Sie sind auf Seite 1von 26

5/1/B/5

VARYCONTROL
VAV Terminal Units
For variable volume flow systems
Type TVZ TVA

TROX UK Ltd
Caxton Way
Thetford
Norfolk IP24 3SQ

Telephone +44 (0) 1842 754545


Telefax
+44 (0) 1842 763051
e-mail trox@troxuk.co.uk
www.troxuk.co.uk

Contents Description
Contents Description
Functional description
Construction Dimensions
Nomenclature
Aerodynamic data
Acoustic quick selection TVZ TVZD
Air-regenerated noise TVZ TVZD,
without TS secondary silencer
Air-regenerated noise TVZ TVZD,
with TS secondary silencer
TVZ air regenerated noise with reheat without TS
TVZ air regenerated noise with reheat with TS
Case-radiated noise TVZ
Case-radiated noise TVZD
Fan (high pressure)
side air-regenerated noise TVZ TVZD

2
3
4
6
6
7
8
9
10
11
12
13
14

Type TVZ VAV terminal box

Type TVZD VAV terminal box

TROX VARYCONTROL VAV terminal boxes type TVZ and


TVZD as well as type TVA and TVAD were developed for the
control of air flow, especially in variable volume systems.
A special feature of these types is the outstanding acoustic
qualities that show themselves to the best advantage in
buildings with critical comfort criteria.

There is a circular spigot connection on the fan (high


pressure) end with a rectangular flange connection on the
room (low pressure) end.

TVZ: supply air box


TVZD: supply air box with additional acoustic
cladding
TVA: extract air box
TVAD: extract air box with additional acoustic
cladding
The mechanical components and electronic components
which are factory fitted, form the controls package. Each
box is set up to the required flow rates and is subjected to
an aerodynamic function test.
The boxes contain an averaging differential pressure sensor
for air flow measurement, a control damper and an integral
sound attenuator for reducing the air regenerated noise.
The control damper blade with plastic seal when closed
complies with the air tightness requirements of EN 1751.

Acoustic quick selection TVA TVAD


Air-regenerated noise TVA TVAD,
without TS secondary silencer
Air-regenerated noise TVA TVAD,
with TS secondary silencer
Case-radiated noise TVA
Case-radiated noise TVAD
Fan (high pressure)
side air-regenerated noise TVA TVAD
Control code BC0
Temperature Control
Electric heater
Water heater
Order details

The boxes with additional acoustic cladding and/or an TS


secondary silencer are suitable for very demanding acoustic
requirements.
The flow rate control is a closed circuit system with external
power supply. The pressure transducer, controller and
actuator are selected to meet the controls requirements and
operational conditions. The TROX VAV boxes can be
supplied with control components from any reputable
manufacturer to suit the project specification.
Further, current information on application, selection as well
as control components available can be found in the
Technical Documentation download area of our website.
Also available on the internet is TROX EASY PRODUCT
FINDER for design and selection of our units.

15
16
17
18
19
20
21
22
23
24
25

Functional Description
Room temperature controller

Volume flow control

In VAV systems, the room temperature control takes the form of


a cascade control. The primary controlled variable is the room
temperature. The output signal of the room temperature controller is not fed directly to the supply air control damper but
alters the setpoint value of the supply air flow rate control circuit.
The flow rate control also generates minimum and maximum
limits for the air flow which has benefits in keeping the room
temperature constant and for the functioning of the overall room
air conditioning system.

The control of the flow rate takes place in a closed control


circuit, i.e. measurement comparison control.
A pressure transducer converts the pressure differential into an
electrical signal, which is interpreted as the actual value by the
controller. In most applications, the setpoint value comes from a
room temperature controller.
The controller compares the actual value with the setpoint value
and from the difference between these two alters the control
signal to the damper actuator.

Flow rate measurement

Supply/extract air tracking control

A sensor is necessary for the positive measurement of air flows,


this is achieved by pressure measurement at several points
distributed over the cross-section and provision of the resulting
average value. The TROX differential pressure sensor is an
optimum solution in terms of economics and product
technology. This sensor delivers exact results for most room air
conditioning applications based on normal upstream flow
conditions.

In individual rooms and closed-off office areas, where the


balance between supply and extract air flow rate has to be maintained. Otherwise, annoying whistling noises can occur at door
gaps, and the doors can be difficult to open. For this reason, the
extract air should also have variable control in a VAV system.
The actual value of the supply air is fed as an input signal to the
extract air controller (slave controller). In this way, the extract air
flow rate automatically follows the supply air flow rate, even in
the case where this has not reached its setpoint value.

System diagram
pst

Supply
air

pst

Supply air
VAV terminal box TVZ

Extract air
VAV terminal box TVA

Room

Extract
air

Control signal for TVZ


Control signal for TVA

Legend

Control diagram

Differential pressure sensor

.
Vnom

Control damper blade


Pressure transducer

.
Vmax

Actuator
Flow rate controller
Room temperature controller (supplied by others)

Flow rate

Wiring by others

Supply air
Extract air

Entry flow conditions


Secondary duct

in

.
Vmin

.1
Main duct

Control signal to supply air flow rate controller


* with smaller length, the tolerances increase

min. 5D *

Construction Dimensions
Factory set up or programming of flow rate. This includes
aerodynamic function test of each box using a dedicated test
rig. Data covering set up is given on a test label attached to
each box
Flow rate can be measured and subsequently reset on site;
an additional adjuster unit may be necessary
Actual value signal referred to Vnom
The boxes are, in terms of their mechanical parts,
maintenance-free
Operating temperature range 10 to 50 C

Characteristics
Electronic flow rate control
Suitable for supply or extract air
Flow rate range (depending on manufacturer and type of
controller) approx. 10 :1
Very close control accuracy for the flow rate settings, even
with upstream bend at R = 1 D. Please ensure the most
favourable aerodynamic configuration of ductwork is used
(see diagram on page 3)
Differential pressure range 20 to 1500 Pa
Full shut-off from duct work system
Control damper closed blade airtightness to EN 1751, class 4
(nominal size 125, class 3)
Baffle plates are fitted after the control damper for optimum
acoustic and aerodynamic performance
Integral sound attenuator with at least 26 dB insertion loss at
250 Hz
Horizontal or vertical installation (when using diaphragm
pressure transducers, install according to label on the box)

Constructional features
Circular spigot on the fan (high pressure) side, this includes a
groove for the use of a lip seal, suitable for circular
connecting ducts to EN 1506 or EN 13180 (if lip seals are
required, these will be factory fitted)
Room (low pressure) side suitable for attachment of connecting flanges
Holes in the return edges of the casing for support rods
Casing air leakage complies with EN 1751, class A
Fulfils VDI 2083, clean room class 3 and US Federal
Standard 209E, class 100

TVZ TVA
L

A
70

70

Da

20

10

50

75 1)

typically
165

Optional control enclosure


Damper shaft

TVZD TVAD
A1

L1
70

70

B1

Da

20

10

50

Optional control enclosure

115
Note:

1)

2)

100 for size 250, 315 & 400

Damper shaft
2) 140

typically
165

K1
H1

for size 250, 315 & 400

Ensure adequate access is provided to control components.


Control components are situated on the right hand side when seen from the direction of airflow (with the folded seam upper most)!

Construction Dimensions
Casing

TS Secondary silencer

Casing in galvanised sheet steel


Lining in the sound attenuator section and in the control
damper chamber from mineral wool conforming to DIN 4102,
fire rating class A2, with RAL quality mark RAL-GZ 388, biodegradable pursuant to TRGS 905 and EU directive 97/69/EG
Mineral wool faced with fibreglass as protection against
erosion, suitable for air velocities up to 20 m/s, inert to fungal
and bacterial growth
Control damper blade in galvanised sheet steel with
thermoplastic elastomer seal
Sensor tubes in aluminium
Plastic plain bearings

Casing in galvanised sheet steel


Lining from mineral wool conforming to DIN 4102, fire rating
class A2, with RAL quality mark RAL-GZ 388, bio-degradable
pursuant to TRGS 905 and EU directive 97/69/EG
Mineral wool faced with fibreglass as protection against
erosion, suitable for air velocities up to 20 m/s, inert to fungal
and bacterial growth
Suitable for the TVZ/TVA box
Suitable for attachment of connecting flanges

Reheat Coil

Additional acoustic cladding


Outer cover in galvanised sheet steel
Sound-absorbent lining
Rubber isolators for the insulation of structure-borne noise
Cannot be retro-fitted

Additional Fixing
Holes in Centre
for sizes 250-400
10 holes
in top
flange

10

30

TS or duct connection
Compression seal, by
customer

M8

Slide on flange

RxG

30

70

70

30

TS Secondary Silencer

L 2 - 56
L2

TS or duct
connection

Reheat Coil

Rectangular duct connection

4)

Reheat coil connection


70*
56*

30

C
E

M8

30 3)

Additional Fixing Holes in Centre for sizes 250-400

R1/2"

For terminal reheat of primary air volume


Casing made of galvanised sheet steel
Flanged on both ends
Copper tubes and aluminium fins
One or two row (four-row formed by combination)
Available factory-fitted or supplied separately
Maximum operating pressure 16 bar
Water connections horizontal, air venting by customer

reheat coil

10

Dimensions in mm

Weight in kg

Duct connections
Size

Casing
A
A1
TVZ TVA TVZD TVAD

1RR/2RR
or 4RR

* 140/126 mm for four-row

TVZ TVZD
Nom.
TS
size TVA TVAD

Reheat
Coil
(2RR)

Da

B1

H1

K1

125

124

186

232

152

198

150

185

110

145

300

380

152

236

316

56

56

1035 1075 806

125

21

41

10

2.4

160

159

186

342

152

308

200

170

160

130

410

490

152

236

316

62

72

1035 1075 806

160

25

50

15

3.3

200

199

244

492

210

458

200

140

160

100

560

640

203

281

361

53

58

1320 1360 956

200

33

63

22

4.8

250

249

235

632

201

598

250

100

210

60

700

780

203

311

391

57

57

1440 1480 956

250

55

95

37

6.0

315

314

286

832

252

798

250

250

210

210

900

980

254

361

441

70

70

1440 1480 1056

315

73

133

42

8.7

400

399

388

932

354

898

250

180

210

140 1000 1080 356

446

526

62

62

1820 1860 1306

400

118

193

50

12.7

Note

3)

25 for size 400

4)

L1

L2

Duct connection dimensions R x G

Nomenclature Aerodynamic Data

Nomenclature
fm
LW

in Hz: Octave band centre frequency


in dB: Sound power level of the air-regenerated noise
in the room (low pressure) side ducting
in dB: Sound power level of the air-regenerated noise with TS
secondary silencer
in dB: Sound power level of the case-radiated noise
in dB: Sound power level of the case-radiated noise with additional
acoustic cladding
in dB: Sound power level of the air-regenerated noise
in the fan (high pressure) side ducting
in dB(A): A-weighted sound pressure level of air-regenerated noise,
system attenuation taken into account
in dB(A): A-weighted sound pressure level of air-regenerated noise with
TS secondary silencer, system attenuation taken into account
in dB(A): A-weighted sound pressure level of case-radiated noise,
system attenuation taken into account
in dB(A): A-weighted sound pressure level of case-radiated noise with
additional acoustic cladding, system attenuation taken into
account
in dB: Insertion loss
3
in m /h
and l/s: Nominal flow rate (100 %)
in m3/h
and l/s: Flow rate
in %: Flow rate tolerance from setpoint value

L W1
L W2
L W3
L WR
L pA
L pA1
L pA2
L pA3
De
Vnom
V
 V

 pst
 pst min
NR :

in Pa: Static pressure differential


in Pa: Minimum static pressure differential
Noise Rating of sound pressure spectrum, assuming a 8
dB/oct. room attenuation.
L in dB(A) :
A-weighted sound pressure (re 20Pa) of air-regenerated noise,
assuming reflection attenuation and 8 dB/Oct. room
attenuation.
L indBor
NC: Level correction values for TVZ with air heater
RR:
Number of rows
K:
Number of circuits (distributors)

m
in kg/s: Mass flow (water)
w

m
in kg/s: Mass flow per circuit
wK
Q
in kW: Heat output
te
inC: Inlet air temperature
ta
inC: Discharge air temperature
twm
in C: Mean water temperature
v
in m/s: Air velocity in rectangular duct
pv
in kPa: Water pressure drop
t
in K: Air temperature differential
tw
in K: Water temperature differential
All sound power levels are based on 1 pW, all sound pressure levels on 20 Pa.
All noise levels determined in a reverberation chamber. The sound power data was
determined and corrected according to ISO EN 5135, February 1999.

