Sie sind auf Seite 1von 6

Deployment Team PDF

Friday, October 23, 2009


10:52 AM
 

CONTENT
 
 
1. Server Details.
 
2. Windows Installation.
 
3. Software Installation.
 
4. Linux NMS & SS7 Installation
 
 
Server Details
 
1. IBM x346 Server:
 
 Dimension : 44.4 cm x 69.8 cm x 8.5
cm
 Power : 625W or 4AMP by
Single RPS
 Installation Required Space : 2U
 HDD Size : 73GB/146GB/300GB
 RAM Size : Upto 16GB
 Rack Kit : Available
 
 
 
2. IBM x226 Server:
 
 Dimension : 6.5 cm x 26 cm x 18.4 cm
 Power : 680W or 5AMP by
Single RPS
 Installation Required Space : 4U
 HDD Size : 73GB/146GB/300GB
 RAM Size : Upto 16GB
 Rack Kit : Available
 
 
 
3. IBM x3400 Server:
 
 Dimension : 21.6 cm x 70.1 cm x 44
cm
 Power : 670W or 5AMP by
Single RPS
 Installation Required Space : 5U
 HDD Size : 73GB/146GB/300GB
 RAM Size : Upto 32GB
 Rack Kit : Available
 
 
4. HP DL 360 G5 Server:
 
 Dimension : 4.32 cm x 42.62 cm x
69.22 cm
 Power : 700W or 6AMP by
Single RPS
 Installation Required Space : 2U
 HDD Size : 146GB
 RAM Size : Upto 32GB
 Rack Kit : Available
 
 
5. HP DL 380 G5 Server:
 
 Dimension : 8.59 cm x 44.54 cm x
66.07 cm
 Power : 700W or 6AMP by
Single RPS
 Installation Required Space : 2U
 HDD Size : 146GB
 RAM Size : Upto 32GB
 Rack Kit : Available

 
6. HP ML 350 G5 Server:
 
 Dimension : 8.7 inc x 25.2 inc x 18.4
inc
 Power : 1000W or 8AMP by
Single RPS
 Installation Required Space : 5U
 HDD Size : 73GB/146GB/300GB
 RAM Size : Upto 16GB
 Rack Kit : Available
 
 
Windows Installation
 
 After installing Windows do the following things:
 
 Rename the Computer Name.
 Double Click on the Time in the Taskbar, then click on the Internet Time
and uncheck the BOX.
 Go to the MY COMPUTER Properties and click on the Advance and go to
the Performance and check on the box "Adjust for Best Performance".
 Go to the Add/Remove Window Component and remove the Games,
Window Media Player, Outlook Express, MSN Explorer & Windows
Messenger.
 While updating Windows kindly do not install the Windows Search 4.0,
Internet Explore 8, Window Media Player Updates, Outlook Express
Updates.
 
 
 
software Installation
 
1. 7 ZIP: Install the Software on the By Default Path. After installing, Click on the Start ----
Programs ---- 7 Zip ---- 7 ZIP File Manager (Double Click) ----- Go to the Tools ----- Select All the
Associate File ----- then Go to the Plugins ------ Uncheck the Tick from Test Archive.
 
2. APACHE: Double Click on the EXE ----- Accept the Agreement ----- Write "localhost" in
Network Domain & Server Name ----- Write "deployment@one97.net" in Administrator's Email
Address. After that choose Custom and change the installation path from default into c:\ drive.
 
3. CLIP MANAGER PACKAGE: Install the Software on the By Default Path.
 
4. CONTARRA 2007: Open the txt file first and copy the password then double click on the EXE.
Paste the PASSWORD in the space and after that install the Software on the By Default Path with
Complete Package. After that it will ask you to create shortcut of the Contarra Folder ----- Click
Yes.
 
5. DB BROWSER PACKAGE: Install the Software on the By Default Path.
 
6. MYSQL: Double Click on the EXE ------ Choose the Custom Path ------- Change the Installation
Path into C:\MYSQL\ and install the software ----- Choose "Skip Sign Up" -------- Click Finish
------- Configuration Wizard will come (Then choose the Options as mentioned) ------- Next
------- Detailed Configuration ------ Server Machine -------- Multifunctional Database -------- Next
-------- Online Transaction processing (OLTP) ----- Next ------ Best Support for Multilingualism
------- Select "Include Bin Directory in Windows PATH" ------- Select "Create an anonymous
account" ------- then uncheck the "Modify Security Settings" -------- Execute.
 
7. NMS 8.1: Double Click on the INSTALL.BAT file ------ Accept the agreement ------ Next -------
Choose Select All Countries ------- then Select "INDIA" ------ Next ------ Install the Software on the
By Default Path -------- After installation a window will come for Hot Swap Functionality ------
Choose NO ------ then again choose NO ------ then again Choose NO ------ then Click Finish.
 
8. OPENSSH: Install the Software on the By Default Path ------ in Last a Window will open Click
OK ------ FINISH -------- then Open the Command Prompt ----- go at the following Path ------
C:\Program Files\OPENSSSH Guide in the Program Files. Paste the following command in the
CMD and press Enter:
1. mkgroup -l >> ..\etc\group
2. mkpasswd -l >> ..\etc\passwd
 
Then you can Start the SSH Services in the Services file.
 
9. PERL: Open the Folder ------ Click on Perl Setup ------ Double Click on the EXE and choose the
Installation Path from D:\Perl into C:\Perl ------ Finish.
 
