Beruflich Dokumente
Kultur Dokumente
00813-0100-4762, DS-4011
Flow-117
Mass ProBar
125
125
126
126
Fe a tur es
FEATURE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 127
BENEFIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 127
I n sta l l a ti o n
(F ol l ow th e P I P E S Pl a n fo r Q u al i ty I ns ta l l a t io n. )
PIPE O RIENTATION - - - - - - - - - - - - - - - - - - - - - - - - - - INSIDE PIPE DIAMETER - - - - - - - - - - - - - - - - - - - - - - - PIPE PENETRATION - - - - - - - - - - - - - - - - - - - - - - - - - - ELECTRONICS MOUNTING - - - - - - - - - - - - - - - - - - - - - STRAIGHT RUN - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
128
128
128
129
129
S i zi n g an d H ow to O rd er
1. CHOOSE A MOUNTING M ETHOD - - - - - - - - - - - - - - - 2. CHOOSE A SENSOR SIZE - - - - - - - - - - - - - - - - - - - - 3. VERIFY MODEL AND SENSOR SIZE- - - - - - - - - - - - - - 4. CHOOSE THE MODEL OPTIONS - - - - - - - - - - - - - - - - 5. VERIFY PROCESS AND PIPE INFORMATION - - - - - - - - -
Flow-118
131
132
133
135
136
Rosemount Inc.
MODEL MBR+15S/16S
MODEL MBR+25S/26S
MODEL MBR+35S/36S
MODEL MBR+45S/46S
-----------------------------------------------------------------------------------------
137
139
142
145
O rde ri n g I n fo rm a ti o n M o d el MB F
MODEL MBF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - MODEL MBF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - MODEL MBF+25H/26H - - - - - - - - - - - - - - - - - - - - - - MODEL MBF+25M/26M- - - - - - - - - - - - - - - - - - - - - - MODEL MBF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - MODEL MBF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - MODEL MBF+45H/46H - - - - - - - - - - - - - - - - - - - - - - MODEL MBF+45M/46M- - - - - - - - - - - - - - - - - - - - - - -
153
156
159
162
165
168
171
174
Mass ProBar
O rde ri n g I n fo rm a ti o n M o d el MB R
O rde ri n g I n fo rm a ti o n M o d el MN T
MODEL MHF+15S - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+25S - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+25H - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+25M - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+35S - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+45S - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+45H - - - - - - - - - - - - - - - - - - - - - - - - - MODEL MHF+45M - - - - - - - - - - - - - - - - - - - - - - - - - -
213
216
219
222
225
228
231
234
S p ec i fi c at i on s
Flow-119
MASS PROBAR
Flowmeter
Mass ProBar
MASS PROBAR
FLOWMETER
REINVENTING DP
FLOW MEASUREMENT
By combining integrated
electronics with insertion
flowmeter technology,
Mass ProBar provides the
lowest total cost of any precision
flowmeter. Installation costs are
reduced by the measurement of
three process variables through a
small tap into an existing pipe
and there is no plumbing required
between the electronics and
the sensing element. The
multivariable electronics reduce
hardware requirements. Due to
the aerodynamic shape of the
sensing element, the Mass
ProBar flowmeter provides low
operating costs. In addition, the
insusceptibility of the sensor to
warp, wear, and plugging and the
stability of the electronics provide
low maintenance costs.
Flow-120
Rosemount Inc.
Performance
MASS PROBAR FLOWMETER
Mass ProBar
Accuracy 1.3% of
Mass Flow Rate, Turndown 8:1
The Mass ProBar flowmeter provides high accuracy
mass flow over a wide operating range by
dynamically compensating flow equation variables
in real time, including thermal expansion effects,
density, and gas expansion effects. The fully
compensated flow equation reduces the sources of
traditional DP flow uncertainty, thereby providing
a more accurate flow measurement.
Compared to Non-Compensated
Flow Measurement
Compared to Traditional
Compensated DP Flow Measurement
Traditionally, DP flow has been calculated in a
DCS or flow computer using a simplified mass
flow equation. In simplified DP mass flow
measurements, a constant is used to represent
many of the terms of the flow calculation.
The Mass ProBar flowmeter dynamically
compensates for changes not only in density, but
also in other terms that are considered constant
in typical mass flow compensation. In fact, only
the units conversion factor is constant. The other
terms (thermal expansion factor, pipe ID, and gas
expansion factor) are functions of static pressure
and temperature. The simplified flow equation
cannot compensate for changes in these terms
resulting in unrecorded errors in the calculated
flow rate. The Mass ProBar flowmeter uses a
fully compensated equation for mass flow.
Flow
The Model 3095 dynamically calculates flow coefficients.
Qmass = KFaaYaD2 DP ().
Traditional flow uncertainty is eliminated.
C
Flow
Flow-121
Mass ProBar
Multivariable electronics
measure pressure,
temperature, differential
pressure, and calculate true
mass flow rates. Access to all
measurements is available
through HART or through an
optional splitter that provides
access to all variables
via 4-20mA loops.
Temperature
Integral
3-Valve
Manifold.
Patented
Pak-Lok
mounting
for safe
installation
or optional
flange
mounting.
Static Pressure
Static pressure is measured off the high side of
the Mass ProBar sensor. The Mass ProBar
electronics calculate the portion of the high
side pressure sensed that would be equal to
the true pipe static pressure.
Differential Pressure
Differential pressure is sensed utilizing the patented
Diamond II+ Annubar primary flow element
DP sensing technology. The Mass ProBar
flowmeter senses the entire flow profile and
produces an accurate DP signal.
The Diamond II+ design provides a fixed separation
point for linear, repeatable performance.
The Mass
ProBar
flowmeter
senses DP, T,
and P through
one process
tap and
computes fully
compensated
mass flow.
Flow-122
CALIBRATED MASS
PROBAR FLOWMETER
The Mass ProBar flowmeter can be calibrated
over an 8:1 Reynolds Number range to provide an
improved accuracy. This patented technology
eliminates percent to full scale errors
associated with traditional compensated DP
mass flow measurement.
Rosemount Inc.
Benefits
Three Process Variables
Measured with One Device
Mass ProBar
COMPENSATED
MASS FLOW
Temperature
Pressure
Process taps
Fittings & tubing
Valves
Manifold
Adapter unions
Transmitter mounting
Welding
Leak points
Traditional
Mass ProBar
4
20
5
1
2
3
50 linear inches
36
1
0
0
Integral
0
0
4 linear inches
6
Mounting hardware
Transmitters
Manifold, valves,
tees & bracket
Weld (mounting)
Fittings & Tubing
Mass ProBar Flowmeter
Wiring
Startup (Cal/Config)
Flow-123
Mass ProBar
Non-plug design
No moving parts
Combining three process variables and the
mass flow calculation into one device
reduces chance of mechanical breakdown
Optional EA software and/or HART 275
handheld communicator allow easy
maintenance and diagnostic functions
Reliability
8
(200mm)
12
(300mm)
30
(750mm)
Flow-124
I SO
9001
4
(100mm)
Over
30
Sale
s&S 0
ervic
e
Cent
ers in
Rosemount Inc.
