Agilent 5100 ICP-OES


Synchronous Vertical Dual View (SVDV) with unique Dichroic Spectral
Combiner (DSC) technology

Agilent Confidential
September 9, 2014
3

Agilent 5100 ICP-OES


Dual View ICP-OES minus the wait
Why waste time and money running your sample on a dual
view ICP instrument, which has to take 2, 3 or even 4
sequential measurements. Get accurate results on your
toughest samples in a single, simultaneous measurement,
using the Agilent 5100 SVDV with unique DSC technology
5100 SVDV has differentiated technology that delivers
the speed and performance you have been waiting for
Agilent Confidential
September 9, 2014
4

How Do Traditional Dual View Instruments Work?

To detector
M

Mirror M is
movable and
provides radial
viewing (not
simultaneous)

Agilent Confidential
September 9, 2014
5

What is Synchronous Vertical Dual View with unique


Dichroic Spectral Combiner technology (DSC)

Axial light from plasma

Radial light
from plasma

Dichroic
Spectral
Combiner
To detector

September 9, 2014
6

5100 SVDV model working in axial only (DV)


Mirror is moved into position for axial view only

Axial light reflected


into poly

Mirror
To detector
Radial light
reflected away
September 9, 2014
7

5100 SVDV model working in radial only (DV)


Hole is moved into the plasma light path for radial only

Axial light goes straight


through hole to photon
stop

Hole

To detector
Radial light
into poly

September 9, 2014
8

Agilent 5100 ICP-OES Project Drivers


Reduce operating costs and increase reliability
Enhance Agilent ICP-OES Performance Advantage
Improve Usability

Agilent Confidential
September 9, 2014
9

Reminder of technology and industrial design


Smallest
footprint of
major ICPOES
vendors

Unique Synchronous
Vertical Dual View (SVDV)

Robust solid state RF


Smart electronics

1 orientation Vertical
Torch
Easy access to
spraychamber/nebulizer
improving usability

Corrosion
resistant sample
compartment

Easy access to
power, gas,
cooling water and
comms from RHS
Pump position close
to samples reduces
sampling times
improves throughput

Easy access to
Easy-Fit torch
Agilent Confidential
September 9, 2014
10

Behind the covers

April 30, 2013


Agilent Confidential
Page 11

Optimized footprint through strategic Industrial Design


Small footprint

Agilent Confidential
September 9, 2014
12

Footprint Comparison
Model

Width
(mm)

Depth
(mm)

Footprint
(m2)

Height
(mm)

Weight
(kg)

Agilent 5100 (Aurora)

800

740

0.59

825

100

Agilent 700 Series

1300

750

0.98

990

203

Thermo 7000 Series

840

750

0.63

590

N/L

PE Optima 8300

1320

800

1.06

760

193

40% smaller than 700 series, 7% smaller than iCAP 7000

Agilent Confidential
September 9, 2014
13

Key Agilent 5100 SVDV ICP-OES benefits


Lowest cost
of ownership

Fastest sample
throughput of difficult
samples
Low gas consumption

Enhanced
Performance

Analytical performance
System robustness and
reliability

Simple
Operation

Hardware
Software

Agilent Confidential
September 9, 2014
14

1. Lowest cost of ownership


Speed = low gas costs per sample
Synchronous VDV measures axially and radially at the same time
Thermostatically stabilized optics with Vista Chip2 CCD

Reduces repeat analysis requirements

Measures wavelengths simultaneously

Hermetically sealed detector for fast warm up and low gas consumption

Low exhaust extraction (2.5m3/min, >50% lower than 700 series))


- Reduces lab air conditioning requirements saving money
Lower power consumption 2.9KVA (>40% lower than 700 series)
- Lowers power bills

Agilent Confidential
September 9, 2014
15

1. Lowest cost of ownership


Reduced maintenance costs
SSRF generation

No RF power tube to replace

There are less parts and less labour for any repairs that have to be effected

Vertical Easy-fit torch

5 x longer torch life (compared to 720 torch) through vertical orientation and
strategic design

Customer maintainable

Pre optic windows and gas filter

Agilent Confidential
September 9, 2014
16

2. Enhanced Performance
Analytical performance
Analytical Performance
Elimination of EIE interference with sensitivity of axial instrument.
Long Term Stability with complex matrix

