Beruflich Dokumente
Kultur Dokumente
LS Inverter Series
iE5 / iC5 / iG5A / iS5 / iS7 / iH / iP5A / iV5
Drive Solution
Performance
iV5
iS7
iP5A
3 phase
iS5
iH
iG5A
iE5
kW
(HP)
iG5A
1 phase
iC5
iE5
0.1
(1/8)
kW
0.4
(1/2)
0.751.5 2.2
(1) (2) (3)
5.5
(7.5)
22
(30)
30
(40)
75
(100)
160
(250)
220
(300)
Contents
iE5
iC5
iG5A
iS5
iS7
iH
4
5
6
7
8
9
iP5A
iV5
Comparison
Option list
Dynamic Braking Unit list
External resistor list
LS Inverter Series
10
11
12
14
15
15
iE5
V/f control
Compact size: 6812885mm (2.753.3 inch)
0.1 ~ 200Hz frequency output
1 ~ 10kHz carrier frequency
Fault history: Last 3 faults
IP20 enclosure
RS485 (LS Bus / Modbus RTU) communication (Built-in option)
DC Injection braking
Selectable manual/automatic torque boost
Selectable PNP/NPN input signal
PI control
Up-Down & 3-Wire operation
Automatic restart after instantaneous power failure
Built-in potentiometer
Monitoring & commissioning PC based software tool (Drive View)
Parameter copy unit
Model Number
SV
LS inverter brand
004
Motor rating
001: 0.1kW ~ 004: 0.4kW
iE5
Series name
iE5
Symbol
Input rating
1
Single-phase, 200~230V
2
Three-phase, 200~230V
Symbol
Communication
None
Not available
C
RS485 (LS Bus / Modbus RTU)
General specification
Model number: SV
iE5-
Motor rating
Output rating
Capacity
Output signal
Protection
002-2
[HP]
0.13
0.25
0.5
0.13
0.25
0.5
[kW]
0.1
0.2
0.4
0.1
0.2
0.4
0.6
0.95
0.3
0.6
1.14
0.8
1.4
2.5
0.8
1.6
3.0
Voltage
[V]
Voltage
Control method
[Hz]
[V]
[Hz]
50 ~ 60Hz (5%)
[A]
2.0
3.5
5.5
1.2
2.0
3.5
[kg]
0.44
0.46
1.68
0.43
0.45
0.67
Frequency accuracy
Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve
Overload capacity
Torque boost
Keypad Display
Operation method
Frequency setting
Operation function
Multi-function terminal
(P1 ~ P5)
5 points (programmable)
Multi-function relay
Fault output & inverter status output (N.O., N.C.) Less than AC 250V, 0.3A / Less than DC 30V 1A
Analog output
Inverter trip
Over voltage / Low voltage / Over current / Ground fault / Inverter overload / Overload trip / Inverter overheat /
Condenser overload / Output phase open / Frequency command loss / Hardware fault / etc.
Inverter alarm
Enclosure
Option
004-2
0.3
Current
Input signal
001-2
[A]
Weight
Operation
004-1
[kVA]
Frequency
Control Spec
002-1
Current
Frequency
Input rating
001-1
Stall prevention
IP20
iC5
Model Number
SV
LS inverter brand
004
Motor rating
004: 0.4kW ~ 022: 2.2kW
iC5
Series name
iC5
Symbol
Input rating
1
Single-phase, 200~230V
Symbol
None
F
Filter
Not available
EMC filter
General specification
Model number: SV
iC5-
Motor rating
Output rating
Capacity
Output signal
[kW]
0.4
0.75
1.5
2.2
1.9
4.5