Mass ProBar
Cyclopropane
Isopropanol
n-Heptane
Acetone
Divinyl Ether
Melamine
n-Hexane
1-Decanol
1-Dodecene
Acetonitrile
Ethane
Methane
n-Octane
1-Dodecanol
Acetylene
Ethanol
Methanol
n-Pentane
1-Heptanol
Acrylonitrile
Ethylamine
Methyl Acrylate
Oxygen
1-Heptene
Air
Ethylbenzene
Pentafluorothane
1-Hexene
Allyl Alcohol
Ethylene
Phenol
1-Hexadecanol
Ammonia
Ethylene Glycol
m-Chloronitrobenzene
Propane
1-Octanol
Aniline
Ethylene Oxide
m-Dichlorobenzene
Propadiene
1-Octene
Argon
Fluorene
Neon
Pyrene
1-Nonanal
Benezene
Formic Acid
Neopentane
Propylene
1-Nonanol
Benzaldehyde
Formaldehyde
Nitric Acid
p-Nitroaniline
1-Pentadecanol
Benzyl Alcohol
Furan
Nitric Oxide
Styrene
1-Pentanol
Biphenyl
Helium-4
Nitrobenzene
Sorbitol
1-Pentene
Carbon Dioxide
Hydrazine
Nitroethane
Sulfer Dioxide
1-Undecanol
Carbon Monoxide
Hydrogen
Nitrogen
Toluene
1,2,4-Trichlorobenzene
Carbon Tetrachloride
Hydrogen Chloride
Nitromethane
Trichloroethylene
1,1,2-Trichloroethane
Chlorine
Hydrogen Cyanide
Nitrous Oxide
Vinyl Acetate
1,1,2,2-Tetrafluoroethane
Chlorotrifluoroethylene
Hydrogen Peroxide
n-Butane
Vinyl Acetylene
1,2-Butadiene
Chloroprene
Hydrogen Sulfide
n-Butanol
Vinyl Chloride
1,3-Butadiene
Citric Acid
Isobutane
n-Butyraldehyde
Vinyl Cyclohexane
1,3,5-Trichlorobenzene
Cycloheptane
Isobutene
n-Butyronitrile
Water
1,4-Dioxane
Cyclohexane
Isobutylbenzene
n-Decane
1-Butene
1,4-Hexadiene
Cyclopentane
Isopentane
n-Dodecane
1-Decene
2-Methyl-1-Pentene
Cyclopentene
Isoprene
n-Heptadecane
1-Decanal
2,2-Dimethylbutane
Flow-125
Mass ProBar
FIGURE 14. Engineering Assistant Steam Setup Screens.
EA saves both time and money. Engineering time is saved because the plant engineer does not have to
calculate viscosities, densities, flow equations, and related mass flow calculations. Market research
estimates that users can expect to save four to six hours of engineering time per flow application with EA.
One of the dynamic capabilities of the EA is the compressibility and viscosity table. After identifying the
liquid or gas and entering the operating pressure and pressure ranges, this table is automatically populated
with a complete set of fluid data over the specified temperature/pressure range.
Another feature of EA is the configuration speed. With so much built-in to EA, a plant engineer can
quickly get a process up and running. Later, after hands-on experience with the process, an engineer
can easily modify the Mass ProBar configurations and density to improve product quality and to
reduce by-product formation.
CH 3
CH 2
CH 1
DP
MASS FLOW
Flow-126
Rosemount Inc.
Features
FEATURE
Integral RTD
BENEFIT
A single pipe
penetration allows
measurement of mass
flow, including
temperature.
FIGURE 16. Integral RTD.
Mass ProBar
Pak-Lok Mounting
Pak-Lok mounting seals and secures the Mass
ProBar flowmeter firmly against the inside
opposite wall simply and without high torque
requirements. This design safely retains the
sensor under high process pressures. It also
provides additional structural support by
placing the sensor in compression.
Elbow Mount
Mass ProBar flowmeter can be installed two
pipe diameters from the centerline of an
elbow and still provide good accuracy and
repeatability: +3% without calibration.
Flow-127
Installation
Mass ProBar
P ipe orientation
DP ( p )
I nside diameter
P ipe penetration
E lectronics mounting
S traight run
Pipe Orientation
The flowmeter sensor must be installed in the
proper orientation relative to the pipe and the fluid
measured. This must be specified at time of order
placement. For gases, the electronics must be
mounted above the pipe (Figure 22). For liquid
and steam, the electronics must be mounted
below the pipe (see the I/O manual for detailed
installation instructions).
50
30
Pipe Penetration
The sensor mounting hole must be smooth and the
correct size to avoid disturbing the flow profile
(Figure 24). Drilling is the only acceptable method to
properly prepare the mounting hole.
50
30
80
Gas Installation
Flow-128
Electronics Mounting
Straight Run
Without
Vanes
After an elbow
10
28
30
After an expansion
18
After a constriction
12
Location
Mass ProBar
Rosemount Inc.
Flow-129
Mass ProBar
Flow-130
Rosemount Inc.
MBR
Mounting Method
Threaded, Pak-Lok.
Pipe Sizes
2- to 72-in. (50 mm to 1800 mm).
Mounting Method
Flanged.
Pipe Sizes
2- to 72-in. (50 mm to 1800 mm).
MNT
MNF
Mounting Method
Threaded In-Line.
Pipe Sizes
- to 2-in. (25 mm to 50 mm).
Mounting Method
Flanged In-Line.
Pipe Sizes
- to 2-in. (25 mm to 50 mm).
MHT
MHF
MNW
Mounting Method
In-Line Welded.
Pipe Sizes
in. to 2 in. (25 mm to 50 mm).
FIGURE 31. High-Pressure Threaded Flo-Tap. FIGURE 32. High-Pressure Flanged Flo-Tap.
Mounting Method
Thread Flo-Tap for pressure equivalent
to ANSI Class 600 Flanges.
Pipe Sizes
2- to 72-in. (50 mm to 1800 mm).
Mounting Method
Flanged Flo-Tap for pressure
equivalent to ANSI Class 600 Flanges.
Pipe Sizes
2 in. to 72 in. (50 mm to 1800 mm).
Flow-131
Mass ProBar
Sensor
Pipe Sizes
15/16
25/26
35/36
45/46
Flow-132
3. To convert U.S. to
metric units.
lb hr 2.205 = kg hr
3
SCFH
NM H = -----------------35.37
Rosemount Inc.
MNT
MNF
Mass ProBar
Sensor 10
MNW
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
.5
180.52
1500
1521.2
180.52
1500
1521.2
180.52
1500
1521.2
.75
307.79
1500
2626.2
307.79
1500
2626.2
307.79
1500
2626.2
498.82
1500
4204.1
498.82
1500
4204.1
498.82
1500
4204.1
1.25
765.68
1180
6451.2
765.68
1180
6451.2
765.68
1180
6451.2
1.5
902.04
884
7654.8
902.04
884
7654.8
902.04
884
7654.8
1174.9
552
10070
1174.9
552
10070
1174.9
552
10070
Sensor 15
MBR
Sensor 16
MBF
MHF
MBR
MBF
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
1236.1
611
10672
502.91
84.3
4020.8
1555
967
13296
1236.1
611
10672
1322
699
11387
2.5
1531.9
451
13108
639.74
66.9
5111.1
1886.4
699
16190
1531.9
451
13108
1641
529
14161
2010.5
314
16935
859.71
50.5
6858.1
2408.7
478
20768
2010.5
314
16935
2175.3
380
18585
3.5
2408.7
246
20083
1046.1
41.7
8336.2
2852.6
369
24475
2408.7
246
20083
2639.5
305
22308
2816
199
23291
1237.1
35.1
9849.7
3331.3
294
28195
2816
199
23291
3126.9
253
26200
3723.8
137
30434
1663.7
25.6
13223
4364.9
195
36214
3723.8
137
30434
4213.3
180
34814
Sensor 25
MBR
Sensor 26
MBF
MHF
MBR
MBF
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
6263.45
1090
53745
2827.2
189
22801
7347.5
1500
62506
6263.4
1090
53745
7047.5
1380
60109
8148.5
747
70042
3798.1
138
30621
10066
1140
85564
8148.5
747
70042
9366.4
987
79961
10088
549
86951
4839.5
107
38950
12299
816
105070
10088
549
86951
11783
749
100880
14100
346
120070 6867.4
71.2
55057
16486
489
141940
14100
346
120070
16570
494
142640
10
18737
235
156510 9125.3
50.2
72913
21270
318
181400
18737
235
156510
22053
348
189510
12
23218
174
191570
11299
38
90092
26142
228
218740
23218
174
191570
27773
263
234550
14
25971
147
213040
12665
32.6
700870
29131
190
241690
25971
147
213040
31411
226
263140
16
30390
116
247520
14829
26.1
117930
33874
147
278210
30390
116
247520
37265
182
309040
18
34880
94.2
282610
17017
21.4
135190
38584
117
314580
34880
94.2
282610
43086
149
354430
20
39558
77.7
319230
19311
17.8
153270
43384
94.5
351770
39558
77.7
319230
49210
124
402350
24
48768
55.7
391340
23901
13
189480
52897
66
425730
48768
55.7
391340
61463
90.6
498150
30
65577
35.6
523390
32211
8.43
255050
70325
41.1
562200
65577
35.6
523390
83933
59.3
674620
36
80406
25.2
639850
39598
6.03
313340
85555
28.6
681520
80406
25.2
639850 103900
42.6
801100
42
95305
18.8
757040
47023
4.53
371910 100650
21
800040
95305
18.8
757040 123750
32
9869905
hw = maximum differential pressure in inches of water column 1.2 in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute 30 in. to 42 in. Sch Std.
