Eagle-100 Series
Eagle-200 Series
OL
TR
CC
EA
ES
ST
SY
EM
S,
.
INC
ON
SC
GL
BY
EA
TABLE OF CONTENTS
SWING GATE OPERATOR SPECIFICATIONS
SAFETY
METHODS OF INSTALLATION
Standard Installation
Compact Installation
Easy Release Alignment
Gate Arm Installation
Reverse, Phantom (Shadow) and Exit In-Ground Loop Installation
Secondary Entrapment Protection
3
4
4
5
5
6
6
6
7
7
8
8
9
9
9
10
10
11
11
11
12
12
12
13
13
14
15
16
17
18
19
19
19
19
20
20
21
21
21
22
22
23
23
24
24
24
25
25
26
27
28
29
30
31
Motor Power
Max Length Max Weight Control Board Operation Battery Back-Up & Cycles
1/2 HP - 120 VAC - 5.7 amp
18 ft
600 lbs
Diamond
Continuous Power I (Optional) - 100
Input Power: 120/240 VAC (1 Phase)
18 ft
600 lbs
Diamond DC Continuous
Built-in - 100
Operator Power: 1/2 HP - 24 VDC
NOTE: Eagle-100
can handle
lite-commercial
duty as well as
residential.
Eagle-100 Series
Specifications
28
18.5
16
Motor(s) Power
Max Length Max Weight Control Board
750 lbs
1/2 HP - 120 VAC - 5.7 amp
Diamond
20 ft
1000 lbs
1 HP - 120 VAC - 10.5 amp
Diamond
20 ft
750 lbs
(2) 1/2 HP - 120 VAC - 5.7 amp
Diamond
20 ft
Input Power: 120/240 VAC (1 Phase)
Eagle-200-DC
800 lbs
Diamond DC
20 ft
Operator Power: 1/2 HP - 24 VDC
Input Power: 120/240 VAC (1 Phase)
Eagle-200-DC-HD
1000 lbs
Diamond DC
20 ft
Operator Power: 3/4 HP - 24 VDC
Operation
Continuous
Continuous
Continuous
Continuous
Built-in - 100
Continuous
Built-in - 100
Eagle-200 Series
29.25
22
2
17.5
SAFETY
Requirements for UL 325 Compliant Installation
1. Install the gate operator only when:
a) The operator is appropriate for the construction of the gate and the usage class of the gate.
b) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the
ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion
of the adjacent fence that the gate covers in the open position.
c) All exposed pinch points are eliminated or guarded, and
d) Guarding is supplied for exposed rollers.
2. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The
pedestrian access opening shall be designed to promote pedestrian usage. Locate the pedestrian gate such that persons will not come in
contact with the vehicular gate during the entire path of travel of the vehicular gate.
3. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
UL 325 Requirements
4. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the
operator clutch or pressure relief valve to compensate for a damaged gate.
5. For gate operators utilizing Type D protection:
a) The gate operator controls must be placed so that the user has full view of the gate area when the gate is not moving.
b) The placard provided marked in letters at least 1/4 in. (6.4-mm) high with the word WARNING and the following statement or the
equivalent: Moving Gate Has the Potential of Inflicting Injury or Death Do Not Start Gate Unless Path is Clear shall be placed adjacent
to the controls,
c) An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and
d) No other activation device shall be connected.
6. Controls intended for user activation must be located at least six feet (6) away from any moving part of the gate and where the user is
prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a
security feature to prevent unauthorized use.
7. The Stop and /or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to
start.
8. A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
9. For gate operators utilizing a non-contact sensor in accordance with Usage Class:
a) See instructions on the placement of non-contact sensors for each type of application,
b) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving,
and
c) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable
by a moving gate or barrier.
10. For gate operators utilizing a contact sensor in accordance with Usage Class:
a) One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing
edge, and post-mounted both inside and outside of a vehicular horizontal slide gate.
b) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
c) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
d) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate
operator is not subjected to mechanical damage.
e) A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection
functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural
landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
f) One or more contact sensors shall be located on the inside and outside leading edge of a swing gate.
Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one
or more contact sensors shall be located on the bottom edge.
g) One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
CLASS I
Residential Vehicular Gate Operator - A vehicular gate
operator (opener or system) intended for use in a home
of one to four single family dwellings, or a garage or
parking area associated therewith.
CLASS II
CLASS II
Commercial/General Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for
use in a commercial location or building such as a
multi-family housing unit (five or more single family
units) hotel, garages, retail store or other building
servicing the general public.
UL 325 Requirements
CLASS III
CLASS III
Industrial/Limited Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for
use in a industrial location, loading dock area or other
location not intended to service the general public.
CLASS IV
CLASS IV
Restricted Access Vehicular Gate Operator - A vehicular
gate operator (opener or system) intended for use in a
guarded industrial location or buildings such as airport
security area or other restricted access locations not
servicing the general public, in which unauthorized
access is prevented via supervision by security
personnel.
Gate Type
Protection
Class I & II
Class III
Class IV
Horizontal Slide
Vertical Lift
Vertical Pivot Gate
Primary Type
A, B1, B2
A, B1, B2, D
Secondary Type
B1, B2, D
A, B1, B2, D, E
A, B1, B2, D, E
Primary Type
A, C
A, B1, B2, C
A, B1, B2, C, D
Secondary Type
A, B1, B2, C, D
A, B1, B2, D, E
A, B1, B2, C, D, E
Swing Gate or
Vertical Barrier (arm)
General Safety
CAUTION
Be sure to read and follow all the Eagle Access Control Systems, Inc. and UL instructions before installing and
operating any Eagle Access Control System, Inc. products. Eagle Access Control Systems, Inc. is not responsible
for any improper installation procedures caused by failure to comply with local building codes.
Precautions
Eagle swing gate operators are for vehicular use only. They are NOT for pedestrian use.