2.5
12
Voltage
[V]
Voltage
[Hz]
[V]
[Hz]
[A]
5.5
9.2
16
21.6
[kg]
0.87
0.89
1.79
1.85
Control method
Frequency accuracy
Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve
Overload capacity
Torque boost
Keypad Display
Operation method
Frequency setting
Operation function
Multi-function terminal
(P1 ~ P5)
5 points (programmable)
Multi-function relay
Multi-function open collector
Analog output
Protection
022-1
0.95
Current
Input signal
[A]
Weight
Operation
015-1
[kVA]
Frequency
Control Spec
008-1
0.5
Current
Frequency
Input rating
004-1
[HP]
Inverter trip
Inverter alarm
Enclosure
Option
LS Inverter Series
iG5A
Model Number
SV
LS inverter brand
015
iG5A
Motor rating
004: 0.4kW ~ 220: 22kW
Series name
iG5A
Symbol
Input rating
1
Single-phase, 200 ~ 230V
2
Three-phase, 200 ~ 230V
4
Three-phase, 380 ~ 480V
General specification
Model number: SV
iG5A-1
004
Motor rating
Output rating
Input rating
[HP]
[kW]
[kVA]
[A]
[V]
[Hz]
[V]
[Hz]
[kg]
Capacity
Current
Voltage
Frequency
Voltage
Frequency
Weight
Model number: SV
iG5A-2
Motor rating
Output rating
Input rating
Capacity
Current
Voltage
Frequency
Voltage
Frequency
Weight
Model number: SV
Output rating
Input rating
Capacity
Current
Voltage
Frequency
Voltage
Frequency
Weight
Control Spec
Operation
Input signal
Output signal
Protection
2
1.5
3.0
8
1.12
1.84
022
037
040
055
075
110
150
185
220
5
3.7
6.1
16
5.4
4.0
6.5
17
7.5
5.5
9.1
24
10
7.5
12.2
32
15
11
17.5
46
20
15
22.9
60
25
18.5
28.2
74
30
22
33.5
88
1.89
1.89
3.66
3.66
9.00
9.00
13.3
13.3
022
037
040
055
075
110
150
185
220
0.5
1
2
3
0.4
0.75
1.5
2.2
0.95
1.9
3
4.5
1.25
2.5
4
6
Three-phase 380 ~ 480V
0.1 ~ 400Hz
Three-phase 380 ~ 480V (+10%, -15%)
50 ~ 60Hz (5%)
0.76
0.77
1.12
1.84
5
3.7
6.1
8
5.4
4.0
6.5
9
7.5
5.5
9.1
12
10
7.5
12.2
16
15
11
18.3
24
20
15
22.9
30
25
18.5
29.7
39
30
22
34.3
45
1.89
1.89
3.66
3.66
9.00
9.00
13.3
13.3
008
015
015
1
0.75
1.9
5
0.5
1
2
3
0.4
0.75
1.5
2.2
0.95
1.9
3
4.5
2.5
5
8
12
Three-phase 200 ~ 230V
0.1 ~ 400Hz
Three-phase 200 ~ 230V (+10%, -15%)
50 ~ 60Hz (5%)
0.76
0.77
1.12
1.84
004
[HP]
[kW]
[kVA]
[A]
[V]
[Hz]
[V]
[Hz]
[kg]
008
008
015
Control method
Speed reference resolution
Frequency accuracy
V/f curve
Overload capacity
Torque boost
Keypad Display
Operation method
Frequency setting
Operation function
Multi-function terminal
(P1 ~ P8)
Multi-function relay
Multi-function open collector
Analog output
Inverter trip
Over voltage / Low voltage / Over current / Over Current 2 / Ground fault / Inverter overheat / Output phase open /
OInverter overload / Overload trip / Communication error / Frequency command loss / Hardware fault / Fan fault / Brake error / etc.
