Sie sind auf Seite 1von 9

Multi Split

Remark

Part Name

Dimensions

No.

6. Dimensions

AB-H1208VA0 [B120AH SV0]

6.1 Indoor units

Ducted Type

Air suction flange

Air discharge flange

Gas pipe connection

Liquid pipe connection

Power supply

/V/Hz

kW

Heating Capacity
Piping

Connections

117,000

Btu/h

Net cooling capacity

3 / 380 - 415 / 50
34.3

kW

Gross cooling capacity

32.8

Btu/h

112,000

kW
Btu/h

130,000

38.1

Liquid

mm(inch)

15.88(5/8)

Gas

mm(inch)

28.58(11/8)

mm

Drain(OD/ID)

34/28

Note
1. Unit should be installed in compliance with the
installation manual in the product box.
2. Unit shall be grounded in accordance with the local
regulations or applicable national codes.

Remark

Part Name

Dimensions

No.

6.2 Outdoor units

20

OUTDOOR UNIT
AB-H1208VA0 [B120AH SV0]

CHASSIS CODE: BV

Air discharge grille

Air suction grille

Gas pipe connection

Liquid pipe connection

Power & transmission connection

Ducted Type

Technical Specification

Power supply

/V/Hz

Gross cooling Capacity


Net cooling Capacity
Heating Capacity
Piping

Connections

kW
Btu/h
kW
Btu/h
kW
Btu/h

Liquid

mm(inch)

Gas

mm(inch)

CALOR SRL
Str. Progresului nr. 30-40, sector 5, Bucuresti
tel: 021.411.44.44, fax: 021.411.36.14
www.calorserv.ro - www.calor.ro
Note

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

CHASSIS CODE: UW

5CSDR-01B

50Hz, R22/R410A

LG Electronics

5CSDR-01B

LG Electronics

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at
different temperatures and fan speeds in individual rooms. The multi split system can be made up of large indoor
units for living areas and small indoor units for bedrooms, all operated from the one common outdoor unit.

Multi Split
High Efficiency Multi
1 High COP & Energy Saving
Inverter AC is same
Using LG
cone pines.
Coolingnting 138 big
pla
asHeating
4.6

4.3

4.1

4.0

37%

Using
LG Inverter AC is same as planting 138 big cone pines.
Cooling
Heating

4.16

For keeping Oil level in high Hz , Improved Oil circulation


system So.
LG inv. Multi can have high reliability system

100
80

DC motor
Approx

20%

increase
Approx

40%

AC motor

20 increase

0
200 300 400 500 600 700 800 900 1000
Motor Speed(rpm)

BLDC Fan motor

Adopt Oil Separate &

Axial Fan

138 big cone pines

Wide Louver tech

3 Step Axial fan shape can be available of high-effident &


low noise
Leading edge

1) KFRI(Korea Forest Research Institute) calculated based on annual power save.


(Assumption : Using AC 4hr/day, 365days)
2) Energy saving 37% was compared with LG Non-inverter model

Heat exchange rate(%)

(%)
C

128
123

DC Inverter Technology

Full range


Corrugate
fin


Wide
louver fin

-15

More Heat exchanger

Sine wave Control in BLDC Compressor

Height : 6%
Length : 8%

DC 380V
(Boost up)

DC280V

Partial switching

Static Pressure

Step-up Inverter by the PFC & the Sine Wave Control Technology
(PFC : Power Factor Correction)compared to conventional.

123%
100%


Improved heat

exchange rate by max
28%
+2%
Anti-corrosion treatment
+7%
+8%
(Gold
fin)
+5%

With the advancement of inverter technology comes more silent, economical and powerful air conditioning systems.
The LG air conditioner is manufactured using the PFC and the sine wave technology.

100%

128%

Condensing

Trailing edge

(COP)

Cooling
Heating

100

PFC Control in Power Input

Evaporation

Using LG Inverter AC

Loss

Optimize Oil Path

B Company

Condensing

A Company

Prevent Oil Discharge at High Hz !

BLDC Fan motor offers additional energy saving in


operating mode. Compared with AC motors, BLDC Fan
motor can cut energy by 35% at full velocity.