Agilent Confidential
September 9, 2014
17

2. Enhanced Performance
System Robustness
System Robustness
Improved corrosion resistance from

positive pressure design


polymer components in sample traffic area
Conformal coating of all circuit boards and SSRF
Aluminium chasis (not steel like 700)

Mains power supply and RF power supply

Located out of high volume air flow


Vertically mounted to allow dust to fall through

Enhanced diagnostics and Smart electronics

Reduce service times

Agilent Confidential
September 9, 2014
18

3. Simple Operation

Easy Fit SVDV torch


Easy fit Sample Introduction System
Customer Installable Gas control module
Customer replaceable pre optic window and CCI
Customer replaceable gas filter

Agilent Confidential
September 9, 2014
19

3. Simple Operation
Intuitive workflow ICP Expert V7 software
No need to pick axial or radial like conventional DV. In SVDV mode,
DSC does this automatically
PC controlled Make Up gas port
Customer replaceable dust filter
MFC on all plasma/sample gas lines

Agilent Confidential
September 9, 2014
20

Performance proof EIE Immunity


5ppm K Readback
40.0

35.0

30.0

[K] ppm

25.0

Radial

20.0

Axial

SVDV

15.0

10.0

5.0

0.0
1

10

100
[Na] ppm

1000

10000

September 9, 2014
22

Performance proof EIE immunity


5ppm K Readback
40.0

35.0

30.0

[K] ppm

25.0
Radial

20.0

Axial
SVDV

15.0

Axial+1%CsCl

10.0

5.0

0.0
1

10

100
[Na] ppm

1000

10000

September 9, 2014
23

5ppm multielement LTS.


SVDV with vertical DV torch, 1.8mm injector.
19 hrs. <1%RSD.
1.2

0.8

0.6

As 188.980

Se 196.026

Zn 202.548

Zn 213.857

Cd 214.439

Pb 220.353

Ni 231.604

Mn 257.610

Cr 267.716

Cu 324.754

Cu 327.395

Al 396.152

Sr 407.771

Ba 455.403

Ba 493.408

K 766.491

LL

UL

0.4

0.2

0
12:00:00 AM

2:24:00 AM

4:48:00 AM

7:12:00 AM

9:36:00 AM

12:00:00 PM

2:24:00 PM

4:48:00 PM

7:12:00 PM

September 9, 2014
24

Performance Proof 4 hr LTS on 25% NaCl with 1ppm std.


<1.3% RSD. Axial results from VDV configuration
120%

% Readback

100%
80%
60%
40%
20%
0%
0:00:00

0:30:00
Al 167.019
Co 238.892
Ni 231.604
Sr 407.771

1:00:00

1:30:00
Al 396.152
Cr 267.716
Pb 182.143
Zn 213.857

2:00:00
Time (h:mm:ss)
As 188.980
Cu 327.395
Pb 220.353
+10% Readback

2:30:00

3:00:00

Ba 455.403
Mn 257.610
Se 185.457
-10% Readback

3:30:00

4:00:00

Cd 214.439
Mo 202.032
Se 196.026

OneNeb, Double pass glass cyclonic, Blk/Blk & Blu/Blu, AHA, demountable torch
1.8mm injector, 15rpm. (Also tried on 2.4mm injector with same results)
September 9, 2014
25

Performance Proof Interim Axial IDL (n=1


instrument)
VDV configuration.. IDLs similar to 720
VDV Axial IDL
Element nm

VDV Axial IDL

720 Axial IDL


Element nm

720 Axial IDL

Mg 279.553

ug/L
0.01

ug/L
0.01

0.1

Mn 257.610

0.03

0.03

1.79

Mo 202.032

0.37

0.5

Au 242.794

0.62

Na 589.592

0.12

0.15

B 249.772

0.2

0.1

Ni 231.604

0.6

0.3

Ba 455.403

0.02

0.03

P 177.434

1.74

1.5

Be 313.042

0.01

0.01

Pb 220.353

1.39

0.8

Bi 223.061

1.75

S 181.972

3.9

Ca 396.847

0.02

0.01

Sb 206.834

2.29

Cd 214.439

0.12

0.05

Se 196.026

2.48

Ce 418.659

0.67

Si 251.611

0.63

Co 238.892

0.38

0.2

Sn 189.925

1.56

Cr 267.716

0.2

0.15

Sr 407.771

0.004

0.01

Cu 327.395

0.12

0.3

Ti 334.941

0.05

0.1

Fe 238.204

0.17

0.1

Tl 190.794

1.76

1.5

Hg 184.887

0.79

0.8

V 292.401

0.25

0.2

K 766.491

0.28

0.3

Zn 213.857

0.11

0.2

Li 670.783

0.01

0.06

Zr 343.823

0.12

0.3

Ag 328.068

ug/L
0.16

ug/L
0.3

Al 167.019

0.14

As 188.980

Single pass S/C, Seaspray neb, semi demountable VDV torch 1.8mm injector, equivalent to 3x30 sec read
time, 15rpm, blk/blk PVC pump tubes, each element and has optimized power and neb flow.
Agilent Confidential
September 9, 2014
26