Stall prevention, Overload
Inverter alarm
Enclosure
Option
Others
004
[HP]
[kW]
[kVA]
[A]
[V]
[Hz]
[V]
[Hz]
[kg]
iG5A-4
Motor rating
0.5
0.4
0.95
2.5
Three-phase 200 ~ 230V
0.1 ~ 400Hz
Single-phase 200 ~ 230V (+10%, -15%)
50 ~ 60Hz (5%)
0.77
iS5
Model Number
SV
LS inverter brand
008
iS5
Motor rating
008: 0.75kW ~ 750: 75kW
Series name
iS5
Symbol
Input rating
2
Three-phase, 200 ~ 230V
4
Three-phase, 380 ~ 480V
Symbol Loader
None
Loader
N
Non Loader
Symbol UL certification
O
Open type
E
Enclosed type 1
380V
Symbol
Rated voltage
None 200~230V or 380~480V
**** 380V, 440V, 460V, 480V
General specification
Model number: SV
iS5-2
Motor rating
Output rating
Input rating
Capacity
Current
Voltage
Frequency
Voltage
Frequency
Weight
Model number: SV
iS5-4
Motor rating
Output rating
Input rating
Capacity
Current
Voltage
Frequency
Voltage
Frequency
Weight
Control Spec
Operation
Input signal
Output signal
Control method
Speed reference resolution
Frequency accuracy
V/f curve
Overload capacity
Torque boost
Keypad Display
Operation method
Frequency setting
Operation function
Sart signal
Multi-step
Multi-step Accel/Decel time
Emergency stop
JOG
Auto operation
Fault reset
Operating status
Fault output
Indicator
Protection
Inverter trip
Inverter alarm
Enclosure
Option
Others
008
[HP]
[kW]
[kVA]
[A]
[V]
[Hz]
[V]
[Hz]
[kg]
008
[HP]
[kW]
[kVA]
[A]
[V]
[Hz]
[V]
[Hz]
[kg]
015
022
037
055
075
110
1
2
3
5
7.5
10
15
0.75
1.5
2.2
3.7
5.5
7.5
11
1.9
3
4.5
6.1
9.1
12.2
17.5
5
8
12
16
24
32
46
Three-phase 200 ~ 230V
0.1 ~ 400Hz (Sensorless control: 0.1~300Hz, Sensored control: 0.1~120Hz)
Three-phase 200 ~ 230V (10%)
50 ~ 60Hz (5%)
4.6
4.6
4.8
4.9
7.5
7.7
13.8
015
022
037
055
075
110
1
2
3
5
7.5
10
15
0.75
1.5
2.2
3.7
5.5
7.5
11
1.9
3
4.5
6.1
9.1
12.2
17.5
2.5
4
6
8
12
16
24
Three-phase 380 ~ 480V
0.1 ~ 400Hz (Sensorless control: 0.1~300Hz, Sensored control: 0.1~120Hz)
Three-phase 380 ~ 480V (10%)
50 ~ 60Hz (5%)
4.7
4.7
4.8
4.9
7.7
7.7
13.9
150
185
220
300
370
450
550
20
15
22.9
60
25
18.5
28.5
74
30
22
33.5
88
40
30
46
122
50
37
55
146
60
45
68
180
75
55
84
220
14.3
19.4
20.0
42.0
42.0
61
61
150
185
220
300
370
450
550
750
20
15
22.9
30
25
18.5
29.7
39
30
22
34.3
45
40
30
45
61
50
37
56
75
60
45
68
91
75
55
82
110
100
75
100
152
14.4
20
20
45
45
63
63
68
LS Inverter Series
iS7
Model Number
SV
LS inverter brand
0008
iS7
Motor rating
0008: 0.75kW ~ 1600: 160kW
Series name
iS7
Symbol
Input rating
2
Three-phase, 200 ~ 230V
4
Three-phase, 380 ~ 480V
O
Symbol
S
N
Loader
Loader
Graphic
Loader
F
Symbol
O
E
P
General specification
Model number: SV
iS7-2
Motor rating
Output rating
Input rating
Model number: SV
Capacity
Current (CT)
Current (VT)
Voltage
Frequency
Voltage
Frequency
Current (CT)
Current (VT)
iS7-4
Motor rating
Output rating
Input rating
Control Spec
Operation
Input signal
008
[HP]
[kW]
[kVA]
[A]
[A]
[V]
[Hz]
[V]
[Hz]
[A]
[A]
Capacity
Current (CT)
Current (VT)
Voltage
Frequency
Voltage
Frequency
Current (CT)
Current (VT)
Control method
Speed reference resolution