40

3.61

LG
H-Inverter

BLDC Fan Technology

60

4.12

3.70

Energy
Saving

MU3M19 MU3M21 MU4M25 MU4M27 MU5M30

3.72

5 High Reliability

3 Optimize Compression Eff.

3.8

4.46

4 Optimize Vibration, Noise

Evaporation

4.0

High Efficiency Motor

4.6

4.6

1 Minimized Oil circulation

Efficiency(%)

COP

In 2010, LG Inv. Multi New Model has Top class Energy Efficiency Model using LG BLDC Compressor, BLDC motor, high efficiency
heat exchanger.

4.4

The LG inverter air conditioner comes with a BLDC compressor that uses a strong neodymium magnet.
Its compressor thus has improved efficiency compared with AC inverter.

Top Class Energy Efficiency

4.8

Powerful BLDC Compressor

Energy Efficiency

Full range Sine wave switching

Loss

Full range

Rectangle wave

Sine wave
DC 380V
(Boost up)

DC280V
V

Before

After

35

Multi Split
2 Comfort Application

www.lgeaircon.com

www.lgeaircon.com

www.lgeaircon.com

LG Air Conditioner

LG Air Conditioner

LG Air Conditioner

from 1.5kWLG
Wide
LG RecomendAvailable
LG
theRecomend
1.5kW
the Recomend
1.5kW
the Operating
1.5kW Range
According to construction regulation, house wall is becoming When cooling computer rooms and other rooms in the event of low
the BLDC inverter compressor and outdoor
tothe
strenghten
insulation,Air
LG can
provide
solution outdoor
Air Conditionerthicker
Air
for&Conditioner
First
for
Conditioner
the right
First
for temperature,
the First
to small space.

1.5
kW

High static duct

1.5
kW

Don't you worry about


consumption for using
Big capacity in Small space?

1.5
kW

Don't you worry about


consumption for using
Big capacity in Small space?

Low static duct

BLDC fan motor are used to adjust the air flow and volume, with a view
to ensuring efficient operation by allowing the air conditioner to keep
operating at -10C without turning it off.
Indoor Temp(C)

The Variety of Various Combination

Don't you worry about

32 consumption for using


30

Low Ambient
Control

21

Convertible

18

Ceiling Cassette 4-Way

Ceiling Cassette 1-Way

Heating

10

15 Outdoor Units
46 Indoor Units

Wall Mounted

1.5

1.5

kW

1.5

kW

Cooling

Big capacity in Small space?

-15

-10

21

35

43

Outdoor Temp(C)

kW

Console

More than
2000 types

Artcool Gallery & Panel

Indoor Capacity Combination

2.6kW

Artcool Mirror

LiBERO

8.8kW

Max Combination

3.5kW

2.6kW

160%

Hero
*Common usage of Multi & SRAC Indoor unit
Libero : 9K~24K BTU
Hero : 9K~12K BTU
ART COOL : 9K~24K BTU

3.5kW

2.6kW

For Reference Sites

2.6kW
5.3kW

Max Combination

Max Combination

2.6kW

167%

7.0kW

2.6kW

3.5kW
2.6kW

Restaurant

Office

House

Building

3.5kW

163%

Multi Split
Long & High Elevation Piping
The FM56AH supports a piping length of up to 145m and high elevation of up to 30m for more flexibility in installation

*Multi Piping Type


Piping Length
(m)

15/
17k

30
20

Total
Max / Room

*Distributor Box Type


Outdoor unit

19k/
21k

25k/
27k

30k

40k

50
25

70
25

75
25

85
25

Allowable Elevation
(Indoor-Outdoor)
(Indoor-Indoor

15
7.5

15
7.5

15
7.5

15
7.5

15
7.5

Piping Length(m)
Total Pipe (A+L1+L2+L3)
Main Pipe(A)
50m
Total Branch Pipe (L1+L2+L3)
Each Branch Pipe
Allowable Elevation
Indoor-Outdoor (B)
Indoor-Indoor (C)

Outdoor unit

40k

48k

56k

100
50
50
15

135
55
80
15

145
55
90
15

30
15

Indoor unit

30
15

3 Comfort Operation & Ez installation

Noise Level
Library

32dB

Improved Low Noise


A

30m
15m

L2

Woods

The Inverter technology, the BLDC Motor technology, and LGs unique new
Skew Fan technology have achieved the worlds lowest noise level of 19dB.
Thus, the Sleep mode will allow pleasant sleeping.