Gas Use Ar/min


As per USEPA 200.7 App Note and site prep docs
5100
SVDV

Optima
8300DV

iCAP
7600

Normal + Boost
Optics purge
Detector purge

3.7
0

7
1

4
0.08

14*
0.4

Plasma flow
(coolant)
Aux flow
Neb flow
Snout
CCI/shear
total (L/min)

12
1
0.7
0
3
20.4

8
0.2
0.55

13
0.5
0.65

18
0.5
0.7

13
0.8
0.7

16.75

18.23

33.6

14.5

L/min

Spectroblue
Prodigy
EOP

Ar/min
40
35

NOTE:
8300 can use N2 for Optics and
this reduces flow to 5L/min
Boost purge chosen for all
vendors as US EPA monitors
Arsenic
SVDV mode doesnt need snout
flow for radial.
Nitrogen will additionally be
needed on the 8300 for shear
gas for US EPA 200.7 at 1823L/min.
If air is used for the 8300 shear
gas, may need a refrigerated
drier in humid environment.

30
25
20

15
10
5
0
5100 SVDV

Optima 8300DV

iCAP 7600

Prodigy

Spectroblue
EOP

Agilent Confidential
September 9, 2014
27

Gas Use Ar/sample


As per US EPA 200.7 app notes

USEPA 200.7
(min)
Ar L/sample
Valve/No Valve

5100
SVDV

Optima
8300DV

iCAP
7600

1.16
23.664

2.36
39.53

2.36
43.0228

valve

Valve

Valve

Prodigy
5
168
No
Valve

Spectroblue
EOP
2.5
36.25
No Valve

Ar/sample
180
160
140
120
100
80
60

40
20
0
5100 SVDV

Optima
8300DV

iCAP 7600

Prodigy 7

Spectroblue
EOP

Agilent Confidential
September 9, 2014
28

Resolution Performance Proof


PP1

PP2

Agilent Confidential
September 9, 2014
29

Accuracy Performance proof


Oyster Tissue Synthetic Reference Material
Al 396.152
As 188.980
Cd 214.439
Ca 373.690
Cr 205.560
Co 228.615
Cu 324.754
Fe 259.940
Pb 220.353
Mg 279.078
Mn 257.610
Ni 231.604
P 213.618
K 769.897
Se 196.026
Si 250.690
Na 589.592
S 181.972
Zn 206.200

Target
mg/L
3
0.1
0.03
15
0.007
0.004
0.6
2
0.005
12
0.2
0.01
80
100
0.02
10
50
70
9

Axial
mg/L
3
0.1
0.03
15
0.007
0.005
0.6
2
0.004
12
0.2
0.01
79
101
0.02
9
37
70
9

%
recovery
100
100
100
100
100
125
100
100
80
100
100
100
99
101
100
90
74
100
100

Al 396.152
As 188.980
Cd 214.439
Ca 373.690
Cr 205.560
Co 228.615
Cu 324.754
Fe 259.940
Pb 220.353
Mg 279.078
Mn 257.610
Ni 231.604
P 213.618
K 769.897
Se 196.026
Si 250.690
Na 589.592
S 181.972
Zn 206.200

Target
mg/L
3
0.1
0.03
15
0.007
0.004
0.6
2
0.005
12
0.2
0.01
80
100
0.02
10
50
70
9

LP6 SVDV
%
recovery
mg/L
3
100
0.1
100
0.03
100
16
107
0.007
100
0.003
75
0.6
100
2
100
0.008
160
12
100
0.2
100
0.01
100
80
100
93
93
0.02
100
9
90
49
98
71
101
9
100

It Just Works
Agilent Restricted
June 2, 2011
30

Agilent 5100 ICP-OES market segments

Environmental

Food & Agriculture

Materials Science

Chemical & Energy

Pharmaceuticals

Drinking and natural water

Trace toxic metals in food

Mining and Metals

Petroleum refining

Heavy metals
(USP<232>/<233>)