PPH = maximum steam flow in pounds per hour 48 in. to 72 in. Actual Id
At standard conditions: Air: 60 F at 14.73 psia
Steam flow at 100 lbs saturated (*hw calculated above 300 F)
Flow-133
Sensor 35
MBR
Sensor 36
MBF
MHF
MBR
Mass ProBar
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
20661
768
177160
9950.2
153
80562
24501
1080
208060
20661
768
177160
24387
1070
207160
10
26823
521
231030
13239
108
106760
31224
706
267130
26823
521
231030
32204
751
275060
12
32883
385
282890
16469
82.3
132370
37485
505
322440
32883
385
282890
39824
570
341660
14
37058
327
315630
18488
70.7
148340
41364
421
356720
37058
327
315630
44625
490
383740
16
43668
258
367050
21690
56.7
173600
48040
325
410760
43668
258
367050
52273
394
450890
18
50338
209
418930
24947
46.6
199290
55095
258
464420
50338
209
418930
60481
324
518860
20
57299
172
473010
28344
38.8
226080
62559
210
521700
57299
172
473010
69596
270
589880
24
71017
123
579670
36548
28.3
279370
76801
146
630850
71017
123
579670
87930
198
732800
30
96282
78.9
777460
47441
18.4
376620
103040
91.1
834910
96282
78.9
777460
121480
130
995350
36
118650
56
952310
58452
13.2
463420
125830
63.3
1012100 118650
56
952310
151120
93.2
1226100
42
141020
41.8
1127500
69564
9.95
551080
148640
46.6
1190200 141020
41.8
1127500 181070
70.3
1460000
48
163400
32.4
1326100
80662
7.76
649630
171330
35.7
1389500 163400
32.4
1326100 211020
54.9
1722900
60
208140
21.1
1676400 102920
5.1
825010
216230
22.8
1744100 208140
21.1
1676400 270800
36.1
2192800
72
253470
14.9
2033100 125280
3.61
1001700 261750
15.9
2094700 253470
14.9
2033100 330970
25.6
2664200
Sensor 45
MBR
PPH
Sensor 46
MBF
MHF
MBR
MBF
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
PPH
SCFM
hw
10
41878
1270
357030
20133
256
164060
45513
1500
385940
41878
1270
357030
45513
1500
385940
12
51142
940
437040
24994
195
203330
59210
1260
501370
51142
940
437040
61288
1350
517620
14
56913
797
487310
28092
168
228160
65325
1050
554920
56913
797
487310
68661
1160
581210
16
66100
630
567710
33012
135
267310
74858
808
638920
66100
630
567710
80698
939
685660
18
75353
511
648900
38019
111
306960
84461
642
723780
75353
511
648900
92738
774
790720
20
85108
422
734630
43418
93.2
349760
94565
521
813020
85108
422
734630
105460
648
902180
24
106480
303
903590
53975
68.2
433030
114620
364
987770
106480
303
903590
130590
475
1123000
30
146170
194
1213100
73415
44.7
586360
156190
226
1307400 146170
194
1213100 178800
313
1532300
36
181760
138
1489400
90648
32.1
722020
192700
157
1587000 181760
138
1489400 226020
226
1897800
42
217210
103
1764700 108240
24.3
860600
229510
116
1871500 217210
103
1764700 273660
171
2266000
48
251110
78.8
2061800 125770
19
1014200 265390
88.6
2183700 251110
78.8
2061800 321370
134
2680200
60
321930
51.5
2615700 160730
12.5
1290800 337470
56.8
2744300 321930
51.5
2615700 416410
88.4
3421600
72
392880
36.3
3171000 195900
8.86
1568100 408770
39.4
3301600 392880
36.3
3171000 511830
62.8
4161900
hw = maximum differential pressure in inches of water column 1.2 in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute 30 in. to 42 in. Sch Std.
PPH = maximum steam flow in pounds per hour 48 in. to 72 in. Actual Id
At standard conditions: Air: 60 F at 14.73 psia
Steam flow at 100 lbs saturated (*hw calculated above 300 F)
Flow-134
MBF
PPH
Rosemount Inc.
Description
Page Numbers
MBR+15/16S
page 137
MBR+25/26S
page 139
MBR+35/36S
page 142
MBR+45/46S
page 145
MBF+15/16S
page 153
MBF+25/26S
page 156
MBF+25/26H
page 159
MBF+25/26M
page 162
MBF+35/36S
page 165
MBF+45/46S
page 168
MBF+45/46H
page 171
MBF+45/46M
page 174
Mass ProBar
page 182
MNF+10S
page 184
MNF+10H
page 186
MNF+10M
page 188
MNW+10S
page 190
MHT+15S
page 198
MHT+25S
page 201
MHT+35S
page 204
MHF+15S
page 213
MHF+25S
page 216
MHF+25H
page 219
MHF+25M
page 222
MHF+35S
page 225
MHF+45S
page 228
MHF+45H
page 231
MHF+45M
page 234
FloTap Models
Flow-135
Mass ProBar
When ordering a Mass ProBar Flowmeter, it is important to include all of the flowing conditions and pipe
information for your application. This will ensure that you receive the correct product for your application.
Please see the Mass ProBar Flowmeter Configuration Data Sheet 0080601004762.
Dimension Codes
Certain dimensions are critical to fabrication of the primary flow element assembly. The following codes can
be specified in the model callout string and Dieterich Standard, Inc. will build the primary flow element
assembly to suit. If no dimension is specified, cataloged components will default to standard dimensions.
ODH
ODV
ODV
ODH
NL
NL is the nipple length for DNW, DNF, and DNT-10
in-line models (Figure 36). Additional length can be
specified to fit specific piping configurations. The
extra length will be applied upstream of the sensor
unless otherwise specified.
ODF
ODF is the outside diameter of the pipe to the face of
the mounting flange (Figure 34). This dimension
applies only to DFF, DHF, DSF, NFF, SPF, SFF, and
SSF models. If Dieterich Standard, Inc. is not
supplying the mounting hardware, this dimension
must be specified. If Dieterich Standard, Inc. is
providing the mounting flange assembly, note
the following:
The standard ODF is a minimum.
The extensions must be at least 2 inches
longer than the minimum ODF.
CMH
CMH is the customer mount height distance from
the outside of the pipe to the top of the appropriately
sized NPT threaded female mounting coupling
(Figure 37). Supply these values for Regular and
FloTap models that are being installed in a
customers mounting or saddle.
ODF
CMH
Flow-136
Rosemount Inc.
Code
020
025
030
035
040
050
Code
Product Description
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok)
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok) with Opposite Side Support
Line Size
2 in. (50 mm)
2 in. (63.5 mm)
3 in. (80 mm)
3 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HA2S0
HA2SS
HP2S0
HP2SS
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2C0
CP2C0
SA2C0
SP2C0
Needle Valve - CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CA2S0
CA2SS
CP2S0
CP2SS
SA2S0
SP2S0
SP2SS
CB2C0
CC2C0
SB2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CB2S0
CB2SS
CC2S0
CC2SS
SB2S0
SC2S0
SV2S0
SV2SS
Code
MP2C0
MP2S0
MR2C0
MR2S0
Code
1
2
3
Code
3
4
C
D
Code
A
Mass ProBar
Model
Mounting Hardware
Pak-Lok, with Contoured Weld Fitting, 14 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 14 NPT, SST
Pak-Lok, No Contoured Weld Fitting, 14 NPT, CS
Pak-Lok, No Contoured Weld Fitting, 14 NPT, SST
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Flow-137
MODEL MBR+15S/16S
Code
1
2
Code
Mass ProBar
A
B
C
D
J
K
L
M
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
MS2C0
MS2CW
MS2S0
MS2SW
Code
Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT2C
MT2S
ME2C
ME2A
ME2K
ME2P
ME2S
NB20
NC20
ND20
NE20
NF20
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
Code
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
only)
only)
only)
only)
only)
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-138
Rosemount Inc.