Distributor

L1

L3

33dB

Conventional
On / Off

26dB
Conventional Inv.

22dB

Indoor unit

Indoor 19dB

LG Air Conditioner

30
15

19dB

Outdoor 45dB

*Only LIBERO_9k,12k

LG MV

Max 145m pipe run / 30m Elevation

Available to link with home network

Easy start-up, easy trouble shooting

Remove outdoor unit From Balcony and Move to car parking lot or Roof.

Monitoring the normality of all parts such as


compressor, fan, valve, etc

Beauty care center


Easy to get approval from council
Avoid safety issue (Baby fall down from balcony)

Internet

Command
Sensor reading
Home
Server
Air Conditioner

Living Room Light

Kitchen TV

Door Phone

Digital Door Lock

Emergency Switch

Motion Detect Sensor

Remote Switch

*LG does not supply home network. Only available to link.

Smart phone Solution for Operation monitoring & Trouble shooting


Internet

Home
Server

Smart phone connection


When faults have occurred, you can see the Error code during the check of indoor and
outdoor units, select the Error code, and find solutions to each problem through Q&A.
It is like the trouble shooting guide book embedded in the smart phone.
Air Conditioner

Living Room Light

Digital Door Lock

Emergency Switch

Kitchen TV

LG MV software on
Smart phone

Door Phone

Remote Switch

Operation Monitoring

RS-232

Troubleshooting on Smart phone

Select communication
method and language
Check the installation status
Compressor
operation status

1. Select Error Code


2. Easy Process

Wired

Bluetooth Module

3. Service Action

Check the indoor unit status


Operational status in line
with the frequency

Easy to Service
Easy & efficient installation of outdoor unit will provide the best solution for small offices and shops.

1. Inner SVC valve


- 4 Way piping is possible (Front, Rear,
- Excellent exterior

Right, Down)

2. Convenient moving handle

3. Compact Design & Ez SVC

- Fitted hand grips for easy


transportation and installation

- Remove 3 pieces of screw for SVC


- Front panel removal system

3 pieces
of screw

For Less 10 Floors

1 way

Ez SVC
4 way

Multi Split
Wide Range
LG Multi systems provide various indoor units and outdoor units up to 16.4kW. More than
2,000 types of combinations are available using 15 outdoor units and 48 indoor units

Multi Piping

Tyte

DB Box Type

Category

Model

MU2M15 UL0
MU2M17 UL0

MU3M19 UE0
MU3M21 UE0
MU4M25 UE0

MU4M27 U40
MU5M30 U40

MU5M40 UH0

FM40AH UH5

FM48AH U33
FM56AH U33

FM37AH UE0

FM41AH U33
FM49AH U33
FM57AH U33

Capacity
KW(C/H)

4.1/4.7
4.7/5.3

5.3/6.3
6.2/7.0
7.0/8.4

7.9/9.1
8.8/10.1

11.7/13.5

11.7/13.5

15.5/16.4
16.7/17.9

9.7/11.1

13.5/14.1
15.5/16.4
16.7/17.9

Max.
Indoor units

2
2

3
3
4

4
5

8
9

7
8
9

Phase

Free Combination with Various Indoor Types


Product

Ceiling Cassette Type

Wall Mounted Type


Wall Mounted

Mirror

Gallery

Panel

1-way

4-way

Ceiling Concealed Duct Type

Console

Ceiling &
Floor Type

MB09AHL N12

CQ09 NA0

MV09AH NE0

MB12AHL N12

CQ12 NA0

MV12AH NE0

CQ18 NA0

MV18AH NB0

Slim Duct

High

Capacity
Range
(kBtu/kW)

