO THE G.826 RECOMMENDATIONS.

CLICK ON THE LINK PERFORMANCE MONITOR IN THE NE


SPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF
THE PASOLINK TO BE MONITORED.
InIIItrn~i!3" ",,,,",,
fio ','~
:!f ':t)'c"-"","'c"'"''''''''''

: rnm,""","'''111'
-101>'1
"-'-_m""."m.

",M'-{F-'~"'~,

',"""",."._.m.,._.""m

""-.-"'M""""''''''''.''"m"",_'m.

",,-

"""t',cc,','

..
f\8ER[DMRFI2.2E-7

OFS

OUT OF FRAME SECONDS

ES
SES
UAS
BBE

ERROR SECONDS
SEVERELY ERROR SECONDS
UNAVAILABLE SECONDS
BACKGROUND BLOCK ERRORS

CURRENT BER VALUE IS SHOWN IN THIS FIELD


Thre.hold
15mln
Occur
Retover
Occur
900
90
900
90
;;;; "'t-650
900
90
65535
650
900
90
65535
650
65535
650
65535
650
..-"..."._.m."

THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW


INDICATES THE OCCURRENCE
OF PERFORMANCE ITEMS
EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES
CAN BE SET IN THRESHOLD WINDOW.

m_"" ""...._m__._--.".

15mn
Octur
Recoy,
900
90
900
90
900
90
900
90
65535
650

D
OCtu'
65535
65535
65535
65535
65535

Rec",r
650
650
650
650
650

THRESHOLD VALUE SETTING


CLICK THE THRESHOLD BUTTON MUX OR DMR TO OPEN THE
THRESHOLD SETTING WINDOW.
SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE
TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN
THE ALARM RECOVER IN THE APPROPRIATE FIELD.
AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO
ACTIVATE THE NEW SETTING.

!~

Exec~~e
"t'<

I
'

CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..

PNMT

49

NEC

LINK PERFORMANCE

THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF


THE LAST.8 DAYS.

CLICK ON THE DETAIL BUTTON IN THE LINK PERFORMANCE


MONITOR WINDOW TO DISPLAY THE WEEKLY DETAIL
WINDOW.

..."

MONITOR

NECITR-YTC
ART-MAR/04 V02

~.

THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE


TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY
DATA FOR THAT SPECIFIC DATE..

THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THE


DETAILED 15MIN PERFORMANCE DATA
lr-\1IlTj1;Ji!IJ.~

.iiilil!li~!!!i!llii~CLICK FILE - UPLOAD TO REFRESH THE DATA


0
0

CLICKFILE-SAVE AS TO SAVETHE DATAIN TEXTFORMAT

0
0

CLICK FILE - CLOSE TO EXIT THE WINDOW

0
0

PNMT

50

NEC
NECITR-YTC
ART -MAR/04 V02

PNMT LAN CONNECTION


t
,t

"

IT IS POSSIBLE TO CONNECT THE PNMT PC TO THE PASOLINK


CLUSTER BY LAN CONNECTION TO THE PNMS LAN PORT IN THE IOU
OR THROUGH A ROUTER BY CONNECTING TO THE NMS SERIAL
PORT OF THE CPM.
SET THE APPROPRIATE IP ADDRESS AND THE GATEWAY ADDRESS
IN PNMT PC ACCORDING TO THE CPM OR ROOT NE IP ADDRESS
AND GATEWAY ADDRESS SETTING.

PNMT
LA-1\;'

Defauli

OPEN THE ConnectList_samp.ini FILE IN THE PNMT FOLDER AND


MODIFY THE DIALUP AND ETHERNET ENTRIES.

~fa1h't

G.1teway

GaTeway

192.168.1.1124

Fie Edt Formi: IJiew Help


,

\X!l1

192.16U.100/14

F:\1vIT

,...-

[Dialup]
Entryl=Pnmt

No. 001

No. 002

172.18.0.1

172.18.0.2

No. 003

No. 004

~o. 005

172.18.0.3 172.18.0.4 172.18.0.5

No.,006
m.1806

Cro~~Cable 01'Su'aight Cable ,oia


Hub

[Ethernet]

Enti'y1=~O.OtJ1,172.18.0.1
!':\'"rr

SAVE THE FILE AS ConnectList.ini


Conneclion

IA'i pc:t
192.168.
U(IQ'2~

Lisl Seclioni,':Y,' <"'f..;.'. ',,cc EJ

Debalt G,tew;ry
192.168.L253i2~

START THE PNMT AND FROM THE


CONNECT LIST SECTION WINDOW
SELECT ETHERNET AND THE NETO
BE CONNECTED.

