voltage waveform, with the use of amplitude modulation, low frequency voltage harmonics are perfectly eliminated, generating almost perfect sinusoidal waveforms, with a Multilevel inverters can operate not only with PWM but also with amplitude modulation (AM) ,improving significantly the quality of the output THD lower than 5%. Another important characteristic is that each converter operated at a low switching frequency, reducing the semiconductor stresses and therefore reducing the switching losses. The selective harmonic elimination (SHE) inverter can evidently reduce the harmonic content of output voltage in power electronic device consisting of inverters, and improve the dynamic performance of variable voltage variable frequency. Therefore, the electric devices can obtain the sine wave of perfect quality [1]. Selective harmonic elimination pulse width modulation (SHEPWM) is a well-known switching strategy is eliminating low order harmonics [3].Basically, harmonic equations are nonlinear and solving them is a major problem for researchers. The elimination of harmonics in a multilevel inverter has been implemented by using fundamental modulation switching. This method eliminates harmonics by generating negative harmonics with switching angles calculated for selective harmonic elimination method [4]. A reduction in the eliminated harmonics results in an increase in the degrees of freedom. As a result, the lower order harmonics are eliminated in more operating points [5]. The power conversion strategy called multilevel inversion decreases the total harmonic distortion (THD) by obtaining the output voltage in steps and bringing the output closer to a sine wave [6]. Producing an approximate sinusoidal voltage from multiple levels of dc voltages, normally obtained from capacitor voltage sources is the common objective of multilevel inverters [7]. Flexible ac transmission systems, renewable energy sources, uninterruptible power supplies and active power filters are some power electronics applications in which multilevel inverters are important [8]. Non-linear loads like adjustable speed drives; electronically ballasted lighting and the power supplies of the electrical equipment used in modern offices cause current harmonics in modern electrical distribution systems [9]. Diverse techniques have been identified to decrease the problem of harmonics. Some examples are: 1) Specific Harmonic Elimination (SHE} which is used for eradication of unwanted lower order harmonics and control of fundamental voltage in a square wave 2) Harmonic elimination pulse width modulation (HEPWM) method that has a number of benefits compared to traditional sinusoidal PWM (SPWM) for Voltage Source Inverters (VSI) [8-9].By selecting proper switching angles, they have achieved harmonic reduction. The DC link voltage has been kept constant and the modulation index of the inverter has been varied for controlling the multilevel inverter.