Soil and sediment

Nutrient elements

Toys and Consumer Products

Alternative Energy (Biodiesel)

Incoming raw material testing

Waste (solids/liquids/gases)

Feed and fertilizer

Semicon, Ceramics, Batteries

Fine and Bulk Chemicals

QA/QC of Final Product

Agilent Confidential
September 9, 2014
31

Why is SVDV perfect for Environmental and Food and


Agriculture segments
Performance required when measuring trace level toxic
elements and higher level nutrient elements
Speed/low gas costs (SVDV, Vista Chip2)
EIE immunity (SVDV)
LDR (Vista Chip2)
Resolution/interference minimization (Echelle optics,
FACT/IEC, Fitted Background Correction)
Usability (Software, Easy Fit Torch)

Agilent Confidential
September 9, 2014
32

Why is 5100 perfect for Materials and Chemical and


Energy segments
Performance characteristics when measuring mining samples
or organic samples
Highly stable plasma system (SSRF)
Matrix tolerance and robust sample intro (Vertical torch, HF
resistant SIS)
Long term stability (MFC, Thermostatted optics)

Agilent Confidential
September 9, 2014
33

Why is 5100 perfect for Pharmaceutical market


segment?
Sensitivity (USP232)
21CFR11
IQOQ classic protocol

Agilent Confidential
September 9, 2014
34

Agilent 5100 ICP-OES portfolio


3 different configurations

SVDV*

Synchronous
Vertical Dual View

VDV

Vertical Dual View

RV

Radial View

*Agilent 5100 Synchronous Vertical Dual View with unique Dichroic


Spectral Combiner technology
Agilent Confidential
September 9, 2014
35

Model Range
Feature
Vertically orientated plasma with dual viewing capability
Vertically orientated plasma with Synchronous Dual View

5100 VDV

5100 SVDV

O*

5100 RV

Vertically orientated with radial viewing only plasma


Robust, solid-state 27MHz RF generator

5 channel peristaltic pump

Second generation VistaChip2 CCD

Mass flow controlled nebulizer

PC controlled make-up gas for high salt solutions or hydride generator

Computer controlled oxygen accessory for organic solvents

Easy-fit torch

167 to 785 nm wavelength range

ICP Expert 7 base software

ICP Expert 7 Pro Feature Pack software

Hydride generator accessory

SVS2+ productivity accessory

Standard capacity autosampler support in software

Extended capacity autosampler support in software

21 CFR 11 compliance

Nitrogen Purge for Polychromator

April 30, 2013


Agilent Confidential
Page 36

QUIZ:
What are the Key Aurora benefits?
Lowest cost
of ownership

Fastest sample
throughput of difficult
samples
Low gas consumption

Enhanced
Performance

Analytical performance
System robustness and
reliability

Simple
Operation

Hardware
Software

Agilent Confidential
September 9, 2014
37

NEW ICP Expert V7 software


Common software platform with MP-AES
MP Expert

ICP Expert

Acclaimed simplicity
Intuitive workflow
Applet mode to further simplify start up
No need to pick which wavelength uses the different view on SVDV
mode
June
2, 2011
Agilent
Restricted
38

NEW ICP Expert V7 software Method Development


MP Expert

ICP Expert

June
2, 2011
Agilent
Restricted
39

NEW ICP Expert V7 Analysis page spectrum view

June
2, 2011
Agilent
Restricted
40

NEW ICP Expert V7 Analysis Page IEC view

June
2, 2011
Agilent
Restricted
41

New ICP Expert V7 Analysis Page - Nebulizer Argon


Back pressure and Ar emission

September 9, 2014
42

Service Diagnostics Gasbox monitoring

September 9, 2014
43

Service Diagnostics Camera Control

September 9, 2014
44

SUMMARY
Agilent 5100 ICP-OES Synchronous Vertical Dual View

1. Lowest Cost of Ownership


2. Enhanced Performance
3. Easy Operation

Agilent Confidential
September 9, 2014
45

Agilent 5100 ICPOES


Technology Review

Agilent Confidential
September 9, 2014
46

What patents have been granted and what are


pending?
1. Hosemans SSRF supply. Patent granted in US, China, Japan. Pending in
Europe, Australia and Canada.
2. Dichroic Spectral Combiner technology (DSC) Patent pending in US, China
and Great Britain
3. Invention disclosures submitted for work coil connection.
Carried through from 700 series:
4. Vista Chip patent
5. FACT
6. Injector taper of the High TDS torch

September 9, 2014
47

Whats not New?