Frequency accuracy
V/f curve
Overload capacity
Torque boost
Keypad Display
Operation method
Frequency setting
Operation function
Output signal
Multi-function terminal
(P1 ~ P8)
Multi-function relay
Multi-function open collector
Analog output
Protection
Inverter trip
Inverter alarm
Enclosure
Option
Others
*Available soon
022
037
055
075
110
150
185
UL Certification
Open type
Enclosed Type 1
(NEMA1)
NEMA 12
Symbol
None
F
Filter
Not available
EMC filter
Symbol
DCR
None Not available
D
DC Reactor
220
1
2
3
5
7.5
10
15
20
25
30
0.75 1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
1.9
3
4.5
6.1
9.1 12.2 17.5 22.9 28.5 33.5
5
8
12
16
24
32
46
60
74
88
8
12
16
24
32
46
60
74
88
124
Three-phase 200 ~ 230V
0.01 ~ 400Hz (Sensorless-1 control: 0.01~300Hz, Sensorless-2 or Sensored control: 0.01~120Hz)
Three-phase 200 ~ 230V (-15% ~ +10%)
50 ~ 60Hz (5%)
8.3 12.9 18.6
24
32.9 41.4
58
69
88
96
7
10.6 14.8 21.8
28
42
52
60
75
107
008
[HP]
[kW]
[kVA]
[A]
[A]
[V]
[Hz]
[V]
[Hz]
[A]
[A]
015
015
022
037
055
075
110
150
185
220
300
370
450
1
2
3
5
7.5
10
15
20
25
30
40
50
60
0.75 1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
1.9
3
4.5
6.1
9.1 12.2 17.5 22.9 29.7 34.3
46
57
69
2.5
4
6
8
12
16
24
30
39
45
61
75
91
4
6
8
12
16
24
30
39
45
61
75
91
110
Three-phase 380 ~ 480V
0.01 ~ 400Hz (Sensorless-1 control: 0.01~300Hz, Sensorless-2 or Sensored control: 0.01~120Hz)
Three-phase 380 ~ 480V (-15% ~ +10%)
50 ~ 60Hz (5%)
4.3
7.2 10.6 15.4
21
25.8
39
44
57
57
57
69
83
3.5
5.3
7.3
10.8 13.8 22.5
26
33
40
52.2
90
109 123
550
750
900
75
55
84
110
152
100
75
116
152
183
120
90
139
183
223
150
110
170
223
264
180
132
201
264
325
225
160
248
325
370
113
162
154
195
195
237
239
282
286
350
362
403
V/f, V/f PG, Slip compensation, Sensorless-1 vector, Sensorless-2 vector, Sensored vector
Digital command: 0.01Hz / Analog reference: 0.06Hz (Max freq., 60Hz)
Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
Linear, Squared, User custom V/f
CT(Heavy duty): 150% for 1 minute, VT(Normal duty): 110% for 1 minute
Auto & Manual torque boost
Wide graphic LCD keypad (available 6 languages*)
Keypad / Terminal / Communication
Analog: 0 to 10V / -10 to 10V/ 0 to 20mA / Digital: Keypad
PID control / Up-Down operation / 3-Wire operation / DC braking / Frequency limit / Second function / Slip compensation / Reverse rotation prevention /
Auto restart / Inverter By-pass / Auto-tuning / Flying star / Energy buffering / Power braking / Flux braking / Low leakage / MMC / Easy start
PNP / NPN selectable
8 points (programmable)
(N.O., N.C.) Less than AC250V, 1A / Less than DC 30V 1A
Fault output & inverter status output
DC24V (less than 50mA)
0 to 10Vdc (less than 10mA): frequency / current / voltage / DC voltage selectable
Over current / Over voltage / Low current / External trip / Ground fault / Inverter overheat / I/O phase open / Overload / Communication error /
Frequency command loss / Hardware fault / Fan fault / Pre-PID fault / No motor trip / External brake trip / etc.
