Design criteria
Advantages
Properties
Test method
Flow properties
(UK Dept of Transport
BD 27/86 Clause 4.6 [b]):
Setting time (BS 4550)
Initial:
Final:
Compressive strength
(BS 1881 Pt 116-restrined):
Page 1
Typical result
500 mm within
10 seconds
o
7 hrs 30 minutes at 25 C
o
10 hours at 25 C
2
45 N/mm - 24 hours
2
60 N/mm at 3 days
70 N/mm2 at 7 days
2
>80 N/mm at 28 days
0.0120 ml/m2/sec.
0.0012 ml/m2/sec.
-6 0
10 to 12 x10 / C
32 kN/mm2 at 28 days
60 N/mm2 at 28 days
The calculated equivalent
sodium oxide content of
Renderoc LA80 is
approximately
3
2.5 kg/m
Approximately 2480
kg/m3 dependent on
actual consistency used.
3 days @ 6.5 N/mm2
7 days @ 9.0 N/mm2
2
28 days @ 12.5 N/mm
Renderoc LA80
Specification clauses
Substrate priming
Several hours prior to placing, the prepared concrete
substrates should be saturated by filling the prepared
formwork with clean water. Immediately prior to the
application of Renderoc LA80, any excess water should
be removed.
In
exceptional
circumstances,
e.g.
where
a
substrate/repair barrier is required, Nitobond EP bonding
aid should be used. Contact the local Fosroc office for
further information.
Mixing
Application instructions
Preparation
The unrestrained surface area of the repair must be kept
to a minimum. The formwork should be rigid and tight to
prevent loss of material and have properly sealed faces to
ensure that no water is absorbed from the repair material.
The formwork should include drainage outlets for
presoaking and, if beneath a soffit, provision for air
venting. Provision must also be made for suitable access
points to pour or pump the mixed micro-concrete into
place.
constructive solutions
Page 2
Renderoc LA80
Low temperature working
o
In cool conditions down to 5 C, the use of warm water (up
o
to 30 C) is advisable to accelerate strength development.
Normal precautions for winter working with cementitious
materials should then be adopted. The material should
not be applied when the substrate and/or air temperature
is 5oC and falling. At 5oC static temperature or at 5oC and
rising, the application may proceed.
Limitations
Renderoc LA80 should not be used when the temperature
o
is below 5 C and falling. Do not mix part bags. The
product should not be used to reinstate horizontal areas
where the surface would remain unrestrained during cure.
It should not be exposed to moving water during
application. If any doubts arise concerning temperature,
application or substrate conditions, consult the local
Fosroc Office.
Curing
Estimating
Supply
Renderoc LA80:
Nitoprime Zincrich:
Nitobond EP:
Concure WB:
Concure 90 Clear:
Fosroc Solvent 102:
Fosroc Solvent 103:
Coverage
Renderoc LA80:
Nitoprime Zincrich:
Nitobond EP:
Concure WB:
Concure 90 Clear:
Cleaning
Renderoc LA80 and Concure WB should be removed from
tools, equipment and mixers with clean water immediately
after use.
Cured material can only be removed
mechanically.
constructive solutions
25 kg bags
1 litre and 5 litre cans
1 kg and 5 kg packs
25 kg and 200 litre drums
25 and 200 litre drums
4 litre cans
25 litre drums
Page 3
Renderoc LA80
Storage
Fire
Shelf life
Storage conditions
Store in dry conditions in the original, unopened bags or
packs. If stored at high temperatures and/or high humidity
conditions the shelf life may be reduced to 4 to 6 months.
Concure WB should be protected from frost.
Flash points
Nitoprime Zincrich:
Concure 90 Clear:
Fosroc Solvent 102:
Foroc Solvent 103:
Precautions
Health and safety
16oC
o
40 C
o
33 C
o
40 C
Additional information
Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.
www.fosroc.com
email: fosam@fosroc.com
Regional Offices
Jeddah Sales Office
Jeddah Showroom
Riyadh
Dammam
Khamis Mushayt
Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 4
FO SA/Renderoc LA80/05/A