Beruflich Dokumente
Kultur Dokumente
com
Refrigeration Dryers
SECOTEC
Air flow rate 0.6 to 14.3 m/min
www.kaeser.com
SECOTEC
Premium components
High quality, generously-sized components, such as
in the condenser for example, ensure optimum flow
at all times, even at high operating temperatures, and
guarantee a long and dependable service life as
exemplified by the stainless steel condensate separator. Details such as the use of smooth-bore copper
piping in the refrigeration circuit also contribute to
exceptional system efficiency.
Rating for
SECOTEC
B
C
D
E
F
G
H
Extremely high energy consumption
Impressive performance
and eciency
Image: SECOTEC TB 19
www.kaeser.com
SECOTEC
Quality counts
Rating for
SECOTEC
B
C
D
E
F
G
H
Extremely high energy consumption
Exceptional eciency
No pre-filter
www.kaeser.com
SECOTEC
Quality engineered
Image:
TE 61 internal view
www.kaeser.com
SECOTEC
Easy to maintain
Maintenance-friendly design
Excellent accessibility
KAESER service technicians and our partners technical staff are refrigeration technology experts. They
not only check operation of the refrigeration dryer,
but also of the cooling circuit itself using intake- and
pressure-side service valves.
www.kaeser.com
43C
90 %
80 %
Additional energy-saving
potential (for use at summer
temperatures, e.g. ambient
temperature 40 C)
40C
35C
30C
25C
70 %
60 %
50 %
Early shift
40 %
Day shift
30 %
20 %
10 %
Midday break
Air consumption
0%
Time
6 - 14
14 - 22
Night shift
22 - 6
10
11
www.kaeser.com
Equipment
Installation example 1
General design
Refrigeration circuit
Operating panel
Equipped with dew point trend indicator, emergency stop switch, LEDs to
indicate Thermal mass active and
Refrigerant compressor ON.
Installation example 2
LEDs for High dew point and ECODRAIN alarm are fitted as standard on
TE models and upwards. TF models
and upwards feature two operating
hours counters.
General design
Example: TE Series
Compressed
air outlet
Compressed air
inlet
Installation example 3
Ref
rige
rant
Refrigerant compressor
Ref
rige
rant
Condenser
Capillary tubes
Filter / dryer
High pressure switch
Low pressure switch
Fan pressure switch
PDP trend indicator
12
13
www.kaeser.com
Dimensions
Technical specifications
Modell*)*)
Model
Volumenstrom
Flow rate
bei
bar
at 77bar
Betriebsoperating
berdruck
pressure **)
**)
Pressure
Druckverlust
loss
m/min
TA 5
E
eektive
ective
Leistungsaufnahme
power consumption **)
bei
At 100
100%
%
Volumenflow
strom
volume
bei
At 50
50%
%
Volumenflow
strom
volume
bei
At 10
10%
%
Volumenflow
strom
volume
bar **)
kW
kW
kW
0.60
0.07
0.29
0.16
0.04
TA 8
0.85
0.14
0.27
0.15
0.04
TA 11
1.25
0.17
0.28
0.15
0.04
TB 19
2.10
0.19
0.55
0.30
0.08
TB 26
2.55
0.20
0.62
0.34
0.09
TC 31
3.20
0.15
0.75
0.41
0.11
TC 36
3.90
0.16
0.88
0.48
0.13
TC 44
4.70
0.15
0.89
0.49
0.13
TD 51
5.65
0.11
0.86
0.47
0.13
TD 61
7.00
0.15
1.10
0.61
0.17
TD 76
8.25
0.17
1.40
0.77
0.21
TE 91
10.15
0.15
1.15
0.63
0.17
TE 121
12.70
0.18
1.45
0.80
0.22
TE 141
14.30
0.24
1.60
0.88
0.24
Electrical
Elektrische
supply
Versorgung
AirAnschluss
connection
Druckluft
(Female
(Innenthread)
gewinde)
Connection
Anschluss
Kondensatcondensate
ablass
outlet
Abmessungen
Dimensions
B x TD xx HH
W
Gewicht
Weight
Front view
Rear view
Left view
Right view
3-D view
TA series
mm
kg
70
230 V
50 Hz
1 Ph
779
80
85
108
230 V
50 Hz
1 Ph
G1
DN 10
484
630
TB series
116
155
230 V
50 Hz
1 Ph
G 1
DN 10
963
170
200
540
620
251
G 1
400 V
50 Hz
3 Ph
TC series
DN 10
G2
251
287
570
400 V
50 Hz
3 Ph
G2
2 x DN 10
1009
660
660
774
660
TD series
*) Refrigerant used R 134 a; max. operating pressure 16 bar(g); max. compressed air inlet/ambient temperature 55/43 C
**) Performance data for reference conditions to ISO 7183, Option A1: Operating pressure 7 bar (g), ambient temperature + 25 C,
compressed air inlet temperature + 35 C, pressure dew point + 3 C. The flow rate and dierential pressure change for other operating conditions.