Stall prevention / Overload / Light load / Encoder connection error / Keypad command loss /
Speed command loss
IP21(0.75~75kW[1~100HP]), IP20(90~160kW[125~215HP]), IP54(0.75~22kW[1~30HP])*, UL Type 1(Optional)*
Graphic LCD keypad(IP21), Extension I/O, Isolation I/O, Encoder board, PLC board, Remote cable(2M/3M)
Profibus-DP, DeviceNet, Modbus TCP, Rnet, LonWorks, CANopen, EtherNet/IP*
Built-in Dynamic braking transistor (0.75~22kW[1~30HP]), Built-in RS485(LS Bus / Modbus RTU)
iH
Model Number
SV
LS inverter brand
037
iH
Motor rating
030:30kW ~ 220: 220kW
Series name
iH
Symbol
Input rating
2
Three-phase, 200 ~ 230V
4
Three-phase, 380 ~ 480V
380V
Symbol UL Certification
U
UL 508C
Symbol
Rated voltage
****
220V, 380V, 440V, 460V
General specification
Model number: SV
Motor rating
Output ratings
(380V based)
Input ratings
iHConstant Torque
Constant Torque
Variable Torque
Variable Torque
Constant Torque FLA
Constant Torque
Variable Torque FLA
Variable Torque
Voltage
Frequency
Voltage
Frequency
Weight
055-2U
40
30
50
37
60
45
75
55
122
46
146
55
180
68
220
83
030-4U 037-4U
40
50
60
75
30
37
45
55
50
60
75
100
37
45
55
75
61
75
91
110
40
50
60
70
80
96
115
125
52
62
74
80
Three-phase, 380 ~ 460V
0.5 ~ 400Hz
Three-phase, 380 ~ 460V (10%)
50 ~ 60Hz (5%)
45
45
63
63
160-4U 220-4U
100
75
125
90
152
100
160
103
125
90
150
110
183
120
228
147
150
110
175
132
223
145
264
170
175
132
215
160
264
170
330
213
215
160
250
185
325
200
361
233
300
220
350
280
432
280
477
307
68
98
98
122
122
175
Control method
Speed reference resolution
Frequency accuracy
V/f curve
Overload
Constant Torque
capacity
Variable Torque
Torque boost
Multi-function input termanl
Multi-function output
Analog output
Input signal
Operation method
Frequency setting
Start signal
Multi-step operation
Multi-step Accel/Decel time
Operation function
Emergency stop
JOG
Fault reset
Output signal
Operating status
Frequency detection level / Overload alarm / Stalling / Over voltage / Low voltage / Inverter overheat/ Run / Stop /
Constant speed / Speed search
RPM, Output frequency / Output current / Output voltage(Voltage: 0~10V, Pulse : 500Hz)
Indicator
Protection
Enclosure
Option
Inverter trip
Inverter alarm
Over voltage / Low voltage / Over current / Inverter overheating / Fuse open / Ground fault / Overload / M/C fail / etc.
Stall prevention / Overload
IP00
RS485(LS Bus), Remote cable(2M/3M/4M)
LS Inverter Series
iP5A
Model Number
SV
LS inverter brand
055
Motor rating
055: 5.5kW ~ 4500: 450kW
iP5A
Series name
iP5A
Symbol
Input rating
2
Three-phase, 200 ~ 230V
4
Three-phase, 380 ~ 480V
Symbol Loader
None
Loader
N
Non Loader
Symbol UL Certification
O
Open type
E
Enclosed Type 1
Symbol
DCR
None Not available
L
DC Reactor
General specification
Model number: SV
iP5A-2
Motor rating
(Fan/Pump)
Current
(110% overload)
Motor rating
(General load)
Current
(150% overload)
Output rating
Input rating
Weight
Model number: SV
Voltage
Frequency
Voltage
Frequency
Non DCR type
Current
(110% overload)
Motor rating
(General load)
Current (Non DCR / DCR)
(150% overload)
Output rating
Weight
Control Spec
Operation
Input signal
Output signal
Voltage
Frequency
Voltage
Frequency
Non DCR type
Built-in DCR type
Control method