NO
Be sure to mount ALL gate operating devices at least ten feet (10) away
from any moving part of the gate. They must NOT be able to be operated
reaching through the gate.
BY EAGLE ACCESS CONTROL SYSTEMS, INC.
METHODS OF INSTALLATION
An experienced installer should perform the installation. Improper installation may result in property damage, severe injury or death.
Read the entire manual before proceeding with the installation.
Eagle Access Control Systems, Inc. is not responsible for researching and complying with local building codes. Be sure to check all local
building codes before installation.
Standard Installation
Hinge Center
Hinge Center
Eagle-100 - 19.5
Eagle-200 - 21.75
Closed Gate
Recommended Concrete
Pad Dimensions:
Eagle-100 - 20 x 24
Eagle-200 - 24 x 24
2
C
Concrete Pad
Hinge Center
Closed Gate
Open Gate
Wall
Hinge Center
Installation
Compact Installation
Concrete Pad
24
NOTE: If this dimension is less than
16 inches, secondary entrapment
protection is REQUIRED in this area.
See page 8 for more information.
1/2
Suggested concrete
depth dimension.
Check local building
24
codes in your area for
depth of concrete
before installation.
6
Ground Level
Open Gate
Compact - Inches
F G H I J
Eagle-100 35 22 28 11 26
Eagle-200 36 32 25 12 27
Bottom of
Easy Release
These two
gaps should
remain even
for proper fit.
Pin
S,
INC.
EM
L SY
RO
ST
NT
SS
CO
CE
E AC
BY
EA
GL
Support Bar
Installation
Gate
Attachment
Bracket
Support Bar
NO
Open Gate
NO
4 Reverse Loop
4
Sealant
4
1 1/2
Twisted
Loop Wire
Inside
PVC Conduit
Loops
Backer Rod
1/4
Cutaway of Groove
Loop Feed
Groove
4
Loop
Feed
EG
16
Lo
op
De
te
cto
r
ec
Det
Exit Loop
16
EG
ate
par
Se wer
Po
icle r
Vehecto
Det
Res
et
Secondary Entrapment
SENSOR
#8
EDGE
KEY
#7
CLOSE
#6
KEYPAD
#5
STOP
OPEN
#4
EXIT
LOOP
PHANTOM
LOOP
REVERSE
#3
GLOBAL INPUTS
itte
sm
n
Tra
ver
cei
Re
at
par
Se wer
o
P
Open Gate
Entrapment Area
Ind
ica
tor
4 Reverse Loop
4
wer
Po
LE Push Se
D
n
bu will & ho sit
tto bl
ivit
n up ink ld R
y
on from eset
/S
re
1 = achi 1 to en.
Ve ng 4 timbutto
To 3
ry
de
sire es. n
ch = N Lo
an or w
R
min ge mal , 2 = d se elea
i-loofrom , 4 Lo nsiti se
vity
p- indu= Higw,
.
se
e in ctiv h
stru e lo
Gre
ctio op to
en
ns
- St
.
ea
Fa dy in
st
Red
Sl blin dica
- D ow bl k - Shtes po
etec ink
orte wer
t In - O
dica pen d loop
tor loop
Phantom Loop
(Shadow Loop)
M/S Phase
Feature Selector
Limit Switches
See below
See page 12
See page 10
SELECT
Eagle Plug-In
Loop Detector
Connections
See instructions
on the Eagle loop
detectors when
using them.
Power
Power
Detect
Detect
EG167
See page 13
Factory Set
ERD Sensor
MIN
MAX
Fine Tune
Adjustment.
Please call
Eagle
Access
before any
adjustment.
See page 12.
EXIT
EG167
Vehicle
Detector
Fuse
Vehicle
Detector
Reset
Reset
REVERSE LOOP
Radio Receiver
RESET
SHADOW
SHADOW LOOP
15 Amp
250V
Slow-Blow
EXIT LOOP
#1
GND
RCVR
24VAC
GND
Cycles Operator
- 12 VDC
#12
POWER
24 VAC
#11
+ ALARM
#10
- 24 VDC
RELAY
#9
MAGLOCK
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
#4
OPEN
3-Button Station
#3
EXIT
#2
STOP
+ MAGLOCK
OPEN
LOOP
GATE STATUS
EXIT
OPEN
RECEIVER
Eagle Plug-In
Loop Detector
ERD STATUS
TIMER
CLOSE
LIMIT
SHADOW
LOOP
PHANTOM
Indicators
Green - Steady indicates power
Fast blink - Shorted loop
Slow blink - Open loop
Red - Detect Indicator
OPENING CLOSING
Diamond Board
OPEN
LIMIT
OPENING CLOSING
M/S PHASE
LOOP
Sensitivity
Push & hold Reset/Sen. button
LED will blink from 1 to 4 times. Release
button upon reaching desired sensitivity.
HEAVY
REVERSE
LOOP
REVERSE
EG167
OVERLOAD
REVERSE
Loop Detector
LIGHT
ACTIVE
MASTER
SLAVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFFON
1 2 3 4 5 6 7 8
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
ON
Reset Button
#13
#14
SLAVE MASTER
+
CLOSE
GLOBAL INPUTS
OUTPUTS
COMM PORT
Global Inputs
Outputs
Master/Slave
See page 12
See page 15
SLAVE
Switch #3: Motor Brake - If the ON position is selected, the gate will stop instantly when
the limit switch is activated. This is useful for uphill/downhill applications and on all fail-safe operators.
ON
1 2 3 4 5 6 7 8
Switch #1: Slave/Master - Sets the operator to work as Master or Slave. Single operator
MUST be set to MASTER.
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
OFFON
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
MASTER
SELECT
NOTE: The power MUST be turned OFF before changing the features selector switches.
Switch #4: Reverse Loop - Sets the reverse loop to be normally open (NO) or normally close (NC). It is useful in fail-safe applications.
Normal setting is OFF (Normally Open).
Be sure that the circuit breaker for the input power is turned OFF
before connecting the input power to the operator.
