Sie sind auf Seite 1von 8

Product Data Sheet

00813-0100-4001, Rev DB
September 2003

Rosemount 3051
Dimensional Drawings
3051 Exploded View

Certification Label
Span and Zero
Adjustments(1)
(Standard)
Electronics Housing

Terminal Block
Cover O-ring
Cover
Electronics Board

Nameplate
Sensor Module
Housing Rotation Set Screw
(180 Maximum Housing Rotation
without Further Disassembly)

Coplanar Flange

Drain/Vent Valve

Process O-Ring

Flange Adapter O-Ring


Flange Alignment Screw
(Not Pressure Retaining)

Flange Adapters

NOTE
Dimensions are in inches (millimeters).

1) Span and Zero Adjustments are not available with fieldbus or profibus protocols.

16

3031B08A

Flange Bolts

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051
3051C Coplanar Flange Dimensional Drawing
(Differential Pressure Transmitter Shown)

5.0 (127)
4.3 (110)
0.75 (20) Clearance
for Cover Removal

0.75 (20) Clearance


for Cover Removal

1
/214 NPT
Conduit Connection
(Two Places, Other
Sizes Available)

4.1
(105)

Terminal
Connections

Transmitter
Circuitry

7.1
(181) 8.2
(209)

Nameplate
Drain/Vent Valve

Certification
Label

Coplanar Flange
Process Connection
Per DIN STD. 19213
2.13 (54) 0.008 in.
Connection Centers

6.4
(163)
1/214 NPT on Optional Flange Adapters. Adapters can be rotated
to give connection centers of 2.00 (51), 2.125 (54), or 2.25 (57).

3051-3031A06A, B06A

Housing Rotation
Set Screw

18 NPT on Coplanar Flange


for Pressure Connection without the Use of
Flange Adapters
NOTE
Dimensions are in inches (millimeters).

Coplanar Flange Mounting Configurations with


Optional Bracket (B4) for 2-in. Pipe or Panel Mounting
2.8
(72)

4.3
(110)

PANEL MOUNTING

2.8 (71)
7.1
(181)

5
/16 1 Bolts
for Panel Mounting
(Not Supplied)

3/816

1 Bolts
for Mounting
to Transmitter

6.2
(156)

2.8
(71)

1.1 (28)
3.4 (85)

4.8
(120)

6.0
(152)

3.3
(83)

3051-3031A04H,I04A,M04A,L04A,J04A

PIPE MOUNTING

2-inch U-Bolt
for Pipe Mounting

17

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051

Traditional Flange Mounting Configurations with


Optional Brackets for 2-in. Pipe or Panel Mounting
OPTION B2/B8:
TRADITIONAL FLANGE
PANEL MOUNTING
BRACKET

10.1
(257)

OPTION B1/B7/BA:
TRADITIONAL
FLANGE 2-IN. PIPE
MOUNTING
BRACKET

2.7
(67)

4.2
(106)

Impulse Piping

1.1 (28)
3.8
(95)

5/16

x 7/8 Bolts for Panel


Mounting (Not Supplied)

2.7
(67)

6.2
(158)
2.81
(71)
PANEL MOUNTING
BRACKET

1.4
(33)

PIPE MOUNTING
BRACKET

4.6
(116)

NOTE
Dimensions are in inches (millimeters).

3051-3031J19D, I19C, E19C, C19A

9.6
(243)

Traditional Flange (Options H2H7) Dimensional Drawing


5.0
(127)

1/214 NPT
Conduit
Connection
(Two Places
Other Sizes
Available)

4.3
(110)
0.75 (20)
Clearance for
Cover Removal

Certification Label
4.1
(105)

Housing
Rotation
Set Screw

Transmitter
Circuitry

Terminal
Connections

Nameplate
1
/418 NPT on
Traditional Flange for
Pressure Connection
Without the Use of
Flange Adapters.
Connection Per DIN
STD. 19213 2.13 (54)
0.008 in.
Connection Centers

NOTE
Dimensions are in inches (millimeters).

18

1.7 (43)

2.2
(56)

Drain/
Vent
Valve
1.1
(28)

3.4
(87)

1.1
(28)

1
/214 NPT on
Optional Flange
Adapters.
Adaptors Can Be
Rotated to Give
Connection
Centers of 2.00
(51), 2.125 (54),
or 2.25 (57).

3051-3031E30A, D30B

7.9
(202)

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051
3051T Dimensional Drawings
1/214

NPT
Conduit
Connection (Two
Places, Other
Sizes Available)

5.0
(127)
4.3
(110)

Certification
Label
4.1
(105)

0.75 (20)
Clearance
for Cover
Removal

0.75 (20)
Clearance for
Cover Removal

Transmitter
Circuitry

Terminal
Connections

7.2
(183)

Nameplate

3051-3051TC6A, TB6A

Housing
Rotation
Set Screw

NOTE
Dimensions are in inches (millimeters).

3051T Typical Mounting Configurations with Optional Mounting Bracket


PIPE MOUNTING

PANEL MOUNTING
2.9
(72)

4.3
(110)

5.1
(130)

6.2
(156)
2.8 (71)
3.5
(90)
NOTE
Dimensions are in inches (millimeters).