5/1.5

MS05AH N40

7/2.1

MS07AH N40

CS07AQ NB0

CS07AF NH0

CC07AW* NE3

9/2.6

MS09AH N40

CS09AQ NB0

CS09AF NH0

CC09AW* NE3

12/3.5

MS12AH N40

CS12AQ NB0

CS12AF NH0

18/5.3

MS18AH N50

CS18AQ NC0

24/7.0

MS24AH N50

CS05AF NH0

MT06AH NR0

CS24AQ NC0

MT08AH NR0

CC12AW* NE3

MA09AH1 NF1

MA12AH1 NF1

MA09AH* NF1

MA12AH* NF1

MT09AH NC1

MT10AH NR0

MT11AH NC1

MT12AH NR0

CC18AW* N83

MT18AH NQ0

CC24AW* N83

MT24AH NP0

Note : * indicates color of panel


*Blue(B) *Mirror(R) *Silver(V) *Red(E) *Gold(G) *White Silver(H) *Gallery(1)

MB18AHL N22

MB18AH NH0

MB24AHL N22

MB24AH NH0

MV24AH NB0

Specifications_Outdoor Units

Specifications_Outdoor Units

148

Dimensional drawings

Multi Split _

No.
1

Air

Ga

Liq

Po

Ea

SV

Mode
Power Supply

Cooling Capacity

Heating Capacity
Piping
Connections

MU2M15 UL0
MU2M17 UL0

MU3M19 UE0
MU3M21 UE0
MU4M25 UE0

ASSIS CODE : UL2

5RMI0-03A
Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total of Each Room
m
Piping Length
For One Room
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m

MU2M15 UL0

MU2M17 UL0

4,600~14,000~16,000
1.35~4.10~4.69
4,800~16,000~18,000
1.41~4.70~5.27
0.38~1.07~1.70
0.45~1.12~1.80
A/A

4,600~16,000~17,500
1.35~4.69~5.13
4,800~18,000~19,500
1.41~5.27~5.71
0.4~1.38~1.83
0.39~1.31~1.73
A/A

CS07AQ NB0 2EA

CS09AQ NB0 2EA

1.6~4.9~7.6
1.7~5.1~8.2
1 / 220~240 / 50
770545288 (30.321.511.3)
35(77.2)
2
1100(38.8)
28.2(995)
50
6.35(1/4)2EA
9.52(3/8)2EA
30
20
15
7.5

1.6~6.13~8.04
1.7~5.88~7.51
1 / 220~240 / 50
770545288 (30.321.311.3 )
40(88.2)
2
1300(42.3)
28.2(995)
50
6.35(1/4)2EA
9.52(3/8)2EA
30
20
15
7.5

Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB
- Outdoor Temperature 35C (95F) DB /24C (75.2F) WB
Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB
- Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. * : See page "Combination Table".
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

Model
Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

1. Unit should b
the product

Outdoor unit - DC Inverter SINGLE A (1, 3)

[Unit : mm]

Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

Note

(Unit:mm)

Model

Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total of Each Room
m
Piping Length
For One Room
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m

2. Unit should
applicable n

3. All electrical
must comply

(Unit:mm)

MU3M19 UE0

MU3M21 UE0

MU4M25 UE0

4,600~18,000~21,600
1.35~5.3~6.33
4,800~21,600~24,800
1.41~6.3~7.27
0.38~1.20~2.37
0.45~1.31~2.48
A/A

6,300~21,000~25,000
1.85~6.15~7.33
7,560~24,000~26,500
2.22~7.03~7.77
0.72~1.53~2.94
0.88~1.63~2.95
A/A

6,300~24,000~29,000
1.85~7.03~8.5
7,560~28,000~32,000
2.22~8.44~9.38
0.72~1.75~3.09
0.88~1.83~3.10
A/A

CS07AQ NB0 3EA

CS07AQ NB0 3EA

CS07AQ NB0 4EA

1.7~5.23~10.3
2.0~5.7~10.8
1 / 220~240 / 50
870808320 (34.331.812.6)
58(128)
3
2100(74.1)
53(1872)
52
6.35(1/4)3EA
9.52(3/8)3EA
50
25
15
7.5

3.1~6.65~12.7
3.8-7.1-12.8
1 / 220~240 / 50
870808320 (34.331.812.6)
61(134)
3
2300(81.13)
53(1872)
52
6.35(1/4)3EA
9.52(3/8)3EA
50
25
15
7.5