1.
2.
3.
4.

Polychromator
Camera board
Peri Pump
Peri pump
CNTL board
5. PWB
6. Gas box from
TAD
7. Fan from
MPAES
8. Flue from
MPAES
9. Igniter from MP
10. Water inlet filter
from MS

1.

8.

5.

4.

3.

2.
9.

6.

7.

10.

September 9, 2014
48

Whats new:
SVDV with unique DSC technology
NOTE:
1. SVDV has assembly with dichroic
and mirror

Dichroic
Hole

2. VDV has assembly that has 2


mirrors (for balance)
3. RV does not have this assembly

Mirror

4. Early DL studies showed that the


background signal was lower on UV
lines. This is due to the DSC
filtering out stray light from red
spectrum.
September 9, 2014
49

What analysis modes can SVDV give?


1. Synchronous VDV
2. Vertical Dual View
3. Axial only

4. Radial only

4 modes in one instrument.

September 9, 2014
50

Whats new: Torch loader and pre-optics..1


Excellent registration with Torch mount
ADVANTAGE: no plasma scanning needed to optimize plasma
emission into optics.
Automatic rotating wheel to house DSC technology.
ADVANTAGE: Simplify method development for SVDV analysis

Plasma and Aux gas


lines come through
torch mount

Whats New: Torch loader and pre-optics..2

Active thermal stabilizer developed to isolate polychromator from RF


box heat. The peltier device in the thermal stabilizer does not require
additional water cooling and is not user adjustable. It sits at 35C.
ADVANTAGE: No Heat transfer from pre optics. Thermally
stability ensures LTS.
Customer replaceable CaF2 pre optic windows for radial and axial
orientation
ADVANTAGE: Reduced maintenance costs

Whats New: Sample Intro and Vertical Torch

Ground glass joint between s/c and torch


One Piece (Bonded) and semi demountable torches. (Quartz and
ceramic).
Ignites through torch (doesnt need consumeable copper strip)
Plasma can run dry, plasma sits centrally.

April 30, 2013


Agilent Confidential
Page 53

RF load coil
700 series
soft and readily damaged by customers inserting torches.
Generalist FSEs often over tighten the Swagelok fitting and distort
brand new load coils

Agilent 5100 ICP-OES


hardened copper coated in gold
Torch loader prevents customers damaging coils during loading
Collette fitting to prevent over tightening
Agilent Confidential
September 9, 2014
54

Torch Range

Part Number

Description

G8010-60231

5100 HF Dual View Torch

G8010-60232

5100 High Salt Dual View Torch

G8010-60233

5100 Semi Volatile DV Torch

G8010-60234

5100 HF Radial Torch

G8010-60235

5100 Volatile Organic Rad Torch

G8010-60236

5100 Demountable DV Torch

G8010-60237

5100 Demountable Radial Torch

G8010-60238

5100 Dual View Torch

G8012-60000

5100 Radial Torch


Agilent Confidential
September 9, 2014
55

Optics
All wavelengths captured in one reading
- Maximum speed and productivity
Fewer optical components
- Deliver high light throughput
- Excellent signal-to-noise
- Excellent detection limits

Thermostatted to 35oC
- Excellent long term stability
- Fast start-up, increasing sample throughput

Agilent Confidential
September 9, 2014
56

Vista Chip 2 CCD

>98% wavelength coverage 167 785 nm


Use alternate wavelengths to extend Linear
dynamic range and also to confirm results

1 MHz processing speed

True simultaneous measurement

Duplex readout circuitry halves readout time

Peltier cooled to -40oC


Ensures low noise and best detection limits

Agilent Confidential
September 9, 2014
57

Long term Stability


19 hrs. <1%RSD.
1.2

0.8

0.6

As 188.980

Se 196.026

Zn 202.548

Zn 213.857

Cd 214.439

Pb 220.353

Ni 231.604

Mn 257.610

Cr 267.716

Cu 324.754

Cu 327.395

Al 396.152

Sr 407.771

Ba 455.403

Ba 493.408

K 766.491

LL

UL

0.4

0.2

0
12:00:00 AM

2:24:00 AM

4:48:00 AM

7:12:00 AM

9:36:00 AM

12:00:00 PM

2:24:00 PM

4:48:00 PM

7:12:00 PM

September 9, 2014
58

Long term Stability - SSRF Generator

MgI/MgII ratio >10 @ 1kW (corrected


for Polychromator)
Efficiency of:
Oscillator: @75% above 1.2kW
Power range adjustment of 700W to
1500W in 50W increments

Tested with100% methanol &


Kerosene,
98 RON PULP (petrol), 25% NaCl for
>1 Hr.
Cycled between 5% methanol, 5%
NaCl, 1% Nitric acid for 3 hours.