MODEL MBR+25S/26S
MBR+25S
MBR+26S
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok)
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok) with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Mass ProBar
Model
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HATS0
HATSB
HATSD
HATSN
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HA2S0
HA2SS
HP2S0
HP2SS
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2C0
CP2C0
SA2C0
SP2C0
Needle Valves - CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CA2S0
CA2SS
CP2S0
CP2SS
SA2S0
SP2S0
SP2SS
Flow-139
MODEL MBR+25S/26S
Code
Mass ProBar
CB2C0
CC2C0
SB2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CB2S0
CB2SS
CC2S0
CC2SS
SB2S0
SC2S0
SV2S0
SV2SS
Code
MR4C0
MR4S0
MP4C0
MP4S0
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-140
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
Mounting Hardware
Pak-Lok, No Contoured Weld Fitting, 111.5 NPT, CS
Pak-Lok, No Contoured Weld Fitting, 111.5 NPT, SST
Pak-Lok, with Contoured Weld Fitting, 111.5 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 111.5 NPT, SST
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
MS4C0
MS4CW
MS4S0
MS4SW
Code
Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT4C
MT4S
ME4C
ME4A
ME4K
ME4P
ME4S
NE40
NF40
NG40
NH40
NJ40
Rosemount Inc.
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Mass ProBar
MODEL MBR+25S/26S
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-141
MODEL MBR+35S/36S
Model
MBR+35S
MBR+36S
Code
Mass ProBar
080
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Flow-142
Product Description
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok)
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok) with Opposite Side Support
Line Size
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HATS0
HATSB
HATSD
HATSN
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HA2S0
HA2SS
HP2S0
HP2SS
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2C0
CP2C0
SA2C0
SP2C0
Needle Valve - CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CA2S0
CA2SS
CP2S0
CP2SS
SA2S0
SP2S0
SP2SS
Rosemount Inc.
MODEL MBR+35S/36S
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
CB2C0
CC2C0
SB2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CB2S0
CB2SS
CC2S0
CC2SS
SB2S0
SC2S0
SV2S0
SV2SS
Code
MP6C0
MP6S0
MR6C0
MR6S0
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MS6C0
MS6CW
MS6S0
MS6SW
Mass ProBar
Code
Mounting Hardware
Pak-Lok, with Contoured Weld Fitting, 111.5 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 111.5 NPT, SST
Pak-Lok, No Contoured Weld Fitting, 111.5 NPT, CS
Pak-Lok, No Contoured Weld Fitting, 111.5 NPT, SST
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT6C
MT6S
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Flow-143
MODEL MBR+35S/36S
Code
Mass ProBar
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-144
Rosemount Inc.
MODEL MBR+45S/46S
MBR+45S
MBR+46S
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Descriptions
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok)
Mass ProBar Flowmeter - Regular (Threaded, Pak-Lok) with Opposite Side Support
Line Size
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Mass ProBar
Model
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HATS0
HATSB
HATSD
HATSN
HVDS0
HVDSN
HVMS0
HVPS0
HVDSB
HVTS0
HVTSB
HVTSD
HVTSN
HA2S0
HA2SS
HP2S0
HP2SS
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
CP2SS
SP2S0
SP2SS
Flow-145
MODEL MBR+45S/46S
Mass ProBar
Code
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
Code
MPDC0
MPDS0
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
Code
TRR
TXR
TRA
TRP
TXA
TXP
Code
3
5
6
7
8
Code
K
Flow-146
Mounting Hardware
Pak-Lok, with Contoured Weld Fitting, 38 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 38 NPT, SST
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion, Axial
Integral RTD, Explosion-Proof, Parallel
Rosemount Inc.
MODEL MBR+45S/46S
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K)
Special Calibration
Lab Flow Calibration (Average K)
Lab Flow Calibration (Average K)
Lab Flow Calibration (Average K)
Lab Flow Calibration (Average K)
Lab Flow Calibration (Average K)
Lab Flow Calibration (Average K)
(<10 in.)
Mass ProBar
Code
(12 in.)
(14 in. to 16 in.)
(18 in. to 20 in.)
(24 in.)
(30 in.)
(36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-147
Mass ProBar
Flow-148
Mass ProBar
Rosemount Inc.
Flow-149
Mass ProBar
Flow-150
Mass ProBar
Rosemount Inc.
Flow-151
Mass ProBar
Flow-152
Rosemount Inc.
Code
020
025
030
035
040
050
Code
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
2 in. (50 mm)
2 in. (63.5 mm)
3 in. (80 mm)
3 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Mass ProBar
Code
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HA2S0
HA2SS
HP2S0
HP2SS
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
CP2SS
SP2S0
SP2SS
CA2S0
SA2S0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
CB2S0
SB2S0
Flow-153
MODEL MBF+15S/16S
Code
Mass ProBar
FNMS0
FLMS0
FJMS0
FC4S0
FB4S0
FA4S0
Code
Flanged Mount
FA4C
FA4S
FB4C
FB4S
FC4C
FC4S
FJMC
FJMS
FLMC
FLMS
FNMC
FNMS
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MS2C0
MS2CW
MS2S0
MS2SW
Code
TRR
TXR
Code
3
5
6
7
8
Flow-154
Sensor Flange
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Plug, 14 NPT, CS
Plug, in. Socket Weld Ports, CS
Plug, 14 NPT, SST
Plug, in. Socket Weld Ports, SST
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Rosemount Inc.
MODEL MBF+15S/16S
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
Optional Meters
LCD Meter (Rate and Total)
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MBF+15S 020 HAMS0 CP2C0 FA4S0 FA4C 1 3 A 1 A 1 TXR B
Flow-155
Model MBF+25S/26S
Model
MBF+25S
MBF+26S
Code
Mass ProBar
040
050
060
080
100
120
140
160
180
200
240
300
360
Code
Flow-156
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
HATS0
HATSB
HATSD
HATSN
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2SS
CP2S0
CP2SS
SP2S0
SP2SS
CA2S0
SA2S0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Rosemount Inc.
Model MBF+25S/26S
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
CB2S0
SB2S0
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Code
Sensor Flange
FNPS0
FLPS0
FJPS0
FC6S0
FB6S0
FA6S0
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
FJPC
FJPS
FLPC
FLPS
FNPC
FNPS
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Mass ProBar
Code
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
MS4C0
MS4CW
MS4S0
MS4SW
Flow-157
Model MBF+25S/26S
Mass ProBar
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-158
Rosemount Inc.
MODEL MBF+25H/26H
MBF+25H
MBF+26H
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Mass ProBar
Model
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
HATH0
HATHB
HATHD
HATHN
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
HVTH0
HVTHB
HVTHD
HVTHN
HA2H0
HA2HS
HP2H0
PVH0
HV2H0
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
CA2H0
CP2H0
Flow-159
MODEL MBF+25H/26H
Code
Mass ProBar
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Code
Sensor Flange
FC6H0
FB6H0
FA6H0
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
Code
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-160
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
DP Ranges
02.5 to 0250 H2O (0.62 to 062.2 kPa)
010 to 0830 H2O (0-2.48 to 0206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
MS4C0
MS4CW
MS4S0
MS4SW
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Rosemount Inc.
MODEL MBF+25H/26H
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Meters
LCD Meter (Rate and Total)
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-161
MODEL MBF+25M/26M
Model
MBF+25M
MBF+26M
Code
Mass ProBar
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Flow-162
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADM0
HADMB
HADMN
HAMM0
HAPM0
HATM0
HATMB
HATMD
HATMN
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
HVTM0
HVTMB
HVTMD
HVTMN
HA2M0
HA2MS
HP2M0
HPVM0
HV2M0
HV2MS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
CP2M0
CA2M0
Rosemount Inc.
