Sie sind auf Seite 1von 4

Paladin Advantage

Universal Programmable Transducer

Paladin Advantage - Universal Transducer


The Paladin Advantage, 254-XZZ, is a programmable transducer which
provides measurement isolation and conversion of all main electrical
parameters into an industry standard DC output signal. The 254-XZZ
can be used in single and three-phase balanced or unbalanced three or
four-wire electrical systems. The 254-XZZ has an accuracy of CL0.2 and
includes RS485 Modbus RTU communications protocol and pulse/alarm
output as standard.
The 254-XZZ is an accurate device for the conversion of all main electrical
parameters into a Voltage or mA output and provides measurement,
isolation and conversion of up to four user defined inputs and outputs.
The device is supplied programmed to the users requirements but can
be easily be reprogrammed to suit any application.
Features
DIN-rail enclosure
Measurement, isolation and
conversion of up to 4 parameters
RS485 Modbus RTU protocol
Alarm/pulsed output
Programmable VT/CT ratio
True rms measurement
User programmable configuration

Designed, developed and manufactured in the EU, with integrated


microprocessor for exceptional waveform handling of distorted waveforms.
The 254-XZZ is ideal for low, medium and high voltage applications and
provides a high protection against continuous and short circuit protection
as well as galvanically isolated inputs and outputs.
Connection Diagrams

Benefits

Cost effective
CL 0.2 accuracy
EU manufactured
Modbus communications
Fully configurable

Applications
Motor control centres
Energy/building management
systems
Switchgear
Generators sets
3-phase 4-wire unbalanced

3-phase 3-wire unbalanced

3-phase 4-wire balanced

3-phase 3-wire balanced

Standards

IEC 61326
IEC 61010-1
IEC 62053-21
EN60688
RoHS Compliant

Dimensions
100 x 70 x 118 mm
3.94 x 3.11 x 4.65
Weight 0.42 kg

Single-phase

energy.te.com

TE Connectivity

Input Parameters

Specification
Input
Nominal input voltage
57.7V - 277V AC L-N (100 -480V L-L)

480V MAX
Max. continuous input
120% of nominal
overload voltage
Max. short duration input
2 x nominal voltage
voltage (300 msec)
Nominal input voltage burden
< 0.5VA per phase
Nominal input current
1A AC or 5A AC rms
Max. continuous input
2 x nominal voltage
overload current
Max. short duration input
20 x nominal current
current (300 msec)
Auxiliary
Operating range
80-260V AC/DC (+/- 10%) 45-66Hz, 6VA

or

20-60V AC/DC (+/- 10%) 45-66Hz, 6VA
Supply burden
6 VA
Accuracy
Voltage (V)
< 0.2%
Current (A)
< 0.2%
Neutral current calculated (A) < 1.0%
Frequency (Hz)
< 0.1 Hz
Power factor (PF)
1% of unity
Active power (W)
+/- 0.2% of range
Reactive power (VAr)
+/- 0.2% of range
Apparent power (VA)
+/- 0.2% of range
Active energy (kWh)
Class 0.2 (IEC 62053-21)
Reactive energy (kVArh)
+/- 0.2% of range
Response time
<200 msec
Range
Voltage (V)
5% to 120% for nominal
Current (A)
5% to 120% of nominal
Frequency
45-65 Hz
THD
up to 31st harmonic
Outputs
Analogue output
0... +/- 1mA
0... +/- 5mA

0... +/- 10mA
0... +/- 20mA

4... +/- 20mA

0... +/- 1V
2... +/- 10V

All programmable
Pulse/alarm output relay
User defined solid state relay
Pulse/alarm contact rating
100mA at 250V
Pulse duration
30msec to 1000 msec
Alarm delay
0-120 secs
Alarm hysteresis
1 - 99%
Alarm type
User Defined Solid State Relay
Communication protocol
RS485 Modbus RTU
Type
2-wire half duplex
Baud rate
9600, 19200, 38400
Enclosure
Enclosure style
DIN-rail mounting
Dimensions
100 x 79 x 118mm
Material
Polycarbonate to UL94-V0
Weight
0.42kg
Terminals
Shrouded screw-clamp 0.05-4mm wire
Environment
Operating temperature
-10C to +55C
Storage temperature
-30C to +70C
Relative humidity
0-90% non-condensing
Shock
30g in 3 planes
Vibration
10Hz to 50Hz
Dielectric voltage Withstand test 4kV, 50Hz for 1 minute
between auxiliary/input/output

