Modular Design
Ten different, individually fused door control
modules are available for virtually any
application. Time delays, latching relays and
multiple station circuit breaker modules are
available for custom configuration in the field
or at the factory.
MADE IN
THE USA
TM
Features
Class 2 Outputs
Where permitted by code, conduit is not
required when using Class 2 outputs.
Large Heavy Gauge Enclosure
Model 631RFA is housed in a 16 gauge,
16"W x 14"H x 6.5"D cabinet large
enough to accommodate several
additional modules and six 7 Amp hour
batteries with plenty of room for wiring.
sdcsecurity.com
service@sdcsecurity.com
Price & Installation
Ordering Information
631RFL
631RF
631RFA
Options
PC
KL
14-2
PS-1
PS-1A
230V
631RFL
1.5 Amp Power Supply
Less Box
How to Order
Electrical Specifications
Input:
115VAC @ 800mA, 50/60 Hz, Fused
(220/230VAC 50/60 Hz optional, not UL Listed)
Selectable Secondary Output:
12VDC or 24VDC @ 1.5 Amp,
poly fuse protected, Class 2
Mechanical Specifications
RB12V4
RB12V7
631RF:
631RF
631RFA
5Ah
10Ah
20Ah
5 Ah Battery Qty
5Ah
10Ah
RB12V4
RB12V7
FB4
0.25
19.6
49
124
12VR
0.50
7.8
20
49
0.50
7.8
20
PSM
1.00
3.1
11.3
19.4
1.00
3.1
11.3
UR-1,
UR-2A, UR-4A
NA
NA
1.50
1.8
4.5
11.3
1.50
1.8
4.5
CR-4
ACM-1
8Ah
16Ah
24Ah
4
1
3-6
0-2
0-2
5 Ah Battery Qty
Battery Qty.
PB-8, PB-16
3-4
Amp Hours
Load/Amps
8 Ah Battery Qty
Amp Hours
Load/Amps
Amp Hours
Load/Amps
0.25
8Ah
16Ah
32Ah
48Ah
8 Ah Battery Qty
Amp Hours
Load/Amps
19.6
49
0.25
36.7
92
232
400
0.25
36.7
0.50
14.5
36
92
157
0.50
1.00
5.7
14.4
36
62
1.00
1.50
3.3
8.4
21
36
1.50
92
158
14.5
36
62.7
5.7
14.4
24.8
3.3
8.4
14.4
Fused Outputs
FB-4
Remote Monitoring
12VR
PSM
TM
UR2-4 Specifications
Conventional Relay
Latching Relay (pulse on, pulse off)
Latch individual station or all stations
Time Delay Relay 1-35 seconds
*Dual - Latching & Time Delay Relay
Mantrap - All doors normally locked
Interlock - All doors normally unlocked
*Primary input triggers the Time Delay
Auxiliary input triggers latch function
The relay mode may be different per
individual station. When mantrap or interlock
mode is selected, all outputs operate the same.
UR4-8 Specifications
Input Voltage: 12 or 24VDC +/- 10%
Input Current: 350mA, at rest
430mA, operating
Trigger Inputs: N.O. Dry
Optically Isolated
(2) Inputs per output, (8) Total plus
(4) Auxiliary inputs
Outputs:
4 Fused SPDT Dry, 5 Amp @ 30VDC
4 Non-fused, SPDT Dry,1 Amp @ 30VDC
Dimensions: 7L x 5W x 1.75H
(177.8 x 127 x 44.5mm)
sdcsecurity.com service@sdcsecurity.com
PB-8
CR4
ACM-1
PB-16
14-2
Distance
Table 4: Lock & Strike Wire Gauge Chart
(AWG)in feet for 2 conductors from
power source to the locking device.
Distance in feet for 2 conductors from power source to the locking device.
AMPS
25ft
50
75
100
150
200
250
300
400
500
750
1000
0.15
20
20
20
20
20
20
20
20
20
20
18
16
0.25
20
20
20
20
20
20
20
20
18
16
16
14
0.50
20
20
20
20
18
18
18
16
16
14
14
0.75
20
20
20
18
18
16
16
14
1.00
20
20
18
18
16
16
14
14
1.50
20
18
18
16
14
14
Wire Gauge
www.sdcsecurity.com service@sdcsecurity.com
[t] 800.413.8783 805.494.0622