All operators MUST be properly grounded. Installing surge protection
is recommended.
120 VAC power
outlet provided.
120 VAC
Wire Color Description
Black - 120 VAC input power
White - Neutral input
Green - Ground input
(from an approved grounding method)
IMPORTANT: DO NOT
cycle the operator before
setting the limit switches.
Damage or injury could
occur if limit switches are
NOT set. (See below)
Junction Box
White
Green
Feature Selector #2
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFFON
SLAVE
ON
1 2 3 4 5 6 7 8
Limit Switches
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
Top Limit
Switch Activator
Set Screw
GATE STATUS
Top Limit
Switch
Bottom Limit
Switch
Indicates the
direction the
gate is cycling.
10
MIN
OPENING CLOSING
CLOSE
LIMIT
GATE STATUS
EXIT
OPEN
REVERSE
SHADOW
REVERSE LOOP
SHADOW LOOP
EXIT
OPEN RIGHT
CLOS
CLOSE
LOS
LIMIT
GATE STATUS
Bottom Limit
Switch
Top Limit
Switch
Indicates the
direction the
gate is cycling.
GND
RCVR
EXIT LOOP
#1
24VAC
GND
#12
POWER
24 VAC
- 12 VDC
#11
+ ALARM
#10
- 24 VDC
RELAY
#9
MAGLOCK
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
#3
LOOP
#2
STOP
+ MAGLOCK
OPEN
3-button
station
cycles
operator.
PHANTOM
OPENING CLOSING
LOOP
OPEN
LIMIT
REVERSE
CLOS
CLOSE
LOS
LIMIT
OPEN
LIMIT
SHADOW
LOOP
RECEIVER
OPENING CLOSING
HEAVY
OPENING CLOSING
ERD STATUS
REVERSE
LOOP
OPEN
LIMIT
OVERLOAD
TIMER
M/S PHASE
OPEN LEFT
LIGHT
ACTIVE
MAX
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFFON
MASTER
ON
1 2 3 4 5 6 7 8
SLAVE
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
#13
#14
SLAVE MASTER
+
CLOSE
GLOBAL INPUTS
OUTPUTS
COMM PORT
Bottom Limit
Switch Activator
These two
gaps should
remain even
for proper fit.
SS
BY
EA
CO
NT
EM
ST
L SY
RO
S,
Emergency Release
INC.
CE
E AC
GL
Clutch
Reset Motor
There is a red reset button on top of the 115 VAC motor. If the
motor ceases to function, TURN THE POWER OFF AND ALLOW
THE MOTOR TO COOL DOWN, then press the reset button.
11
OFFON
MAX
MIN
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
MASTER
SLAVE
ON
1 2 3 4 5 6 7 8
Timer
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
TIMER
If the gate operator enters overload status two times in a row, the alarm will sound until manually reset.
LIGHT
ACTIVE
OV
OV
OVERLOAD
CAUTION
HEAVY
Only a qualified service technician must make all adjustments to these sensors.
The Diamond Control Board has a sensitivity adjustment for the OPENING direction and
CLOSING direction of the gate. Both MUST be adjusted.
Adjustment must be made so that the gate stops and reverses when meeting an
obstruction equal to approximately 20 lbs. of stopping force.
OPENING CLOSING
ERD STATUS
LIGHT
More
Sensitive
HEAVY
Opening
Gate
Gate
Direction Direction
#11 ALARM (12 VDC): Safety Alarm - If the gate hits an obstruction twice while closing or
opening, the system will shut down for 5 minutes. On the diamond board, you have two options
of reset mode (Feature Selector switch #7):
OFF setting - The system will require a Manual Reset of the board after the gate
hits an obstruction twice while closing or opening.
ON setting - The system will automatically reset itself.
#12 POWER (24 VAC): Provides 24 VAC power which can be used for external loop detectors
and receivers.
12
NO
OUTPUTS
#12
POWER
24 VAC
- 12 VDC
#11
+ ALARM
#10
- 24 VDC
RELAY
#10 MAGLOCK (24 VDC): Provides a 24 VDC and relay output for maglock or solenoid locks.
NC
MAGLOCK
#9
+ MAGLOCK
#9 MAGLOCK RELAY: (NO-COM-NC Relay) - Can be used to control higher powered maglocks
that cant be powered by the diamond boards #10 output connection.
COM
Outputs
SENSOR
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
#3
PHANTOM
LOOP
REVERSE
#2
LOOP
Global Inputs
Radio receiver terminal is mounted on the outside of the control box for easy
installation and is pre-wired for a 3-wire or a 4-wire receiver. The Radio receiver
terminal is wired to the control board #1 as shown below.
3-Wire Receiver
RADIO POWER
RADIO POWER
RET
(24V)
RADIO POWER
RADIO POWER
RELAY
RELAY RET
24V
(24V)
Black
Grey
From #4
Red
Orange
RECEIVER
From #3
24V
3
Wire
4
Wire
4
(24V)
RET
24V
3
Wire
RADIO POWER
4
Wire
RADIO POWER
(24V)
RELAY COMMON GROUND
RELAY
RELAY RET
24V
4
(24V)
RET
Control Board
Connection #1
White
From #1
From #2 Black
1
RELAY RET
Grey
Radio Receiver
Terminal Wires
2
RELAY
Red
(24V)
RELAY COMMON GROUND
24V
Radio
Receiver
Terminal
Radio Receiver
24V
3
Wire
4
Wire
4-Wire Receiver
GND
RCVR
#1
24VAC
GND
13
GLOBAL INPUTS
#10
- 24 VDC
+ MAGLOCK
RELAY
EDGE
#9
MAGLOCK
#8
SENSOR
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
PHANTOM
LOOP
REVERSE
#2
OUTPUTS
Safety Equipment
Maglock
Connecting Accessories
24 VDC
Max
ate
par
Se wer
Po
Safety Equipment
und op
Gro Lo
In- verse
e
R
und op
Gro Lo
In- verse
Re
Edge
Sensor
External Phantom
Loop (Shadow Loop)
Detector
Tra
n
sm
itte
ate
par
Se wer
o
P
Photocell Sensor
ate
par
Se wer
Po
Re
cei
und oop )
Gro L op
In- ntom w Lo
a
Ph hado
(S
ver
ate
par
Se wer
Po
e
at
par
Se wer
o
P
und p
Gro oo
In- xit L
E
Phone Entry
System
Fire Dept.