~onnect

,'Ix~'

F""".,2

No. 002

Nc>.003

No. (fJ4

No. 005

Nc>.006

171,13.0.1 172.18.0.2 171.J8.0.1 171.IS,OA J72.18.0.5 172.18,0.6

SEE THE PNMT-SETTING MANUAL FOR LAN CONNECTION FOR MORE DETAILS

PNMT

51

NEC

PNMT LAN CONNECTION


IT IS POSSIBLE TO CONNECT SEVERAL PASOLINK CLUSTER TO THE
PNMT PC LAN PORT BY CONNECTING THE PASOLINK CLUSTERS
THROUGH A HUB AS SHOWN IN THE DIAGRAM. PNMT WILL
CONNECT TO ONE CLUSTER AT A TIME BY SELECTING THE
CLUSTER TO BE CONNECTED FROM THE CONNECT LIST SECTION
WINDOW WHEN THE PNMT START-UP.

....
R1- 001
Rl_002
R1_003
RUA'14
Xl_CO;
Rl_Cl)6
172.18.0.1 172.18.02 172.18.0.3 172.18.04 172..18.05 17218.0.6
P!'\1dSL!!.Npoli

Fie Edt Formal: IJiaw Help


.m"",.,..".".,... ,. ... .,
,.. ..

192.168I.2V

[Dialup]
Entryl=Pnmt

Entry2=R2_001,172.18.1.1
Entry32=R32_001,172.18.31.1

V02

IRf;uCt Gateway

MODIFY THE ConnectListini FILE IN THE PNMT FOLDER ACCORDINGLY

[Ethernet]
Enti-y1=R1_"001,f'T2.18.0.1

NECITR-YTC
ART-MAR/04

IRf;;lCt Gate\vay
192.168.1.10C/24

R2_001
R2_C02R2_003
172.l8.1.1 172.18.1.2 l'i2J3.L3:

LIST THE NE NAMES AND THE IP


ADDRESS OF THE ROOT OR CPM NEs TO
BE'CONNECTED. THE NUMBER OF
ETHERNET ENTRIES IS UP TO 32.

....
R2_004

.
.
.
.

172.lS.1.4

R2_005

F...:U)06

172.18J5

172.18J.6

...
I

Di!f;;ult Gat'.vay

CREATE A ROUTE COMMAND BATCH (ROUTE_SAMPLE.BAT) FILE TO ADD


THE ROUTING TABLE IN PNMT PC.
Route add 172.18.0.0mask 255.255.255.0192.168.1.1
Route add 172.18.1.0mask 255.255.255.0192.168.1.2
Route add 172.18.31.0 mask 255.255.255.0
DOUBLE-CLICK THE ROUTE_SAMPLE.
ACTIVATE THE ROUTING TABLE.

192.168.1.32

BAT FILE TO

....
RJ2_G()1
J72JS.3l.J

PNMT
Ltu'\ pDl1

R32_002
172.18.31.2

R31_003
17118.31.3

F32_0C4
172.18.31.4

R32_005
172.183] j

R32_006
172.13.31.6

192.168.1.100/24

R1 001
R2-001
R3-001
R{OOl
R5'OOl
I=ViTji
R7 001
RB'OO1
R9-001
Rl0_001

START THE PNMT AND


FROM THE CONNECT
LIST SECTION WINDOW
SELECT ETHERNET AND
THE NE TO BE
CONNECTED.

172.18.D.1
172.18.1.1
172.18.2.1
172.18.3.1
172.18.4.1
~1iIr:...,
172.18.6.1
172.18.7.1
172.18.8.1
172.18.9.1..:J
Exit

"

Rmtter2

P?{hIT

':'
'

I
PNMT

52

Das könnte Ihnen auch gefallen