Sie sind auf Seite 1von 25

Spacing for a lateral support for a beam shall not exceed

_______times the least width b of compression flange or face.


(NSCP 410.5.10)

40
50
60
30

For a rectangular reinforced concrete compression member, it shall


be permitted to take the radius of gyration equal to _______times
the overall dimension of the direction of stability is being
considered. (NSCP 410.12.20)

0.30
0.45
0.50
0.75

For members whose design is based on compressive force, the


slenderness ratio kL/r preferably should not exceed ________?
(NSCP 502.8.1)

300
250
200
350

For members whose design is based on tensile force, the


slenderness ratio L/r preferably should not exceed _________.

200
300
250
350

For pin connected members, the allowable stress on the net area of
the pinhole for pin connected members is _________.
(NSCP 504.4.1.1)

0.60 Fy
0.50 Fy
0.45 Fy
0.40 Fy

Other than pin connected members, the allowable tensile stress


shall not exceed _______ on the gross area. (NSCP 504.2.1)

0.60 Fy
0.45 Fy
0.33 Fy
0.66 Fy

For pin connected plates, the minimum net area beyond the pinhole
parallel to the axis of the member shall not be less than _______of
the net area across the pinhole. (NSCP 504.4.2.1)

3/4
2/3
3/5
1/3

For pin connected members in which the pin is expected to provide


for relative movement between connected parts while under full
load, the diameter of the pinhole shall not be more than ______mm
greater than the diameter of the pin. (NSCP 504.4.2.3)

1 mm
0.5 mm
0.80 mm
2 mm

The maximum longitudinal spacing of bolts, nuts and intermittent


welds correctly two rolled shapes in contact for a built up section
shall not exceed ________. (NSCP 505.5.4)

700 mm
500 mm
600 mm
400 mm

The ratio L/r for lacing bars arranged in single system shall not
exceed ________. (NSCP 505.5.80)

140 mm
200 mm
250 mm
100 mm

The ratio L/r for lacing bars arranged in double system shall not
exceed ________.

140 mm
200 mm
250 mm
100 mm

For members bent about their strong or weak axes, members with
compact sections where the flanges continuously connected to web
the allowable bending stress is _________. (NSCP 506.4.1.1)

0.75 Fy
0.60 Fy
0.45 Fy
0.66 Fy

For box type and tabular textural members that meet the non
compact section requirements of section 502.6, the allowable
bending stress is ________. (NSCP 506.4.1.1)

0.75 Fy
0.60 Fy
0.45 Fy
0.66 Fy

Bolts and rivets connecting stiffness to the girder web shall be


spaced not more than ______mm on centers. (NSCP 507.5.3)

300 mm
400 mm
350 mm
250 mm

Ira composite beam section, the actual section modulus of the


transformed composite section shall be used in calculating the
concrete flexural compressed stress and for construction without
temporary shores, this stress shall be based upon loading applied
after the concrete has reached _____% of its required strength.

50%
60%
80%
75%

Shear connectors shall have at least ________mm of lateral


concrete covering. (NSCP 509.5.8)

50 mm
100 mm
25 mm
40 mm

The minimum center to center spacing of stud connectors along the


longitudinal axis of supporting composite beam is ____________.
(NSCP 509.5.8)

6 diameter of connector
10 diameter of connector
12 diameter of connector
5 diameter of connector

The maximum center to center spacing of stud connectors along


the longitudinal axis of supporting composite beam is
____________. (NSCP 509.5.8)

8 diameter of connector
6 diameter of connector
5 diameter of connector
10 diameter of connector

Connections carrying calculated stresses, except for lacing, sag


bars and girts, shall be designed to support not less than
________Kn of force. (NSCP 510.10.61)

30
50
26.70
35

The connections at ends of tension or compression members in


trusses shall develop the force due to the design load, but no less
than _______% at the effective strength of the member unless a
smaller percentage is justified by engineering analysis that
considers other factors including handling, shipping and erection.
(NSCP 510.2.5.1)

50
70
65
100

When formed steel decking is a part of the composite beam, the


spacing of stud shear connector along the length of the supporting
beam or girder shall not exceed _______mm. (NSCP 509.6.1.2)

800
750
900
1000

The minimum sizes of filler weld for plates with thickness greater
than 20mm is ________. (NSCP 510.3.3.2)

10
8
15
20

The minimum sizes of filler weld for plates with thickness 6mm is
________? (NSCP 510.3.3.2)

3 mm
6 mm
8 mm
10 mm

The minimum sizes of filler weld for plates with thickness over
12mm to 20mm is ________? (NSCP 510.3.3.2)

8 mm
10 mm
6 mm
5 mm

The minimum sizes of filler weld for plates with thickness over
12mm to 20mm is ________? (NSCP 510.3.3.2)

8 mm
10 mm
6 mm
5 mm