Speed reference resolution
Frequency accuracy
V/f curve
Overload capacity
Torque boost
Keypad Display
Operation method
Frequency setting
Operation function
Sart signal
Multi-step
Multi-step Accel/Decel time
Emergency stop
JOG
Fault reset
Operating status
Fault output
Indicator
Protection
Enclosure
Option
*Available soon
10
[HP]
[kW]
[A]
[kVA]
[V]
[Hz]
[V]
[Hz]
[kg]
iP5A-4
Motor rating
(Fan/Pump)
Input rating
055
[HP]
[kW]
[A]
Inverter trip
220
300
7.5
10
15
20
25
30
5.5
7.5
11
15
18.5
22
24
32
46
60
74
88
Normal duty: 110% for 1 minute
5
7.5
10
15
20
25
3.7
5.5
7.5
11
15
18.5
17
23
33
44
54
68
Heavy duty: 150% for 1 minute
9.1
12.2
17.5
22.9
28.2
33.5
Three-phase 200 ~ 230V
0.01 ~ 120Hz
Three-phase 200 ~ 230V (-15% ~ +10%)
50 ~ 60Hz (5%)
4.9
6
6
13
13.5
20
40
30
115
055
[HP]
[kW]
[A]
[HP]
[kW]
[A]
[kVA]
[V]
[Hz]
[V]
[Hz]
[kg]
[kg]
075
075
110
110
150
150
185
185
7.5
10
15
20
25
5.5
7.5
11
15
18.5
12
16
24
30
39
Normal duty: 110% for 1 minute
5
7.5
10
15
20
3.7
5.5
7.5
11
15
8.8
12
16
22/24 28/30
Heavy duty: 150% for 1 minute
9.6
12.7
19.1
23.9
31.1
Three-phase 380 ~ 480V
0.01 ~ 120Hz
Three-phase 380 ~ 480V (-15% ~ +10%)
50 ~ 60Hz (5%)
4.9
6
6
12.5
13
19.5
19.5
30
22
84
43.8
20
220
300
370
450
550
750
900
30
22
45
40
30
61
50
37
75
60
45
91
75
55
110
100
75
152
125
90
183
175
132
264
215
160
325
300
220
432
350
280
547
400
315
613
500
375
731
600
450
877
25
18.5
34/39
30
22
44/45
40
30
61
50
37
75
60
45
91
75
55
110
100
75
152
125
90
183
150
110
223
175
132
264
215
160
325
300
220
432
350
280
547
400
315
613
500
375
731
35.9
48.6
59.8
72.5
87.6
121.1
145.8
178
210
259
344
436
488
582
699
20
26.5
20
26.5
27
39
27
40
29
42
42
67
43
68
243
280
380
101
101
114
200
200
Inverter alarm
Over voltage / Low voltage / Over current 1, 2 / Ground fault / Inverter overheating / Electronic thermal / Output phase open / overload /
External Fault A, B / Communication Error / Frequency command loss / Hardware fault / Option fault / etc
Stall prevention / Overload / Temperature sensor fault
iV5
Model Number
SV
LS inverter brand
022
iV5
Motor rating
022: 2.2kW ~ 3750: 370kW
Series name
iV5
DB
Symbol
Input rating
2
Three-phase, 200 ~ 230V
4
Three-phase, 380 ~ 480V
(MD)
Symbol
None
(MD)
380V
Cover type
Metallic cover
Mold cover*
Symbol
Rated voltage
None 200~230V or 380~480V
****
380V, 460V, 480V*
General specification
Model number: SV
iV5-2
Motor rating
Output rating
Input rating
Weight
Model number: SV
Capacity
Current
Voltage
RPM
Voltage
Frequency
Mold cover type
Metallic cover type
Input rating
Weight
Control Spec
Capacity
Current
Voltage
RPM
Voltage
Frequency
Mold cover type
Metallic cover type
Input signal
Control method
Speed reference resolution
Speed accurancy
Cut-off frequency of ASR
Torque control accuracy
Accel/Decel time
Accel/Decel combination
Aceel/Decel curve
Frequency setting
Analog input
Output signal
Aanalog output
Contact input
Contact output
Open collector
Protection
Enclosure
Option
[V]
[Hz]
[kg]
[kg]
iV5-4
Motor rating
Output rating
022
[HP]
[kW]
[kVA]
[A]
[V]
[HP]
[kW]
[kVA]
[A]
[V]
[V]
[Hz]
[kg]
[kg]
037
055
075
110
3
5
7.5
10
15
2.2
3.7
5.5
7.5
11
4.5
6.1
9.1
12.2
17.5
12
16
24
32
46
Three-phase 200 ~ 230V
0 ~ 3600 [RPM]
Three-phase 200 ~ 230V (+10%, -10%)