MODEL MBF+25M/26M
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Code
Sensor Flange
FC6M0
FB6M0
FA6M0
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
Code
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Mass ProBar
Code
DP Ranges
02.5 to 0250 H2O (0.62 to 062.2 kPa)
010 to 0830 H2O (02.48 to 0206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
MS4C0
MS4CW
MS4S0
MS4SW
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Flow-163
MODEL MBF+25M/26M
Code
Mass ProBar
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-164
Rosemount Inc.
MODEL MBF+35S/36S
MBF+35S
MBF+36S
Code
100
120
140
160
180
200
240
300
360
420
080
480
600
720
Code
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
8 in. (200 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Mass ProBar
Model
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
HATS0
HATSB
HATSD
HATSN
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
CP2SS
SP2S0
SP2SS
CA2S0
SA2S0
Flow-165
MODEL MBF+35S/36S
Code
Mass ProBar
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
CB2S0
SB2S0
Code
FNRS0
FLRS0
FJRS0
FC8S0
FB8S0
FA8S0
Sensor Flanges
DIN 50 PN 100, 316 SST
DIN 50 PN 40, 316 SST
DIN 50 PN 16, 316 SST
2 in. ANSI Class 600, RF, SST
2 in. ANSI Class 300, RF, SST
2 in. ANSI Class 150, RF, SST
Code
Flanged Mount
FA8C
FA8S
FB8C
FB8S
FC8C
FC8S
FJRC
FJRS
FLTC
FLTS
FNTC
FNTS
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-166
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Rosemount Inc.
MODEL MBF+35S/36S
MS6C0
MS6CW
MS6S0
MS6SW
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-167
MODEL MBF+45S/46S
Model
MBF+45S
MBF+46S
Code
Mass ProBar
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Flow-168
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
HATS0
HATSB
HATSD
HATSN
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HP2SS
HA2S0
HA2SS
HP2S0
HSHS0
HPVS0
HPVSS
HV2S0
HV2SS
HSVS0
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
SP2S0
CP2SS
SP2SS
Rosemount Inc.
MODEL MBF+45S/46S
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
Code
FNTS0
FLTS0
FJTS0
FCDS0
FBDS0
FADS0
Sensor Flanges
DIN 80 PN 100, 316 SST
DIN 80 PN 40, 316 SST
DIN 80 PN 16, 316 SST
3 in. ANSI Class 600, RF, SST
3 in. ANSI Class 300, RF, SST
3 in. ANSI Class 150, RF, SST
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
FJTC
FJTS
FLTC
FLTS
FNTC
FNTS
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
Mass ProBar
Code
DP Ranges
0.5 to 025 in H2O (0.12 to 06.22 kPa)
02.5 to 0250 H2O (0.62 to 062.2 kPa)
010 to 0830 H2O (02.48 to 0206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Flow-169
MODEL MBF+45S/46S
Mass ProBar
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-170
Rosemount Inc.
MODEL MBF+45H/46H
MBF+45H
MBF+46H
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Mass ProBar
Model
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
HATH0
HATHB
HATHD
HATHN
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
HVTH0
HVTHB
HVTHD
HVTHN
HA2H0
HA2HS
HP2H0
PVH0
HV2H0
HSVH0
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
SP2S0
CP2H0
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
Flow-171
MODEL MBF+45H/46H
Code
FCDH0
FBDH0
FADH0
Mass ProBar
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Flow-172
Sensor Flanges
Rosemount Inc.
MODEL MBF+45H/46H
M
Z
O
Q
S
U
W
Y
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Mass ProBar
Code
Flow-173
MODEL MBF+45M/46M
Model
MBF+45M
MBF+46M
Code
Mass ProBar
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Flow-174
Product Description
Mass ProBar Flowmeter - Flanged
Mass ProBar Flowmeter - Flanged with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
HADM0
HADMB
HADMN
HAMM0
HAPM0
HATM0
HATMB
HATMD
HATMN
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
HVTM0
HVTMB
HVTMD
HVTMN
HA2M0
HA2MS
HP2M0
HPVM0
HV2M0
HV2MS
HSVM0
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
SP2S0
CP2M0
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
Rosemount Inc.
Code
CC2S0
SC2S0
SV2S0
Code
Sensor Flanges
FCDM0
FBDM0
FADM0
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Mass ProBar
MODEL MBF+45M/46M
Flow-175
MODEL MBF+45M/46M
Code
Code
Mass ProBar
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-176
Mass ProBar
Rosemount Inc.
Flow-177
Mass ProBar
Flow-178
Mass ProBar
Rosemount Inc.
Flow-179
Mass ProBar
Flow-180
Mass ProBar
Rosemount Inc.
Flow-181
Mass ProBar
Code
005
007
010
012
015
020
Code
Line Size
in. (12.5 mm)
in. (19 mm)
1 in. (25 mm)
1 in. (31 mm)
1 in. (37.5 mm)
2 in. (50 mm)
Fittings
HAMS0
HADS0
HADSB
HADSN
HAPS0
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
HF1SS
HM1S0
Remote Mount
Fittings, in. Socket Weld Ports, SST
Fittings, 18 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, 18 NPT, CS
Needle Valve, Nipple and Tee, 18 NPT, CS
CP1S0
SP1S0
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, SST
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Flow-182
Product Description
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Rosemount Inc.
MODEL MNT+10S
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-183
Mass ProBar
Code
005
007
010
012
015
020
Code
Line Size
in. (12.5 mm)
in. (19 mm)
1 in. (25 mm)
1 in. (31 mm)
1 in. (37.5 mm)
2 in. (50 mm)
Fittings
HAMS0
HADS0
HADSB
HADSN
HAPS0
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
HF1SS
HM1S0
Remote Mount
Fittings, in. Socket Weld Ports, SST
Fittings, 18 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, 18 NPT, CS
Needle Valve, Nipple and Tee, 18 NPT, CS
CP1S0
SP1S0
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, SST
Code
Flanged Mount
FAS
FBS
FCS
FJS
FLS
FNS
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Flow-184
Product Description
DP Ranges
0.5 to 025 in H2O (0.12 to 06.22 kPa)
02.5 to 0250 H2O (0.62 to 062.2 kPa)
010 to 0830 H2O (02.48 to 0206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Rosemount Inc.
MODEL MNF+10S
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-185
MODEL MNF+10H
Model
MNF+10H
Code
Mass ProBar
005
007
010
012
015
020
Code
Line Size
in. (12.5 mm)
in. (19 mm)
1 in. (25 mm)
1 in. (31 mm)
1 in. (37.5 mm)
2 in. (50 mm)
Fittings
HADHN
HADH0
HADHB
HAMH0
HAPH0
HVDHN
HVDH0
HVDHB
HVMH0
HVPH0
HM1H0
Remote Mount
Fittings, 18 NPT, Hastelloy-C
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, 18 NPT, CS
Needle Valve, Nipple and Tee, 18 NPT, CS
CP1S0
SP1S0
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, SST
Code
Flanged Mount
FAH
FBH
FCH
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Flow-186
Product Description
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Rosemount Inc.
MODEL MNF+10H
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-187
MODEL MNF+10M
Model
MNF+10M
Code
Mass ProBar
005
007
010
012
015
020
Code
Line Size
in. (12.5 mm)
in. (19 mm)
1 in. (25 mm)
1 in. (31 mm)
1 in. (37.5 mm)
2 in. (50 mm)
Fittings
HADMN
HADM0
HADMB
HAMM0
HAPM0
HVDMN
HVDM0
HVDMB
HVMM0
HVPM0
HM1M0
Remote Mount
Fittings, 18 NPT, Monel
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, 18 NPT, CS
Needle Valve, Nipple and Tee, 18 NPT, CS
P1S0
SP1S0
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, SST
Code
Flanged Mount
FAM
FBM
FCM
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Flow-188
Product Description
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Rosemount Inc.
