SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

0098.1214.MIBO
18 Desember 2014

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

To :
Mr.Teguh Dwi Widodo
Jurusan Teknik Mesin - Fakultas Teknik
Universitas Brawijaya
Jln. MT Haryono 167 Malang 65145
Telp
:
Fax.
:
Thank you for your inquiry dated:

16-Dec-2014

We have the pleasure to offer the following:-

DESCRIPTION

NO. QTY
1

Autolab PGSTAT101 - Entry Level


The smallest member in the Autolab range of electrochemical
instruments

including :
- dummy cell and a built-in analog interior
- NOVA Software
- transport case
Key features:
Electrode connections
Potential range
Compliance voltage
Maximum current
Current ranges
Potential accuracy
Potential resolution
Current accuracy
Current resolution
Input impedance
Potentiostat bandwidth
Computer interface
Control software

PRICE

ART. NUMBER

2, 3 and 4
+/- 10 V
+/- 10 V
+/- 100 mA
10 mA to 10 nA
+/- 0.2 %
3 V
+/- 0.2 %
0.0003 % (of current range)
> 100 GOhm
1 MHz
USB
NOVA

Page 1 of 7

AUT101.v

IDR

92,000,000

Indonesia PT

SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

INSTRUMENT DESCRIPTION

NO. QTY

0098.1214.MIBO
18 Desember 2014

Autolab PGSTAT204 - Compact and modular


potentiostat/galvanostat
The instrument includes a base potentiostat/galvanostat with a
compliance voltage of 20 V and a maximum current of 400 mA.
The potentiostat can be expanded at any time with one
additional module, for example the FRA32M electrochemical
impedance spectroscopy (EIS) module.

including :
- dummy cell and a built-in analog interior
- NOVA Software
Compatible
modules
FRA32M
EQCM
BA
pX1000
MUX

Key features
Electrode connections
Potential range
Compliance voltage
Maximum current
Current ranges
Potential accuracy
Potential resolution
Current accuracy

2, 3 and 4
+/- 10 V
+/- 20 V
+/- 400 mA
100 mA to 10 nA
+/- 0.2 %
3 V
+/- 0.2 %

Current resolution

0.0003 % (of current


range)

Input impedance
Potentiostat bandwidth
Computer interface
Control software

> 100 GOhm


1 MHz
USB
NOVA

PRICE

ART. NUMBER

Page 2 of 7

AUT204

IDR

125,500,000

Indonesia PT

SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

NO. QTY
3

0098.1214.MIBO
18 Desember 2014

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

INSTRUMENT DESCRIPTION
Autolab PGSTAT128N - Entry Level Modularity

PRICE

ART. NUMBER
AUT128N

IDR

247,500,000

AUT302N

IDR

274,500,000

The entry level member of the modular Autolab instruments family,


low current, low noise and fast potentiostat/galvanostat capable of
measuring maximum 800 mA, with a compliance voltage of 12 V
including :
- differential electrometer amplifier, dummy cell and monitor cable
- NOVA Software
Key features
Compatible
modules
Electrode connections
EQCM
2, 3 and 4
Potential range
FRA32M
+/- 10 V
Compliance voltage
BA
+/- 12 V
BOOSTER
+/- 800 mA (10 A
10A
Maximum current
with BOOSTER10A)
1 A to 10 nA (100 pA
with ECD module)
Current ranges
ECD
+/- 0.2 %
Potential accuracy
SCAN250
Potential resolution
ADC10M
0.3 V
Current accuracy
MUX
+/- 0.2 %
0.0003 % (of current
range)
Current resolution
FI20
Input impedance
pX1000
> 1 TOhm
Potentiostat bandwidth
ECN
500 kHz
Computer interface
USB
Control software
NOVA
4