10. PERL PACKAGES: After installing the Perl ------ Open the file and Path is E:\ New Server
Software\Perl Packages\Extra Packages\ Instruction Sheet For Installing Extra Perl
Packages.txt ------ then Open the Command Prompt ------ then go in the following path "E:\ New
Server Software\Perl Packages\Extra Packages" ------ then write "ppm" and press Enter ------
now copy command one by one from notepad and paste it in the CMD and press ENTER.
 
11. PHP: Copy the php-4.3.10RC1-Win32 folder from E:\New Server Software\PHP
Software\php-4.3.10RC1-Win32 and paste it in the C:\ Drive ---- then rename it to "php" -----
then open the folder and rename the file php.ini.recommended into "php.ini" ----- Copy the
php.ini file and paste it into C:\Windows & C:\Windows\System32 Folder -------- then again
come in the PHP Folder and copy all the dll's and also paste into C:\Windows &
C:\Windows\System32 Folder ------- then again come in the PHP Folder and click on the sapi
folder ----- the copy php4apache2.dll ------ Paste in the C:\php\ ------ again go to the Path E:\New
Server Software\PHP Software\php-4.3.10RC1-Win32 --------- copy the httpd.conf file
----------- paste in the C:\Apache2\conf ----------- Restart the Apache Services.
 
12. PASTE IN D DRIVE: Copy the sms_apps folder and paste into D Drive
 
13. RAID MANAGER X3400: Install the Software on the By Default Path.
 
14. SS7 4.3: Install the Complete Software on the By Default Path.
 
15. ULTRA VNC: Install the Software on the By Default Path ----- A window will come for
configuration ------ Click OK ------ then do the following thing:
1. Choose ACCEPT
2. Choose LOCK WORKSTATION (WIN2K)
3. Change VNC Password into echoes
4. Uncheck the User Impersonation (for Service Only)
5. Allow LoopBack Connection.
 
 
16. MBSASetup-EN.msi: Install the Software on the By Default Path.
 
17. MyODBC-3.51.11-2-win.exe: Install the Software on the By Default Path.
 
18. Sentinel7.exe: Install the Software on the By Default Path.
 
19. JRE: Install the Software on the By Default Path.
 
20. APACHE TOMCAT 6.0.20: Install the Software on the By Default Path. Note: If anyone will
say to install the TOMCAT kindly confirm the installation PATH too.
 
LINUX NMS & SS7 Installation
 
 
 Check the mention below Table for the RHEL supports NMS 2005_SP5 or
NMS 8_1

S.No NMS Version RHEL 4 Update 4 RHEL 4 Update 5 RHEL 4 Update 6 RHEL 4 Updat
1 2005_SP5 Supported Supported Not Supported Not Supported
2 8_1 Not Supported Not Supported Supported Supported
 
 Installation of NMS 2005_SP5/8_1:
 
 Copy or FTP NMS in /opt/dump/nms
 Unzip the tar file by writing following command
 zcat <file name.tar.Z> | tar xf –
iii. To install the NMS write:
 ./install
iv. After reboot the Server
v. To set the environment variables, run the following scripts:
 /opt/nms/ctaccess/cfg/nms_profile.sh
vi. To Start the NMS Services:
 cd /etc/init.d/
 service nmsctdaemon start
 
 
 
2. Installation of SS7 4.3:
 
i. Copy or FTP SS7 in /opt/dump/ss7
ii. Unzip the tar file by writing following command
 gzip -d filename.tar.gz
 tar -xvf filename.tar
iii. To install the SS7 write:
 ./ss7_install
iv. After reboot the Server
v. To set the environment variables, write the scripts:
PATH=/opt/nmstx/bin:$PATH
export PATH
LD_LIBRARY_PATH=/opt/nmstx/lib:$LD_LIBRARY_PATH
export LD_LIBRARY_PATH
 cd /etc/ (Go to the path)
 vi bashrc (write the above script in the file after fi)
 vi profile (write the above script in the file after fi)
 
 Configuration of CG6565 Card:
 
i. To check the NMS Card:
 cd /opt/nms/bin/
 pciscan (run this command to check the NMS Card)
ii. To generate the sample.cfg file and copy its data in the oamsys.cfg file
 oamgen (run this command to generate sample.cfg file)
 cp sample.cfg /opt/nms/oam/cfg/oamsys.cfg (copy this sample file
data in the oamsys file)
iii. To change the NMS CG6565 Board No:
 cd /opt/nms/oam/cfg/ (Go in the directory)
 vi oamsys.cfg (To make change in the oamsys.cfg file)
 change the Number from 1 into 0
 Do not change the BUS & Slot No
iv. After that copy the following parameters in the following path:
 cg6565nocc.cfg into /opt/nms/cg/cfg/ (Overwrite the old file)
 swish.swf into /opt/nms/bin (Swish file must be having Signaling
Link on the 16th Time Slot)
 
 
4. Configuration of CG6565 Card:
 
i. To configure the SS7 Card:
 cd /opt/nmstx/bin/ (go in this path)
 ./txcpcfg (to chk the BUS No, Slot No & Sequence No written there
or not, if not then do the needful)
 ./txcpcfg <bus no> <slot no> <sequence no>
ii. After that copy the following parameters in the following path:
 ss7load into /opt/nmstx/bin/ (Overwrite the old file)
 ISUPcp1.cfg, MTP3cp1.cfg & txcfg1.txt into
/opt/nmstx/etc/standalone/itu (ISUPcp1 & MTP3cp1 file name is
like that only not isupcp1 or mtp3cp1)
iii. To run the SS7 Load file:
 /opt/nmstx/bin/
 ./ss7load or ss7load
 ./txalarm or txalarm