Sie sind auf Seite 1von 23

Metering is our Business

Parameterization and reading tool


for Iskraemeco metering devices

30.6.2014

Metering is our Business

Contents
General features
Presentation of important features

Differences among editions


System requirements for SEP2 MeterView 2014

Metering is our Business

General features
SEP2 MeterView - application for reading, parameterization, upgrade
and other manipulation with Iskraemeco devices.
Tree view structure, where new device groups, devices and their
parameter schemes can be added. SEP2 MeterView stores all
information into its dedicated local database.
Each device can have one or more parameter schemas attached to it.
Powerful customisation options for operations and for look&feel.
SEP2 MeterView is available as a stand-alone application and as a
plugin module of the SEP2W System our data collection and
processing system.

Metering is our Business

Main application window


Ribbon bar (application settings and operation)
Autohide, close,
move workspace

Central Zone
Main working area. Here the user is
applying changes, retrieving
information, exporting

Workspace
System tree
with groups of
devices and
schemas

Plugins

Tabs
More than one tab can be used (opened)

Status bar (location of workspace file, current user info

Metering is our Business

Look and feel

Arrangementmultiple layouts
available

Event log and


Status bar

Visualisation
Multiple
palettes/themes
available

Metering is our Business

Access Management

Security policy

Users and groups

Metering is our Business

Device Wizard for easy adding of a metering device


A wizard guides you through the definiton of a meter

Metering is our Business

Device attributes and properties

Attributes

Properties

Location

Attributes Groups Communication, Protocols and SEP2 MeterView attributes

Metering is our Business

Read/Set/Synchronize time

SEP2 MeterView recalculates time according to local settings of the computer (time zone,
DST activation). Therefore, the time displayed here might differ from the time device shows
on its display.

Metering is our Business

Reading and surveying profiles Results Tab

Page navigation

Profile contents

Metering is our Business

Reading and surveying profiles Chart Tab

Which channels to
display

Type of chart

Metering is our Business

Reading and surveying profiles Report Tab

Print layout

Page Setup

Export to xls, pdf, doc


SEP2W

Metering is our Business

Data readout display modes (from v. 2014)


DRO data can be read as raw, current, billing or current & billing
values
Export of billing and current values is possible also to SEP2W
System.(reading of values in the field, when devices are not
accessible)

Metering is our Business

Parameter Scheme
For DLMS devices we can retrieve various metering device objects as a
parameter scheme by reading the device itself. Proper instance map needs to
be selected first, since it contains descriptions of objects and their values.
Features:
Reading scheme from device
Writing scheme to device
Exporting scheme to command script
Comparing schemes

Metering is our Business

Parameter Scheme Comparing


Comparison results

Compare different
objects

Import/Update

Metering is our Business

Options when exporting NCS (from v. 2014)


Additional information (Title, Description, Icon image) can be provided
and later used in SEP2 MeterView Execute NCS control and in
Metrologue parameterization

Metering is our Business

Easy Execute commands (NCS)


Accessible from device context menu (from v. 2014)
Uses IEC1107 protocol

IEC1107 meters or
DLMS/COSEM meters in IEC1107 mode

Metering is our Business

Snapshots
Snapshot feature (from v. 2014) enables swift retrieval of all meter
contents in read-only mode (useful also for checking of content
differences at different times).
Comparison options:
compare snapshots,
compare snapshots with schemas,
Partial SNAPSHOT (in
compare snapshots with command scripts
the scheme context
menu)
Total
SNAPSHOT
(in the device
context menu)

Metering is our Business

Differences among editions Base edition 2014


Manage devices and groups
Read from device parameters, profiles, log book, events
Device communication log
License activation, HW lock and management
Use of local database (automatic upgrade from older
version)
Combine command scripts
Execute methods on DLMS/COSEM devices

19

Metering is our Business

Differences among editions Professional edition 2014


In addition to Base edition features:
Set/synchronize time
Parameter schema - save changes
Search for parameters
Print log book, load profile, data readout
Export to PDF, Excel, Word - log book, load profile, data
readout
Optional feature: read-only snapshots of device parameters
20

Metering is our Business

Differences among editions Enterprise edition 2014


In addition to Professional edition features (1/2):
Use remote communication (PSTN, GSM, GPRS, Modem,
TCP/IP ...)
Update device firmware
Execute command scripts
Parameter schema compare parameters (with print and
export to PDF, Excel, Word), import from command script
files, export to SEP2W reading definitions or command
scripts
21

Metering is our Business

Differences among editions Enterprise edition 2014


In addition to Professional edition features (2/2):
Parameter schema viewing and editing parameters in raw
mode
Export to SEP2W System - log book, load profile, data
readout
User and security management
Communication trace and analysis view

22

Metering is our Business

System requirements for SEP2 MeterView 2014


1+ GB RAM
Windows 7 or newer
.Net Framework 4.5 or newer comes
automatically with setup

23

Das könnte Ihnen auch gefallen