Flow rate ranges and minimum pressure differentials with dynamic pressure transducer
V

V 1)

 pst min in Pa

Nominal size

TVZ with reheat coil


l/s

125

160

200

250

315

400

1)

m /h
3

TVZ

1RR

TVA

TS 2)

2RR

15

54

19

20

20

40

20

60

216

20

30

40

25

105

378

45

80

110

80

20

150

540

90

140

190

150

40

25

90

19

20

20

20

20

80

288

20

30

40

25

145

522

45

55

80

50

10

250

900

80

140

200

150

20

40

144

19

20

20

20

20

180

648

20

30

40

30

310

1116

40

70

100

95

10

405

1458

80

130

180

190

20

60

216

19

20

20

20

20

270

972

20

35

45

25

470

1692

40

80

110

75

10

615

2214

80

145

210

150

20

105

378

19

20

20

10

20

425

1530

20

35

45

30

10

740

2664

40

75

110

90

20

1025

3690

80

140

195

180

40

170

612

19

20

20

20

20

715

2574

20

35

50

25

10

1250

4500

40

80

120

75

20

1680

6048

80

150

210

150

40

typical figures for uniform entry flow

2) additional

pressure differential to be taken into account

Acoustic Quick Selection TVZ TVZD

System attenuation in dB/oct. acc. to VDI 2081 (taken into account in the quick selection table)
fm in Hz

63

125

250

500

1000

2000

4000

8000

Duct bend attenuation

Room attenuation

End reflection

10

Correction for distribution into the low pressure duct system (taken into account in the quick selection table)
.
V

m3/h

500

1000

1500

2000

2500

3000

4000

5000

6000

l/s

139

278

417

556

695

834

1111

1389

1667

10

11

dB per octave

Correction for the calculation of the case-radiated noise (taken into account in the quick selection table)
Ceiling reduction in dB/oct.

Room attenuation in dB/oct.

Quick selection sound pressure level in dB(A)


 pst = 100 Pa
V

Nominal
size

l/s
125

160

200

250

315

400

 pst = 200 Pa

 pst = 500 Pa

Air-regenerated noise Case-radiated noise Air-regenerated noise Case-radiated noise Air-regenerated noise Case-radiated noise

m3/h

TVZ
LpA

TVZ+TS
LpA1

TVZ
LpA2

TVZD
LpA3

TVZ
LpA

TVZ+TS
LpA1

TVZ
LpA2

TVZD
LpA3

TVZ
LpA

TVZ+TS
LpA1

TVZ
LpA2

TVZD
LpA3

15

54

15

15

20

13

18

14

21

13

19

14

23

14

60

216

22

19

21

15

25

15

25

16

26

16

31

21

105

378

28

23

25

18

29

16

29

20

35

20

34

24

150

540

34

28

30

22

37

23

33

24

40

25

36

27

25

90

16

15

17

13

22

14

19

13

20

14

25

15

100

360

28

23

22

16

29

17

25

18

32

18

32

23

175

630

33

27

26

19

36

21

30

22

37

22

36

27

250

900

35

29

32

24

37

22

35

27

41

26

39

31

40

144

15

14

19

14

17

14

22

14

19

14

29

18

160

576

20

17

24

18

22

13

28

20

28

15

35

25

280

1008

21

16

28

21

24

13

32

24

30

16

38

29

405

1458

30

23

36

29

32

17

39

31

34

21

43

34

60

216

15

14

19

14

17

14

23

15

19

14

29

18

250

900

17

14

23

18

20

12

28

20

26

15

35

26

430

1548

23

14

26

20

26

14

31

24

30

19

38

30

615

2214

29

20

34

26

32

18

38

30

36

24

43

35

100

360

17

15

19

14

18

14

22

14

22

15

31

20

410

1476

19

15

23

17

23

14

29

21

32

22

39

29

720

2592

21

16

30

22

25

18

35

26

33

24

42

33

1025

3690

28

20

35

28

31

20

40

31

37

27

45

37

170

612

16

14

22

15

18

13

26

18

23

16

34

24

671

2416

18

13

25

19

22

15

31

23

30

22

42

32

1175

4230

25

19

31

25

28

22

35

29

32

26

43

34

1680

6048

31

26

43

37

34

26

45

40

38

31

48

42

For acoustic data for differential pressure up to 1000 Pa, refer to TROX EASY PRODUCT FINDER

Air-regenerated Noise TVZ TVZD


without TS secondary silencer

LW

TVZ

LWR

LW2
LW3

LW1

Additional acoustic cladding


TS secondary silencer
Air distributed between several diffusers
Duct bend
End reflection based on diffuser

without additional acoustic cladding


with additional acoustic cladding

Insertion loss

Room

D e in dB
f m in Hz
2000

4000

8000

Nomenclature, see page 6

1000

TS secondary
LpA1 with
silencer

500

Type / nominal size

250

with additional
acoustic cladding Microphone

125

LpA3

without TS secondary
LpA silencer

63

additional
LpA2 without
acoustic cladding

TVZ 125 to 200 without TS

15

18

26

37

42

39

32

23

TVZ 125 to 200 with TS

21

25

32

47

47

45

37

29

TVZ 250 to 400 without TS

20

25

31

45

45

42

37

31

TVZ 250 to 400 with TS

25

32

42

53

52

50

45

38

Air-regenerated noise TVZ without TS secondary silencer

200

250

315

400

L W in dB

L W in dB

L W in dB

f m in Hz

f m in Hz

f m in Hz

63

125

250

500

1000

2000

4000

8000

63

125

250

500

1000

2000

4000

8000

63

125

250

500

1000

2000

4000

8000

15

54

50

26

18

15

15

15

15

16

55

32

25

16

<

<

<

19

56

31

25

16

<

<

<

22

60

216

47

44

35

18

15

15

15

15

51

47

37

22

<

<

<

22

53

46

41

26

<

<

15

22

105

378

54

50

41

25

16

15

15

15

57

51

43

28

19

<

<

19

58

58

47

32

20

<

18

28

150

540

56

51

49

36

23

15

15

15

59

54

51

42

37

33

19

20

62

60

55

38

28

20

18

29

25

90

50

33

24

15

15

15

15

15

53

45

29

17

<

<

<

19

55

37

29

20

<

<

<

19

100

360

52

52

39

21

15

21

16

16

55

53

41

25

15

<

19

21

56

54

45

34

26

23

21

23

175

630

55

54

49

30

23

15

15

15

58

56

52

33

25

17

17

20

60

60

52

37

28

20

18

27

250

900

63

59

51

38

33

27

17

16

65

61

53

40

35

29

21

22

66

66

56

44

38

33

25

31

40

144

33

29

23

15

15

15

15

17

51

32

26

15

<

<

15

20

42

33

29

19

16

<

<

23

160

576

46

43

33

16

15

15

15

15

50

45

36

21

<

<

<

<

58

49

41

30

15

<

<

25

280

1008

51

45

37

27

21

15

15

15

55

48

40

31

23

17

<

19

58

53

47

34

25

18

<

28

405

1458

59

54

46

38

33

28

21

15

64

56

49

40

35

30

24

22

64

57

50

44

39

34

27

31

60

216

36

34

20

15

15

15

15

15

42

36

25

15

<

<

<

18

46

40

28

15

<

<

<

20

250

900

47

42

28

17

15

15

15

15

50

45

33

22

15

<

<

18

55

50

41

29

22

20

21

26

430

1548

52

45

36

33

28

24

21

25

56

50

41

36

31

27

24

28

59

57

46

37

32

28

27

31

615

2214

60

52

44

40

36

33

32

33

63

56

48

43

39

36

34

36

66

60

52

46

42

39

36

39

100

360

35

36

28

15

15

15

15

15

41

37

31

15

<

<

<

<

49

38

35

23

17

<

<

22

410

1476

49

46

37

16

15

15

15

25

53

49

41

22

<

<

15

29

61

58

49

33

31

29

30

37

720

2592

57

47

38

25

21

15

23

34

60

52

43

30

26

20

27

37

65

60

51

39

37

35

35

42

1025

3690

65

54

49

37

34

31

29

34

67

58

53

41

37

34

34

38

72

65

54

47

45

42

41

45

170

612

35

35

28

15

15

15

15

15

41

38

32

<

<

<

<

<

41

43

37

24

16

<

20

25

671

2416

51

48

34

22

19

18

19

23

54

51

39

27

24

23

26

30

58

56

50

34

31

30

34

38

1175

4230

66

53

43

36

35

30

30

35

67

56

47

39

37

33

34

39

69

61

52

40

38

36

39

44

1680

6048

72

63

45

42

39

39

37

41

78

65

50

45

42

41

41

45

78

67

57

50

49

46

46

50

< indicates values below 15

 pst = 500 Pa

m3/h

l/s

160

 pst = 200 Pa

Nominal
size

125

 pst = 100 Pa

Air-regenerated Noise TVZ TVZD


with TS secondary silencer

Air-regenerated noise calculation procedure

Example
Given: Vmax = 280 l/s (1008 m3/h)
 pst = 500 Pa
Required sound pressure level in the room 35 dB(A)

fm
LW (page 8)

For further assumptions, see calculation procedure

Distribution

Duct bend

End
reflection

10

Sound power
level to room

45

45

41

29

19

12

22

26 16

+1

+1

27

21

15

17

63 125 250 500 1000 2000 4000 8000


58 53 47 34
25
18
15
28

Calculation procedure

Room attenuation

Quick selection:

A-weighting

TVZD 200
L pA = 30 dB(A)
L pA3 = 29 dB(A)

Corrected level

Total sound pressure level in the room = 33 dB(A)


(after logarithmic addition, as the box is in the false ceiling of
the room, see sketch on page 8)

13

23

Sound pressure level of the air regenerated noise L pA = 30 dB(A)

Air-regenerated
Air-regenerated
noise
noise
TVZ
TVZ
without
with TSTS
secondary
secondary
silencer
silencer
 ppstst == 100
100 Pa
Pa