Lock Box
Dry Contact
Open
3-Button
Station
Close
Stop
4-Wire Connection
Dry Contact
14
Key
Switch
Lock Box
Dry Contact
MASTER
Operator
SLAVE
Operator
IMPORTANT: The 115 VAC power for the master and slave operators MUST be on the same circuit breaker.
It is recommended that each gate operators initial set-up is completed (Direction of gate travel, limit
switches, ERD reverse sensor and feature selector switches #1 - #4) before connecting the operators
together. After each operator functions individually, proceed to Master/Slave connection and operation.
(Master Operator)
#13
SLAVE MASTER
+
SLAVE MASTER
COMM PORT
#14
SLAVE
MASTER
OFFON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
ON
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
SLAVE
(Slave Operator)
COMM PORT
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
Diamond
Board
ONLY
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFFON
MASTER
Diamond
Board
ONLY
#14
#13
TIMER
ON
1 2 3 4 5 6 7 8
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
OFFON
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
MASTER
SELECT
SLAVE
MIN
MAX
#5 OPEN DELAY S: Turning #5 - ON delays opening the SLAVE gate by 1.5 seconds.
# 6 must be turned OFF. This is useful for magnetic lock applications.
#6 OPEN DELAY M: Turning #6 - ON delays opening the MASTER gate by 1.5 seconds.
# 5 must be turned OFF. This is useful for magnetic lock applications.
TIMER
MAX
PROBABLE CAUSE
REMEDY
(D) Check and/or replace the fuse with same amp fuse.
1-800-708-8848
16
Radio
ReceiverTerminal
24V
(24V)
3
Wire
RADIO POWER
4
Wire
RADIO POWER
RELAY
RELAY RET
24V
(24V)
RET
Green Com
Diamond Board
OFFON
LIGHT
MIN
MAX
ACTIVE
OVERLOAD
HEAVY
OPEN
LIMIT
OPENING CLOSING
OPENING CLOSING
ERD STATUS
TIMER
CLOSE
LIMIT
GATE STATUS
M/S PHASE
115 VAC
Outlet
Power
Switch
OFF
ON
RESET
White
Neutral
Black
Hot
REVERSE
LOOP
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
MASTER
ON
1 2 3 4 5 6 7 8
SLAVE
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
SHADOW
LOOP
EXIT
OPEN
SHADOW
REVERSE LOOP
SHADOW LOOP
EXIT
Orange
White
Black
RECEIVER
GND
RCVR
12-Pin
Plug
EXIT LOOP
#1
24VAC
GND
10
11
12
Black
9
10
Green
#13
#14
SLAVE MASTER
+
CLOSE
Green
COMM PORT
Black
OUTPUTS
Red
GLOBAL INPUTS
Junction Box
- 12 VDC
#12
POWER
24 VAC
#11
+ ALARM
#10
- 24 VDC
RELAY
#9
MAGLOCK
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
Alarm
12-Pin Plug
11
6
12
Eagle-200-1HP
4
11
12
Eagle-200-DM
1/2 HP
Motor
2 1/2 Pulley
Gray
Red
4
11
12
Blue
Blue
1 HP
Motor
7
8
Blue
Red
Red
115 VAC
Input
12-Pin Plug
Blue
Gray
Gray
Blue
Red
Ground
Black
White
Green
STOP
OPEN
#4
EXIT
LOOP
#3
PHANTOM
LOOP
#2
STOP
+ MAGLOCK
OPEN
REVERSE
Red
Green
REVERSE
2 Pulley
1/2 HP
Motor
Dual Motors
Eagle-100
Eagle-200
1/2 HP
Motor
2 Pulley
2 1/2 Pulley
17
E151/
E728
E724
E180/
E182
E729
24V
(24V)
3
Wire
RADIO POWER
4
Wire
RADIO POWER
RELAY
RELAY RET
24V
4
(24V)
RET
E186
Complete Swing
Arm Assembly
E515
E153
E146
E476
Right
E192A/
E196A
E475
E721
E116
E722
E723
E130
E471
E190/
E195
E185
E472
E191
E193/
E197
E148
E147
V-Belt
E173/
E174 (DM)
Left
E192B/
E196B
E473
Complete Limit
Switch Assembly
E105/E101
E725
E727
E103
E102/
E104
E726
E131
OFFON
MIN
OVERLOAD
TIMER
E226/
E115
HEAVY
OPEN
LIMIT
OPENING CLOSING
OPENING CLOSING
CLOSE
LIMIT
GATE STATUS
ERD STATUS
M/S PHASE
RESET
REVERSE
LOOP
E555
LIGHT
ACTIVE
MAX
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
MASTER
1 2 3 4 5 6 7 8
ON
SLAVE
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
E225/
E114
SHADOW
LOOP
EXIT
OPEN
REVERSE
SHADOW
REVERSE LOOP
SHADOW LOOP
EXIT
E175
RECEIVER
GND
RCVR
EXIT LOOP
#1
24VAC
GND
#12
POWER
24 VAC
#11
- 12 VDC
- 24 VDC
#10
+ ALARM
RELAY
#9
MAGLOCK
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
PHANTOM
LOOP
REVERSE
#2
STOP
+ MAGLOCK
OPEN
#13
#14
SLAVE MASTER
+
CLOSE
GLOBAL INPUTS
OUTPUTS
E222/
E111
COMM PORT
CES
E AC
Right
Leg
Left
Leg
BY
NT
RO
L SY
STE
.