Autolab PGSTAT302N - High Performance


The high end, high current potentiostat/galvanostat, with a
compliance voltage of 30 V and a bandwidth of 1 MHz
including :
- differential electrometer amplifier, dummy cell and monitor cable
- NOVA Software
Compatible
Key features
modules
Electrode connections
2, 3 and 4
EQCM
Potential range
+/- 10 V
FRA32M
Compliance voltage
+/- 30 V
BA
+/- 2 A (20 A
BOOSTER
Maximum current
with BOOSTER20A)
20A/10A
1 A to 10 nA (100 pA
with ECD module)
Current ranges
ECD
+/- 0.2 %
Potential accuracy
SCAN250
0.3 V
Potential resolution
ADC10M
+/- 0.2 %
Current accuracy
MUX
0.0003 % (of current
range)
Current resolution
FI20
Input impedance
> 1 TOhm
pX1000
Potentiostat bandwidth
1 MHz
ECN
Computer interface
USB
Control software
NOVA
Page 3 of 7

Indonesia PT

SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

ART. NUMBER

Autolab PGSTAT100N - High Voltage Applications


The high voltage potentiostat/galvanostat with a compliance
voltage of 100 V and a maximum current of 250 mA
including :
- differential electrometer amplifier, dummy cell and monitor cable
- NOVA Software
Compatible
Key features
modules

AUT100N

Electrode connections
Potential range
Compliance voltage
Maximum current
Current ranges
Potential accuracy
Potential resolution
Current accuracy
Current resolution
Input impedance
Potentiostat bandwidth
Computer interface
Control software

NO. QTY
1

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

INSTRUMENT DESCRIPTION

NO. QTY

0098.1214.MIBO
18 Desember 2014

2, 3 and 4
+/- 10 V
+/- 100 V
+/- 250 mA (10 A
with BOOSTER10A)
100 mA to 10 nA (100
pA with ECD module)
+/- 0.2 %
0.3 V
+/- 0.2 %
0.0003 % (of current
range)
>
100 GOhm
400 kHz
USB
NOVA

PRICE
IDR

327,200,000

FRA32M
FI20
BA
BOOSTER
10A
ECD
SCAN250
ADC10M

MODULE DESCRIPTION

PRICE

ART. NUMBER

FRA32M Module - Impedance analysis


Electrochemical impedance spectroscopy (EIS) for the analysis of
impedance data
pX1000
Module to measure pH or pX in parallel with an electrochemical
measurement
EQCM
The EQCM Module provides the means to perform
Electrochemical Quartz Crystal Microbalance experiments

FRA32M

IDR

115,000,000

pX1000

IDR

42,562,963

EQCM

IDR

145,822,222

BA

IDR

50,370,370

BA-Dual Mode Bipotentiostat Module


Converts the Autolab into a double channel potentiostat.
Measurements on 2 working electrodes can be performed sharing
the same counter and reference electrode.

Page 4 of 7

Indonesia PT

SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

ACCESSORIES DESCRIPTION

NO. QTY

0098.1214.MIBO
18 Desember 2014

PRICE

ART. NUMBER
Corr.Cell

IDR

72,281,481

Flat Cell

FlatCell

IDR

32,715,556

Faraday Cage

FarCage

IDR

12,340,741

Aksesoris, consists of :

IDR

22,756,195

Support rod-mount for 649/728

6.2026.010

Pt-Auxilliary Electrode WOC

6.0301.100

Ag/AgCl reference electrode with ceramic diaphragm

6.0733.100

Support rod-mount for 649/728

1
1
1

Titr. Vessel Lid SGJ


Bottom of Titr. Vessel 10mL
Bottom of Titr. Vessel 50mL

6.2026.010
6.1414.010
6.1415.210
6.1415.250

Corrosion Cell 400 mL

3
4

Offers are subject to confirmation


WARRANTY

: 1 (one) Year Franco Jakarta, excluding accessories and spare parts

PT. METROHM INDONESIA

Bertha Oktarina
Bertha Oktarina
Metrohm Sales Manager

Page 5 of 7

Indonesia PT

SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

0098.1214.MIBO
18 Desember 2014

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

MODULE & ACCESSORIES - TECHNICAL SPECIFICATIONS


FRA32M Module - Impedance analysis
- Frequency range :
- Frequency resolution :
- Input range :
- Signal types :
- Input channels :
- AC amplitude :

- Data presentation :
- Data analysis :