Product Codes
Product codes

Part number

Paladin Advantage
Options
Auxiliary
80-260V AC/DC (+/- 10%) 45-66Hz, 6VA
20-60V AC/DC (+/- 10%) 45-66Hz, 6VA
Analogue Outputs
Two programmable outputs
Four programmable outputs

254-XZZ

energy.te.com

254-XZZ-M
254-XZZ-L
254-XZZ-*-02
254-XZZ-*-04

Button Id

Description

Voltage VL1

VL2

VL3

2VL12

VL23

VL31

AVG V12

V23 V31

AVG V1N

V2N V3N

DELTA V

DELTA VN
Current IL1

IL2

IL3

IN

AVG I1 I2 I3


DELTA I

I1 MAX

I2 MAX

I3 MAX

I1 AVG

I2 AVG

I3 AVG
Active P
Power P1

P2

P3

PMAX

PAVG
Reactive Q
Power Q1

Q2

Q3
Apparent S
Power S1

S2

S3
Power PF
Factor PF AVG

PF1

PF2

PF3
ANGLE SYS ANGLE

ANGLE L1

ANGLE L2

ANGLE L3

FREQ
THD
THDV1

THDV2

THDV3

THD I1

THD I2

THD I3
COSPHI COSPHI 1


COSPHI 2


COSPHI 3

Volts L1 - N
Volts L2 - N
Volts L3 - N
Volts L1 - L2
Volts L2 - L3
Volts L3 - L1
Average Vvlt
- age (L-L)
Average Vvltage (L-N)
Volts diff L-L
Volts diff L-N
Current L1
CurrentL2
Current L3
Neutral I
Average
Current
Current diff
I1 Max demand
I2 Max demand
I3 Max demand
Average I1
Average I2
Average I3
System power
Power L1
Power L2
Power L3
Max power
Average power
System VAr
Systme VAr L1
System VAr L2
System VAr L3
System VA
System VA L1
System VA L2
System VA L3
Power factor
Average PF
PF L1
PF L2
PF L3
System Angle
Phase Angle L1
Phase Angle L2
Phase Angle L3
Frequency
THD V1
THD V2
THD V3
THD I1
THD I2
THD I3
Displacememnt
P.F
Displacememnt
P.F
Displacememnt
P.F

About TE Connectivity

While TE has made every reasonable effort to ensure the accuracy of the information in this catalogue, TE does not guarantee that it is error-free, nor does TE make any other representation,
warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without
notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a
particular purpose. The dimensions in this catalogue are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult
TE for the latest dimensions and design specifications. TE connectivity (logo), TE (logo) and TE Connectivity are trademarks of the TE Connectivity Ltd. family of companies. Crompton is a
trademark of Crompton Parkinson and is used by TE Connectivity under a licence. Other logos, product and company names mentioned herein may be trademarks of their respective owners.
2014 TE Connectivity family of companies. All Rights Reserved.

TE Energy innovative and economical solutions for the electrical power industry: cable accessories, connectors & fittings,
insulators & insulation, surge arresters, switching equipment, street lighting, power measurement and control.
Tyco Electronics UK Ltd
TE Energy
Freebournes Road
Witham, Essex CM8 3AH
Phone: +44 (0)870 870 7500
Fax: +44 (0)870 240 5287
Email: Crompton.info@te.com

www.crompton-instruments.com
energy.te.com

Registered office:
Faraday Road, Dorcan
Swindon, SN3 5HH
Reg. no. 550 926

CI-EPP-2149-04/14_TRANSD_ADV

TE Connectivity is a global, $14 billion company that designs and manufactures over
500,000 products that connect and protect the flow of power and data inside the
products that touch every aspect of our lives. Our nearly 100,000 employees partner
with customers in virtually every industry from consumer electronics, energy and
healthcare, to automotive, aerospace and communication networks enabling
smarter, faster, better technologies to connect products to possibilities.

Das könnte Ihnen auch gefallen