MODEL MNF+10M
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For use with remote mount head styles)
TRR
TXR
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-189
Mass ProBar
Code
005
007
010
012
015
020
Code
Line Size
in. (12.5 mm)
in. (19 mm)
1 in. (25 mm)
1 in. (31 mm)
1 in. (37.5 mm)
2 in. (50 mm)
Fittings
HAMS0
HADS0
HADSB
HADSN
HAPS0
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
HF1SS
HM1S0
Remote Mount
Fittings, in. Socket Weld Ports, SST
Fittings, 18 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, 18 NPT, CS
Needle Valve, Nipple and Tee, 18 NPT, CS
CP1S0
SP1S0
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 18 NPT, SST
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Flow-190
Product Description
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Rosemount Inc.
MODEL MNW+10S
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For use with remote mount head styles)
TRR
TXR
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Flow-191
Mass ProBar
Flow-192
Mass ProBar
Rosemount Inc.
Flow-193
Mass ProBar
Flow-194
Mass ProBar
Rosemount Inc.
Flow-195
Mass ProBar
Flow-196
Mass ProBar
Rosemount Inc.
Flow-197
Mass ProBar
Code
020
025
030
035
040
050
Code
Flow-198
Product Description
Mass ProBar Flowmeter - Threaded Flo-Tap
Line Size
2 in. (50 mm)
2 in. (63.5 mm)
3 in. (80 mm)
3 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HAMS0
HADS0
HADSB
HADSN
HAPS0
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
Rosemount Inc.
MODEL MHT+15S
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Code
GV3S0
GV3C0
GH3S0
GH3C0
Packing Gland
Graphite, 14 NPT, SST
Graphite, 14 NPT, CS
Urethane, 14 NPT, SST
Urethane, 14 NPT, CS
Code
Insert/Retract
IHRS
IHRC
Code
Isolation Valve
VT3SG
VT3CG
Gate Valve
Gate Valve, 14 NPT, SST
Gate Valve, 14 NPT, CS
VT3SB
VT3CB
Ball Valve
Ball Valve, 14 NPT, SST
Ball Valve, 14 NPT, CS
Code
Mounting Hardware
MH3C0
MH3S0
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Mass ProBar
Code
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
Flow-199
MODEL MHT+15S
Code
Mass ProBar
3
5
6
7
8
Code
K
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Code
Code
A
B
C
D
F
H
Code
M
Z
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHT+15S 030 HAMS0 C0000 GV3S0 IHRS VT3SG MH3C0 1 3 A 1 A TRR
Flow-200
Rosemount Inc.
MODEL MHT+25S
MHT+25S
Code
040
050
100
120
140
160
180
200
240
300
360
420
080
060
Code
Product Description
Mass ProBar Flowmeter - Threaded Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
8 in. (200 mm)
6 in. (150 mm)
Mass ProBar
Model
Head Style
HAMS0
HADS0
HADSB
HADSN
HAPS0
HATSN
HATS0
HATSD
HATSB
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
Flow-201
MODEL MHT+25S
Code
Mass ProBar
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Code
GV5S0
GV5C0
GH5S0
GH5C0
Packing Gland
Graphite, 111.5 NPT, SST
Graphite, 111.5 NPT, CS
Urethane, 111.5 NPT, SST
Urethane, 111.5 NPT, CS
Code
Insert/Retract
IHRS
IHRC
IHDS
Code
Isolation Valve
VT5SG
VT5CG
Gate Valve
Gate Valve, 111.5 NPT, SST
Gate Valve, 111.5 NPT, CS
VT5SB
VT5CB
Ball Valve
Ball Valve, 111.5 NPT, SST
Ball Valve, 111.5 NPT, CS
Code
Mounting Hardware
MH5C0
MH5S0
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-202
Instrument Connections (For use with Direct and Integral Mount Head Styles) (Continued)
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Rosemount Inc.
MODEL MHT+25S
TRR
TXR
TRA
TRP
TXA
TXP
Code
3
5
6
7
8
Code
K
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion, Axial
Integral RTD, Explosion-Proof, Parallel
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Code
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Mass ProBar
Code
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHT+25S 060 HATS0 C0000 GV5C0 IHRC VT5SG MH5C0 2 3 A 1 A B
Flow-203
MODEL MHT+35S
Model
MHT+35S
Code
Mass ProBar
100
120
140
160
180
200
240
300
360
420
080
480
600
720
Code
Flow-204
Product Description
Mass ProBar Flowmeter - Threaded Flo-Tap
Line Size
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
8 in. (200 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Head Style
HAMS0
HADS0
HADSB
HADSN
HAPS0
HATSN
HATS0
HATSD
HATSB
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Rosemount Inc.
MODEL MHT+35S
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Code
GV8S0
GV8C0
GH8S0
GH8C0
Packing Gland
Graphite, 211.5 NPT, SST
Graphite, 211.5 NPT, CS
Urethane, 211.5 NPT, SST
Urethane, 211.5 NPT, CS
Code
Insert/Retract
IHRS
IHRC
IHDS
Code
Isolation Valves
VT8SG
VT8CG
Gate Valve
Gate Valve, 211.5 NPT, SST
Gate Valve, 211.5 NPT, CS
VT8SB
VT8CB
Ball Valve
Ball Valve, 211.5 NPT, SST
Ball Valve, 211.5 NPT, CS
Code
Mounting Hardware
MH8C0
MH8S0
Code
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Mass ProBar
Code
DP Ranges
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 H2O (0-2.48 to 0-206 kPa)
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Flow-205
MODEL MHT+35S
Mass ProBar
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHT+35S 120 HATS0 C0000 GV8S0 IHRS VT8SG MH8S0 2 3 A 1 A 1 B
Flow-206
Mass ProBar
Rosemount Inc.
Flow-207
Mass ProBar
Flow-208
Mass ProBar
Rosemount Inc.
Flow-209
Mass ProBar
Flow-210
Mass ProBar
Rosemount Inc.
Flow-211
Mass ProBar
Flow-212
Rosemount Inc.
Code
020
025
030
035
040
050
Code
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
2 in. (50 mm)
2 in. (63.5 mm)
3 in. (80 mm)
3 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Code
GV4SC
GV4SB
GV4SA
GH4SC
GH4SB
GH4SA
Mass ProBar
Model
Packing Gland
Graphite, 1 in. ANSI Class 600, SST
Graphite, 1 in. ANSI Class 300, SST
Graphite, 1 in. ANSI Class 150, SST
Urethane, 1 in. ANSI Class 600, SST
Urethane, 1 in. ANSI Class 300, SST
Urethane, 1 in. ANSI Class 50, SST
Flow-213
MODEL MHF+15S
Code
Insert/Retract
IHRS
IHRC
Code
Isolation Valve
Mass ProBar
VC4SG
VC4CG
VB4SG
VB4CG
VA4SG
VA4CG
Gate Valve
Gate Valve,
Gate Valve,
Gate Valve,
Gate Valve,
Gate Valve,
Gate Valve,
VB4SB
VB4CB
VA4SB
VA4CB
Ball Valve
Ball Valve, 1 in.
Ball Valve, 1 in.
Ball Valve, 1 in.
Ball Valve, 1 in.
Flanged Mount
FA4C
FA4S
FB4C
FB4S
FC4C
FC4S
1 in. ANSI
1 in. ANSI
1 in. ANSI
1 in. ANSI
1 in. ANSI
1 in. ANSI
Code
DP Ranges
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
600, SST
600, CS
300, SST
300, CS
150, SST
150, CS
Code
1
2
3
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
Code
Optional Manifolds
3
5
6
7
8
Code
K
Flow-214
Rosemount Inc.
MODEL MHF+15S
Code
A
B
C
D
F
H
Code
M
Z
Optional Calibration
Lab Flow Calibration (Average K) (<10 in)
Special Calibration
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR017591
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Mass ProBar
Code
Typical Model Number MHF+15S 030 HAMS0 C0000 GV4SA IHRC VA4SG FA4S 1 3 A 1 A TRR
Flow-215
MODEL MHF+25S
Model
MHF+25S
Code
Mass ProBar
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Flow-216
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HATSN
HATS0
HATSB
HATSD
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
Rosemount Inc.