50 ~ 60Hz (5%)
6
6
7.7
7.7
13.7
14
14
28
022
037 055
075
110
3
5
7.5
10
15
2.2
3.7
5.5
7.5
11
4.5
6.1
9.1
12.2
18.3
6
8
12
16
24
Three-phase 380 ~ 480V
0 ~ 3600 [RPM]
Three-phase 380 ~ 480V (+10%, -10%)
50 ~ 60Hz (5%)
6
6
7.7
7.7
13.7
14
14
28
150
185
220
300
370
20
15
22.5
59
25
18.5
28.2
74
30
22
33.1
88
40
30
46
122
50
37
55
146
13.7
28
20.3
28
20.3
28
42
42
150
185
220
300
370
750
20
15
22.9
30
25
18.5
29.7
39
30
22
34.3
45
40
30
46
61
50
37
57
75
60
45
70
91
75
55
85
110
100
75
116
152
120
90
140
183
150
110
170
223
175
132
200
264
215
160
250
325
300
220
329
432
373
280
416
546
420
315
468
614
500
375
557
731
13.7
28
20.3
28
20.3
28
42
42
63
63
68
98
98
112
112
175
243
380
380
450 550
Board
Communication
IP00 (2.2~22kW[3~30HP]: Mold cover* / 30~374kW[40~500HP]: Metallic cover), IP20 (2.2~22kW[3~30HP]: Metallic cover)
EL I/O(for Elevator application), Encorder division(open collector), Synchronization option(Speed/Position control), Sincos encorder
RS485(LS Bus / Modbus RTU), Profibus-DP, DeviceNet
*Available soon
LS Inverter Series
11
Comparison
Variable Frequency Drive / Inverter
iE5
Model Series
Input Phase
Voltage Range
Motor rating
Constant Torque
Variable Torque
Control method
Enclosure
Single-phase
iC5
Three-phase
200~230V
0.1~0.4kW
0.1~0.4kW
0.13~0.5HP
0.13~0.5HP
Standard
V/f
Sensorless Vector
Sensored Vector
IP00
Standard
Single-phase
iG5A
Single-phase
200~230V
iS5
Three-phase
380~480V
200~230V
380~480V
0.4~2.2V
0.4~1.5kW
0.4~22kW
0.4~22kW
0.75~55kW
0.75~75kW
0.5~3HP
0.5~2HP
0.5~30HP
0.5~30HP
1~75HP
1~100HP
Standard
200~230V
Three-phase
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Option
Standard
Standard
11~22kW
11~75kW
15~30HP
IP20
15~100HP
Standard
Standard
Standard
Standard
0.1~0.4kW
0.4~2.2kW
0.4~22kW
0.75~7.5kW
0.13~0.5HP
0.5~3HP
0.5~30HP
1~10HP
IP21
IP54
UL Type 1
Option
0.4~22kW
0.5~30HP
Keypad
Type
Built-in
Fixed type
Fixed type
Fixed type
0.1~0.4kW
0.4~2.2kW
0.4~22kW
30~55kW
30~75kW
0.13~0.5HP
0.5~3HP
0.5~30HP
40~75HP
40~100HP
Option
Detachable type
0.75~22kW
1~30HP
Remote cable
2 meters
3 meters
5 meters
Braking transistor
EMC Filter
Option
Option
Option
Option
Option
Option
Standard
Standard
0.4~22kW
0.75~7.5kW
0.5~30HP
1~10HP
Built-in Option
0.4~2.2kW
0.5~3HP
DC Reactor
RS485(LS Bus)
Modbus RTU
Modbus TCP
DeviceNet
Profibus-DP
Fnet(LS PLC link)
Rnet
LonWorks
CANopen
BACnet
EtherNet/IP
CC-Link
MMC(Mulit Motor Control)
Encoder
Sincos encoder
PLC
Extension I/O
Elevator I/O
Synchronization I/O
12
Standard
Standard
Option
Standard
Option
Standard
Option
Option
Option
Option
Option
Option
Option
Model Series
iS7
iH
iP5A
iV5
Input Phase
Voltage Range
Motor rating
Three-phase
Three-phase
Three-phase
Three-phase
Constant Torque
Variable Torque
Control method
Enclosure
200~230V
380~480V
200~230V
380~480V
200~230V
380~480V
200~230V
380~480V
0.75~22kW
0.75~160kW
30~55kW
30~220kW
5.5~30kW
5.5~450kW
2.2~37kW
2.2~375kW
1~30HP
1~215HP
40~75HP
40~300HP
7.5~40HP
7.5~600HP
3~50HP
3~500HP
V/f
Sensorless Vector
Sensored Vector
IP00
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Option
Standard
Standard
Standard
Standard
Standard
15~30kW
15~450kW
2.2~22kW
2.2~375kW
20~600HP
3~30HP
3~500HP
20~40HP
IP20
IP21
IP54
Standard
Standard
Standard