6.3
(160)

4.8
(120)
6.9
(175)

3051-3051TA4A, TB4A, TC4A

2
(50)

19

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051

3051H Pressure Transmitter Exploded View and Dimensional Drawings


Secondary
Filled System

Sensor Module

High Side
Process Flange

3051-3051HB2G

Process Isolating
Diaphragm
Low Side
Process Flange
Drain/Vent Valve
Flange Bolts
1/214 NPT
Conduit Connection
(Two Places, Other
Sizes Available)

5.0
(127)
4.3
(110)

4.1
(105)

Certification
Label

0.75 (19)
Clearance for
Cover Removal

0.75 (19) Clearance


for Cover Removal

Transmitter
Circuitry

Terminal
Connections

Nameplate

9.0
(228)

Housing Rotation
Set Screw

10.8
(275)

1.2
(30)
NOTE
Dimensions are in
inches (millimeters).

20

1/218

NPT on Process Flange for


Pressure Connection Without the
Use of Mounting Adapters

3.4
(86)

1.1
(28)

1
/214 NPT on Optional Mounting
Adapters. Adapters Can Be Rotated
to Give Adapter Connection Centers of
2.00 (51), 2.1256 (54), or 2.25 (57).

3051-3051i01A, H01B

Drain/Vent
Valve

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051

3051H Mounting Brackets for 2-in. Pipe and Panel Mount (Option Code B5/B6)

PIPE MOUNTING CONFIGURATION

Impulse Piping

2.7
(67)

0.7 (16)
4.4
(109)

2.7
(67)

NOTE
Dimensions are in inches (millimeters).

3051-3031G19A, F19B, 3051HB3A, HA3B

7
/16203/4 Bolts Supplied for
Attaching Bracket to Transmitter

PANEL MOUNTING CONFIGURATION

Impulse Piping

21

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051
3051L Dimensional Drawings

3- AND 4-IN. FLANGE CONFIGURATION

2-IN. FLANGE CONFIGURATION

(FLUSH MOUNT ONLY)

Certification Label

4.1
(105)

Certification Label

4.1
(105)

Serrated Face
Gasket Surface

1
(25)

Housing
Rotation
Set
Screw

E F
E

Lower Housing

Gasket

1/214

1/214

NPT
Mounting
Adapter
(optional)

A
Extension
2, 4, or 6 (51, 102, or 152)

1
/214 NPT Conduit
Connections (optional)

OPTIONAL FLUSHING
CONNECTION RING
(LOWER HOUSING)
1 (25)

NPT
Mounting
Adapter
(optional)

6.5
(165)

5.0
(127)
4.3
(110)

Transmitter Circuitry
0.75 (19) Clearance for
Cover Removal

Terminal Connections
0.75 (19) Clearance for
Cover Removal

5.14
(131)

Flushing Connection

7.1
(181)
8.2
(209)

Nameplate

DIAPHRAGM ASSEMBLY
AND MOUNTING FLANGE

/418 NPT on Flange for Pressure


Connection without the Use of
Mounting Adapters

NOTE
Dimensions are in inches (millimeters).

22

Drain/Vent
Valve

3051-3031B27A, 27B, 27C, 3031B27D, C27E

Product Data Sheet


00813-0100-4001, Rev DB
September 2003

Rosemount 3051

TABLE 9. 3051L Dimensional Specifications


Except where indicated, dimensions are in inches (millimeters).
Bolt Circle
Diameter

Outside
Diameter

No. of
Bolts

Bolt Hole
Diameter

Exten.
Diam.(1)
D

O.D. Gask.
Surf.
E

Proc. Side
F

Class

Pipe Size

Flange
Thickness

ASME B 16.5
(ANSI) 150

2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
DN 50

1.12 (28)
1.31 (33)
1.31 (33)
1.25 (32)
1.50 (38)
1.62 (41)
1.12 (28)
1.37 (35)
26 mm

4.75 (121)
6.0 (152)
7.5 (191)
5.0 (127)
6.62 (168)
7.88 (200)
5.0 (127)
6.62 (168)
125 mm

6.0 (152)
7.5 (191)
9.0 (229)
6.5 (165)
8.25 (210)
10.0 (254)
6.5 (165)
6.62 (168)
165 mm

4
4
8
8
8
8
8
8
4

0.75 (19)
0.75 (19)
0.75 (19)
0.75 (19)
0.88 (22)
0.88 (22)
0.75 (19)
0.88 (22)
18 mm

NA
2.58 (66)
3.5 (89)
NA
2.58 (66)
3.5 (89)
NA
2.58 (66)
NA

3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
4.0 (102)

2.12 (54)
3.5 (89)
4.5 (114)
2.12 (54)
3.5 (89)
4.5 (114)
2.12 (54)
3.5 (89)
2.5 (63)

DN 80
DN 100
DN 100

30 mm
30 mm
26 mm

160 mm
190 mm
180 mm

200 mm
235 mm
220 mm

8
8
8

18 mm
22 mm
18 mm

65 mm
89 mm
89 mm

5.4 (138)
6.2 (158)
6.2 (158)

3.7 (94)
4.5 (114)
4.5 (114)

ASME B 16.5
(ANSI) 300
ASME B 16.5
(ANSI) 600
DIN
PN 1040
DIN PN 25/40
DIN PN 10/16

(1) Tolerances are 0.040 (1,02), 0.020 (0,51)

23

Das könnte Ihnen auch gefallen