3.1~7.65~13.4
3.8~8.0~13.5
1 / 220~240 / 50
870808320 (34.331.812.6)
61(134)
4
2300(81.13)
53(1872)
52
6.35(1/4)4EA
9.52(3/8)4EA
70
25
15
7.5

Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB
- Outdoor Temperature 35C (95F) DB /24C (75.2F) WB
Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB
- Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. * : See page "Combination Table".
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

4. Electrical ch
work and de
breaker for o
characteristi

Multi Split _
5CSL0-05A

Outdoor unit - DC Inverter SINGLE A (1, 3)

Specifications_Outdoor Units

Specifications_Outdoor Units
OUTDOOR
OUTDOOR UNIT
UNIT

AUUW216DH [UU21WH
U4D]
A5UW406FA3
[FM38AH
UH3]
AUUW246DH [UU24WH U4D]

Liquid
pipe connection
Liquid pipe
connection

3
15

Remark
Remark

Air discharge
Air discharge
grille grille

Gas
pipe connection
Gas pipe
connection

370

Part Name
Part Name

175

Power & transmission connection

Power & transmission connection

370

15

395

Item No. No.

900
550

395

175

370

550

370

900

Earth screw

Earth screw

Main service valve(Liquid)

Main service valve(Gas)


7
Technical Specification

Liquid
Gas

1135

1165

50*4=200

50

3. All electrical components and materials to be supplied on the site

3. All electrical components and materials to be supplied on the site


must comply with the local regulations or international codes.
must 4.
comply
with the local regulations or international codes.
Electrical characteristics chapter should be considered for electrical

4. Electrical
characteristics
chapter should
be considered
for electrical
work
and design. Especially
the capacity
of power cable
and circuit
breaker
for Especially
outdoor unitthe
should
be more
than that
of electrical
work and
design.
capacity
of power
cable
and circuit
chapter.
breakercharacteristics
for outdoor unit
should be more than that of electrical
5. When pumping
down the system, use main service valve.
characteristics
chapter.

When you are installing the system, not used valve should be closed
by cap that equipped from factory.

MU5M40 UH0
CHASSIS CODE: UH

CHASSIS CODE: U4

Outdoor units_Multi piping type

Product data

MU4M27 U40

MU5M30 U40

6,300~27,000~32,400
1.85~7.91~9.49
7,560~31,000~36,000
2.22~9.08~10.55
0.72~1.98~3.12
0.88~1.97~3.68
A/A

6,300~30,000~36,000
1.85~8.80~10.55
7,560~34,500~41,400
2.22~10.1~12.1
0.72~2.31~3.16
0.88~2.19~3.87
A/A

CS07AQ NB0 4EA

CS07AQ NB0 5EA

3.1~8.6~13.5
3.8~9.0~16.0
1/220~240/50
950834330(37.432.813.0)
67(147.7)
4
3,300(116.4)
60(2119)
53
6.35(1/4)4EA
9.52(3/8)4EA
70
25
15
7.5

3.1~10.1~13.7
3.8~9.6~16.8
1/220~240/50
950834330(37.432.813.0)
67(147.7)
5
3,300(116.4)
60(2119)
53
6.35(1/4)5EA
9.52(3/8)5EA
75
25
15
7.5

Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB
- Outdoor Temperature 35C (95F) DB /24C (75.2F) WB
Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB
- Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. * : See page "Combination Table".
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

308

[Unit : mm]
(Unit:mm)

MU5M40 UH0

Model
Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

50

Dimensions

169

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total of Each Room
m
Piping Length
For One Room
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m

9.52(3/8)

2. Unit should
be grounded
in accordance
the local
regulations
2. Unit should
be grounded
in accordance
with with
the local
regulations
or or
applicable
national
applicable
national
codes.codes.