Standard
Standard
90~160kW
30~55kW
30~220kW
5.5~11kW
5.5~22kW
125~215HP
40~75HP
40~300HP
7.5~15HP
7.5~30HP
Standard
Standard
0.75~22kW
0.75~75kW
1~30HP
1~100HP
Built-in Option
0.75~22kW
1~30HP
UL Type 1
Option
Standard
Standard
0.75~75kW
5.5~11kW
5.5~11kW
7.5~15HP
7.5~15HP
1~100HP
Keypad
Type
Built-in
Option
Detachable type
Detachable type
Detachable type
Detachable type
90~160kW
30~220kW
37~450kW
2.2~370kW
125~215HP
40~300HP
50~600HP
3~500HP
0.75~75kW
5.5~30kW
1~100HP
Remote cable
2 meters
3 meters
5 meters
Braking transistor
EMC Filter
7.5~40HP
Option
Option
Option
Option
Option
Option
Option
Option
Standard
Standard
0.75~22kW
2.2~22kW
1~30HP
3~30HP
Built-in Option
0.75~22kW
1~30HP
DC Reactor
RS485(LS Bus)
Modbus RTU
Modbus TCP
DeviceNet
Profibus-DP
Fnet(LS PLC link)
Rnet
LonWorks
CANopen
BACnet
EtherNet/IP
CC-Link
MMC(Mulit Motor Control)
Encoder
Sincos encoder
PLC
Extension I/O
Elevator I/O
Synchronization I/O
Built-in Option
Built-in Option
Built-in Option
0.75~22kW
0.75~160kW
15~280kW
1~30HP
1~215HP
Standard
20~350HP
Option
Standard / Option
Option
Standard
Option
Option
Option
Option*
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option*
Option*
Standard
Option
Standard
Standard
Option
Option
Option
Option
Option
* Available soon
LS Inverter Series
13
Option list
Variable Frequency Drive / Inverter
Series
iC5
iG5A
iS5
Option
iC5 Modbus communication card
Current output board (Only available in case that the dedicated O/S is installed)
SV-iS5 MMC
SV-iS5/iH RS485
SV-iS5 MODBUS
SV-iS5/iP5A/iV5 DEVICENET
SV-iS5 F-NET
SV-iS5/iP5A/iV5 PROFIBUS
iS7
iH
iP5A
iV5
* Available soon
14
Description
Graphic LCD display keypad for iS7 (128x64 COG, 11 Rubber Key, 3 LED, IP21)- Multi Languages
(English, Italian, Spanish, Russian, Turkish, Arabic) *
SV-iS7 ENCODER
SV-iS7 PROFIBUS-DP
SV-iS7 PLC
SV-iS7 R-net
SV-iS7 DEVICENET
SV-iS7 LONWORKS
SV-iS7 CANopen
SV-iS5/iH RS485
SV-iP5A BACNet
SV-iP5A/iV5 RS485/Modbus-RTU
SV-iS5/iP5A/iV5 DEVICENET
SV-iS5/iP5A/iV5 PROFIBUS
SV-iV5 EL I/O
SV-iV5 ENC_DIV(OC)
SV-iS5/iP5A/iV5 PROFIBUS
SV-iS5/iP5A/iV5 DEVICENET
SV-iP5A/iV5 RS485/Modbus-RTU
Model name
Specifications
SV150DBU-2
SV220DBU-2
SV037DBH-2(NEW)
SV150DBU-4
SV220DBU-4
SV037DBH-4(NEW)
SV075DBH-4(NEW)
SV150DBU-2U
SV220DBU-2U
SV370DBU-2U
SV550DBU-2U
SV150DBU-4U
SV220DBU-4U
SV370DBU-4U
SV550DBU-4U
SV750DBU-4U
SV750DB-4*
SV2200DB-4*
* Available soon
Model name
Specifications
LS Inverter Series
15
For your safety, please read user's manual thoroughly before operating.
Contact the nearest authorized service facility for examination, repair, or adjustment.
Please contact qualified service technician when you need maintenance.
Do not disassemble or repair by yourself!
Safety Instructions
Any maintenance and inspection shall be performed by the personnel having expertise concerned.
www.lsis.biz
HEAD OFFICE
Global Network
Europe
+82-2-2034-4376 / ywsohn@lsis.biz
Middle East
+82-2-2034-4901 / bonseongk@lsis.biz
+82-2-2034-4645 / sungkyup@lsis.biz
+82-2-2034-4707 / ohpark@lsis.biz
CIS
+82-2-2034-4913 / jinhkang@lsis.biz
America
+82-2-2034-4377 / younsupl@lsis.biz
Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China
Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn
2010. 03