New power control circuitry.

April 30, 2013


Agilent Confidential
Page 59

Long Term Stability - Gas Box and Gas Control

Used the ICPMS gas box and adapted it for


5100.

Pressure sensor on nebulizer line enables neb


pressure to be monitored on analysis page

All plasma gas lines have MFC and are PC


controlled. (EPC from 7900 gasbox)

Plasma gas 0-20L/min @ 0.5L/min

Nebulizer gas 0-1.5L/min @ 0.01L/min

Auxiliary gas 0-2L/min @ 0.1L/min

Make Up gas 0-2L/min @ 0.01L/min

Polychromator has MFC on it also that was


designed in MGV SPSD.

Gas Control Module enables swap over to


modify gas usage. (1, 2 and 3 port varieties
available)

2 port gas plate shown. Default


installation on SVDV and RV
Agilent Confidential
September 9, 2014
60

Mains power supply and RF power supply


Mains supply is mounted
vertically and replaces
transformer technology in
the 700 series.
Located away from blower. It
is in positive pressure
environment and at lower
voltage will attract less dust.
Has conformally coated
boards to resist dust and
acid vapor attack.
RF supply half size of mains
supply so easy to
ship/replace. Distributes
100V DC to RF oscillator.
Replaces the HVDC PS from
700 series.
Agilent Confidential
September 9, 2014
61

Polychromator gas flow


MFC control of gas flow through the poly (Agilent designed)

Poly flow is used to purge the pre optics. (0.7 + 3 L/min)


Snout and CCI are separate flows to the poly
Snout and CCI are not MFC controlled

L/min

5100
SVDV

Normal + Boost
Optics purge
Detector purge

3.7
0

Plasma flow
(coolant)
Aux flow
Neb flow
Snout
CCI/shear
total (L/min)

12
1
0.7
0
3
20.4

Service engineers will have access to a super


purge (adds 6L/min into poly)

Typical plasma flow

Can have the snout gas at 0. Otherwise will be 1.4L/min when on.

Agilent Confidential
September 9, 2014
62

Accessories
2 and 3 port gas control plates (separate options for VDV)
5 channel peri pump (option for VDV)
SPS3
Cetac ASX520

VGA77P
MSIS
SVS1+ and SVS2+
Isomist TBD.August 1st CPL?

September 9, 2014
63

Gas control module


VDV ships with single port gas control module
SVDV/RV 2&3 port gas control module included.

Ar= supply for plasma and optics


Option Gas= Ar/Ox mix automatically routed through Aux line for Organics (80/20 blend)
N2= Separate purge for poly
Agilent Confidential
September 9, 2014
64

Additional Dust protection


Optional filter that provides a higher level of protection for components inside
the instrument than the coarse dust filter in 700 series
Customer installable.

Agilent Confidential
September 9, 2014
66

External Inlet Adapter


Additional protection from corrosive vapor and dust, fresh air
from external to the laboratory can be ducted into the
instrument.
External Inlet Adapter can enable ducting to be connected to
the fresh air intake of the 5100.

Agilent Confidential
September 9, 2014
67

SVS 1+/2+
SVS1+

SVS2+

Small actuator

Small actuator

ICP Expert V7 has built in


software control

Higher quality USB to QUAD


serial converter

No manual control of valve


from actuator

7 port valve assembly

Higher quality connections

Simplified assembly and


operation
Note:
Prototype
controller

September 9, 2014
68

Additional Sample Introduction kits


HF resistant sample introduction kit (Glyn/Phil show and tell)
Volatile Organics sample introduction kit
Semi volatile organics kit

NOTE: Isomist is planned to be included onto the CPL as a


chilled spray chamber.
Target is August 1st.