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

153
Btu/h
kW
Btu/h
kW
kW
kW

6.35(1/4)

mm(inch)

Note

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

mm(inch)

Part 2 Product data

[Unit : mm]
(Unit:mm)

Model

15.88
46,000

50

50
148

273

Liquid()
Gas()

9.52
13.5

9.52 kW

15.88Btu/h

1. Unit should be installed in compliance with the installation manual in


1. Unit should be installed in compliance with the installation manual in
the product
box. box.
the product

308

Note

mm

1 / 220-240 / 50

148

565

Piping

Connections

mm

Heating Capacity

1/ 220~240 / 50

Simultaneous
operation11.7
kW
Refer
to combination table
Btu/h
40,000

1165

kW

AUUW246DH [UU24WH U4D]

1135

kW

Cooling Capacity

Heating Capacity

/V/Hz

50*4=200

Cooling Capacity
Piping
Connections

1/ 220~240 / 50

520

MU4M27 U40
MU5M30 U40

AUUW216DH [UU21WH U4D]

/V/Hz

Power supply

273

520

Power Supply

565

Model name

Technical Specification

Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total of Each Room
m
Piping Length
For One Room
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m

9,600~40,000~46,000
2.8~11.7~13.5
11,040~46,000~51,000
3.2~13.5~15.0
1.1~3.63~4.65
1.4~3.65~4.84
A/A
MS09AH N40 5EA
6.2~16.0~20.0
6.9~16.4~20.5
1/220~240/50
9001165370(35.445.814.5)
95(209)
5
4,000(141.1)
53(1872)2
58
6.35(1/4)5EA
9.52(3/8)5EA
85
25
15
7.5

Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB
- Outdoor Temperature 35C (95F) DB /24C (75.2F) WB
Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB
- Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. * : See page "Combination Table".
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

Multi Split _
Product data

Specifications_Outdoor Units

OUTDOOR UNIT
A8UW486FA3[FM48AH U33]
A9UW566FA3[FM56AH U33]

900
175

2
3

Remark

Air discharge grille


Gas pipe connection
Liquid pipe connection

370

15

n connection

Part Name

No.

395

370

550

Part 2 Product data

336

Remark

1) Outdoor units

7UW406FA3[FM40AH UH3]

2.2.5 Dimensions

OUTDOOR UNIT

Specifications_Outdoor Units

Outdoor units_Distributor type(1)

Supporter
Technical Specification
Model Name

kW

Power supply

1 / 220-240 / 50

520

/V/Hz

11.7

Btu/h

40,000

kW
Btu/h

13.5

Cooling Capacity
Heating Capacity

46,000
19.05(3/4)

65

ordance with the local regulations or

16.7

Btu/h

52,800

57,000

kW
Btu/h

16.4

17.9

mm(inch)

56,000

61,000

Liquid()

9.52(3/8)

9.52(3/8)

Gas()

mm(inch)

19.05(3/4)

19.05(3/4)

FM48AH U33
FM56AH U33

3. All electrical components and materials to be supplied on the site


must comply with the local regulations or international codes.

124

80

273

er should be considered for electrical


e capacity of power cable and circuit
be more than that of electrical

308

Part 2 Product data

[Unit : mm]
[Unit : mm]

4. Electrical characteristics chapter should be considered for electrical


work and design. Especially the capacity of power cable and circuit
breaker for outdoor unit should be more than that of electrical
characteristics chapter.

[Unit : mm]

(Unit:mm)

(Unit:mm)
76, Seongsan-dong, Changwon City, Gyeongnam,
641-713, Korea
www.lge.com/airconditioner

FM40AH UH5

Model
Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

1. Unit should be installed in compliance with the installation manual in


the product box.
2. Unit should be grounded in accordance with the local regulations or
applicable national codes.

FM40AH UH5

materials to be supplied on the site


ulations or international codes.

CHASSIS CODE: UH

1 / 220-240 / 50

15.5

Note

pliance with the installation manual in

A9UW566FA3[FM56AH U33]

1 / 220-240 / 50

kW

1165

mm(inch)

Piping
Connections
1135

9.52(3/8)
565

mm(inch)

A8UW486FA3[FM48AH U33]
/V/Hz

Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total Piping
m
Piping Length
(Main+Total Branch)

Main Piping
m

Total Branch Piping
m

Each Branch Piping
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m
Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
Piping Length - Main piping 5m, Branch piping 5m
- Level Difference of Zero.
2. * : See page "Combination Table"
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