160

200

250

315

400

L W in
L WdB
in dB

L W in
L WdB
in dB

in Hz
f m inf mHz

in Hz
f m inf mHz

in Hz
f m in
f mHz

63
63
125
125
250
250
500
500
1000

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

63
63
125
125
250
250
500
500
1000

2000
1000

4000
2000
8000
4000
L in dB(A)
8000
NR

50
49 2622 181515 15
15 15 15
15 1615

15

55
53 3229 25 2116 <<

<<

<< 19 <

<

56
54 31
28 252116 <<

<

<< 22 <

15

60

216

47
45 4440 353018 15
15 15 15
15 1515

15

51
49 4743 37 3222 16
<

<<

<< 22 <

15

53
51 46
42 413626 16<

< 15< 22 <

15

105

378

54
51 5045 413625 15
16 15 15
15 1515

15

57
54 5147 43 3828 16
19

<<

<< 19 <

<

58
55 58
54 474232 19
20 < 18< 28 <

20

150

540

56
52 5148 494436 26
23 21
15 15
17 1515

15

59
57 5450 51 4642 27
37 33
22 1919 20 <

<

62
58 60
55 554938 28
28 23
20 18
18 29 <

21

2000
1000

54

m3/h

63
63
125
125
250
250
500
500
1000

15

l/s
125

 pstst ==500
500Pa
Pa

L W in
L WdB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

 ppstst == 200
200 Pa
Pa

25

90

50
48 3327 241715 15
15 15 15
15 1515

15

53
51 4541 29 2217 <<

<<

<< 19 <

<

55
53 37
33 292220 <<

<< 19 <

<

100

360

52
50 5248 393221 15
15 15
21 16
15 1615

15

55
53 5349 41 3425 15
15

<< 19< 21 <

16

56
54 54
50 453834 20
26 23
< 21< 23 <

18

175

630

55
52 5450 494330 17
23 15 15
15 1515

15

58
55 5652 52 4533 19
25 17
< 17< 20 <

15

60
58 60
56 524537 23
28 15
20 18< 27 <

21

250

900

63
60 5955 514438 23
33 18
27 17
15 1615

15

65
63 6157 53 4640 25
35 29
20 2116 22 <

17

66
64 66
62 564944 30
38 25
33 25
20 31 <

25

<

40

144

33
34 2925 231515 15
15 15 15
15 1715

15

51
49 3228 26 1815 <<

<< 15< 20 <

<

42
40 33
29 292119 <16 <

<< 23 <

<

160

576

46
44 4339 332516 15
15 15 15
15 1515

15

50
48 4541 36 2821 15
<

<<

<< < <

<

58
56 49
45 413330 20
15 <

<< 25 <

<

280

1008

51
49 4541 372927 18
21 15 15
15 1515

15

55
53 4844 40 3231 21
23 17
<

<< 19 <

<

58
56 53
49 473934 24
25 15
18 << 28 <

15

405

1458

59
58 5450 463938 27
33 17
28 21
15 1515

15

64
61 5652 49 4140 29
35 30
21 24< 22 <

<

64
62 57
53 504344 35
39 29
34 27
23 3117

18

60

216

36
34 3430 201515 15
15 15 15
15 1515

15

42
40 3632 25 1615 <<

<<

<< 18 <

<

46
44 40
36 281815 <<

<

250

900

47
45 4238 281817 15
15 15 15
15 1515

15

50
48 4541 33 2322 15
15

<<

<< 18 <

<

55
53 50
46 413129 16
22 20
< 21< 26 <

19

430

1548

52
50 4541 362633 20
28 15
24 21
15 2515

17

56
54 5046 41 3136 22
31 27
17 24< 28 <

20

59
57 57
53 463737 28
32 23
28 27
18 31 <

23

615

2214

60
58 5248 443440 27
36 23
33 32
18 3318

25

63
61 5652 48 3843 28
39 36
24 3421 3620

28

66
64 60
56 524446 37
42 33
39 36
29 3924

31

100

360

35
33 3632 281915 15
15 15 15
15 1515

15

41
39 3733 31 2215 <<

<<

<

49
47 38
34 352623 <17 <

<< 22 <

16

410

1476

49
47 4642 372816 15
15 15 15
15 2515

19

53
51 4945 41 3222 <<

<< 15< 29 <

23

61
59 58
54 494033 20
31 19
29 30
17 3719

31

720

2592

57
55 4743 382925 15
21 15 23
16 3415

28

60
58 5248 43 3430 18
26 20
15 27< 3717

31

65
63 60
56 514239 29
37 26
35 35
23 4224

36

1025

3690

65
63 5450 494037 24
34 21
31 29
19 3419

28

67
65 5854 53 4441 28
37 34
25 3422 3823

32

72
70 65
61 544647 39
45 35
42 41
31 4531

39

170

612

35
32 3531 281915 15
15 15 15
15 1515

15

41
39 3834 32 23<

<< < <

<

41
39 43
39 372824 <16 < 20< 25 <

21

<<

<<

<< < <

<

<< 20 <

671

2416

51
49 4844 342522 15
19 15
18 19
15 2315

19

54
52 5147 39 3027 18
24 23
15 2615 3020

26

58
56 56
52 504134 24
31 21
30 34
20 3827

34

1175

4230

66
64 5349 433436 27
35 25
30 30
20 3523

31

67
65 5652 47 3839 29
37 33
27 3423 3927

35

69
67 61
57 524340 31
38 29
36 39
26 4432

40

1680

6048

72
73 6359 453642 32
39 29
39 37
29 4130

37

78
76 6561 50 4145 35
42 41
32 4131 4534

41

78
76 67
63 574850 41
49 40
46 46
36 5039

46

< indicates values below 15

< indicates values below 15

< indicates values below 15

TVZ Air-Regenerated Noise with Reheat Coil


without TS secondary silencer

Correction Values
Number of rows
 L in dB

1RR

2RR

4RR 1)

Note: 1) minimum pressure differential as in page 6.

Air-regenerated noise TVZ with Reheat coil without TS secondary silencer

200

250

315

400

500

1000

16

<

<

<

21

60

41

36

23

<

15

15

22

53

46

41

27

19

27

25

23

58

58

47

35

31

39

35

33

62

60

55

44

41

<

<

<

19

55

37

29

20

<

<

<

20

54

49

41

28

32

25

16

<

35

126

57

43

35

18

<

60

216

51

47

37

24

17

95

342

57

51

44

33

30

150

540

61

56

52

45

42

25

90

53

45

29

17

65

234

52

48

40

23

100

8000

250
25

55

4000

125
31

54

2000

63
56

1000

19

500

<

250

<

125

8000

f m in Hz
4000

f m in Hz

15

<

<

22

<

<

23

17

17

22

28

26

29

38

37

35

16

<

<

19

17

<

<

23

360

55

53

41

27

21

19

20

21

56

54

45

34

27

24

22

23

170

612

58

56

52

37

33

31

29

27

60

60

52

40

35

32

30

30

250

900

66

62

55

47

44

32

40

38

67

66

57

49

46

44

41

40

40

144

51

32

26

17

15

<

<

15

42

33

29

19

19

<

<

23

110

393

47

41

34

22

15

<

<

<

55

44

37

28

17

<

<

22

180

648

50

46

37

30

27

25

22

19

58

49

42

33

28

26

23

26

280

1008

57

51

45

41

39

37

34

31

29

54

49

43

40

38

36

34

405

1458

67

61

56

53

51

49

47

45

67

62

57

55

52

51

49

46

60

216

42

36

26

20

20

17

15

19

46

40

28

17

21

20

17

21

170

612

48

39

31

23

20

17

15

15

49

44

37

28

21

19

17

19

280

1008

51

46

38

34

31

30

27

24

56

51

43

36

33

31

29

28

470

1692

61

56

51

49

47

45

43

40

62

59

53

50

48

46

44

42

615

2214

68

64

60

58

56

54

52

50

70

65

61

59

57

55

54

51

105

378

41

37

31

19

22

19

17

<

49

38

35

25

19

16

<

22

265

954

53

47

40

29

22

19

17

25

52

51

45

29

27

24

27

34

420

1512

54

50

43

35

33

32

29

30

61

58

49

38

36

34

33

37

720

2592

62

57

52

49

48

46

44

42

66

61

55

50

49

47

45

45

1025

3690

70

65

61

59

58

56

54

52

73

68

63

60

59

57

56

54

170

612

41

38

33

21

22

20

17

<

41

43

37

27

19

16

20

25

445

1620

51

48

38

28

26

24

23

24

55

53

49

32

29

28

31

35

710

2556

55

52

43

39

38

36

34

33

59

56

51

41

39

38

37

39

1250

4500

68

60

56

54

53

51

49

47

70

63

58

55

54

52

50

49

1680

6048

78

69

65

63

62

60

59

57

79

71

67

64

63

62

60

58

< indicates values below 15

10

L W in dB

63

160

L W in dB

m3/h

l/s
125

 pst = 500 Pa

2000

Nominal
size

 pst = 200 Pa

TVZ Air-Regenerated Noise with Reheat Coil


with TS secondary silencer

Correction Values
Number of rows (RR)
 L in dB

1RR

2RR

4RR 1)

Note: 1) minimum pressure differential as in page 6.


Component layout, in the direction of the air flow, when
measuring acoustic data:
TVZ-box, reheat coil, TS attenuator

Air-regenerated noise TVZ with Reheat coil with TS secondary silencer

200

250

315

400

1000

2000

4000

8000

63

125

250

500

1000

2000

4000

8000

f m in Hz

500

f m in Hz

<

<

<

<

55

30

17

<

<

<

<

<

29

<

<

<

<

<

59

40

30

16

<

<

<

<

31

16

<

<

<

<

52

45

35

18

<

<

<

<

23

<

<

<

<

57

57

41

25

16

<

<

18

34

25

<

<

21

61

59

49

33

24

<

<

23

21

<

<

<

<

<

52

34

21

<

<

<

<

<

32

<

<

<

<

<

51

46

33

17

<

<

<

<

125

160

L W in dB

<

63

125

L W in dB

17

m3/h

15

54

54

31

35

126

56

42

60

216

50

46

95

342

56

50

38

150

540

60

55

46

25

90

50

42

65

234

49

45

100

l/s

 pst = 500 Pa

250

Nominal
size

 pst = 200 Pa

360

52

50

33

16

<

<

<

<

53

51

37

22

<

<

<

<

170

612

55

53

44

24

17

<

<

15

57

57

44

27

19

<

<

17

250

900

63

59

47

34

27

18

<

24

64

63

49

36

29

19

18

26

40

144

47

28

<

<

<

<

<

15

38

29

19

<

<

<

<

<

110

393

43

37

24

15

<

<

<

<

51

40

27

<

<

<

<

<

180

648

47

42

28

16

<

<

<

<

54

45

32

19

<

<

<

<

280

1008

53

47

35

26

21

16

<

16

55

50

39

28

22

17

<

18

405

1458

63

57

46

38

33

27

20

29

63

58

47

40

34

29

21

30

60

216

40

31

<

<

<

<

<

15

44

35

16

<

<

<

<

15

170

612

46

34

19

<

<

<

<

<

47

39

25

<

<

<

<

<

280

1008

49

41

25

15

<

<

<

<

54

46

30

15

<

<

<

15

470

1692

59

51

38

25

18

16

16

25

60

54

40

26

18

17

17

27

615

2214

66

59

47

34

26

25

25

35

68

60

48

35

27

26

26

36

105

378

38

33

21

<

<

<

<

<

46

34

25

<

<

<

<

<

265

954

51

43

30

<

<

<

<

16

49

47

35

<

<

<

<

23

420

1512

51

46

33

16

<

<

<

20

58

54

39

19

15

<

15

26

720

2592

59

53

42

29

25

24

25

31

63

57

45

31

26

25

27

34

1025

3690

67

61

51

39

35

34

35

41

70

64

53

40

36

35

37

43

170

612

37

34

25

<

<

<

<

<

37

39

29

<

<

<

<

17

445

1620

47

44

30

<

<

<

<

17

51

49

41

17

<

15

21

27

710

2556

51

48

35

24

21

21

23

25

55

52

43

25

23

23

26

31

1250

4500

64

56

48

38

36

36

38

39

66

59

50

39

37

37

39

41

1680

6048

74

65

57

47

45

45

48

49

75

67

59

48

46

47

49

50

< indicates values below 15

11

Case-radiated Noise TVZ


Case-radiated noise calculation procedure
fm
LW3 (page 11)

63 125 250 500 1000 2000 4000 8000


53 49 43 33
25
24
20
23

Ceiling reduction
Sound power
level to room

49

45

39

29

21

20

16

19

Room attenuation
A-weighting

26 16

Corrected level

17

23

+1

+1

25

21

17

17

13

14

Sound pressure level of the case-radiated noise L pA3 = 29 dB(A)


Result:

Note the above deviates from the room correction


on page 7, here other values have been assumed.
The result lies, however, within that required.

