Beruflich Dokumente
Kultur Dokumente
DOCUMENT TITLE
METHOD STATEMENT OF
METAL WALL
INSTALLATION WORK
DOCUMENT No
V-3140-001-A-841
REV
01E
Page 1 of 4
General
1.1 Purpose
The purpose of thisStatement is todescribethe methodsemployed in the installation of
Metal wall, in particularsafe workpractices for working atheighti.e.100%fallprotection
policy.
1.2 Scope
ThisStatementisapplicableforinstallationofmetalwallinstallationwork.PT.EnconaInti
Industri will provide equipment, manpower, supervision, and inspection of metal wall
installationwork.
1.3 WorkProvidebyJGC
MetalwallmaterialandmainaccessroadtoinstallationareawillbesecuredbyJGC
Reference
2.1 ApplicableSpecifications
S0001340001BuildingGeneralSpecification
S0001520005QCRequirementforSubcontractor
S0001654010HSEPlan
S0001654020HSSEAspectIdentification,AssessmentandControlProcedure
S0001654030JobSafetyAnalysis(JSA)
S0001654050PersonalProtectionEquipment(PPE)Procedure
S0001654060HSSESignandColorCodingProcedure
S0001654070HSSECommunicationProcedure
S0001654080EmergencyResponseProcedure
S0001654280WorkingatHeightProcedure
2.2 Applicablecodesandregulation
MBMA(MetalBuildingManufactureAssociation)
AISCrelatedworksorequivalent
IndonesianNationalStandard(SNI)andotherapplicablelaws,regulationandcodes
2.3 ApplicablePT.EnconaIntiIndustriDocuments
V3140001A512QualityPlan
V3140001A503ITPforSteelStructureerectionWork
Material
3.1 Materialsourceandsupplier
MaterialsourceandsupplierwillbeJGCScope.
DOCUMENT TITLE
DOCUMENT No
METHOD STATEMENT OF
METAL WALL
INSTALLATION WORK
V-3140-001-A-841
REV
01E
Page 2 of 4
3.2 Transportationandstorage
Transportation up to Project Site will be JGC scope. EII will check and verify material
received from JGC. The quality, sizes and material condition will be checked. JGC will be
notifiedincaseofthereisdiscrepancythatcouldaffecttheerectionprocedure
WorkProcedure
4.1 Preparation
Beforeinstallingmetalwall,makesurethatallgirtsandsagrodswerecompleted
Asetonscaffoldingwillbeusedformetalwallinstallation,apulleywillbeinstalledon
scaffolding,andthisallowspullingwallsheetsafelybypeopleonthegroundoronthe
scaffolding
Wallpanelwillbemovedtotheirpositionalongthewalltoinstall
4.2 MetalWallinstallation
4.2.1 LiftingMetalWall
Drillaholewithapprox.dia3mmatthemiddleofthewallpanel,150mmfar
fromthetopforhookingwireropetothewallpanel
Liftingupandadjustpaneltorightpositionbeforeattachedtothegirt
WorkersworkingonscaffoldingmustwearPPEand100%tieofffallprotection
Metal Sheet
4.2.2 MetalWallInstallation
AscaffoldingasattachedwillbeusedforMetalWallInstallation
DOCUMENT TITLE
DOCUMENT No
METHOD STATEMENT OF
METAL WALL
INSTALLATION WORK
V-3140-001-A-841
REV
01E
Page 3 of 4
Needtobeinstallathreadtomakesurethescrewswereinstalledstraight
HealthSafetyandEnvironmentalControl
Health,SafetyandEnvironmentalControlcanbeseeninPermittoWork
ITP
RefertoITPforSteelStructureErectionwork