9,600~40,000~46,000
2.8~11.7~13.5
11,040~46,000~51,000
3.2~13.5~15.0
1.1~3.63~4.65
1.4~3.65~4.84
A/A
CS09AH NB0 7EA
6.2~16.0~20.0
6.9~16.4~20.5
1/220~240/50
9001165370(35.445.814.5)
95(209)
7
4,400(155)
53(1872) 2
58
9.52(3/8)
19.05(3/4)
100
50
50
15
30
15

CHASSIS CODE: U3

Model
Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total Piping
m
Piping Length
(Main+Total Branch)

Main Piping
m

Total Branch Piping
m

Each Branch Piping
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m

FM48AH U33

FM56AH U33

11,400~52,800~58,000
3.3~15.5~17.0
12,768~56,000~59,000
3.7~16.4~17.29
0.84~4.69~5.35
1.30~4.43~5.58
A/A
MS07AH N40 5EA
MS09AH N40 3EA
3.9~21.1~23.2
6.9~22.6~25.0
1/220~240/50
9501380330 (37.454.313.0)
108(238)
8
4800(169.3)
60(2,119) 2
58
9.52(3/8)
19.05(3/4)

13,800~57,000~63,200
4.0~16.7~18.52
15,456~61,000~64,000
4.5~17.9~18.75
1.0~4.96~5.65
1.25~4.62~5.70
A/A
4.6~21.7~24.0
7.4~22.4~26.0
1/220~240/50
9501380330 (37.454.313.0)
108(238)
9
4800(169.3)
60(2,119) 2
59
9.52(3/8)
19.05(3/4)

135

145

55
80
15
30
15

55
90
15
30
15

Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
Piping Length - Main piping 5m, Branch piping 5m
- Level Difference of Zero.
2. * : See page "Combination Table"
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

MS09AH N408EA

Outdoor

Multi Split _
5CSL0-05A

Outdoor unit - DC Inverter SINGLE A (1, 3)

Specifications_Outdoor Units

Part Name

No.
1
2

Remark

Air discharge grille


Part Name
No.Gas pipe connection

pipe
connection
1 Liquid Air
discharge
grille
2 Power Gas
& transmission
connection
pipe connection

3 Earth screw
Liquid pipe connection

Remark

1) Outdoor units

OUTDOOR UNIT
AUUW366D[UU36W UED]
A7UW428FA3[FM41AH U33]
AUUW368D[UU37W UED]
A8UW488FA3[FM49AH U33]
A9UW548FA3[FM57AH U33]

2.3.5 Dimensions

Specifications_Outdoor Units

SVC valve cover


Technical Specification

Supporter

A7UW428FA3

Cooling Capacity

/V/Hz/V/Hz

Cooling Capacity

Heating Capacity

Liquid
Piping Heating
Capacity
Connections
Gas
Piping
Connections

Note

A8UW488FA3

A9UW568FA3

AUUW368D[UU37W
UED]
AUUW366D[UU36W
UED]
[FM41AH U33]
[FM49AH
U33]
[FM57AH U33]

Model Name
Model name

Power Supply
Power supply

kW
kW

mm

50
31// 220~240
380-415 / /50

kW
Btu/h
kW

mm Btu/h

13.5

3/ 380~415
/ 50 / 50
3 / 380-415
3 / 380-415 / 50

Simultaneous15.7
operation
to combination
52,800 table

46,000
_Refer
14.1
9.52

48,000
15.88

16.4
56,000

Liquid()

mm(inch)

9.52(3/8)

9.52(3/8)

Gas()

mm(inch)

19.05(3/4)

19.05(3/4)

16.7
57,000

9.5217.87

61,000
15.88

9.52(3/8)

19.05(3/4)

Note

1. Unit should be installed in compliance with the installation manual in


1. Unit should
the product
box. be installed in compliance with the installation manual in
the product box.

2. Unit should be grounded in accordance with the local regulations or


2. Unit national
should becodes.
grounded in accordance with the local regulations or
applicable
applicable national codes.

3. All electrical components and materials to be supplied on the site


All electrical components and materials to be supplied on the site
must3.comply
with the local regulations or international codes.
must comply with the local regulations or international codes.