Case-radiated
Air-regenerated
noise
noise
TVZTVZ
without
without
additional
TS secondary
acousticsilencer
cladding
ppstst == 100
100 Pa
Pa

160

200

250

315

400

in Hz
f m inf mHz

in Hz
f m inf mHz

2000
1000

63
63
125
125
250
250
500
500
1000

2000
1000

15

55
27 32
31 252716 26<

27
< <20 19 <

<

56
20 3135 252816 27<

28
< <25 2224

22

60

216

47
35 4440 35 3318 26
15 15
21 15
17 1515

18

51
38 47
42 373522 30<

27
< <23 2216

20

53
38 4646 414026 37<

34
< 15
31 2227

25

105

378

54
41 5045 41 3925 31
16 15
25 15
22 1516

16

57
42 51
46 434028 33
19 29
< <26 1921

21

58
46 5850 474332 40
20 36
< 18
33 2829

27

150

540

56
45 5146 49 4336 37
23 15
29 15
27 1518

19

59
47 54
49 514542 40
37 33
34 19
31 2025

25

62
51 6054 554638 43
28 20
38 18
34 2932

29

2000
1000

50
< 2628 18 2615 26
15 15
26 15
17 1615

63
63
125
125
250
250
500
500
1000

63
63
125
125
250
250
500
500
1000

4000
2000
8000
4000
L in dB(A)
8000
NR

in Hz
f m inf mHz

4000
2000
8000
4000
L in dB(A)
8000
NR

LW L
inW2dB
in dB

54

m3/h

25

90

50
22 3328 24 2315 25
15 15
21 15
15 1515

15

53
25 45
28 292517 26<

24
< <18 19 <

16

55
21 3733 292820 28<

29
< <28 1924

24

100

360

52
36 5240 39 3521 27
15 21 16
19 1615

16

55
39 53
42 413725 31
15 27
< 19
25 2119

22

56
44 5446 454134 38
26 23
35 21
32 2328

29

175

630

55
46 5442 49 4030 31
23 15
23 15
23 1516

22

58
48 56
45 524233 35
25 17
29 17
28 2023

27

60
49 6050 524637 42
28 20
37 18
35 2732

32

250

900

63
48 5946 51 4638 38
33 27
31 17
27 1622

28

65
51 61
49 534840 42
35 29
35 21
32 2228

32

66
55 6654 565144 47
38 33
40 25
36 3135

35

40

144

33
30 2932 23 2915 28
15 15
20 15
18 1715

18

51
31 32
32 263015 29<

25
< 15
21 2018

22

42
27 3334 293419 36
16 33
< <30 2326

26

160

576

46
42 4341 33 3716 27
15 15
22 15
21 1525

24

50
46 45
44 364121 33<

29
< <27 < 27

29

58
49 4948 414630 42
15 37
< <34 2532

33

280

1008

51
48 4544 37 4327 30
21 15
25 15
25 1526

25

55
51 48
47 404631 36
23 17
31 <30 1928

30

58
55 5352 475034 44
25 18
39 <37 2835

37

405

1458

59
53 5450 46 5138 43
33 28
33 21
32 1530

34

64
56 56
53 495340 46
35 30
38 24
36 2235

38

64
60 5756 505444 51
39 34
43 27
40 3140

42

60

216

36
25 3431 20 2915 26
15 15
23 15
15 1515

15

42
28 36
33 253215 30<

27
< <21 18 <

<

46
36 4036 283515 34<

33
< <31 2026

23

250

900

47
50 4242 28 3517 26
15 15
20 15
19 15 <

15

50
52 45
46 334022 33
15 29
< <26 1821

23

55
53 5051 414729 42
22 20
37 21
35 2632

32

430

1548

52
50 4547 36 3733 29
28 24
21 21
23 2519

19

56
54 50
51 414436 37
31 27
31 24
30 2827

28

59
58 5756 465137 44
32 28
39 27
38 3136

37

615

2214

60
55 5250 44 4740 41
36 33
28 32
32 3326

28

63
58 56
54 485143 45
39 36
35 34
36 3632

34

66
62 6059 525546 50
42 39
42 36
40 3940

41

100

360

35
34 3636 28 2715 25
15 15
22 15
15 1515

15

41
35 37
36 313115 29<

26
< <20 < <

<

49
40 3838 353823 37
17 34
< <32 2228

22

410

1476

49
49 4642 37 3616 27
15 15
21 15
20 2515

15

53
52 49
46 414222 34<

29
< 15
27 2924

20

61
56 5853 495033 45
31 29
40 30
38 3736

33

720

2592

57
55 4747 38 4225 37
21 15
26 23
28 3421

24

60
58 52
51 434730 42
26 20
33 27
33 3729

30

65
61 6058 515539 48
37 35
42 35
41 4240

37

1025

3690

65
61 5451 49 4937 39
34 31
30 29
35 3429

28

67
64 58
55 535341 44
37 34
36 34
39 3835

34

72
68 6562 545747 51
45 42
43 41
42 4543

39

170

612

35
37 3538 28 3215 28
15 15
25 15
20 1515

15

41
40 38
40 3236< 33<

30
< <26 < 19

15

41
44 4342 374224 39
16 37
< 20
36 2532

22

671

2416

51
52 4842 34 3722 26
19 18
24 19
25 2318

25

54
56 51
47 394327 35
24 23
32 26
32 3027

30

58
59 5656 505534 47
31 30
41 34
40 3840

31

1175

4230

66
62 5345 43 3936 29
35 30
26 30
31 3523

23

67
67 56
52 474739 39
37 33
34 34
37 3932

30

69
67 6159 525540 48
38 36
42 39
42 4443

31

1680

6048

72
76 6360 45 5242 44
39 39
32 37
38 4132

32

78
77 65
62 505545 48
42 41
37 41
41 4537

36

78
79 6763 575850 51
49 46
42 46
44 5046

36

< indicates values below 15

12

LW L
inW2dB
in dB

15

l/s
125

 pstst ==500
500Pa
Pa

LW L
inW2dB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppstst == 200
200 Pa
Pa

< indicates values below 15

< indicates values below 15

Case-radiated Noise TVZD

Case-radiated
Air-regenerated
noise
noise
TVZD
TVZwith
without
additional
TS secondary
acousticsilencer
cladding

160

200

250

315

400

L W LinW3dB
in dB

in Hz
f m inf mHz

in Hz
f m inf mHz

in Hz
f m in
f mHz

2000
1000

63
63
125
125
250
250
500
500
1000

2000
1000

50
16 26
19 181915 16
15 15 15
15 1615

15

55
25 32
22 252016 16<

15
< << 19 <

<

56
18 3126 252116 17<

16
< << 22 <

<

60

216

47
33 44
31 352618 16
15 15 15
15 1515

15

51
36 47
33 372822 20<

15
< << 22 <

<

53
36 4637 413326 27<

22
< 15
18 22 <

<

105

378

54
39 50
36 413225 21
16 15 15
15 1515

15

57
40 51
37 433328 23
19 17
< << 19 <

<

58
44 5841 473632 30
20 24
< 18
20 28 <

<

150

540

56
43 51
37 493636 27
23 17
15 15
15 1515

15

59
45 54
40 513842 30
37 33
22 19
18 20 <

<

62
49 6045 553938 33
28 20
26 18
21 2917

15

2000
1000

54

m3/h

63
63
125
125
250
250
500
500
1000

63
63
125
125
250
250
500
500
1000

4000
2000
8000
4000
L in dB(A)
8000
NR

LW L
inW3dB
in dB

15

l/s
125

 ppstst ==500
500Pa
Pa

LW L
inW3dB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppstst==200
200Pa
Pa

4000
2000
8000
4000
L in dB(A)
8000
NR

ppstst==100
100Pa
Pa

25

90

50
15 33
20 241715 16
15 15 15
15 1515

15

53
23 45
22 291917 17<

<

<< 19 <

<

55
19 3727 292220 19<

16
< <16 19 <

<

100

360

52
34 52
34 392921 18
15 15
21 16
15 1615

15

55
37 53
36 413125 22
15

< 19< 21 <

<

56
42 5440 453534 29
26 23
22 21
20 23 <

15

175

630

55
44 54
36 493430 22
23 15 15
15 1515

15

58
46 56
39 523633 26
25 17
16 17
16 20 <

<

60
47 6044 524037 33
28 20
24 18
23 2717

18

250

900

63
46 59
40 514038 29
33 18
27 17
15 1615

15

65
49 61
43 534240 33
35 29
22 21
20 22 <

18

66
53 6648 564544 38
38 33
27 25
24 3120

21

40

144

33
23 29
28 232115 17
15 15 15
15 1715

15

51
29 32
29 262315 19<

< 15< 20 <

<

42
25 3331 292719 25
16 19
< <17 23 <

<

160

576

46
40 43
38 333016 16
15 15 15
15 1515

15

50
44 45
41 363421 22<

15
< << < <

15

58
47 4945 413930 31
15 23
< <21 2517

19

280

1008

51
46 45
41 373627 19
21 15 15
15 1515

15

55
49 48
44 403931 25
23 17 <17 19 <

16

58
53 5349 474334 33
25 18
25 <24 2820

23

405

1458

59
51 54
47 464438 32
33 19
28 21
19 1516

20

64
54 56
50 494640 35
35 30
24 24
23 2220

24

64
58 5753 504744 40
39 34
29 27
27 3125

28

60

216

36
23 34
26 202115 18
15 15 15
15 1515

15

42
26 36
28 252415 21<

<

46
34 4031 282715 24<

21
< <19 20 <

<

250

900

47
48 42
37 282717 16
15 15 15
15 1515

15

50
50 45
41 333222 23
15 17
< << 18 <

<

55
51 5046 413929 32
22 20
25 21
23 2619

20

430

1548

52
48 45
42 362933 19
28 15
24 21< 2515

15

56
52 50
46 413636 27
31 27
19 24
18 28 <

16

59
56 5751 464337 34
32 28
27 27
26 3123

25

615

2214

60
53 52
45 443940 31
36 16
33 32
20 3315

16

63
56 56
49 484343 35
39 36
23 34
24 3619

22

66
60 6054 524746 40
42 39
30 36
28 3927

29

100

360

35
31 36
30 281815 15
15 15 15
15 1515

15

41
32 37
30 312215 18<

15
< << < <

<

49
37 3832 352923 26
17 23
< <21 2218

<

410

1476

49
46 46
36 372716 16
15 15 15
15 2515

15

53
49 49
40 413322 23<

18
< 15
16 29 <

<

61
53 5847 494133 34
31 29 30
27 3726

23

720

2592

57
52 47
41 383325 26
21 15 23
17 3415

15

60
55 52
45 433830 31
26 20
22 27
22 3719

20

65
58 6052 514639 37
37 35
31 35
30 4230

27

1025

3690

65
58 54
45 494037 28
34 19
31 29
24 3419

18

67
61 58
49 534441 33
37 34
25 34
28 3825

24

72
65 6556 544847 40
45 42
32 41
31 4533

29

170

612

35
36 35
32 282215 16
15 16
15 15
15 1515

15

41
38 38
34 3226< 21<

21
< <17 < <

<

41
41 4336 373224 27
16 28
< 20
27 2524

<

16
< << 18 <

671

2416

51
50 48
36 342722 15
19 15
18 19
16 2315

17

54
53 51
41 393327 23
24 23 26
23 3019

22

58
56 5650 504534 35
31 30
32 34
31 3832

23

1175

4230

66
58 53
39 432936 17
35 17
30 30
22 3515

16

67
64 56
46 473739 27
37 33
25 34
28 3924

22

69
64 6153 524540 36
38 36
33 39
33 4435

23

1680

6048

72
70 63
54 454242 32
39 23
39 37
29 4124

15

78
74 65
56 504545 36
42 41
28 41
32 4529

28

78
76 6757 574850 39
49 46
33 46
35 5038

28

< indicates values below 15

< indicates values below 15

< indicates values below 15

13

Fan (high pressure) Side Air-regenerated Noise TVZ TVZD


The noise created at the damper is also radiated upstream into
the circular high pressure duct.

LWR

TVZ/TVZD

With the help of the LWR values in the table below, possible
effects in the room can be calculated. Further measures may
be necessary, for example, additional insulation of the circular
ducting and/or greater insulation of the false ceiling.