, INC
MS
GL
EA
E223
E525
E224
18
S CO
1-800-708-8848
M/S Phase
Close Timer - See page 24
Feature Selector
Reverse Sensor
Limit Switches
See page 24
See page 22
SELECT
MH2
MAX
MIN
See
page 21
M/S PHASE
Reset Button
RESET
SHADOW
Detect
Detect
5-Pin Primary
Connector
See page 21
FUSE MAX 35A
EG167
EG167
Vehicle
Detector
Reset
RECEIVER
RELAY #1
RELAY
24VDC
-24VDC
20 Amp
MOTOR
Vehicle
Detector
Reset
BATTERY
Power
Power
20
EXIT
REVERSE
20
EXIT
OPEN
Secondary
ERD Sensor
Fine Tune
Adjustment
See page 24
MH4
REVERSE LOOP
SHADOW LOOP
AC POWER
24VAC
SOLAR
POWER
LOW
BATTERY
CHARGER
ON
EXIT LOOP
24 VDC Output
Remains ON
Power Save Mode
See below
Power
Indicator
LEDs
See page 21
#14
MASTER
+
1
GLOBAL INPUTS
DIAMOND
DC
- (12 VDC)
#13
SLAVE
GND
CLK
#12
POWER 24 VDC
GND
CLK
#11
+ ALARM
#10
- (24 VDC)
+ MAGLOCK
#9
MAG LOCK
N/C
#8
N/O
COM
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
CLOSE
LOOP
Cycles Operator
#3
SHADOW
STOP
LOOP
#2
3-Button Station
SENSOR
OPEN
REVERSE
CLOSE
LIMIT
GATE STATUS
ERD STATUS
1
2
3
SHADOW
LOOP
See instructions
on the Eagle loop
detectors when
using them.
Radio
Receiver
OPENING CLOSING
P/O ADJUST
REVERSE
LOOP
Eagle Plug-In
Loop Detector
Connections
Eagle Plug-In
Loop Detector
OPEN
LIMIT
OPENING CLOSING
SOLAR
Indicators
Green - Steady indicates power
Fast blink - Shorted loop
Slow blink - Open loop
Red - Detect Indicator
HEAVY
1 2 3 4
Sensitivity
Push & hold Reset/Sen. button
LED will blink from 1 to 4 times. Release
button upon reaching desired sensitivity.
OFFON
MH3
OVERLOAD
TIMER
+
OFF
OFF
OFF
ON
EG167
Loop Detector
1 2 3 4
OFFON
PWR FAIL OPERATION
AUTO OPEN ON
AUTO OPEN OFF
POWER FAIL CLOSE
POWER FAIL OPEN
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
LIGHT
ACTIVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
ON
1 2 3 4 5 6 7 8
ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
MH1
Diamond DC Board
OUTPUTS
COMM PORT
Global Inputs
Outputs
Master/Slave
See page 24
See page 27
24 VDC Output
Minimizes
Power Save Mode
See below
Switch #1: Slave/Master - Sets the operator to work as Master or Slave. Single operator
MUST be set to MASTER.
Switch #2: Gate Opening - designates left or right opening direction.
ON
NOTE: The power MUST be turned OFF before changing the features selector switches.
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
1 2 3 4 5 6 7 8
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
OFFON
Switch #3: Motor Brake - This switch MUST remain OFF for DC operator. The brake feature CANNOT be used for a DC motor.
Switch #4: Reverse Loop - Sets the reverse loop to be normally open (NO) or normally close (NC). It is useful in fail-safe applications.
Normal setting is OFF (Normally Open).
Switches #5 - #8
Switch #5: One Pass (ON/OFF) - This tailgating feature works with the reverse loop to allow only one vehicle to pass the gate. After the vehicle
passes, the gate closes instantly. If a second vehicle approaches, the gate stops. The gate resumes closing after the vehicle leaves.
Switch #6: Stop-Reverse (ON/OFF) - The radio feature allows the transmitter to work as a three-button station and is useful for a partial
opening. If selected, the first command will open the gate, the second command will stop the gate and the third command will close the gate.
Switch #7: Alarm Reset (ON/OFF) - If the ON position is selected, after the five minute Shutdown time period, the operator will reset and any
input will be accepted. Normally, the power must be turned of to reset.
ON
1 2 3 4
Diamond DC Board
Switch #8: Close Timer (ON/OFF) - Turns the close timer ON or OFF. See page 24.
Switch #1: AUTO OPEN OFF: When AC power fails, the gate REMAINS OPERATIONAL until
OFFON
AC power is restored. NOTE: When using solar power, AUTO OPEN OFF MUST be used.
AUTO OPEN ON: When AC power fails, the gate will move to the FULL OPEN POSITION and remain open until AC power is restored.
NOTE: After power is restored, gate will remain open until a close command is made.
Switch #2: Operator will automatically shut down before battery power gets too weak to continue safe operation.
Power Fail Open - OFF: When battery voltage drains to its minimum allowable level, the gate will move to the FULL OPEN position and
remain open until AC power is restored or battery voltage returns to normal.
Power Fail Close - ON: When battery voltage drains to its minimum allowable level, the gate will move to the FULL CLOSED position and
remain closed until AC power is restored or battery voltage returns to normal.
1 2
3 4
NOTE: These 2 switches remain OFF EXCEPT when using bi-parting overlapping gates.
See page 27 for Master/Slave Setup.
