Sie sind auf Seite 1von 27

Gas Analysis Technology

- optimization & upgrade

Agenda:
Gas Analysis for Optimization & Upgrade
Introduction to gas analysis
Kiln inlet analyzer for optimization
Upgrade of existing kiln inlet analyzer system

Optimization benefits

Upgrades of gasanalysis
At filter
In coal mill department
For emission monitoring
Maintenance and support

By Christian Markussen
Area Sales Manager / Product Specialist

Gas Analysis where and why?


Where ?
Kiln inlet
Calciner exit
Preheater exit
Coal mill department
Stacks
WHY ?
Process optimization
Safety control
Emission control

Specialised in sample handling

GASloq system layout


Gas conditioning
Analyzers
System controller
Cabinet or site shelter

Optimization and upgrades


- requires gas analysis

4. Coal mill dept.

Optimization with ECS/ProcessExpert


Fundamental data
Temperature
Pressure
Feed rate
Fuel rate
Raw material analysis
Clinker material analysis
Combustible analysis
Gas analysis

Gas analysis for kiln optimization


Kiln Inlet or Calciner Exit

Simple - Strong - Reliable


Main focus is easy maintenance

Kiln inlet reality


The most difficult place to measure
The equipment has been known as
Complicated tubing, valves etc.
Weak probes are bending
Time consuming probe are blocking

The measurement is known as


Top 3 of Most Wanted signals

Kiln inlet is the


best spot for:
Optimized fuel consumption

Optimize quality
Stable and safe kiln operation
Kiln stop prevention
Emission reduction

O2 /CO Targets:
Optimized fuel consumption
Optimize quality
Stable and safe kiln operation
Kiln stop prevention
Emission reduction
Safety
The operators are depending on the kiln inlet analyser system in order to
fully reach the kiln design capacity at optimum operating conditions

Oxygen analysis is on TOP 3 of any operators Most


Wanted signal list

NO Targets:
Clinker quality improvement

Burning zone temperature trend


Lower emission

SO2 Targets:
Volatile control

Prevent kiln stops


Reduction of material build-ups
Reduction of ring formation in kiln
Reduction of manual kiln clean-out
Reduction of kiln system corrosion

CO analysis combined with O2 is very powerful in


evaluating kiln performance

Selection of correct sample point


The sampling point has to be taken in respect to:

Representative gas
No influence from any false air
Mechanical impact from material fall through
Risk of material build-up
Dust impact
Condensation from volatiles
Practical installation with regard to available
platform location and minimized obstacles
outside

KilnLoq solution

Air cannon gas analysis


Simple: An Air cannon is one large air receiver, one
valve and one pipe
Strong: An Air cannon is very strong and powerful in
construction and operation
Reliable: An Air cannon is installed, connected and
then forgotten
Air cannon
Air blaster One pipe design

Air receiver

Valve

Pipe/Nozzle

Patented - One Pipe design


The normal filter construction compared
to the coaxial One Pipe filter design:

The Shock Blaster Effect

Process
dust

Filter
surface
cleaning

ONE PIPE
cleaning.
Works as
efficient as a
shock blaster

Amplification
chamber

Effectiv probe tip cleaning

Easy Maintenance
Full admission all the way
to probe end by removing
access port

Inspection of probe
and maintenance can
be made without
dismantling

Access only possible due to


the ONE PIPE probe design

KilnLoq probe and extraction device

10

Avoid bending of the KilnLoq Probe

Built to last

KilnLoq has many features that prevent the probe from


bending

Heavy multi layer steel construction more than 8 times


stronger
Automatic periodical extraction of probe to minimize material
build-ups
Automatic shock blaster control integrated
Remote or local extraction of probe during kiln clean out
Measurement of heat input to probe from process
Probe position feature minimises insertion length
Using water as cooling

Easy Maintenance

11

Upgrade of existing kiln inlet analyzer system


We can assist you
Determine the best
measuring point
Evaluating reuse of
existing equipment
Integrate existing
analyzer units and even
fix these
Find the most
competitive deal

Performance Status on KilnLoq

In operation since spring 2003

More than 200 KilnLoq systems commissioned

More than 240 systems sold

Highest run factor on the marked


in most cases higher than 95%

An average of 60 min weekly preventive maintenance

8 KilnLoq systems in Pakistan

12

Optimization benefits
An reduction of 1% O2 in the kiln = 2% higher clinker
production
An reduction of 1% O2 in the kiln = 1% lower fuel
consumption
A shortage in oxygen level of 1% in the kiln inlet will cause
kiln stops, wear, excessive manual clean-outs

