Beruflich Dokumente
Kultur Dokumente
ION6200
ION6200
PE86127
PowerLogic ION6200.
Applications
Main characteristics
High visibility front panel display
The ION6200 displays all basic power parameters on a bright LED display with
twelve 19 mm high digits.
Megawatt option
The Megawatt option displays all power and energy values in millions (e.g.
megawatts) and volts in thousands (kilovolts), using a different front panel faceplate
than the standard meter, with labels for kV, MW, MVA, Mvar, MWh, MVAh and Mvarh.
Complete communications
Optional RS 485 port with standard Modbus RTU and ION compatible protocol; data
rates from 1,200 bps to 19,200 bps.
Modularity
The ION6200s modular construction allows for simple retrofit, allowing you to save
money by making a low initial investment that can be upgraded to meet future needs.
Easy to use
Fast setup via display or software; free configuration software; and a bright, easy to
read LED display make the ION6200 easy to use.
Accuracy certification
This meter offers IEC 60687 Class 0.5S accuracy for use as a tariff meter.
Revenue metering option
Provides power and energy measurements that are certified for revenue metering
and protection against unauthorized alteration of these measured quantities.
Flexible architecture
Patented ION technology provides a modular, flexible architecture that offers
extensive user programmability. It uniquely addresses complex monitoring and
control applications, and adapts to changing needs, avoiding obsolescence.
Multiple installation options
Supports Direct 4-wire Wye, 3-wire Wye, 3-wire Delta, Direct Delta and
single phase configurations
Part numbers
PowerLogic ION6200
See page 56 for part number descriptions and options.
2013
M6200
ION6200
Functions and characteristics (cont.)
PE86079
Selection guide
1
General
(N)
(P)
(R)
0.3%
0.5%
64
0.3%
0.5%
64
0.3%
0.5%
64
b
b
b
b
b
b
b
b
b
Total
per phase
Total
per phase
Total
per phase
Energy values
Active energy(3)
Reactive, apparent energy(3)
1
2
3
4
5
6
Current inputs
COM1 port
Power supply
D2: Form A digital out
Voltage inputs
D1: Form A digital out
b
b
b
b
b
b
b
b
b
b
400/690
400/690
400/690
b
b
b
b
b
b
b
b
b
Communication
RS-485 port
ION compatibility
Modbus RTU protocol
Current, voltage
b
b
Demand values
Current
Active power
b
b
2013
ION6200
Functions and characteristics (cont.)
PE86127
Electrical characteristics
Type of measurement
Measurement
accuracy
Current
Voltage
Power
5% of full scale:
< 5% of full scale
I4 derivation
Frequency
Power factor
Energy
Harmonic distortion
PowerLogic ION6200.
Power supply
Permissible overload
Starting current
Burden
Inputs
Dielectric withstand
AC
DC
Input/outputs
Digital outputs
RS-485 port
Mechanical characteristics
Weight
IP degree of protection (IEC 60529)
Dimensions
Environmental conditions
Operating temperature
Storage temperature
Humidity rating
Pollution degree
Installation category
Electromagnetic compatibility
Electrostatic discharge
Immunity to radiated fields
Immunity to fast transients
Surge immunity
Conducted immunity
Electromagnetic compatibility for industrial
environments
Safety
Communications
RS 485 port
Display characteristics
19 mm high digits
Displays all basic power parameters
Easy setup for common configuration
parameters
Password protection on setup parameters
Password protection for demand reset
(1) The meter inputs can be used with PTs that have secondaries rated between 50 V ac and
347 V ac +25%. Use CTs that are compliant with the electrical safety code in your region.
2013
ION6200
Functions and characteristics (cont.)
Part Numbers
Item
Description
Model
M6200
Form Factor
A0
R1
PE86080
Code
R2
R3
T1
3
4
6
7
Current Inputs
Voltage Inputs
System Frequency
Communications
A
0
0
Z0
A0
I/O
A
B
Security
0
2
3
4
10 Measurement
package
N
P
R
PE86081
Power supply
Power supply
2013
ION6200
Functions and characteristics (cont.)
PE86082
MegaWatt options
MegaWatt option on meter base with integrated display. Not available for
RMICAN or RMICAN-sealed meters
M0
MegaWatt option on Transducer model with DIN rail mount, Remote Display N1
and 14-ft cable (RJ11, 6 conductor, 26 gauge). Not available with Security
options RMICAN or RMICAN-SEAL.
MegaWatt option on Transducer model with DIN rail mount, Remote Display N2
and 6-ft cable (RJ11, 6 conductor, 26 gauge). Not available with Security
options RMICAN or RMICAN-SEAL.
MegaWatt option on Transducer model with DIN rail mount, Remote Display N3
and 30-ft cable (RJ11, 6 conductor, 26 gauge). Not available with Security
options RMICAN or RMICAN-SEAL.
PE86083
Options card
1
2
3
4
5
6
7
8
9
10
11
12
Standard Measurements
Enhanced Package #1
Enhanced Package #2
Standard Measurements, two pulse outputs
Enhanced Package #1, two pulse outputs
Enhanced Package #2, two pulse outputs
Standard Measurements, RS-485
Enhanced Package #1, RS-485
Enhanced Package #2, RS-485
Standard Measurements, two pulse outputs, RS-485
Enhanced Package #1, two pulse outputs, RS-485
Enhanced Package #2, two pulse outputs, RS-485
Z0A0N
Z0A0P
Z0A0R
Z0B0N
Z0B0P
Z0B0R
A0A0N
A0A0P
A0A0R
A0B0N
A0B0P
A0B0R
Cable Length
Standard Display
MegaWatt option - for use with Transducer meter base with
MegaWatt option
No Cable
14-ft cable for connecting Remote Display Unit to the
ION6200 Transducer meter base
6-ft cable for connecting Remote Display Unit to the
ION6200 Transducer meter base
30-ft cable for connecting Remote Display Unit to the
ION6200 Transducer meter base
M620D
R
N
0
1
2
3
2013
P620C1
P620C2
P620C3
ION6200
Dimensions and connections
PE86085
PE86084
PE86087
PE86086
PE86085
2013
ION6200
Dimensions and connections (cont.)
PE86089
101.6 mm
diameter
screw &
washer
85.7 mm
mounting
surface
92 mm x 92 mm
2013
As standards, specifications and designs develop from time to time, please ask
for confirmation of the information given in this document.
PLSED306008EN
07-2013