Correction factors for deviating operating conditions (flow rates in m/min x k...)
1187
Modell
Model
ppbar
bar()
(g)
10
11
12
13
14
15
16
TA-TF
kp
0.75
0.84
0.90
0.95
1.00
1.04
1.07
1.10
1.12
1.15
1.17
1.19
1.21
1.23
Modell
Model
TTei (C)
(C)
30
35
40
45
50
55
Modell
Model
Tua (C)
25
30
35
40
43
TA-TF
kTe
Ti
1.20
1.00
0.83
0.72
0.60
0.49
TA-TF
kTu
Ta
1.00
0.99
0.97
0.94
0.92
TE series
Example:
14
1125
Ambient temperature Ta
Working pressure:
759
1513
kp = 1.10
Table
kTi = 0.83
Ambient temperature:
Table
kTa = 0.99
10 bar (g)
30 C
1060
1520
15
www.kaeser.com
Explanation
Pharmaceuticals industry,
weaving machines, photo
labs
Oil
Installation for
fluctuating air demand
DHS
KE
1
DHS
KD
KE
ZK
AQUAMAT
AQUAMAT
DD
Desiccant dryer
DHS
AR
Air receiver
ED
ECO-DRAIN
KA
KB
KBE
Extra Combination
KD
KE
KEA
Carbon Combination
RD
Refrigeration dryer
THNF
Bag filter
ZK
Centrifugal separator
DHS
RD
AR
KEA
RD
Optional
filtration
AR
DHS
ACT
ACT
ED
Compressor
THNF
Solid particles/dust
Class
KE
0.1 d 0.5
0
AQUAMAT
DHS
DHS
KB
7-X
1
2
3
4
5
0.5 d 1.0
1.0 d 5.0
400
6,000
90,000
Not defined
Not defined
10
100
1,000
10,000
100,000
Class
6
7
X
0 < Cp 5
5 < Cp 10
Cp > 10
Water
Process air,
pharmaceuticals
Especially dry conveying
air, paint spraying, fine
pressure controllers
1)
2)
3)
4)
1-3
1-3
Oil2
DHS
KE
DHS
KE
1
KD
Optional
AR filtration
ACT
1-3
1-3
KBE4
DHS
1-3
1
2
3
4
5
6
70 C
40 C
20 C
+ 3 C
+ 7 C
+ 10 C
Class
7
8
9
X
CW 0.5
0.5 < CW 5
5 < CW 10
CW > 10
KEA
AT3
DHS
KE ZK
AR
DHS
DD3
KE
Compressor
THNF
KD
AQUAMAT
Oil
Class
1
2
3
4
X
0.01
0.1
1.0
5.0
> 5.0
KAESER KOMPRESSOREN SE
P.O. Box 2143 96410 Coburg GERMANY Tel +49 9561 640-0 Fax +49 9561 640130
e-mail: productinfo@kaeser.com www.kaeser.com
Solids1 Water
Installation for
fluctuating air demand
Class