Sie sind auf Seite 1von 1

Orifice Plate Flowmeter

Rosemount Inc.

APPLICATION AND CONFIGURATION DATA SHEET (Required with order)


Customer:
Phone/Fax #
Contact Name:
SST Tag #:
Software Tag#:

P.O.#

Transmitter Information:
Descriptor:
(21 characters maximum) Message:
(8 characters maximum) Date:

Primary Element Info:


Model No:
Product Type:
Bore Size :
Calibrated Range:

1495PC060A3SC03745BCFJQC7Q8

D and D/2 tapping


95.114 mm
4mA = 0
20mA = 30.83 psi

Input Data:
Fluid Type:
Operating Pressure:
Operating Temperature:
Absolute Viscosity:
Isentropic Exponent:
Operating Compressibility:
Operating Density:
Max Pressure @ Design Temperature:
Max Temperature:
Minimum:
Normal:
Maximum:
Full Scale/Design:

Steam
15.878 bar-g
204.00 C
0.01585 cP
1.31145

Fluid Description:
Base Pressure:
Base Temperature:
Base Compressibility:
Base Density:
Atmospheric Pressure:

8.522317 kg/m3
43.016 bar-g
454.44 C

14.696 psia
225 C

Flow Rates

Temperatures

5.000
25.000
30.000
32.000

190.00
204.00
220.00
225.00

Ton(M)/hr
Ton(M)/hr
Ton(M)/hr
Ton(M)/hr

Based on Saturated Temperature

Pressures
10
15.8779913
17
20.000

C
C
C
C

bar-g
bar-g
bar-g
bar-g

Pipe Information:
Line Size/Schedule: 6 inches (DN150)
OR
146.329 mm

80 No Defaults

Wall Thickness:

10.973 mm

Measured I.D (recommended for Annubar - required for manufacture)

Materials of Construction
Pipe Material:
Primary Element Material:

Calculated Data:

Carbon Steel
316/316L SST
(Calculation Performed at Normal Conditions)

Generated DP:
at Min Flow:
at Normal Flow:
at Max Flow:
at Full Scale Flow:
Minimum Accurate (Flow):
Structural Limit (DP):
Structural Limit (Flow):
Velocity at Max Flow:

Permanent Pressure Loss:


0.753
18.820
27.101
30.835
1.600

psi

10.752 psi
15.485 psi

at Normal Flow:
at Maximum Flow:

psi
psi
psi
Ton(M)/hr
psi
Ton(M)/hr

Bore Reynolds Number (Normal):


Pipe Reynolds Number (Normal):
Flow Coefficient:

5845390
3803145
0.6070

58.144 m/sec
Thermal Expansion Factor:
Gas Expansion Factor:

Natural Gas Worksheet


Detail Characterization Method (AGA8 1992)
CH4
Methane mole %
N2
Nitrogen mole %
CO2
Carbon Dioxide mole %
C2H6
Ethane mole %
C3H8
Propane mole %
H2O
Water mole %
H2S
Hydrogen Sulfide mole %
H2
CO
O2
C4H10
C4H10
C5H12
C5H12

Mole

Hydrogen mole %
Carbon Monoxide mole %
Oxygen mole %
I-Butane mole %
n-Butane mole %
I-Pentane mole %
n-Pentane mole %

C6H14
n-Hexane mole %
C7H18
n-Heptane mole %
C8H18
n-Octane mole %
C9H20
n-Nonane mole %
C10H22
n-Decane mole %
He
Helium mole %
Ar
Argon mole %
(1) The summation if I-Butane and n-Butane cannot exceed 6 percent
(2) The summation of I-Pentane and n-Pentane cannot exceed 4 percent

%
%
%
%
%
%
%

Valid Range
0-100 percent
0-100 percent
0-100 percent
0-100 percent
0-12 percent
0-Dew Point
0-100 percent

%
%
%
%
%
%
%

0-100 percent
0-3.0 percent
0-21 percent
0-6 percent (1)
0-6 percent (1)
0-4 percent (2)
0-4 percent (2)

%
%
%
%
%
%
%

0-Dew Point
0-Dew Point
0-Dew Point
0-Dew Point
0-Dew Point
0-3.0 percent
0-1.0 percent

* Not available for Annubars


** Indicates Default Value

For Rosemount Internal Use Only


Sales Order:
Cont. Admin.:

Line Item#:

ID #:

Salesperson:

NOTES

This report is provided according to the terms and conditions of the Instrument Toolkit(TM) End-Use Customer License Agreement.
Version: 3.0 (Build167C)
Printed:
11/19/2014 11:50 AM

1.0000
0.9748