Room

Air-regenerated
Fan (high pressure)
noise TVZ
sidewithout
air-regenerated
TS secondary
noisesilencer
TVZ
ppstst == 100
100 Pa
Pa

160

200

250

315

400

14

in Hz
f m inf mHz

50
72 2653 184815 46
15 15
46 15
42 1627

19

55
79 32
55 255316 50<

46
< <44 1934

27

56
76 3156 255016 47<

47
< <51 2246

39

60

216

47
81 4474 356518 56
15 15
46 15
44 1533

25

51
84 47
77 376622 58<

49
< <48 2241

33

53
83 4676 416926 63<

57
< 1556 2253

45

105

378

54
86 5082 417425 58
16 15
48 15
46 1539

33

57
87 51
84 437528 61
19 52
< <51 1946

40

58
90 5885 477832 68
20 59
< 1858 2855

49

150

540

56
91 5185 497936 69
23 15
57 15
54 1545

38

59
92 54
86 518042 71
37 33
60 1957 20 51

45

62
95 6089 558438 74
28 20
64 1861 2959

53

2000
1000

54

m3/h

63
63
125
125
250
250
500
500
1000

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

in Hz
f m inf mHz

63
63
125
125
250
250
500
500
1000

in Hz
f m inf mHz

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

L W LinWR
dB
in dB

63
63
125
125
250
250
500
500
1000

L W LinWR
dB
in dB

15

l/s
125

 pstst ==500
500Pa
Pa

L W LinWRdB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppstst == 200
200 Pa
Pa

25

90

50
65 3357 245315 52
15 15
42 15
37 1530

20

53
67 45
61 295617 54<

43
< <40 1935

27

55
66 3759 295420 53<

47
< <49 1943

38

100

360

52
68 5274 396621 54
15 21
42 16
40 1633

28

55
71 53
75 416725 57
15 48
< 1946 21 41

36

56
72 5476 457034 65
26 23
56 2155 2352

47

175

630

55
78 5479 497630 57
23 15
45 15
44 1537

33

58
80 56
80 527733 61
25 17
51 1750 20 45

41

60
85 6081 527737 69
28 20
58 1858 2756

52

250

900

63
87 5980 518538 69
33 27
56 17
52 1646

42

65
88 61
82 538540 71
35 29
60 2157 22 52

48

66
93 6687 568844 75
38 33
63 2561 3160

57

40

144

33
53 2957 235015 48
15 15
42 15
37 1728

18

51
59 32
62 265715 50<

45
< 1541 2035

27

42
60 3357 295319 50
16 52
< <50 2348

41

160

576

46
79 4373 336316 51
15 15
43 15
43 1539

34

50
80 45
74 366421 54<

49
< <48 < 45

41

58
84 4977 416930 63
15 57
< <55 2554

50

280

1008

51
81 4575 377027 53
21 15
45 15
48 1542

41

55
84 48
77 407231 58
23 17
52 <52 19 49

47

58
87 5380 477534 65
25 18
59 <59 2856

55

405

1458

59
89 5478 468038 67
33 28
56 21
56 1548

44

64
90 56
80 498140 69
35 30
61 2459 22 54

50

64
93 5784 508244 73
39 34
64 2763 3163

61

60

216

36
56 3456 205015 44
15 15
41 15
36 1529

22

42
59 36
56 255215 45<

44
< <40 1835

29

46
67 4057 285115 47<

52
< <50 2046

39

250

900

47
83 4271 286217 48
15 15
41 15
41 1535

31

50
84 45
72 336422 52
15 48
< <47 1843

39

55
85 5076 416929 61
22 20
56 2155 2655

50

430

1548

52
81 4565 366033 50
28 24
45 21
45 2538

31

56
84 50
69 416536 55
31 27
51 2450 28 46

41

59
91 5777 467437 64
32 28
58 2758 3158

53

615

2214

60
75 5257 445240 54
36 33
54 32
43 3336

26

63
80 56
64 486043 59
39 36
58 3449 36 45

37

66
95 6080 527546 68
42 39
63 3661 3961

56

100

360

35
48 3653 284815 43
15 15
42 15
39 1528

20

41
63 37
56 315015 45<

45
< <42 < 34

27

49
54 3855 354923 49
17 50
< <49 2245

40

410

1476

49
73 4667 375716 42
15 15
39 15
42 2535

31

53
77 49
70 416022 49<

47
< 1548 2943

39

61
86 5877 496933 64
31 29
58 3056 3755

51

720

2592

57
80 4770 385925 45
21 15
44 23
47 3439

35

60
83 52
74 436430 53
26 20
51 2752 37 47

43

65
87 6078 517139 64
37 35
58 3560 4259

55

1025

3690

65
78 5473 496637 58
34 31
52 29
52 3441

35

67
83 58
77 537041 63
37 34
57 3456 38 49

44

72
92 6582 547447 68
45 42
61 4161 4562

57

170

612

35
62 3554 285015 43
15 15
42 15
40 1531

25

41
69 38
57 3252< 46<

46
< <44 < 38

33

41
64 4354 375224 53
16 53
< 2052 2548

43

671

2416

51
76 4866 345422 42
19 18
43 19
46 2338

39

54
78 51
68 395827 50
24 23
50 2651 30 46

46

58
83 5673 506734 62
31 30
57 3459 3857

55

1175

4230

66
80 5364 435436 42
35 30
45 30
47 3541

36

67
83 56
68 476039 51
37 33
51 3452 39 49

45

69
88 6177 526840 62
38 36
58 3961 4460

58

1680

6048

72
84 6360 455542 56
39 39
56 37
45 4137

28

78
86 65
66 506145 62
42 41
60 4151 45 46

39

78
93 6779 577250 66
49 46
61 4662 5063

60

Acoustic Quick Selection TVA TVAD

System attenuation in dB/oct. acc. to VDI 2081 (taken into account in the quick selection table)
fm in Hz

63

125

250

500

1000

2000

4000

8000

Duct bend attenuation

Room attenuation

End reflection

10

Correction for distribution into the low pressure duct system (taken into account in the quick selection table)
.
V

m3/h

500

1000

1500

2000

2500

3000

4000

5000

6000

l/s

139

278

417

556

695

834

1111

1389

1667

10

11

dB per octave

Correction for the calculation of the case-radiated noise (taken into account in the quick selection table)
Ceiling reduction in dB/oct.

Room attenuation in dB/oct.

Quick selection sound pressure level in dB(A)


 pst = 100 Pa
V

Nominal
size

l/s
125

160

200

250

315

400

 pst = 200 Pa

pst = 500 Pa

Air-regenerated noise Case-radiated noise Air-regenerated noise Case-radiated noise Air-regenerated noise Case-radiated noise

m3/h

TVA
LpA

TVA+TS
LpA1

TVA
LpA2

TVAD
LpA3

TVA
LpA

TVA+TS
LpA1

TVA
LpA2

TVAD
LpA3

TVA
LpA

TVA+TS
LpA1

TVA
LpA2

TVAD
LpA3

15

54

17

16

13

13

19

17

15

13

19

17

21

16

60

216

23

20

24

22

24

21

27

22

27

23

30

25

105

378

25

21

28

26

28

24

31

26

35

30

34

29

150

540

27

27

33

28

36

32

37

32

25

90

15

14

13

13

17

15

14

13

20

18

20

15

100

360

27

23

22

20

29

24

26

20

34

29

30

25

175

630

26

21

27

25

30

25

30

25

37

32

35

29

250

900

26

23

33

28

39

34

39

33

40

144

15

14

14

14

17

15

17

14

20

15

19

15

160

576

21

17

24

21

23

18

26

21

29

20

31

26

280

1008

22

17

27

26

25

19

31

26

30

23

36

31

405

1458

28

26

32

28

32

28

40

36

60

216

15

14

14

13

17

15

14

13

20

15

15

13

250

900

19

16

25

23

22

17

27

23

27

21

32

28

430

1548

19

18

27

26

23

22

31

26

30

25

37

32

615

2214

28

29

33

29

32

30

41

36

100

360

16

15

14

14

17

15

14

14

18

16

21

16

410

1476

25

21

26

25

27

22

29

25

31

25

36

31

720

2592

24

20

32

31

27

24

35

31

33

28

41

36

1025

3690

30

29

39

35

35

31

43

38

170

612

15

14

14

14

18

15

19

14

21

16

28

22

671

2416

17

13

29

28

21

16

33

28

28

23

39

33

1175

4230

22

19

35

34

27

23

39

34

32

27

44

39

1680

6048

34

31

44

40

36

32

47

43

For acoustic data for differential pressure up to 1000 Pa, refer to TROX EASY PRODUCT FINDER

15

Air-regenerated Noise TVA TVAD


without TS secondary silencer

Insertion loss
D e in dB
f m in Hz
63

125

250

500

1000

2000

4000

8000

Type / nominal size

TVA 125 to 400 without TS

15

21

27

35

41

39

32

23

TVA 125 to 400 with TS

18

30

35

48

48

46

40

33

Air-regenerated noise TVZ


TVA without TS secondary silencer
ppstst == 100
100 Pa
Pa

160

200

250

315

400

17

55
51 32
39 25 3016 17<

<<

<< 19 <

20

56
54 3139 252716 <<

<

<< 22 <

19

60

216

47
49 4447 35 3318 15
15 15
15 15
15 1515

15

51
56 47
48 37 3522 18<

<<

<< 22 <

<

53
54 4650 413926 25<

17
< 15< 22 <

21

105

378

54
51 5048 41 3825 21
16 15
15 15
15 1515

16

57
57 51
51 43 4128 25
19 16
< << 19 <

20

58
56 5858 474832 31
20 21
< 18
16 2816

25

150

540

51 49 36 23 15
15 15
56

59
59 54
49 51 3942 28
37 33
25 19
18 20 <

22

62
60 6059 554938 36
28 20
26 18
21 2920

30

2000
1000

50
50 2635 18 2615 15
15 15
15 15
15 1615

63
63
125
125
250
250
500
500
1000

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

in Hz
f m inf mHz
63
63
125
125
250
250
500
500
1000

in Hz
f m inf mHz
2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

in Hz
f m inf mHz

63
63
125
125
250
250
500
500
1000

L W in
L WdB
in dB

54

m3/h

25

90

43 3329 24 2415 15
15 15
15 1515
50
15 15

15

53
42 45
30 29 2817 17<

<<

<< 19 <

18

55
57 3738 292620 <<

<< 1916

18

100

360

42 5251 39 3821 21
15 16
15 1615
52
15 21

15

55
43 53
53 41 4125 26
15

<< 19< 21 <

18

56
45 5457 454734 33
26 23
18 21< 2315

22

175

630

43 5450 49 4130 22
15 15
15 1515
55
23 15

17

58
45 56
54 52 4533 28
25 17
17 17< 2017

23

60
49 6061 525137 37
28 20
24 18
18 2722

32

250

900

59 51 38 33 27
17 16
63

65
46 61
49 53 4140 31
35 29
26 21
19 2216

21

66
56 6665 565144 42
38 33
30 25
24 3126

37

<

40

144

42 2924 23 1815 15
15 15
15 1715
33
15 15

15

51
48 32
29 26 2315 20<

<< 15< 20 <

17

42
46 3333 292619 22
16 19
< <17 2318

24

160

576

49 4346 33 2916 19
15 15
15 1515
46
15 15

17

50
51 45
46 36 3221 23<

19
< <18 < 18

23

58
56 4947 413630 29
15 24
< <23 2525

35

280

1008

53 4543 37 3527 23
22 15
21 1519
51
21 15

28

55
55 48
46 40 3831 27
23 17
25 <23 1923

31

58
60 5353 474434 32
25 18
28 <27 2827

37

405

1458

54 46 38 33 28
21 15
59

64
53 56
44 49 3840 35
35 30
35 24
32 2228

32

64
64 5753 504644 39
39 34
37 27
34 3132

38

60

216

42 3424 20 2015 15
15 15
15 1515
36
15 15

17

42
47 36
29 25 2415 19<

15
< << 1815

21

46
46 4031 282815 23<

19
< <18 2019

24

250

900

51 4245 28 2917 21
16 15
16 1516
47
15 15

19

50
53 45
47 33 3322 25
15 20
< <20 1820

24

55
56 5051 414029 31
22 20
24 21
24 2625

29

430

1548

47 4542 36 3033 27
26 21
22 2518
52
28 24

21

56
51 50
47 41 3636 31
31 27
28 24
25 2823

27

59
61 5756 464537 37
32 28
32 27
29 3131

35

615

2214

52 44 40 36 33
32 33
60

63
55 56
45 48 4443 38
39 36
34 34
35 3631

33

66
62 6056 524746 41
42 39
36 36
37 3935

38

100

360

43 3635 28 2515 15
15 15
15 1515
35
15 15

15

41
45 37
37 31 2615 <<

<<

<< < <

17

49
49 3839 352823 15
17

<< 22 <

<

410

1476

56 4654 37 3816 24
20 15
17 2520
49
15 15

31

53
59 49
55 41 4122 29<

25
< 15
21 2925

33

61
65 5858 494533 36
31 29 30
25 3732

33

720

2592

57 4751 38 4125 31
33 23
22 3424
57
21 15

30

60
61 52
55 43 4530 36
26 20
31 27
26 3730

35

65
71 6061 515039 41
37 35 35
29 4240

39

1025

3690

54 49 37 34 31
29 34
65

67
65 58
49 53 4241 43
37 34
40 34
36 3836

38

72
72 6561 545247 47
45 42 41
37 4545

44

170

612

43 3535 28 2215 15
15 15
15 1515
35
15 15

17

41
45 38
37 32 25< 18<

16
< << < 16

22

41
47 4338 373024 23
16 20
< 20
19 2521

26

<

671

2416

52 4844 34 3022 21
20 19
20 2322
51
19 18

27

54
55 51
48 39 3527 26
24 23
24 26
24 3027

32

58
61 5654 504234 31
31 30
29 34
28 3836

38

1175

4230

68 5347 43 3636 30
30 30
29 3527
66
35 30

32

67
70 56
52 47 4139 35
37 33
34 34
33 3934

38

69
70 6158 524740 37
38 36
35 39
34 4443

44

1680

6048

63 45 42 39 39
37 41
72

78
80 65
62 50 4745 44
42 41
41 41
42 4543

47

78
80 6763 575050 45
49 46
42 46
42 5047

49

< indicates values below 15

16

L W in
L WdB
in dB

15

l/s
125

 pstst ==500
500Pa
Pa

L W in
L WdB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppstst == 200
200 Pa
Pa