20
ON
1 2 3 4
1
2
3
P/O ADJUST
AC POWER
24VAC
SOLAR
POWER
LOW
BATTERY
CHARGER
ON
Diamond DC Board
Power ON/OFF Switch and 5-Pin Primary Plug for Diamond DC Board
Power Switch
OFF
ON
SELECT
MIN
OVERLOAD
TIMER
1 2 3 4
+
OFF
OFF
OFF
ON
1 2 3 4
ON
OFFON
PWR FAIL OPERATION
AUTO OPEN OFF
AUTO OPEN ON
POWER FAIL OPEN
POWER FAIL CLOSE
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
HEAVY
OPENING CLOSING
OPEN
LIMIT
OPENING CLOSING
1
2
3
M/S PHASE
RESET
SOLAR
20
EXIT
OPEN
MH4
SHADOW
20
EXIT
REVERSE
SHADOW
LOOP
REVERSE
LOOP
MH3
CLOSE
LIMIT
GATE STATUS
ERD STATUS
P/O ADJUST
OFFON
BATTERY
+
20 Amp
MOTOR
+
SHADOW LOOP
AC POWER
24VAC
SOLAR
POWER
LOW
BATTERY
CHARGER
ON
EXIT LOOP
RELAY #1
RELAY
+
24VDC
-24VDC
GLOBAL INPUTS
#13
SLAVE
+
#14
MASTER
+
COMM PORT
GND
CLK
- (12 VDC)
OUTPUTS
DIAMOND
DC
#12
POWER 24 VDC
CLOSE
GND
CLK
#11
+ ALARM
N/C
#10
- (24 VDC)
#9
MAG LOCK
N/O
COM
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
SHADOW
LOOP
REVERSE
#2
STOP
+ MAGLOCK
OPEN
Junction Box
REVERSE LOOP
RECEIVER
LIGHT
ACTIVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
MAX
1 2 3 4 5 6 7 8
MH2
ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
MH1
WARNING: Eagle Access Control Systems, Inc. is not responsible for researching and complying
with local building codes. Be sure to check all local building codes before installation.
CAUTION
Be sure that the circuit breaker for the line input power is turned OFF before connecting the
input power to the operator.
120 VAC
Junction Box
Black wire to Black wire.
White wire to White wire.
Green wire to Green wire.
120 VAC Input
Power Wire
240 VAC
Three Phase
Input Power Wire
Black
Junction
Box
Junction Box
Black
Gray
White
Terminated Wire
Green
Green
The limit switches MUST be set so the gate stops at the correct open and close positions.
the control board MUST have power for the limit LEDs when setting the limit switches.
Adjust the close limit switch FIRST when the gate is in the closed position.
Feature Selector #2
SELECT
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
OFFON
SELECT
LIGHT
MAX
ACTIVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
MIN
1 2 3 4 5 6 7 8
MH2
ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
MH1
OVERLOAD
TIMER
OFFON
1 2 3 4
+
OFF
OFF
OFF
ON
1 2 3 4
ON
OFFON
PWR FAIL OPERATION
AUTO OPEN ON
AUTO OPEN OFF
POWER FAIL CLOSE
POWER FAIL OPEN
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
HEAVY
OPENING CLOSING
OPEN
LIMIT
OPENING CLOSING
M/S PHASE
RESET
P/O ADJUST
SOLAR
+
EXIT
OPEN
20
SHADOW
LOOP
MH4
SHADOW
20
EXIT
REVERSE
REVERSE
LOOP
MH3
CLOSE
LIMIT
GATE STATUS
ERD STATUS
1
2
3
Limit Switches
ON
1 2 3 4 5 6 7 8
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
Top Limit
Switch
Bottom Limit
Switch
Indicates the
direction the
gate is cycling.
22
OPEN
LIMIT
OPENING CLOSING
CLOS
CLOSE
LOS
LIMIT
SHADOW LOOP
AC POWER
24VAC
SOLAR
POWER
LOW
BATTERY
CHARGER
ON
EXIT LOOP
RELAY #1
RELAY
+
24VDC
-24VDC
Bottom Limit
Switch
Indicates the
direction the
gate is cycling.
GLOBAL INPUTS
OUTPUTS
#13
SLAVE
+
#14
MASTER
+
COMM PORT
GND
CLK
CLOSE
DIAMOND
DC
#12
POWER 24 VDC
+ ALARM
#11
- (12 VDC)
N/C
COM
#10
- (24 VDC)
#9
MAG LOCK
N/O
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
SHADOW
STOP
LOOP
#2
3-button
station
Top Limit
cycles
Switch operator.
+ MAGLOCK
OPEN
GATE STATUS
GND
CLK
GATE STATUS
20 Amp
REVERSE LOOP
REVERSE
CLOS
CLOSE
LOS
LIMIT
MOTOR
+
OPENING CLOSING
OPEN RIGHT
RECEIVER
OPEN
LIMIT
BATTERY
+
OPEN LEFT
Emergency Release
EM
SS
BY
EA
CO
NT
S,
INC.
ST
L SY
RO
CE
E AC
GL
4
Wire
RADIO POWER
(24V)
RELAY COMMON GROUND
RELAY
RELAY RET
24V
4
(24V)
Clutch
3
Wire
RET
23
OFFON
MAX
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
MIN
ON
1 2 3 4 5 6 7 8
Timer
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
TIMER
If the gate operator enters overload status two times in a row, the alarm will sound until manually reset.
LIGHT
Reverse Sensor
ACTIVE
OV
OV
OVERLOAD
CAUTION
HEAVY
Only a qualified service technician must make all adjustments to these sensors.
The Diamond Control Board has a sensitivity adjustment for the OPENING direction and
CLOSING direction of the gate. Both MUST be adjusted.
Adjustment must be made so that the gate stops and reverses when meeting an
obstruction equal to approximately 20 lbs. of stopping force.
OPENING CLOSING
ERD STATUS
LIGHT
More
Sensitive
HEAVY
Opening
Gate
Gate
Direction Direction
#12 POWER (24 VDC): Connect accessories to this when using the POWER SAVE MODE to
maximize operating cycles when AC power is not present. See page 19.