10 Hz - 32 MHz
0.00003
+/- 10 V
1 sine, 5 sine, 15 sine
E and i from the potentiostat/galvanostat or X and Y external signals
0.2 mV to 0.35 V rms in potentiostatic mode
2 mV to 3.5 V rms (optional)
0.0002 - 0.35 times current range in galvanostatic mode
Nyquist, Bode, Admittance, Dielectric, Mott-Schottky
Fit and Simulation, Find circle, Element subtraction

BA-Dual Mode Bipotentiostat Module


- Number of channels :
1 (5 for Multi BA)
- Potential range :
+/- 10 V
- Current ranges
10 mA to 10 nA, in 7 decades
- Current accuracy
+/- 0.2%
- Current resolution
0.0003% (of current range)
- Maximum current
+/- 50 mA
- Modes
Bipotentiostat and scanning bipotentiostat
pX1000
- Input range :
- Measurement resolution :
- Measurement accuracy :
- Input impedance :
- Tempearture accuracy :
- Temperature resolution :

+/- 10V
30 mV
+/- 2 mV
> 1 Yohm // 8 pF
+/- 0.50C
0.0150C

EQCM
- Oscillation frequency :
- Resolution :
- Relative accuracy :
- Sampling rate :
- Frequency range :

6 MHz
0.07 Hz
1 Hz
50 S/s
80.000 Hz

Corrosion Cell 400 mL


It can be connected to a waterbath and come with sample holder, reference electrode, 2 counter electrodes, thermometer and
gas inlet. The reference electrode is positioned close to the sample by using a Luggin capillary.
Flat Cell
The Flat cell has been designed to measure the corrosion properties of circular samples immersed in an electrolyte.
Faraday Cage
- external dimensions :
- internal dimensions :

(W x D x H) 38 x 21 x 38 cm3
(W x D x H) 34 x 19 x 34 cm3

Page 6 of 7

Indonesia PT

SALES QUOTATION

PT. Metrohm Indonesia

Quotation No. :
Date
:

Menara Batavia 3rd Floor


Jl. K.H. Mas Mansyur Kav. 126
Jakarta 10220 I N D O N E S I A
Tel: +62 21 5727318
Fax: +62 21 5727274
E-mail : metrindo@metrohm.co.id
www.metrohm.com

0098.1214.MIBO
18 Desember 2014

Terms and Condition


Franco
: Malang
Validity
: 30 days
Terms
: 100% Advanced Payment
Delivery
: 8-12 weeks after PO
Currency
: IDR (Indonesia Rupiah)

MODULE & ACCESSORIES - TECHNICAL SPECIFICATIONS


Ag/AgCl reference electrode with ceramic diaphragm
- Shaft material :
Glass
- Shaft diameter top (mm) :
12
- Diaphragm :
Ceramic
- Bridge electrolyte type :
c(KCl) = 3 mol/L
- Resistance (kOhm) :
3
- Temperature range, short-term (C)0: ... 80
- SGJ sleeve :
flexible SGJ sleeve
- Reference electrolyte type :
c(KCl) = 3 mol/L (thickened)
- Temperature range, long-term (C) 0
: ... 80
- Electrolyte flow rate (l/h) :
5 ... 30 uL/h
- Plug for filling opening :
Orifice
- Shaft diameter bottom (mm) :
12
- Min. immersion depth (mm) :
10
- Internal reference electrode type : Ag/AgCl cartridge
- Electrode plug-in head :
Metrohm socket B
Pt-Auxilliary Electrode WOC
- Temperature range, long-term (C) -:20 ... 70
- Measuring unit :
mV
- Indicator electrode type :
Pt
- Shaft material :
Glass
- Shaft diameter top (mm) :
12
- Measuring range
-2000 ... 2000
- Temperature range, short-term (C)-20
: ... 70
- Shaft diameter bottom (mm) :
12
- Min. immersion depth (mm) :
10
- SGJ sleeve :
flexible SGJ sleeve
- Indicator electrode shape :
Wire
- Electrode plug-in head :
Metrohm plug-in head B

Page 7 of 7