Agilent Confidential
September 9, 2014
69

Software ICP Expert V7


Based on MP Expert
Win 7 64 Bit
Flat file data storage (apart from CFR and this has database administered through
Software Database Administrator with SQL Server 2008)
Supported in:
Japanese
Simplified Chinese
English
French
German
Italian
Spanish
Portuguese

Russian
CFR: English only at release.
Agilent Confidential
September 9, 2014
70

What has been added into ICP Expert V7

Real-time correction of background, l trim, calibration fit etc.


Dynamically change sample labels, number of samples during run
Monitor nebulizer back pressure and Ar intensity during run
Fast Ethernet communications

Eliminates PCI GPIB cable and card

Access from any computer via network

Many additional pages for service diagnostics

Intelligent error messages.


Hooks for Remote Advisor
21CFR11 software SCM/SDA capability like 700 series
Agilent Confidential
September 9, 2014
71

Consumables
Update for the
5100 ICP-OES
Know more,
sell better

Sell better, sell


more

Consumables for 5100 ICP-OES


PS/AE Training May 2014

Key Agilent 5100 SVDV ICP-OES benefits


Lowest cost
of ownership

Reduced maintenance
costs
Fastest sample
throughput
Low gas consumption

Enhanced
Performance

Analytical
performance
System robustness
and reliability

Simple
Operation

New sample
introduction system
Instrument hardware
design
Software

Consumables for 5100 ICP-OES


PS/AE Training May 2014
73

5100 ICP-OES Reduced Maintenance


Easy Fit Vertical torch
- 5 x longer torch life (compared to 720 torch) through vertical
orientation and strategic design
Customer replaceable components
- Pre optics window and CCI
- Argon gas filter

Consumables for 5100 ICP-OES


PS/AE Training May 2014
74

5100 ICP-OES Enhanced Performance

Easy Fit Vertical torch


- Improved long term stability
- Improved performance with high TDS samples (due to vertical
orientation)

Easy fit Sample Introduction System


- Reduced memory effects
- Faster washout
- Improved productivity

Consumables for 5100 ICP-OES


PS/AE Training May 2014
76

5100 ICP-OES Simple Operation

Easy Fit Vertical torch


Easy fit Sample Introduction System
Customer Installable Gas control module
Customer replaceable pre optic window and CCI
Customer replaceable gas filter

Consumables for 5100 ICP-OES


PS/AE Training May 2014
77

Enhancements with 5100 Sample Intro


U-series SeaSpray nebulizer
with Unifit sample connector
Helix nebulizer connection on
spray chamber
Unifit spray chamber drain
connector
Easyfit torch design

Consumables for 5100 ICP-OES


PS/AE Training May 2014
78

Limitations of the SeaSpray neb. with EzyFit


Many users do not seat the
EzyFit connector correctly
Small dead space between
EzyFit and nebulizer
capillary

Traps small volume of sample


Can introduce memory effects
Increases washout times slightly
Decreases sample throughput

Consumables for 5100 ICP-OES


PS/AE Training May 2014
79

Advantages of the U-Series nebulizer


Same connector (U-Series nebulizer &
UniFit connector) used with the 7900
ICP-MS
Sample connector fits directly over the
outside of the sample inlet

Eliminates any dead space between


sample connector and neb. capillary

Uniform sample channel from sample entry


to nebulizer tip reduces blockage
Reduced memory effects no trapped
sample
Faster washout
Improved productivity
Improves ease of use

Unifit connector seals directly against the


sample inlet arm

Consumables for 5100 ICP-OES


PS/AE Training May 2014
80

Advantages of the Helix spray chamber


Eliminates the O-ring seal used on nebulizer inlet

Eliminates dead volume in the nebulizer seal


No O-Rings to replace
Inert impervious to organic solvents and strong acids
Special release/lock mechanism seals the chamber
Positive stop to ensure correct nebulizer position

Consumables for 5100 ICP-OES


PS/AE Training May 2014
81

Advantages of the Unifit drain connector


PTFE connector fits directly over
the outside of the waste outlet
Improves ease of use
Remains easy to fit and remove
Doesnt bond/stick to the glass

Faster washout

Improved productivity

Consumables for 5100 ICP-OES


PS/AE Training May 2014
82

5100 Easyfit Torch

Vertical torch -

True radial analysis (25% TDS) with torch robustness


benefits from having vertical radial torch
Axial view sensitivity
Automatic torch alignment - no torch scanning required
Automatic gas connection to eliminate confusion around gas
line fitting
Longer torch lifetime