< indicates values below 15

< indicates values below 15

Air-regenerated Noise TVA TVAD


with TS secondary silencer

Air-regenerated
Air-regenerated
noise
noise
TVZ
TVA
without
with TSTS
secondary
secondary
silencer
silencer
 ppstst == 100
100 Pa
Pa

160

200

250

315

400

LW L
inW1dB
in dB

L W LinW1dB
in dB

in Hz
f m inf mHz

in Hz
f m inf mHz

in Hz
f m in
f mHz

63
63
125
125
250
250
500
500
1000

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

63
63
125
125
250
250
500
500
1000

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

50
46 26
32 182215 15
15 15 1515 1615

15

55
49 3235 25 2516 <<

<<

< < 19 <

<

56
52 3135 252316 <<

<

<< 22 <

<

60

216

47
50 44
43 352818 15
15 15 1515 1515

15

51
54 4744 37 3022 16
<

<<

< < 22 <

<

53
52 4646 413426 16<

< 15< 22 <

15

105

378

54
48 50
44 413325 19
16 15 1515 1515

15

57
55 5147 43 3628 22
19

17
< < < 19 <

<

58
54 5854 474332 22
20 17
< 18< 28 <

18

150

540

51 49 36 23 15
15 15
56

59
57 5445 51 3642 32
37 33
29 1922 20 <

15

62
58 6055 554438 32
28 20
29 18
22 2915

22

2000
1000

54

m3/h

63
63
125
125
250
250
500
500
1000

15

l/s
125

 pstst ==500
500Pa
Pa

LW L
inW1dB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

 ppstst == 200
200 Pa
Pa

25

90

32 33
26 241815 15
50
15 15 1515 1515

15

53
40 4527 29 2217 <<

<<

< < 19 <

<

55
55 3734 292020 <<

<< 19 <

<

100

360

40 52
47 393121 15
15 1615 1615
52
15 21

15

55
41 5349 41 3425 15
15

<< 19< 21 <

<

56
43 5453 454034 19
26 23
< 21< 23 <

17

175

630

41 54
46 493430 18
55
23 15 1515 1515

15

58
43 5650 52 3833 21
25 17
< 17< 20 <

18

60
47 6057 524437 24
28 20
15 18< 27 <

26

250

900

59 51 38 33 27
17 16
63

65
44 6145 53 3640 31
35 29
26 2119 22 <

16

66
54 6661 564444 32
38 33
27 25
20 31 <

31

<

40

144

40 29
21 231515 15
33
15 15 1515 1715

15

51
46 3226 26 1715 <<

<< 15< 20 <

<

42
44 3329 291919 <16

<

<< 23 <

<

160

576

47 43
41 332216 15
46
15 15 1515 1515

15

50
49 4542 36 2521 15
<

<<

<

58
54 4943 412830 19
15

<

<< 25 <

21

280

1008

51 45
39 373027 25
17 1515 1515
51
21 15

16

55
53 4842 40 3231 26
23 17
20 < < 19 <

18

58
58 5349 473734 27
25 18
20 << 28 <

23

405

1458

54 46 38 33 28
21 15
59

64
51 5642 49 3840 38
35 30
33 2427 22 18

19

64
62 5749 504144 38
39 34 27
27 3118

24

60

216

38 34
20 201515 15
36
15 15 1515 1515

15

42
45 3625 25 1615 <<

<<

< < 18 <

15

46
44 4027 281915 <<

<< 20 <

17

250

900

49 42
42 282217 16
47
15 15 1515 1515

15

50
51 4543 33 2522 18
15

<<

< < 18 <

17

55
54 5047 413029 20
22 20
< 21< 26 <

21

430

1548

45 45
38 363233 28
22 2119 2515
52
28 24

15

56
49 5043 41 3536 33
31 27
28 2421 28 <

20

59
59 5752 463837 33
32 28 27
21 3117

27

615

2214

52 44 40 36 33
32 33
60

63
53 5644 48 4343 42
39 36
38 3432 36 24

25

66
60 6052 524346 42
42 39
38 36
32 3925

30

100

360

41 36
31 281715 15
35
15 15 1515 1515

15

41
43 3733 31 1815 <<

<<

<< < <

<

49
47 3835 352023 <17

<< 22 <

<

410

1476

54 46
50 373016 17
49
15 15 1515 2515

25

53
57 4951 41 3322 21
<

16
< 15< 29 15

27

61
63 5854 493633 25
31 29
18 30< 3721

27

720

2592

55 47
47 383625 31
29 2322 3415
57
21 15

24

60
59 5251 43 3930 35
26 20
30 2723 37 20

29

65
69 6057 514239 35
37 35
31 35
24 4229

33

1025

3690

54 49 37 34 31
29 34
65

67
63 5847 53 4541 44
37 34
41 3436 38 29

32

72
70 6557 544747 45
45 42
41 41
36 4535

38

170

612

41 35
31 281515 15
35
15 15 1515 1515

15

41
43 3833 32 17<

<< < <

19

41
45 4334 372124 15
16

< 20< 2515

22

<<

<<

<< < <

<

<

671

2416

50 48
40 342422 17
15 1915 2315
51
19 18

23

54
53 5144 39 2827 20
24 23
15 2615 30 20

28

58
59 5650 503334 23
31 30
20 34
19 3829

34

1175

4230

65 53
43 433436 30
27 3016 3520
66
35 30

28

67
68 5648 47 3839 34
37 33
29 3425 39 27

34

69
68 6154 524040 34
38 36
30 39
25 4436

40

1680

6048

63 45 42 39 39
37 41
72

78
78 6558 50 4545 43
42 41
39 4135 45 36

43

78
78 6759 574650 43
49 46
39 46
35 5040

45

< indicates values below 15

< indicates values below 15

< indicates values below 15

17

Case-radiated Noise TVA

Case-radiated
Air-regenerated
noise
noise
TVATVZ
without
without
additional
TS secondary
acousticsilencer
cladding
ppstst == 100
100 Pa
Pa

160

200

250

315

400

15

55
< 3226 25 1816 <<

<<

<19 19 <

20

56
27 3124 252416 23<

23
< <23 2222

25

60

216

47
29 4440 35 3418 27
15 15
22 15
24 1523

26

51
34 4741 37 3522 30<

26
< <28 2227

30

53
42 4645 413726 32<

29
< 1533 2230

32

105

378

54
37 5043 41 3925 32
16 15
26 15
28 1527

28

57
40 5145 43 4028 35
19

29
< <32 1931

32

58
45 5850 474232 35
20 32
< 1836 2833

34

150

540

51 49 36 23 15
15 15
56

59
45 5448 51 4342 40
37 33
32 1934 20 31

33

62
48 6053 554638 41
28 20
35 1838 2938

37

2000
1000

50
15 2622 18 1515 16
15 15 15
15 1615

63
63
125
125
250
250
500
500
1000

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

in Hz
f m inf mHz
63
63
125
125
250
250
500
500
1000

in Hz
f m inf mHz
2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

in Hz
f m inf mHz

63
63
125
125
250
250
500
500
1000

LW L
inW2dB
in dB

54

m3/h

25

90

17 3324 24 1615 15
15 1515
50
15 15 15

15

53
23 4529 29 2017 15<

<<

<15 19 <

19

55
24 3728 292220 20<

20
< <22 1920

24

100

360

40 5242 39 3121 25
20 16
23 1621
52
15 21

22

55
42 5343 41 3425 28
15

24
< 1927 21 25

27

56
42 5445 453734 31
26 23
29 2132 2330

31

175

630

45 5445 49 3530 30
25 15
27 1525
55
23 15

29

58
47 5647 52 3833 33
25 17
28 1731 20 29

32

60
49 6051 524237 37
28 20
33 1836 2734

36

250

900

59 51 38 33 27
17 16
63

65
48 6150 53 4240 38
35 29
32 2133 22 32

34

66
55 6656 564744 42
38 33
36 2539 3139

40

40

144

26 2931 23 2215 15
15 1715
33
15 15 15

15

51
32 3234 26 2415 18<

17
< 1519 2016

20

42
22 3331 292519 22
16 20
< <21 2319

23

160

576

46 4345 33 3016 23
21 15
24 1521
46
15 15

19

50
47 4546 36 3421 28<

26
< <28 < 26

26

58
51 4948 413930 33
15 30
< <32 2532

34

280

1008

45 4544 37 3627 28
25 15
29 1526
51
21 15

29

55
48 4848 40 3931 32
23 17
29 <32 19 31

33

58
55 5352 474534 37
25 18
34 <36 2838

38

405

1458

54 46 38 33 28
21 15
59

64
48 5646 49 4240 39
35 30
32 2433 22 31

32

64
61 5753 504844 44
39 34
38 2739 3144

43

60

216

23 3432 20 1515 15
15 1515
36
15 15 15

15

42
25 3632 25 <15 <<

<<

< < 18 <

<

46
32 4033 28 <15 <<

18
< <18 20 <

<

250

900

48 4247 28 2917 21
< 15
26 1519
47
15 15

26

50
50 4548 33 3322 27
15

16
< <30 1825

30

55
56 5052 413929 34
22 20
31 2134 2633

33

430

1548

46 4545 36 2933 25
26 21
32 2524
52
28 24

26

56
50 5048 41 3836 33
31 27
31 2434 28 29

31

59
59 5755 464537 41
32 28
37 2738 3139

37

615

2214

52 44 40 36 33
32 33
60

63
50 5645 48 4743 40
39 36
32 3432 36 26

29

66
59 6056 525046 44
42 39
41 3641 3943

40

100

360

27 3631 28 1615 15
16 1515
35
15 15 15

16

41
28 3731 31 1515 16<

15
< <15 < <

15

49
39 3834 351923 18
17 24
< <25 2220

20

410

1476

52 4642 37 2916 24
24 15
29 2523
49
15 15

27

53
54 4944 41 3422 30<

29
< 1533 2928

31

61
55 5848 494333 38
31 29
35 3038 3738

37

720

2592

58 4748 38 3725 31
31 23
34 3430
57
21 15

33

60
60 5250 43 4230 36
26 20
35 2738 37 34

37

65
60 6053 514839 42
37 35
40 3542 4244

42

1025

3690

54 49 37 34 31
29 34
65

67
64 5854 53 4841 43
37 34
38 3440 38 37

39

72
62 6555 545247 46
45 42
43 4144 4545

44

170

612

29 3528 28 1515 15
15 1515
35
15 15 15

15

41
32 3830 32 20< 20<

22
< <22 < 19

18

41
44 4335 373024 26
16 28
< 2032 2529

28

671

2416

47 4837 34 2922 26
28 19
34 2331
51
19 18

29

54
50 5142 39 3627 33
24 23
33 2638 30 36

34

58
56 5649 504634 39
31 30
37 3440 3843

40

1175

4230

60 5346 43 4236 34
33 30
37 3536
66
35 30

38

67
63 5650 47 4739 40
37 33
38 3441 39 41

42

69
64 6152 524940 44
38 36
43 3945 4449

47

1680

6048

63 45 42 39 39
37 41
72

78
71 6558 50 5045 47
42 41
44 4142 45 43

46

78
72 6758 575350 48
49 46 4647 5051

50

< indicates values below 15

18

LW L
inW2dB
in dB

15

l/s
125

 pstst ==500
500Pa
Pa

LW L
inW2dB
in dB
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppstst == 200
200 Pa
Pa

