RESIDENTIAL CHECKLIST

EXIT DETAILS
Capacity of Horizontal Exit (Corridor/Hallway):__3___
Capacity of Exit Stair:___________1_______________
No. of Exits __________3__________ Remote? [ ] Yes [ ] No
Location of Exits __Main Entrance and Kitchen
Any Enclosure Provided? [ ] Yes[ ]No
MEANS OF EGRESSS
[ ] Yes [ ] No Obstructed?

Readily accessible?

[ ] Yes [ ] No

Travel distance within limits? [ ] Yes [ ]


Adequate illumination

[ ] Yes [ ] No Proper rating of illumination?

[]

Yes [ ] No
Door swing in the direction of exit? [ ] Yes [ ] No
Doors open easily?

[ ] Yes [ ]

Corridors & aisles of sufficient size? [ ] Yes [ ] No


A. VERTICAL EXITS
1. Main stairway: Width ______1.1m_____Construction
____________Wood___________
Are there railings provided? [ ] Yes [ ] No
of_____________Wood______________________

Made

Any enclosure provided? [ ] Yes [ ] No


B. HORIZONTAL EXITS
Width of door/s ________1.2 and 0.8m_______ Construction____Lite
Metals______________
Door swing in the direction of egress travel? [ ] Yes [ ] No
With Self-closing device? [] Yes [ ] No
Exit readily visible? [ ] Yes [ ] No Clear and unobstructed? [ ] Yes [ ] No

Properly marked w/ illuminated exit sign? [ ] Yes [ ] No With illuminated


directional sign? [ ] Yes [ ] No
C. AREA OF SAFE REFUGE
Provided? [ ] Yes [ ] No
LIGHTINGS & SIGNS
A. EMERGENCY LIGHTS
Automatic Emergency Lights Provided? [ ] Yes [ ] No
B. EXIT SIGNS
Provided? [ ] Yes [ ] No
Exit Route Plan provided: Lobby/Hallways? [ ] Yes [ ] No Rooms? [ ] Yes
[ ] No
FEATURES OF FIRE PROTECTION
A. ALARM SYSTEM
Fire Alarm Provided? [ ] Yes [ ]
Smoke Detectors? [ ] Yes [ ] No
Heat Detectors? [ ] Yes [ ] No
B. STANDPIPE SYSTEM
Fire Hose Cabinets Provided? [ ] Yes [ ]
Fire Lane Provided: [ ] Yes [ ] No
C. AUTOMATIC FIRE SUPPRESSION SYSTEM
Provided? [ ] Yes [ ] No
D. MANUAL FIRE SUPPRESSION SYSTEM
Fire extinguisher provided [ ] Yes [ ] No
E. FIRE WALL
Building required with fire walls? [ ] Yes [ ] No

Provided? [ ] Yes [ ] No

BUILDING SERVICE EQUIPMENT


LPG Installation Covered with Permit? [ ] Yes [ ] No
Fuel with Storage Permit? [ ] Yes [ ] No
A. Generator Set Provided? [ ] Yes [ ] No
B. Refuse (Garbage) Handling Facility: Provided? [ ] Yes [ ] No
C. Electrical System
Is there any electrical hazard? [ ] Yes [ ] No
House_______

Specify location:__In Front of

D. Mechanical System
Is there any mechanical hazard? [ ] Yes [ ] No
__Garage_____

Specify location

E. Other Building Service Systems


HAZARDOUS AREAS
[ ] Kitchen [ ] Laundry [ ] Windowless Basement [ ] Storage Room
Others____________________
Presence of hazardous materials? [ ] Yes [ ] No
handled? [ ] Yes [ ] No
Kinds
1.
2.
3.
4.

Gasoline
Kerosene
Paint
Butane

Properly stored and

FINDINGS:
There was no proper rating of illumination for the means of
egress.Stairway has no enclosure provided. There was no exit sign
provided. No area of safe refuge available in case evacuation is
not possible.No emergency lights installed and exit route plan
provided either lobby or in rooms.No fire alarm,smoke detectors
and heat detectors installed.There was no available standpipe
system.No means of fire suppression system either automatic or
portable suppressant.Most of the walls are made of wood.LPG
installed and stored fuel wasnt covered with permit.Electric
hazard was found infront of the house where main electric wires a
hanging near the house.Hands tools and power tools are located
in the garage.There were hazardous material found in the storage
room but properly stored in a container and keep away from

sunlight.

RECOMMENDATIONS:
Every room, kitchen storage room and garage should have at
least one fire extinguisher provided. Fire evacuation plan should
be place on rooms and hallways. Family members shall practice
and must always know two escape path from their room. There
should be at least one working smoke detector on every floor.