Consumables for 5100 ICP-OES


PS/AE Training May 2014
83

Torch configurations for 5100 SVDV*/VDV ICP-OES


5 different configurations
All SVDV torches have slot for radial viewing

One piece

Permanently bonded
1.8mm ID injector

Demountable

Same as one piece torch


Torch components replaceable

Organics
demountable

Narrow 1.4mm ID injector


Torch components replaceable

High Solids
demountable

Wide 2.4mm ID injector


Torch components replaceable

Ceramic fully
demountable

Quartz outer & ceramic 1.8mm


ID injector (straight)
Torch components replaceable

*Synchronous Vertical Dual View


(features unique Dichroic Spectral Combiner)
Consumables for 5100 ICP-OES
PS/AE Training May 2014
84

Torch configurations for 5100 RV* ICP-OES


3 different configurations
All RV torches have shorter outer tube for radial viewing (no slot required)

One piece

Permanently bonded
1.4mm ID injector

Demountable

Same as one piece torch


Torch components
replaceable

Volatile
organics
demountable

Small 0.8mm ID injector


Torch components
replaceable

*Radial View
(Note: Can be used with SVDV for improved radial performance)
Consumables for 5100 ICP-OES
PS/AE Training May 2014
85

Some Consumables Shared with 700 Series ICP


Description

Part Number

Peristaltic pump tubing


- for sample uptake (white/white)
- for waste (blue/blue)
- for internal standard (orange/white or smaller)

3710034400
3710034600
3710046900

Y piece connector for int. standard

1610132400

Gas inlet connector (Ezylok) for nebulizer

9910127800

Clamp for ball joint

G8000-64140

Inlet cooling air filter

G8000-68002

Wavelength calibration solution


Concentrate (dilute 10x prior to use)
Ready to use solution

6610030000
6610030100

Consumables for 5100 ICP-OES


PS/AE Training May 2014
86

Consumables Unique to the 5100 ICP-OES


Description

Part Number

SeaSpray nebulizer
(features U-series sample inlet)
Sample tubing for nebulizer (0.75mm ID)
Sample tubing for nebulizer (0.5mm ID)

G8010-60255

Twister double pass spray chamber

G8010-60256

UniFit connector for spray chamber waste

TBC

Inert double pass spray chamber

G8010-68007

Torches for SVDV/VDV Instruments

TBC
G3266-80012

Part Number

Easy-fit VDV torch (one piece)

G8010-60228

Demountable version of the Easy-fit VDV


torch

G8010-60236

Organics version of the Easy-fit VDV torch


(1.4mm ID inj.; demountable)

G8010-60233

High solids version of the Easy-fit VDV


torch (2.4mm ID inj.; demountable)

G8010-60232

HF version of the Easy-fit VDV torch


(1.8mm ID inj., ceramic outer + injector;
demountable)

G8010-60231

Torches for Radial Instruments

Part Number

Easy-fit RV torch (one piece)

G8012-60000

Demountable version of the Easy-fit RV


torch

G8010-60237

Volatile organics version of the Easy-fit


VDV torch (0.8mm ID inj.; demountable)

G8010-60235

Consumables for 5100 ICP-OES


PS/AE Training May 2014
87

What Consumables to Sell with 5100 ICP-OES?


Always offer one of the ICPOES Consumables Kits with the
5100
Each kit contains all the essential and
common supplies required for routine
operation of the 5100 ICP-OES
- For SVDV/VDV models, use part #
G8010-67001 (TBC)
- For radial RV models, use part #
G8012-67001 (TBC)

Components in the Operating Supplies Kit


(Preliminary contents may change)

2 one piece torches


4 packs pump tubing (for sample + waste)
1 pack int. standard pump tubing & connectors
SeaSpray nebulizer (U series)
1 pack of Unifit connectors for nebulizer
1 pack of Ezylok gas connectors for nebulizer
Twister spray chamber with Helix fitting
1 pack of Unifit connectors for spray chamber drain

Customers can re-order regularly to


ensure they have all the essential
supplies on hand
- Minimizes downtime
- Reduces operating costs through
discounted pricing

Spare clamp for the ball joint


Spare pre-optic window
(radial kit incl. an extra window for the radial view)

Spare washer for the window assembly


Drain tubing
Consumables for 5100 ICP-OES
PS/AE Training May 2014

88

Das könnte Ihnen auch gefallen