< indicates values below 15

< indicates values below 15

Case-radiated Noise TVAD

Case-radiated
Air-regenerated
noise
noise
TVAD
TVZwith
without
additional
TS secondary
acousticsilencer
cladding
ppst==200
200Pa
Pa

st

160

200

250

315

400

f m in Hz

54

50
< 2619 18 <15 15
15 15
15 1515 16 15

15

55
< 3220 25 <16 <<

<<

< < 19 <

15

56
24 3118 251816 16<

19
< <18 2217

20

60

216

47
31 4435 352918 23
15 15
22 1523 15 22

25

51
31 4735 37 2922 23<

22
< <23 2222

25

53
39 4639 413126 25<

25
< 15
28 2225

27

105

378

54
38 5040 413525 29
16 15
26 1527 15 26

27

57
37 5139 43 3428 28
19 25
< <27 1926

27

58
42 5844 473632 28
20 28
< 18
31 2828

29

150

540

56
51 49 36 23
15
15 15

59
42 5442 51 3742 33
37 33
28 1929 2026

28

62
45 6047 554038 34
28 20
31 18
33 2933

32

m3/h

63
63
125
125
250
250
500
500
1000

2000
1000

f m in Hz

63
63
125
125
250
250
500
500
1000

f m in Hz

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

LLW3
in dB
dB
W in

63
63
125
125
250
250
500
500
1000

LLW3
in dB
dB
W in

15

l/s
125

st

LLW3
in dB
dB
W in
2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppst==500
500Pa
Pa

st

4000
2000
8000
4000
L in dB(A)
8000
NR

ppst==100
100Pa
Pa

25

90

50
21 3323 241515 15
15 15
15 1515 15 15

15

53
21 4523 29 1517 <<

< < 19 <

<

55
22 3722 291720 <<

16
< <17 1915

19

100

360

52
40 5237 392921 22
15 21
20 1622 16 20

22

55
40 5337 41 2925 22
15 20
< 1922 2120

22

56
40 5439 453234 25
26 23
25 21
27 2325

26

175

630

55
45 5441 493330 27
23 15
24 1526 15 24

27

58
45 5641 52 3333 27
25 17
24 1726 2024

27

60
47 6045 523737 31
28 20
29 18
31 2729

31

250

900

63
59 51 38 33
27
17 16

65
46 6144 53 3740 32
35 29
28 2128 2227

29

66
53 6650 564244 36
38 33
32 25
34 3134

35

<<

40

144

33
30 2929 232015 15
15 15
15 1515 17 15

15

51
30 3229 26 2015 <<

<< 15< 20 <

15

42
20 3326 292119 17
16 16
< <16 23 <

18

160

576

46
45 4341 332916 22
15 15
21 1522 15 20

20

50
45 4541 36 3021 23<

22
< <23 < 21

21

58
49 4943 413530 28
15 26
< <27 2527

29

280

1008

51
46 4543 373527 27
21 15
25 1527 15 26

28

55
46 4843 40 3531 27
23 17
25 <27 1926

28

58
53 5347 474134 32
25 18
30 <31 2833

33

405

1458

59
54 46 38 33
28
21 15

64
46 5641 49 3840 34
35 30
28 2428 2226

27

64
59 5748 504444 39
39 34 27
34 3139

38

60

216

36
22 3426 201515 15
15 15
15 1515 15 15

15

42
23 3627 25 <15 <<

<<

< < 18 <

<

46
38 4028 28 < 15 <<

<< 20 <

<

250

900

47
48 4243 282817 21
15 15
< 1524 15 19

25

50
48 4543 33 2922 22
15

<<

<25 1820

25

55
54 5047 413529 29
22 20
27 21
29 2628

28

430

1548

52
48 4544 363233 26
28 24
27 2130 25 25

27

56
48 5043 41 3436 28
31 27
27 2429 2824

26

59
57 5750 464137 36
32 28
33 27
33 3134

32

615

2214

60
52 44 40 36
33
32 33

63
48 5640 48 4343 35
39 36
28 3427 3621

24

66
57 6051 524646 39
42 39
37 36
36 3938

35

100

360

35
28 3627 281515 15
15 15
15 1515 15 15

15

41
27 3727 31 <15 <<

<<

<< < <

<

49
38 3830 351523 <17 20
< <19 22 <

15

410

1476

49
53 4640 373016 25
15 15
25 1527 25 22

26

53
53 4940 41 3022 25<

25
< 1527 2922

26

61
54 5844 493933 33
31 29
31 30
32 3732

32

720

2592

57
59 4746 383825 31
21 15
31 2332 34 28

32

60
59 5246 43 3830 31
26 20
31 2732 3728

32

65
59 6049 514439 37
37 35
36 35
36 4238

37

1025

3690

65
54 49 37 34
31
29 34

67
63 5850 53 4441 38
37 34
34 3434 3831

34

72
61 6551 544847 41
45 42
39 41
38 4539

39

170

612

35
31 3526 281615 15
15 15
18 1515 15 15

15

41
31 3826 32 16< 15<

18
< <15 < <

<

41
43 4331 372624 21
16 24
< 20
25 2523

23

<

671

2416

51
48 4837 343122 27
19 18
29 1931 23 30

28

54
49 5138 39 3227 28
24 23
29 2631 3030

29

58
55 5645 504234 34
31 30
33 34
33 3837

35

1175

4230

66
61 5345 434236 34
35 30
33 3034 35 35

36

67
62 5646 47 4339 35
37 33
34 3434 3935

37

69
63 6148 524540 39
38 36
39 39
38 4443

42

1680

6048

72
63 45 42 39
39
37 41

78
70 6554 50 4645 42
42 41
40 4135 4537

41

78
71 6754 574950 43
49 46
42 46
40 5045

45

< indicates values below 15

< indicates values below 15

< indicates values below 15

19

Fan (high pressure) Side Air-regenerated Noise TVA TVAD


The noise created at the damper is also radiated upstream into
the circular high pressure duct.
LWR

TVA/TVAD

With the help of the LWR values in the table below, possible
effects in the room can be calculated. Further measures may be
necessary, for example, additional insulation on the circular
ducting and/or greater insulation of the false ceiling.

Room

Air-regenerated
Fan (high pressure)
noise TVZ
sidewithout
air-regenerated
TS secondary
noisesilencer
TVA
ppstst == 100
100 Pa
Pa

160

200

250

315

400

20

in Hz
f m inf mHz

in Hz
f m inf mHz

13

55
76 3256 254716 36<

29
< <30 1927

22

56
75 3150 254716 38< 33
<

<33 2236

34

60

216

47
84 4476 35 6118 49
15 15
44 15
44 1540

32

51
86 4777 376522 53<

48
< <48 2245

38

53
90 4679 416926 59< 54
< 15
53 2252

47

105

378

54
88 5078 41 7325 55
16 15
48 15
48 1547

38

57
90 5180 437528 59
19 53
< <52 1952

45

58
94 5885 477732 6520 60
< 18
58 2860

55

150

540

56
51 49 36 23 15
15 15

59
87 5480 517342 64
37 33
55 1950 2053

44

62
97 6089 558138 7228 66
20 18
60 2965

59

4000
2000
8000
4000
L in dB(A)
8000
NR

50
74 2648 18 4515 34
15 15
24 15
25 1621

2000
1000

54

m3/h

63
63
125
125
250
250
500
500
1000

63
63
125
125
250
250
500
500
1000

in Hz
f m inf mHz

2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

L W LinWR
dB
in dB

63
63
125
125
250
250
500
500
1000

L W LinWR
dBin dB

15

l/s
125

 pstst ==500
500Pa
Pa

L W LinWR
dB
in dB
2000
1000
4000
2000
8000
4000
L in dB(A)
8000
NR

Nominal
size

ppstst == 200
200 Pa
Pa

25

90

50
60 3343 24 4415 31
15 15
22 15
19 1514

10

53
66 4548 294817 36<

27
< <25 1922

19

55
72 3754 295120 40< 33
<

<32 1931

29

100

360

52
73 5275 39 6221 51
15 21
42 16
51 1648

42

55
78 5377 416625 56
15 48
< 1954 2152

46

56
89 5480 457234 6426 55
23 21
57 2358

54

175

630

55
82 5475 49 6930 54
23 15
47 15
53 1555

46

58
86 5679 527333 59
25 17
53 1756 2059

52

60
93 6084 527737 6828 59
20 18
61 2765

61

250

900

63
59 51 38 33 27
17 16

65
77 6176 537040 61
35 29
58 2154 2256

48

66
98 6688 567944 7338 65
33 25
62 3168

66

40

144

33
57 2959 23 4815 40
15 15
30 15
22 1716

51
62 3260 265015 43<

35
< 1529 2024

18

42
78 3363 295519 4916 44
<

<39 2336

34

160

576

46
80 4369 33 5616 51
15 15
44 15
52 1548

44

50
81 4572 366021 54<

49
< <54 < 50

46

58
84 4978 416630 6115 58
<

<59 2554

51

280

1008

51
83 4571 37 5927 55
21 15
46 15
58 1555

50

55
85 4875 406431 59
23 17
52 <60 1958

54

58
89 5381 477034 6525 60
18 <63 2863

61

405

1458

59
54 46 38 33 28
21 15

64
84 5674 496840 64
35 30
57 2457 2255

51

64
97 5783 507444 7139 64
34 27
66 3168

68

60

216

36
68 3449 20 4015 34
15 15
34 15
30 1524

14

42
74 3656 254715 40<

39
< <37 1830

23

46
72 4051 284415 38< 35
<

<34 2034

33

250

900

47
82 4273 28 5617 51
15 15
49 15
57 1548

46

50
84 4574 336022 55
15 53
< <59 1853

50

55
86 5077 416629 6222 57
20 21
62 2661

58

430

1548

52
84 4569 36 5833 55
28 24
49 21
60 2552

49

56
87 5074 416436 61
31 27
55 2463 2859

56

59
92 5781 467437 6832 62
28 27
66 3169

65

615

2214

60
52 44 40 36 33
32 33

63
89 5676 486943 68
39 36
61 3465 3662

59

66
97 6084 527546 7442 66
39 36
68 3974

70

100

360

35
50 3655 28 4615 41
15 15
37 15
35 1532

23

41
58 3756 314715 42<

43
< <42 < 36

30

49
57 3857 354823 4317 40
<

<38 2238

36

410

1476

49
80 4666 37 5016 51
15 15
52 15
59 2551

48

53
82 4970 415822 56<

56
< 1561 2956

53

61
86 5876 495733 6431 60
29 30
63 3765

61

720

2592

57
80 4768 38 5725 56
21 15
51 23
64 3456

51

60
84 5273 436330 62
26 20
57 2766 3762

58

65
91 6081 517139 6937 64
35 35
68 4274

68

1025

3690

65
54 49 37 34 31
29 34

67
88 5875 536741 71
37 34
61 3468 3865

61

72
96 6583 547447 7445 67
42 41
70 4579

72

170

612

35
66 3554 28 4715 39
15 15
37 15
35 1529

22

41
71 3855 3249< 42<

41
< <39 < 35

30

41
69 4357 375324 4716 44
< 20
42 2542

40

671

2416

51
79 4860 34 5622 51
19 18
52 19
57 2358

54

54
82 5165 396127 56
24 23
56 2659 3061

58

58
85 5672 506834 6331 60
30 34
63 3866

64

1175

4230

66
85 5364 43 6136 55
35 30
53 30
60 3563

58

67
88 5669 476739 61
37 33
58 3463 3967

64

69
92 6177 527440 6838 65
36 39
68 4473

73

1680

6048

72
63 45 42 39 39
37 41

78
96 6575 507345 39
42 41
63 4167 4571

70

78
98 6780 577850 7349 68
46 46
69 5076

77

Control code BC0 Compact flow rate controller


Flow rate ranges
in l/s

in m/h

min
min unit

max
up to

from

up to Nom

Nominal size
125
160
200
250
315
400
1)

max

min

min unit

up to

from

up to Nom

TVZ TVA
15
25
40
60
105
170

150
250
405
615
1025
1680

45
75
120
185
310
505

150
250
405
615
1025
1680

54
90
144
216
378
612

540
900
1458
2214
3690
6048

162
270
432
666
1116
1818

540
900
1458
2214
3690
6048

Vmin = 0 is also possible

Wiring

The 24 V supply voltage must be derived from a safety transformer


to (EN 60742). It is important to ensure that the common neutral or
ground wire is used is not connected to any other wiring.