MODEL MHF+25S
Instrument Connections (Continued)
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Code
GV6SC
GV6SB
GV6SA
GH6SC
GH6SB
GH6SA
Packing Gland
Graphite, 1 in. ANSI Class 600, SST
Graphite, 1 in. ANSI Class 300, SST
Graphite, 1 in. ANSI Class 150, SST
Urethane, 1 in. ANSI Class 600, SST
Urethane, 1 in. ANSI Class 300, SST
Urethane, 1 in. ANSI Class 150, SST
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VC6SG
VC6CG
VB6SG
VB6CG
VA6SG
VA6CG
Gate Valve
Gate Valve, 1 in. ANSI
Gate Valve, 1 in. ANSI
Gate Valve, 1 in. ANSI
Gate Valve, 1 in. ANSI
Gate Valve, 1 in. ANSI
Gate Valve, 1 in. ANSI
VB6SB
VB6CB
VA6SB
VA6CB
Ball Valve
Ball Valve, 1 in. ANSI Class
Ball Valve, 1 in. ANSI Class
Ball Valve, 1 in. ANSI Class
Ball Valve, 1 in. ANSI Class
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Mass ProBar
Code
Class 600,
Class 600,
Class 300,
Class 300,
Class 150,
Class 150,
SST
CS
SST
CS
SST
CS
300, SST
300, CS
150, SST
150, CS
RF, CS
RF, SST
RF, CS
RF, SST
RF, CS
RF, SST
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Flow-217
MODEL MHF+25S
Code
Mass ProBar
A
B
C
D
J
K
L
M
Code
TRR
TXR
TRA
TRP
TXA
TXP
Code
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion, Axial
Integral RTD, Explosion-Proof, Parallel
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+25S 060 HATS0 C0000 GV6SA IHRC VA6CG FA6C 2 3 A 1 B
Flow-218
Rosemount Inc.
MODEL MHF+25H
MHF+25H
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Mass ProBar
Model
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
HATH0
HATHB
HATHD
HATHN
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
HVTH0
HVTHB
HVTHD
HVTHN
HA2H0
HA2HS
HP2H0
HPVH0
HV2H0
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
CA2H0
CP2H0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Flow-219
MODEL MHF+25H
Mass ProBar
Code
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Code
Packing Gland
GV6HC
GV6HB
GV6HA
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VC6SG
VC6CG
VB6SG
VB6CG
VA6SG
VA6CG
Gate Valve
Gate Valve, 1 in. ANSI Class 600, SST
Gate Valve, 1 in. ANSI Class 600, CS
Gate Valve, 1 in. ANSI Class 300, SST
Gate Valve, 1 in. ANSI Class 300, CS
Gate Valve, 1 in. ANSI Class 150, SST
Gate Valve, 1 in. ANSI Class 150, CS
VB6SB
VB6CB
VA6SB
VA6CB
Ball Valve
Ball Valve, 1 in. ANSI
Ball Valve, 1 in. ANSI
Ball Valve, 1 in. ANSI
Ball Valve, 1 in. ANSI
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-220
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Rosemount Inc.
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Mass ProBar
MODEL MHF+25H
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+25H 060 HATH0 C0000 GV6HA IHRC VA6CG FA6C 2 3 A 1 A
Flow-221
MODEL MHF+25M
Model
MHF+25M
Code
Mass ProBar
040
050
060
080
100
120
140
160
180
200
240
280
300
360
420
Code
Flow-222
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
4 in. (100mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
28 in. (711 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADM0
HADMB
HADMN
HAMM0
HAPM0
HATM0
HATMB
HATMD
HATMN
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
HVTM0
HVTMB
HVTMD
HVTMN
HA2M0
HA2MS
HP2M0
HPVM0
HV2M0
HV2MS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
CP2M0
CA2M0
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Rosemount Inc.
Code
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Code
GV6MC
GV6MB
GV6MA
Packing Gland
Graphite, 1 in. ANSI Class 600, Monel
Graphite, 1 in. ANSI Class 300, Monel
Graphite, 1 in. ANSI Class 150, Monel
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VC6SG
VC6CG
VB6SG
VB6CG
VA6SG
VA6CG
Gate Valve
Gate Valve, 1 in. ANSI Class 600, SST
Gate Valve, 1 in. ANSI Class 600, CS
Gate Valve, 1 in. ANSI Class 300, SST
Gate Valve, 1 in. ANSI Class 300, CS
Gate Valve, 1 in. ANSI Class 150, SST
Gate Valve, 1 in. ANSI Class 150, CS
VB6SB
VB6CB
VA6SB
VA6CB
Ball Valve
Ball Valve, 1 in. ANSI
Ball Valve, 1 in. ANSI
Ball Valve, 1 in. ANSI
Ball Valve, 1 in. ANSI
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Mass ProBar
MODEL MHF+25M
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Flow-223
MODEL MHF+25M
Mass ProBar
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+25M 060 HATM0 C0000 GV6MA IHRC VA6CG FA6C 2 3 A 1 A
Flow-224
Rosemount Inc.
MODEL MHF+35S
MHF+35S
Code
100
120
140
160
180
200
240
300
360
420
080
480
600
720
Code
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
8 in. (200 mm)
48 in. (1210 mm)
60 in. (1520 mm)
72 in. (1820 mm)
Mass ProBar
Model
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HATSN
HATS0
HATSD
HATSB
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
HVTSB
HVTSD
HVTSN
HP2SS
HA2S0
HA2SS
HP2S0
HPVS0
HPVSS
HV2S0
HV2SS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
Needle Valve, Elbow, 14 NPT, CS
Needle Valve, Elbow and Tee, 14 NPT, CS
CA2SS
CP2S0
SP2S0
CA2S0
SA2S0
CP2SS
SP2SS
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Flow-225
MODEL MHF+35S
Code
Mass ProBar
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
CB2SS
CC2SS
SV2SS
Code
GV8SC
GV8SB
GV8SA
GH8SC
GH8SB
GH8SA
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VB8SG
VB8CG
VA8SG
VA8CG
Gate Valve
Gate Valve, 2 in.
Gate Valve, 2 in.
Gate Valve, 2 in.
Gate Valve, 2 in.
VB8SB
VB8CB
VA8SB
VA8CB
Ball Valve
Ball Valve, 2
Ball Valve, 2
Ball Valve, 2
Ball Valve, 2
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FA8C
FA8S
FB8C
FB8S
FC8C
FC8S
Code
DP Ranges
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Packing Gland
Code
1
2
3
Flow-226
SST
CS
SST
CS
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Rosemount Inc.
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Mass ProBar
MODEL MHF+35S
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+35S 120 HATS0 C0000 GV8SA IHRC VA8CB FA8C 2 3 A 1 A
Flow-227
MODEL MHF+45S
Model
MHF+45S
Code
Mass ProBar
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
(1520 mm)
(1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
HATSN
HATS0
HATSD
HATSB
HVDSB
HVDSN
HVMS0
HVPS0
HVDS0
HVTS0
HVTSB
HVTSD
HVTSN
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
SP2S0
CP2SS
SP2SS
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
Code
GVDSC
GVDSB
GVDSA
Flow-228
Product Description
Packing Gland
Graphite, 3 in. ANSI Class 600
Graphite, 3 in. ANSI Class 300
Graphite, 3 in. ANSI Class 150
Rosemount Inc.
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VCDSG
VCDCG
VBDSG
VBDCG
VADCG
VADSG
Gate Valve
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
VBDSB
VBDCB
VADCB
VADSB
Ball Valve
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
Code
DP Ranges
1
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
SST
CS
SST
CS
CS
SST
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Code
Optional Manifolds
3
5
6
7
8
Mass ProBar
MODEL MHF+45S
Flow-229
MODEL MHF+45S
Code
K
Code
Mass ProBar
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+45S 240 HATS0 C0000 GV DSA IHRC VADCG FADC 2 3 A 1 A
Flow-230
Rosemount Inc.
