June, 2011
Tank table
Calibration by 3rd party during shipbuilding
No
N re-calibration
lib i off tank
k unless
l
there
h
iis modification
difi i off tank
k
Just re-confirm of tank table every 10 years
S
Sworn
S
Surveyor
Calibration
Table
Ship-owner or
his agent
CTMS
FAT
Report
Application
letter
Sworn Surveyor
Must be included..
Sworn Surveyor
Supporting
Document
CTMS
Verification
Report
Sworn Surveyor
Name of vessel
2.
3.
4
4.
T t l & partial
Total
ti l capacity
it off cargo ttanks
k
5.
6.
7.
8.
9.
10. Accuracy test report for CTMS along with certificates of calibrator
11 Actual measured data
11.
12. Cargo tank gauging tables
13. Date / place of tank calibration and CTMS verification
14. Drawing of ship ( General Arrangement )
5
Application
Tank
Calibration
CTMS
Verification
Review
By Customs
Approval
Application
CTMS
Verification
R
Review
i
By Customs
Approval
Procedure
Application
Tank
Calibration
CTMS
Verification
Review
By Customs
Approval
Application
1. Surveyor will present the basic information about tank table and CTS system
to ships owner or owners agent.
2. Submission of application letter with drawing to Japanese Customs Bureau
can be done only by Ship
S
owner or owners
agent.
3. Documents for explaining CTS system and tank table are to be submitted by
th third
the
thi d party
t iindependent
d
d t surveyor.
4. If required from customs, the surveyor will explain to Japan customs directly.
Procedure
Application
Calibration
CTMS
Verification
Review
By Customs
Approval
Tank Calibration
1.
2.
Procedure
Application
CTMS
Verification
Calibration
Review
By Customs
Approval
CTMS Verification
1.
2.
Reporting CTMS
C S Verification
f
test results.
3.
Procedure
Application
Calibration
CTMS
Verification
Review
By Customs
Approval
Review by Customs
10
Procedure
Application
Calibration
CTMS
Verification
Review
By Customs
Approval
Approval
1.
2
2.
D
Delivery
li
off approved
d ttables
bl tto Shi
Ship owner via
i Shi
Ship yard
d or Agent.
A
t
11
Renewal of approval
pp
Effective from
August 1, 2010
Changed ;
T o(2) Year validation
Two(2)
alidation
Japanese Customs
Calibration Body
SGS
SNKK
NKKK
Intertek
Frequent Questions -1
Is Approval of Japanese customs bureau for the
table and CTMS verification report required in
every case of the gaseous vessel?
Independent surveyor (NKKK, SNKK, SGS, Intertek or other
Surveyor company)s reports table & report are essential
to get an approval without exception.
What is meaning of the NKKKs stamp?
It means just NKKKs stamp for their report, not the approval
from the customs. NKKK also should submit their report to customs
to obtain the bureaus approval. It is same as SGS, SNKK, Intertek
13
Frequent Questions -2
How about times which required to obtain approval?
Is it same for all surveyor companies like SGS, SNKK,
NKKK, Intertek?
14
C lib ti
Calibration
HI
HI--TECH
- Please contact the below persons
:
kr.calibration@sgs.com
Jin.namgung@sgs.com
( MP : 82 17 552 0490,
T: 82 51 630 7061 )
14