Oxygen analysis is on TOP 3 of any operators Most


Wanted signal list

Conclusion Kiln inlet

Reduce fuel cost or get higher production

Reduce production stops

Proven technology more than 200 references

Correct and continuous analyser signals

Highest run factor on the marked

Easiest maintenance on the marked

Getting a simple, strong and reliable gas analyser


system

Very short payback time typical less than 200 days

13

Upgrades of filter or use of alternative


fuels may require new gasanalysis

Filter protection system


Safety & Interlocking

14

Filter protection system


CO/CH4 and O2:
GASloq 1200
Low installation costs
Low
True
installation
continuous
through
simple costs
samplingFLS
by Airloq
double
standard
plug
and play modular
probe gives
maximum
modular
design
design
safety
High operation
powered probe
Easy
through
High run
factor
due to
cleaning
air gives
large HMIby
colour
touch
simple
layout
better
run
factor
for
the
screen
equipment
High resistance to
No moving parts
contamination
andin
probe ensures
trouble
corrosion
from the
free service
process
gas and DDOP probe
maintenance
Focus on design for easy
Build-in air receiver
maintenance
ensures the highest
possible pressure at any
time

Probe Cleaning Panel

Double Dry nOn cooled Probe (DDOP)

Made of stainless steel


Maximum temperature 600C
Maximum dust: 200 g/m3
Weather protection

15

Equipment for Measuring at Coal Mill Area

16

Coal Mill Area


Supervision of coal mill department in silos and dust
collectors
Detects impending spontaneous combustion of coal
Operation data for inert coal mill process
Single or Multi Scanning capabilities

Coal Mill Area Analyser Systems

GASloq 1200 multiscan system


Up to 6 silo measuring points
Continuous O2 at filter
ABB, Siemens or Emerson
analysers
Power

GASloq 600 single probe system


Used for silo or filter
ABB, Siemens or Emerson
analysers

17

Upgrade of gas analysis to fulfil


emission requirements

Different solutions for measuring gas


depending on requirements
GASloq system

NEO LaserGas Monitor

CO, CO2, NOx, SO2, TOC, O2

CO, CO2, NO, NO2, SO2,


H2O, HCl, HF, NH3

18

Different solutions for measuring dust


depending on requirements
Durag D-R 800

Durag D-R 300

Durag D-R 290

Durag D-R 800 Optical Dust Monitor

Forward scattered light reflection


principle
Designed for small and medium dust
concentrations
Easy one-side installation
Easy configuration without need for PC
Integrated purge air unit in the
electronics unit
Automatic function test with soiling
correction
TV 17. BImSchV approved
M-Certs approval pending
Purging Air

Pane
Fibre Optic

Receiver
Diode

Reference Light Beam


Transmitter
Diode

Measuring Light Beam


Shutter
Measuring
Volume
Light Trap

Beam
Splitter

Objective
Cleaning
Flange

19

Emission Monitoring and Reporting


SO2
CO TOC
HCL
HF
NOx

Dust

Measurement

Environmental reporting systems type ReportLoq


Meets local legislation for environmental reporting
Integrated solution with emission monitoring equipment

PLC

Control
System

Real-time
Monitoring

History, Analysis
& Reporting

Analyser

Controller

ECS or none-ECS

ReportLoq

We cheated a little
you dont really need the wrench

20

Easy maintenance

Human Machine Interface (HMI) display

21

Human Machine Interface (HMI) display


Used for setup of the system
Used for information on status, failure and warnings

Human Machine Interface (HMI) display


System start/stop and manuel probe cleaning

22

Human Machine Interface (HMI) display


Calibration

Human Machine Interface (HMI) display


Alarm list

23

Human Machine Interface (HMI) display


Trend facilities

Spare parts

gas-service@flsmidth.com

24

Service Contract
Remote service & trouble shooting by
internet
No open ports in Firewall!!

References in Pakistan

25

FLSmidth Gas Analysis Technology


a Unique Supplier
More than 40 Years of experience in combining process
knowledge from the cement and minerals industry with
practical solutions of gas analysis
Patented technology offering unique selling proposition
to our customers
Focus on simplicity high run factor through ease of
maintenance
Specialized gas analysis organization with a huge
accumulated experience base
Trouble shooting by experts supported by fast spare
part deliveries
The credibility from belong to the FLSmidth One Source
Brand

Full Gas Analysis Product Range


EQUIPMENT FOR ALL CEMENT APPLICATIONS:

Kiln Inlet competitive kiln operation

Calciner maximised throughput

Preheater filter protection system

Coal Mill secure supply of combustibles

Stack emission monitoring and reporting

26

Thank you for your attention


Friendships are like standing in wet cement The longer you stay, the harder it is to
leave, and you can never go.without
leaving your footprints behind !

Any questions

27