24
#11
#12
- 12 VDC
POWER 24 VDC
+ _
+ ALARM
#10
- 24 VDC
N/C
#11 ALARM (12 VDC): Safety Alarm - If the gate hits an obstruction twice while closing or
opening, the system will shut down for 5 minutes. On the Diamond DC board, you have two
options of reset mode (Feature Selector switch #7):
OFF setting - The system will require a Manual Reset of the board after the gate
hits an obstruction twice while closing or opening.
ON setting - The system will automatically reset itself.
COM
#10 MAGLOCK (24 VDC): Provides a 24 VDC and relay output for maglock or solenoid locks.
#9
MAG LOCK
N/O
Outputs
#9 MAGLOCK RELAY: (NO-COM-NC Relay) - Can be used to control higher powered maglocks
that cant be powered by the Diamond DC boards #10 output connection.
+ MAGLOCK
OUTPUTS
SENSOR
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
#3
SHADOW
LOOP
REVERSE
#2
LOOP
Global Inputs
3-Wire Receiver
RADIO POWER
RADIO POWER
RET
(24V)
RADIO POWER
RADIO POWER
RELAY
RELAY RET
24V
(24V)
Black
Grey
From #4
Red
Orange
RECEIVER
From #3
24V
3
Wire
4
Wire
4
(24V)
RET
24V
3
Wire
RADIO POWER
4
Wire
RADIO POWER
(24V)
RELAY COMMON GROUND
RELAY
RELAY RET
24V
4
(24V)
RET
Control Board
Connection #1
White
From #1
From #2 Black
1
RELAY RET
Grey
Radio Receiver
Terminal Wires
2
RELAY
Red
(24V)
RELAY COMMON GROUND
24V
Radio
Receiver
Terminal
Radio Receiver
24V
3
Wire
4
Wire
4-Wire Receiver
RELAY #1
RELAY
24VDC
-24VDC
25
GLOBAL INPUTS
#10
- 24 VDC
N/C
COM
MAG LOCK
N/O
EDGE
#9
+ MAGLOCK
#8
SENSOR
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
SHADOW
LOOP
REVERSE
#2
OUTPUTS
Safety Equipment
Maglock
Connecting Accessories
24 VDC
Max
ate
par
Se wer
o
P
Safety Equipment
und op
Gro Lo
In- verse
Re
und op
Gro Lo
In- verse
e
R
Edge
Sensor
Tra
n
sm
itte
ate
par
Se wer
Po
at
par
Se wer
Po
Photocell Sensor
Re
cei
und op
Gro Lo
In- adow
h
S
ver
ate
par
Se wer
o
P
und p
Gro oo
In- xit L
E
ate
par
Se wer
Po
Phone Entry
System
Fire Dept.
Lock Box
Dry Contact
Open
3-Button
Station
Close
Stop
4-Wire Connection
Dry Contact
26
Key
Switch
Lock Box
Dry Contact
MASTER
Operator
SLAVE
Operator
(Master Operator)
#14
SLAVE
+
MASTER
+
(Slave Operator)
COMM PORT
COMM PORT
SELECT
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
OFFON
ON
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
Diamond
DC Board
ONLY
CLK
GND
CLK
GND
CLK
GND
Diamond
DC Board
ONLY
#13
MASTER
CLK
#14
GND
#13
SLAVE
IMPORTANT: The 115 VAC power for the master and slave operators MUST be on the same circuit
breaker. It is recommended that each gate operators initial set-up is completed (Direction of gate travel,
limit switches, reverse sensor and feature selector switches #1 - #4) before connecting the operators
together. After each operator functions individually, proceed to Master/Slave connection and operation.
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
OFFON
MAX
MIN
TIMER
3 4
ON
1 2
27
PROBABLE CAUSE
REMEDY
(D) Check and/or replace the fuse with same amp fuse.
1-800-708-8848
28
Radio
ReceiverTerminal
24V
(24V)
3
Wire
RADIO POWER
4
Wire
RADIO POWER
115 VAC
Outlet
RELAY
RELAY RET
24V
(24V)
RET
SELECT
LIGHT
MAX
ACTIVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
MIN
1 2 3 4 5 6 7 8
TIMER
1 2 3 4
+
OFF
OFF
OFF
ON
1 2 3 4
ON
OFFON
PWR FAIL OPERATION
AUTO OPEN ON
AUTO OPEN OFF
POWER FAIL CLOSE
POWER FAIL OPEN
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
OVERLOAD
OFF
HEAVY
OPEN
LIMIT
OPENING CLOSING
OPENING CLOSING
M/S PHASE
SOLAR
20
EXIT
5-Pin
Primary
Plug
24VAC
AC
N
G
BATTERY
White
White
Blue
Blue
SHADOW
FUSE MA
MAX 20A
MH4
REVERSE
White
Black
Black
220
EXIT
OPEN
SHADOW
LOOP
Transformer
Limit
Switch
Plug
RESET
P/O ADJUST
OFFON
REVERSE
LOOP
MH3
Black
Hot
GATE STATUS
ERD STATUS
1
2
3
ON
CLOSE
LIMIT
Green
MH2
ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
Diamond DC Board
MH1
White
Neutral
Power
Switch
Green
Red
Black
REVERSE LOOP
SHADOW LOOP
RELAY #1
RELAY
SOLAR
POWER
24 VDC
LOW
BATTERY
CHARGER
ON
