Beruflich Dokumente
Kultur Dokumente
HIS Heat Exchanger Training Apparatus (Model: HE 158C) is a bench type unit designed to allow
students to get familiarised with different kinds of heat exchangers and to collect the necessary experimental
data for the calculation of heat loss, heat transfer coefficient, log mean temperature difference, etc. Student
will also be able to study the effect of flow rate on the heat transfer rate. Later, students may use this knowledge for
designing complex industrial heat exchangers.
Rev1.0 17/06/2011
EXPERIMENTAL CAPABILITIES
Energy balance determination
Temperature profiles in co-current and countercurrent flow
Log mean temperature difference
Heat transfer coefficient
Flow rate effects on heat transfer rate
Heat loss estimation
Relationship between Nusselt (Nu) and Reynold
(Re) numbers
SPECIFICATIONS:
Bench
Epoxy coated mobile steel bench with lockable swivel
castors.
Shell & Tube Heat Exchanger
Shell
: I.D. = 85 mm
Length = 500 mm
Material = borosilicate glass
Tubes
: O.D. = 9.53 mm
I.D. = 7.75 mm
Length = 500 mm
Tube count = 10 (single pass)
Tube pitch = 18 mm (triangle)
Baffle = 8
Baffle cut = 20%
Material = stainless steel 316L
Exchange area : 0.15 m2 (approx.)
Concentric (Double Pipe) Heat Exchanger
Shell
: I.D. = 85 mm
Length = 500 mm
Material = borosilicate glass
Tube
: O.D. = 33.4 mm
I.D. = 26.64 mm
Length = 500 mm
Material = stainless steel 316L
Exchange area : 0.05 m2 (approx.)
Spiral Heat Exchanger
Shell
: I.D. = 85 mm
Length = 500 mm
Material = borosilicate glass
Coil
: O.D. = 9.53 mm
I.D. = 7.05 mm
Length = 5 m
Material = stainless steel 316L
Exchange area : 0.15 m2 (approx.)
SOLTEQ
SOLTEQ
:
:
:
:
50 L
Stainless steel
Inlet/outlet/drain
11.5 kW for hot tank with temperature
control
Pumps
Type
Capacity
Head
Electrical
:
:
:
:
Instrumentations
Flow meters : 0 to 10 LPM (cold water)
0 to 10 LPM (hot water)
Temperatures : 0 to 100 C
Manometer
: 0 to 50 cm of water
Temperature sensor and controller
Control Panel
Temperature controller for heater input to maintain
the hot water temperature and prevent over heating.
On/off buttons for pumps and heater.
OPTIONAL ITEMS
- EI
DIGITAL INSTRUMENTATIONS
i) 8 units of digital indicators
ii) 4 units of temperature sensors c/w transmitter
iii) 2 units of electronic flow meters
iv) 2 units of differential pressure transmitters
Rev1.0 17/06/2011
SOLTEQ
i)
ii)
iii)
iv)
- CAL
SOLCAL COMPUTER
SOFTWARE
AIDED
OVERALL DIMENSIONS
Height : 1.50 m
Width : 1.52 m
Depth : 0.91 m
LEARNING
MANUAL
Shell & Tube Heat Exchanger with Variable Hot Water Flow Rate
1200
Overall heat transfer coeff. (W/m2.K)
SOLTEQ
-DAS
SOLDAS DATA ACQUISITION SYSTEM
1000
800
600
400
200
0
0
2,000
4,000
6,000
8,000
10,000
12,000
14,000
16,000
Rev1.0 17/06/2011
SOLTEQ
AGENT:
MSC- Status
BUATAN MALAYSIA
Company
Rev1.0 17/06/2011