VAV Compact

Terminal allocation

U5 / MP

VAV Compact

Nomenclature

Ground

Supply voltage 24 V

Control signal input (0/2 to 10 V DC)

MP

MP bus

U5

Actual value signal output (output signal is


volumetric flow 0-10 V)

VAV Compact

Shaft clamp

Gear release button

Rotation angle limiter

Tube connection for transducer

Indicator lights

Connection for adjustment tool

Connecting cable

Technical data
Supply voltage

24 V AC 20 %, 50/60 Hz. 24 V DC

Power rating

max. 4 VA (for AC voltage)


max. 2 W (for DC voltage)

IEC protection
class

III (Safe voltage)

Control signal

0 to 10 V DC, Ri >100 k

Protection level

IP 54

Flow rate actual value signal

0 to 10 V DC linear, max. 0,5 mA

EMC

CE marking according to 89/336/EWG

21

Room temperature controller


System solution for decentralised room temperature control
The individual room control, together with the air terminal unit
and its control components, form a functional package for
optimum control of the individual room temperature with the
lowest energy use.
Two unit options are available with various output sequences
suitable for a range of applications including air-water systems.

Functions
Comfort mode
The comfort setpoint values (heating/cooling) are maintained
All control functions are enabled.
Power cut-off
The controller cuts off the control functions and only allows
protection modes i.e. for frost. This function is usually active
when a window is open.
Standby
The room is maintained in a state from which the comfort
setpoint values can be quickly reached again Thus, the cooling
setpoint value is raised and the heating setpoint value lowered.
Change over
A function required when the air conditioning system is
operated with warm or cold air, the direction of control is
reversed depending on the time of year.

Control diagram with heating and cooling modes

Volume flow

Heating valve

Room temperature controller

Heating

Cooling

CR24-B2
Individual room controller with two outputs for VAV
systems and hot-water heating (reheat unit or radiators).
CR24-B3
Individual room controller with three outputs for VAV
systems and additional heating and cooling functions.

22

Electric Heater Data


Electric Heaters 1)
The electric heater is available as an integral unit complete with
controls including fuses and interlocks.
The integral air heater has elements designed for black heat
operation and consists of 80 / 20 nickel chrome wire in a
stainless steel tube (grade 312) filled with magnesium oxide.
An automatic reset high temperature cut out is fitted and a
brass earth stud included. The heater is manufactured to British
Standards /Codes as applicable and fully factory tested. A low
air pressure switch is fitted. This switch will disconnect the
heater if the airflow reduces below a pre-set minimum.
The heater elements are wired back into the control enclosure,
including the earth where heater fuses are supplied.
Control of the heater can be arranged for stepless control by
thyristors. Control type should be selected to suit the
temperature controller used and the degree of accuracy
required on temperature control.
1)

Electric heaters are available on request. Full details required


such as kW, Voltage, Phase should be stated.

Standard Electric Heaters


Standard electric heaters
Volts

Phase

125

230

160

230

85 l/s

200

230

140 l/s

250

230

210 l/s

315

230

375 l/s

400

230

580 l/s

Size

Volts

Phase

160

400

85 l/s

200

400

140 l/s

250

400

210 l/s

315

400

375 l/s

400

400

580 l/s

Note

1)
2)

1kW

2kW

3kW

4kW

Minimum
Airflow

Size

5kW

50 l/s

3kW

4.5kW

6kW

7.5kW

9kW

All the above heaters are one step for use with a thyristor.
Heaters should be sized such that the maximum air off temperature is approx 30 C

23

Reheat Coil Selection


1

Mean water pressure drop for


sizes 125 to 400

Water Pressure Drop Calculation


One, two or four row reheat coil

m
w

m
wK = in kg/s
K

For 1 circuit
0,1
0.1
kg/s

V t
m w = in kg/s
t w 3,5 10 3

V in l/s

0.06
0,06

Number of Rows

0,04
0.04
m wK

Size
Size
0,02
0.02

K
For circuits > 1
0.8 1
0,8

4
pv

10

Number of rows

125125 160160

1RR

2RR

1RR
K
2RR
4RR
4RR

1
1
1

20 kPa 40

Selection diagram

Number of rows

Size

te
See page 6 for Nomenclature

24

1
2
2

1
2
2

200
200
2
4
4

2
4
4

260
250
2
4
4

2
4
4

315
315

400
400

2
5
5
5

4
7
9
9

Order Details TVZ TS


supply box

Specification Text
VAV terminal boxes for variable volume systems, for supply air, in 6
nominal sizes.
Ready-to-use box consisting of mechanical parts and electronic control
components. The boxes contain an averaging differential pressure sensor
for volume flow measurement, a control damper and an integral silencer.
Special characteristics:
Integral sound attenuator with at least 26 dB insertion loss at 250 Hz
Factory set up or programming of flow rate. This includes
aerodynamic function test of each box using a dedicated test rig.
Differential pressure sensor with 3 mm measuring holes and so insensitive
to dirt.
Control closed damper blade airtightness to EN 1751, class 4 (nominal
size 125, class 3). Position of the control damper blade visible from the
outside on the shaft extension.
Baffle plates are fitted behind the control damper for optimum acoustic
and aerodynamic qualities. Casing with acoustic and thermal lining.
Variable flow rate control with electronic controller for the connection
of an external control signal, actual value signal for incorporation in the
central control in a building (BMS).
24 VAC power supply DC
Signal voltage: 0 to 10 VDC
Dynamic differential pressure measurement
On site measurement and resetting of minimum and maximum air flow
rates possible.
The actual value signal is referred to the nominal flow rate so simplifying
any subsequent adjustment to volume flow.
Flow rate range (depending on manufacturer and type of controller)
approx. 10 % to 100% of nominal flow rate.

Differential pressure range 20 to 1500 Pa


Circular spigot on the fan (high pressure) side, this includes a groove
for the use of a lip seal, suitable for circular connecting ducts to EN 1506
or EN 13180. Room (low pressure) side suitable for attachment of
connecting flanges.
Casing air leakage complies with EN 1751, class A with VDI 2083, clean
room class 3 and US Federal Standard 209E.
Materials:
Lining in the sound attenuator section and in the control damper
chamber from mineral wool conforming to DIN 4102, fire rating
class A2. See page 5.
Mineral wool faced with fibreglass as protection against erosion
suitable for air velocities up to 20 m/s, inert to fungal and bacterial
growth.
Control damper blade with thermoplastic elastomer seal, sensor
tubes in aluminium, plastic plain bearings.
Options:
Additional acoustic cladding for the reduction of case-radiated
noise with structure-borne noise isolation, insulation of minimum
5 dB, consists of 40 mm mineral wool and outer cover consisting of
1 mm galvanised sheet steel, non-retrofittable.
Reheat Coil, or electric heater battery. See pages 5 and 23
respectively.
TS secondary silencer, for the reduction of air-regenerated noise,
entire insertion loss of the basic unit with TS at least 32 dB at
250 Hz. Lining of mineral wool conforming to DIN 4102, fire rating
class A2.
Mineral wool faced with fibreglass as protection against erosion,
suitable for air velocities up to 20 m/s, inert to fungal and bacterial
growth.

Order Code TVZ


TVZ - V2

-- --

125

00

BC0

E0 - 15 - 150 /

Type
Supply box
TVZ
With additional
acoustic cladding TVZD

Control diagram
Refer to TROX
Volume flow control
State min and max in l/s

Version
V2
Reheat Coil
With 1 row
With 2 rows
With 4 rows (2+2)
Electric (refer to Trox)
or no entry

1
2
4
E
-

Size
125
160
200
250
315
400

Operating mode
E0 - BMS 0 - 10v dc control signal

Controller
Refer to TROX for further control options.
See online design program or
TROX EASY PRODUCT FINDER

Lining
Perforated plate over mineral wool
LB
Additional sealant to give Class B leakage SB
Perforated plate and additional sealant
LS
or no entry for standard construction
without perforated sheet metal cover

Order Details TS

00B450A

TS - V2 -

Type
TS silencer
Version
V2
Lining
Perforated plate over mineral wool
LB
Additional sealant to give Class B leakage SB
Perforated plate and additional sealant
LS
or no entry for standard construction
without perforated sheet metal cover

Additions
00 Standard
D1 Lip seal
/

125
Size
125
160
200
250
315
400

Order Example TVZ

Order Example TS

Make:
Type:

Make:
Type:

TROX
TVZ-V2/125/00/BC0/E0-15-150/00B450

TROX
TS-V2/125

25

Order Details TVA TS


extract box

Specification Text
VAV terminal boxes for variable volume systems, for extract air, in 6
nominal sizes.
Ready-to-use box consisting of mechanical parts and electronic control
components. The boxes contain an averaging differential pressure sensor
for volume flow measurement, a control damper and an integral silencer.
Special characteristics:
Integral sound attenuator with at least 26 dB insertion loss at 250 Hz
Factory set up or programming of flow rate. This includes aerodynamic
function test of each box using a dedicated test rig.
Differential pressure sensor with 3 mm measuring holes and so insensitive
to dirt.
Control closed damper blade airtightness to EN 1751, class 4 (nominal
size 125, class 3). Position of the control damper blade visible from the
outside on the shaft extension.
Baffle plates are fitted behind the control damper for optimum acoustic
and aerodynamic qualities. Casing with acoustic and thermal lining.
Variable flow rate control with electronic controller for the connection of an
external control signal, actual value signal for incorporation in the central
control in a building (BMS).
24 VAC power supply
Signal voltage: 0 to 10 VDC
Dynamic differential pressure measurement
On site measurement and resetting of minimum and maximum air flow
rates possible.
The actual value signal is referred to the nominal flow rate so simplifying
any subsequent adjustment to volume flow.

Flow rate range (depending on manufacturer and type of controller)


approx. 10 % to 100% of nominal flow rate.
Differential pressure range 20 to 1500 Pa
Circular spigot on the fan (high pressure) side, this includes a groove for
the use of a lip seal, suitable for circular connecting ducts to EN 1506 or
EN 13180. Room (low pressure) side suitable for attachment of connecting
flanges. Casing air leakage complies with EN 1751, class A.
Materials:
Lining in the sound attenuator section and in the control damper chamber
from mineral wool conforming to EN 4102, fire rating class A2.
Mineral wool faced with fibreglass as protection against erosion suitable
for air velocities up to 20 m/s, inert to fungal and bacterial growth.
Control damper blade with thermoplastic elastomer seal, sensor tubes in
aluminium, plastic plain bearings.
Options:
Additional acoustic cladding for the reduction of case-radiated noise
with structure-borne noise isolation, insulation of minimum 5 dB, consists
of 40 mm mineral wool and outer cover consisting of 1 mm galvanised
sheet steel, non-retrofittable.
TS secondary silencer, for the reduction of air-regenerated noise, entire
insertion loss of the basic unit with TS at least 32 dB at 250 Hz. Lining of
mineral wool conforming to EN 4102, fire rating class A2.
Mineral wool faced with fibreglass as protection against erosion, suitable
for air velocities up to 20 m/s, inert to fungal and bacterial growth.

Order Code TVA


TVA- V2 -Type
Extract box
TVA
With additional
acoustic cladding TVAD
Version
V2

125

00

Subject to change without notice All rights reserved TROX UK Ltd (01/2012)

TS - V2 --

Type
TS silencer
Version
V2
Lining
Perforated plate over mineral wool
LB
Additional sealant to give Class B leakage SB
Perforated plate and additional sealant
LS
or no entry for standard construction
without perforated sheet metal cover

26

BC0

E0 - 15 - 150 /

Volume flow control


State min and max in l/s
Operating mode
E0 - BMS 0 - 10v dc control signal

Controller
Refer to TROX for further control options.
See online design program or
TROX EASY PRODUCT FINDER
Additions
00 Standard
D1 Lip seal

125
Size
125
160
200
250
315
400

Order Example TVA

Order Example TS

Make:
Type:

Make:
Type:

TROX
TVA-V2/125/00/BC0/E0-15-150/00B450

00B450B
Control diagram
Refer to TROX

Size
125
160
200
250
315
400

Lining
Perforated plate over mineral wool
LB
Additional sealant to give Class B leakage SB
Perforated plate and additional sealant
LS
or no entry for standard construction
without perforated sheet metal cover

Order Details TS

TROX
TS-V2/125