Motor
Plug
Black
White
Gray
Black
Red
-24VDC
Ground
COMM PORT
Black
Green
White
Black
Alarm
1/2 HP
or
3/4 HP
Motor
Black
120 VAC
Input
Red
Green
OUTPUTS
Red
GLOBAL INPUTS
#14
MASTER
DIAMOND
DC
- (12 VDC)
CLOSE
#13
SLAVE
GND
CLK
#12
POWER 24 VDC
GND
CLK
#11
+ ALARM
N/C
#10
- (24 VDC)
#9
MAG LOCK
N/O
COM
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
SHADOW
LOOP
REVERSE
#2
+ MAGLOCK
OPEN
STOP
Green
24VDC
Green
RECEIVER
AC POWER
24VAC
EXIT LOOP
Junction Box
White
Orange
Black
MOTOR
Red
20 Amp
Battery Pack
12 V
Battery
12 V
Battery
29
Radio
ReceiverTerminal
24V
(24V)
3
Wire
RADIO POWER
4
Wire
RADIO POWER
115 VAC
Outlet
RELAY
RELAY RET
24V
(24V)
RET
Diamond DC Board
SELECT
LIGHT
MAX
ACTIVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
MIN
1 2 3 4 5 6 7 8
TIMER
OFFON
1 2 3 4
+
OFF
OFF
OFF
ON
1 2 3 4
ON
OFFON
PWR FAIL OPERATION
AUTO OPEN ON
AUTO OPEN OFF
POWER FAIL CLOSE
POWER FAIL OPEN
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
OVERLOAD
OFF
HEAVY
OPEN
LIMIT
OPENING CLOSING
OPENING CLOSING
M/S PHASE
SOLAR
20
EXIT
5-Pin
Primary
Plug
24VAC
AC
N
G
BATTERY
White
White
Blue
Blue
SHADOW
FUSE MA
MAX 20A
MH4
REVERSE
White
Black
Black
220
EXIT
OPEN
SHADOW
LOOP
Transformer
Limit
Switch
Plug
RESET
P/O ADJUST
REVERSE
LOOP
MH3
Black
Hot
GATE STATUS
ERD STATUS
1
2
3
ON
CLOSE
LIMIT
Green
MH2
ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
MH1
White
Neutral
Power
Switch
Green
Red
Black
REVERSE LOOP
SHADOW LOOP
RELAY #1
RELAY
SOLAR
POWER
24 VDC
LOW
BATTERY
CHARGER
ON
Motor
Plug
Black
White
Gray
Black
Red
-24VDC
Green
24VDC
Green
RECEIVER
AC POWER
24VAC
EXIT LOOP
Ground
COMM PORT
Black
Green
OUTPUTS
Red
GLOBAL INPUTS
#14
MASTER
DIAMOND
DC
- (12 VDC)
CLOSE
#13
SLAVE
GND
CLK
#12
POWER 24 VDC
GND
CLK
#11
+ ALARM
N/C
#10
- (24 VDC)
#9
MAG LOCK
N/O
COM
SENSOR
#8
EDGE
#7
CLOSE
KEYPAD
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
SHADOW
LOOP
REVERSE
#2
STOP
+ MAGLOCK
OPEN
Green
Gray
Black
Alarm
1/2 HP
or
3/4 HP
Motor
Red
Black
240 VAC
Input
Battery Pack
30
Junction Box
White
Orange
Black
MOTOR
Red
20 Amp
12 V
Battery
12 V
Battery
(24V)
3
Wire
RADIO POWER
4
Wire
RADIO POWER
E729
RELAY
RELAY RET
24V
4
(24V)
RET
E186
Complete Swing
Arm Assembly
E515
E153
E146
E476
Right
E192A/
E196A
E475
E721
E116
E722
E723
E190/
E195
Battery Packs
EG054 - 12 VDC 7 Amp
EG059 - 12 VDC 9 Amp
EG052 - 12 VDC 35 Amp
E130
E471
E191
E472
E147
E193/
E197
E173
Left
E192B/
E196B
E473
Complete Limit
Switch Assembly
E105/E101
E725
E727
E103
E102/
E104
E726
E131
SELECT
LIGHT
MAX
ACTIVE
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS ON
STOP-REVERSE ON
ALARM-RESET ON
CLOSE TIMER ON
MIN
1 2 3 4 5 6 7 8
MH2
ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
ONE PASS OFF
STOP-REVERSE OFF
ALARM-RESET OFF
CLOSE TIMER OFF
MH1
OVERLOAD
1 2 3 4
1 2 3 4
1
2
3
OPEN
LIMIT
OPENING CLOSING
CLOSE
LIMIT
GATE STATUS
M/S PHASE
RESET
P/O ADJUST
OFFON
SOLAR
+
20
EXIT
OPEN
MH4
SHADOW
20
EXIT
E175
REVERSE
SHADOW
LOOP
REVERSE
LOOP
MH3
E226/
E115
HEAVY
OPENING CLOSING
ERD STATUS
TIMER
+
OFF
OFF
OFF
ON
OFFON
PWR FAIL OPERATION
AUTO OPEN ON
AUTO OPEN OFF
POWER FAIL CLOSE
POWER FAIL OPEN
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
ON
E600
E225/
E114
20 Amp
MOTOR
+
REVERSE LOOP
SHADOW LOOP
SOLAR
POWER
LOW
BATTERY
CHARGER
ON
EXIT LOOP
RELAY #1
RELAY
RECEIVER
AC POWER
24VAC
24VDC
-24VDC
GLOBAL INPUTS
- (12 VDC)
#13
SLAVE
+
#14
MASTER
+
GND
CLK
#12
POWER 24 VDC
OUTPUTS
DIAMOND
DC
#11
CLOSE
GND
CLK
- (24 VDC)
N/C
COM
#10
+ ALARM
#9
MAG LOCK
N/O
SENSOR
#8
EDGE
KEYPAD
#7
CLOSE
#6
KEY
#5
STOP
OPEN
#4
EXIT
LOOP
#3
SHADOW
LOOP
REVERSE
#2
STOP
+ MAGLOCK
OPEN
E222/
E111
COMM PORT
CES
E AC
Right
Leg
Left
Leg
BY
S CO
NT
RO
L SY
STE
MS
.
, INC
GL
EA
E223
E525
1-800-708-8848
E224
31
NOTES
32
NOTES
33
TM
Eagle-100 Series
Eagle-200 Series
www.eagleoperators.com
Toll Free: 1-800-708-8848
Phone: (818) 837-7900
Fax: (818) 837-7911
Copyright 2013 Eagle Access Control systems, Inc. All rights reserved.