FM37AH UE0
[Unit : mm]

(Unit:mm)

CHASSIS CODE: U3

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

OUTDOOR UNIT

Outdoor units_Distributor type(3)

149

Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

Product data

FM37AH UE0

Model
Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total Piping
m
Piping Length
(Main+Total Branch)

Main Piping
m

Total Branch Piping
m

Each Branch Piping
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m
Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
Piping Length - Main piping 5m, Branch piping 5m
- Level Difference of Zero.
2. * : See page "Combination Table"
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

21,600~33,000~37,000
6.33~9.67~10.8
22,800~38,000~42,000
6.68~11.1~12.3
1.80~3.00~3.45
1.83~3.05~3.51
A/A
MS07AH N40 6EA
3.4-5.4-6.0
3.5-5.4-6.1
3 / 380~415 / 50
8701,038320 (34.340.912.6)
80(176)
6
2,800(98.8)
32(1,130) 2
51/47
6.35(1/4)
15.88(5/8)
100
40
60
20
30
15

Model
Nominal Capacity*
Cooling
(Min~Rated~Max)

Heating

Nominal Input*
Cooling
(Min~Rated~Max)
Heating
Energy label
Testing Combination

[Unit : mm]

(Unit:mm)

Dimensions

381

FM41AH U33
FM49AH U33
FM57AH U33

Part 2 Product data

4. Electrical characteristics chapter should be considered for electrical


4. Electrical characteristics chapter should be considered for electrical
work and
design.
Especially
the capacity
of power
cable
andand
circuit
work
and design.
Especially
the capacity
of power
cable
circuit
breakerbreaker
for outdoor
unit should
be more
thanthan
thatthat
of electrical
for outdoor
unit should
be more
of electrical
characteristics
chapter.
characteristics chapter.

Btu/h
kW
Btu/h
kW
kW
kW

Running Current
Cooling
A
(Min~Rated~Max)
Heating
A
Power Supply
/ V / Hz
Dimensions
W*H*D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Refrigerant
Charge (at 7.5m)
g(oz)
Air Flow Rate
CMM(CFM)
Sound Level
Sound Pressure at 1m
dB(A)+3
Piping connections
Liquid()
mm(inch)

Gas()
mm(inch)
Max. Interunit
Total Piping
m
Piping Length
(Main+Total Branch)

Main Piping
m

Total Branch Piping
m

Each Branch Piping
m
Max. Elevation
Indoor Unit~Outdoor Unit
m

Indoor Unit~Indoor Unit
m

FM41AH U33

FM49AH U33

FM57AH U33

9,600~46,000~48,000
2.8~13.5~14.1
10,752~48,000~52,000
3.2~14.1~15.2
0.8~4.0~4.9
0.89~3.9~5.1
A/A

13,800~57,000~63,200
4.0~16.7~18.52
15,456~61,000~64,000
4.5~17.87~18.75
1.0~4.91~5.7
1.49~4.55~5.65
A/A

1.5~7.2~8.1
1.7~7.5~8.0
3/380~415/50
9501380330 (37.454.313.0)
108(238.0)
7
4,800(169.3)
60(2,119) 2
58
9.52(3/8)
19.05(3/4)

11,400~52,800~58,000
3.3~15.5~17.0
12,768~56,000~59,000
3.7~16.4~17.29
0.94~4.6~5.4
1.13~4.45~5.2
A/A
MS07AH N40 5EA +
MS09AH N40 3EA
1.8~8.0~8.4
2.1~7.5~8.3
3/380~415/50
9501,380330 (37.454.313.0)
108(238.0)
8
4,800(169.3)
60(2,119) 2
58
9.52(3/8)
19.05(3/4)

2.3~8.1~9.1
2.5~8.0~8.7
3/380~415/50
9501,380330 (37.454.313.0)
108(238.0)
9
4,800(169.3)
60(2,119) 2
59
9.52(3/8)
19.05(3/4)

125

135

145

55
70
15
30
15

55
80
15
30
15

55
90
15
30
15

MS07AH N40 7EA

Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
Piping Length - Main piping 5m, Branch piping 5m
- Level Difference of Zero.
2. * : See page "Combination Table"
3. Due to our policy of innovation some specifications may be changed without notification.
4. At least two indoor units should be connected.
5. Minimum combination capacity rate should be more than 40%.

MS09AH N408EA