MODEL MHF+45H
MHF+45H
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
(1520 mm)
(1820 mm)
Mass ProBar
Model
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
HATH0
HATHB
HATHD
HATHN
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
HVTH0
HVTHB
HVTHD
HVTHN
HA2H0
HA2HS
HP2H0
HPVH0
HV2H0
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
SP2S0
CP2H0
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
Flow-231
MODEL MHF+45H
Code
GVDHC
GVDHB
GVDHA
Mass ProBar
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VCDSG
VCDCG
VBDSG
VBDCG
VADCG
VADSG
Gate Valve
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
VBDSB
VBDCB
VADCB
VADSB
Ball Valve
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-232
Packing Gland
SST
CS
SST
CS
CS
SST
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Rosemount Inc.
MODEL MHF+45H
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Meters
LCD Meter (Rate and Total)
Mass ProBar
Code
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
CSA Explosion-Proof Approval
CSA Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+45H 240 HATH0 C0000 GVDHA IHRC VADCG FADC 3 A 1 A
Flow-233
MODEL MHF+45M
Model
MHF+45M
Code
Mass ProBar
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Flow-234
Product Description
Mass ProBar Flowmeter - Flanged Flo-Tap
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
(1520 mm)
(1820 mm)
Head Style
HADM0
HADMB
HADMN
HAMM0
HAPM0
HATM0
HATMB
HATMD
HATMN
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
HVTM0
HVTMB
HVTMD
HVTMN
HA2M0
HA2MS
HP2M0
HPVM0
HV2M0
HV2MS
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 14 NPT, CS
Needle Valve, Nipple and Tee, 14 NPT, CS
CP2S0
SP2S0
CP2M0
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 14 NPT, CS
CC2S0
SC2S0
SV2S0
Rosemount Inc.
MODEL MHF+45M
GVDMC
GVDMB
GVDMA
Packing Gland
Graphite, 3 in. ANSI Class 600, Monel
Graphite, 3 in. ANSI Class 300, Monel
Graphite, 3 in. ANSI Class 150, Monel
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Code
Isolation Valve
VCDSG
VCDCG
VBDSG
VBDCG
VADCG
VADSG
Gate Valve
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
VBDSB
VBDCB
VADCB
VADSB
Ball Valve
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
Code
DP Ranges
2
3
Code
3
4
C
D
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Mass ProBar
Code
SST
CS
SST
CS
CS
SST
Output
420 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G
316 SST 14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G
Code
Optional Temperature Sensors (For Use with Remote Mount Head Styles.)
TRR
TXR
TRA
TRP
TXA
TXP
Flow-235
MODEL MHF+45M
Code
Mass ProBar
3
5
6
7
8
Code
K
Code
1
Code
A
B
C
D
F
H
Code
M
Z
O
Q
S
U
W
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Meters
LCD Meter (Rate and Total)
Optional Calibration
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Lab Flow Calibration (Average K) (24 in.)
Lab Flow Calibration (Average K) (30 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number MHF+45M 240 HATM0 C0000 GVDMA IHDC VADCG FADC 2 3 A 1 A
Flow-236
Mass ProBar
Rosemount Inc.
Flow-237
Mass ProBar
Flow-238
Mass ProBar
Rosemount Inc.
Flow-239
Mass ProBar
Flow-240
Mass ProBar
Rosemount Inc.
Flow-241
Mass ProBar
Flow-242
Rosemount Inc.
FUNCTIONAL SPECIFICATIONS
Load Limitations
Service(1)
Pipe Sizes(2)
Load (Ohms)
420 mA dc
2000
Operating Region
0
11.0
35 42.4 V(1)
Power Supply Voltage V dc
(1) For CSA approval, power supply must not exceed 42.4 V dc.
Pressure Limits
0 to 1440 psig (100 barg) @ 100 F (37.8 C).
Contact the factory for higher pressures.
Temperature
Storage
-50 F to 230 F (-46 C to 110 C).
With Integral Meter
-40 F to 185 F (-40 C to 85 C).
Integral
Process
Integral mount
-40 F to 500 F (-40 C to 260 C).
55
Mass ProBar
Specifications
Output
Two wire 4-20 mA, user-selectable for DP, AP, PT, or
mass flow. Digital HART protocol super imposed on
420 mA signal, available to any host that conforms
to the HART protocol.
Power Supply
External power supply (or PS120/PS240 option)
required. Operates on 11-55VDC with no load.
(1) In most cases, the Mass ProBar flowmeter can measure different
fluids with different specific gravity values with no adjustments.
High Reynolds Numbers may cause some shifts in overall
accuracy; consult the factory.
(2) Consult factory for line size >72 in.
Flow-243
Damping
Process Temperature
Mass ProBar
Turn On Time
Humidity Limits
PERFORMANCE SPECIFICATIONS
Combined System Accuracy
10
2300
inch
4000
15/16
6500
25/26
10000
35/36
15000
Flow Turndown
45/46
25000
Where:
Differential Pressure
Ambient Temperature Effect Per 50 F (28 C)
+0.025% of URL + 0.175% of span, spans
from 1:1 to 30:1.
+0.035% of URL + 0.125% of span, spans
from 30:1 to 100:1.
Static Pressure Effects
Zero error = +0.10% of URL per 1000 psi
(6894 kPa).
Span error = +0.20% of reading per 1000 psi
(6894 kPa).
Stability
+0.1% of URL for 12 months.
Absolute/Gage Pressure
Ambient Temperature Effect Per 50 F (28 C)
+0.05% of URL+0.175% of span, spans from
1:1 to 30:1.
+0.06% of URL-0.125% of span, spans from
30:1 to 100:1.
Stability
+0.1% of URL for 12 months.
Flow-244
dV
Re rod = ----------
Rosemount Inc.
Electrical Considerations
1/214 NPT, PG 13.5, and CM20 conduit. HART
interface connections are permanently fixed
to the terminal block.
Sensor
316/316L SST.
HastelloyC (flanged models, sensors 10, 25/26, and 45/46).
Monel (flanged models, sensors 10, 25/26, and 45/46).
Electronics
SST Models
Vent valve and process: 316 SST.
Flanges: 316 SST.
Process isolating diaphragms: 316L SST.
Orings: Glass-filled TFE.
Mass ProBar
PHYSICAL SPECIFICATIONS
ORings
Packing Gland
316 SST.
Packing
Graphite AFP127.
Temperature Options
Integral RTD
100 Platinum RTD.
Remote
100 Platinum RTD.
Spring loaded with 14 NPT nipple and union.
KEMA/CENELEC
H Explosion Proof.
EEx d IIC T5 (Tamb = 70 C).
EEx d IIC T6 (Tamb = 40 C).
Enclosure Type: IP65.
F
Intrinsically safe.
EEx ia IIC T5 (Tamb = -45 to +40 C).
EEx ia IIC T4 (Tamb = -45 to +70 C).
Ui = 30V dc
Ii = 200 mA
Pi = 1.0 W
Ci = 0.012 F
Li = 0
Flow-245
Mass ProBar
May be protected by one or more of the following U.S. Patent Nos.4,559,836; 4,717,159, and various
foreign patents. Other foreign patents issued and pending.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
Coplanar, MV, and Multivariable are trademarks of Rosemount Inc.
PlantWeb is a mark of the Fisher-Rosemount group of companies.
Mass ProBar, ProBar, and Annubar are registered trademarks of Dieterich Standard Inc.
HART is a registered trademark of the HART Communications Foundation.
Monel is a registered trademark of International Nickel Co.
Teflon is a registered trademark of E. I. du Pont de Nemours & Co.
Hastelloy C and Hastelloy C-276 are registered trademarks of Cabot Corp.
Windows is a trademark of Microsoft Corp.
Cover Photo: 1295-001AB
Rosemount Inc.
Fisher-Rosemount Limited
Fisher-Rosemount
Heath Place
Bognor Regis
West Sussex PO22 9SH
England
Tel 44 (1243) 863 121
Fax 44 (1243) 867 5541
PR
INT
IN
U. S. A.
ED
00813-0100-4762+
00813-0100-4762 Rev. DA
Flow-246