Sie sind auf Seite 1von 62

OptiX OSN 1800 Compact Multi-Service Edge

Optical Transport Platform


V100R003C01SPC300

Release Notes

Issue

01

Date

2013-01-10

HUAWEI TECHNOLOGIES CO., LTD.

Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address:

Huawei Industrial Base


Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website:

http://www.huawei.com

Email:

support@huawei.com

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Contents

Contents
1 Version Mapping...........................................................................1
1.1 Product Version..................................................................................................................................................1
1.2 Software Versions..............................................................................................................................................1
1.3 Board Versions...................................................................................................................................................2
1.4 Virus Scan Result...............................................................................................................................................5

2 Version Compatibility....................................................................7
2.1 Compatibility with Earlier Product Versions.....................................................................................................7

3 What's New..................................................................................8
3.1 V100R003C01SPC300......................................................................................................................................8
3.1.1 Feature Updates........................................................................................................................................8
3.1.2 Hardware Updates....................................................................................................................................9
3.1.3 Alarm Updates........................................................................................................................................10
3.1.4 Performance Event Updates...................................................................................................................10
3.2 V100R003C01SPC200....................................................................................................................................11
3.2.1 Feature Updates......................................................................................................................................11
3.2.2 Hardware Updates..................................................................................................................................13
3.2.3 Alarm Updates........................................................................................................................................13
3.2.4 Performance Event Updates...................................................................................................................13
3.3 V100R003C01SPC100....................................................................................................................................14
3.3.1 Feature Updates......................................................................................................................................14
3.3.2 Hardware Updates..................................................................................................................................16
3.3.3 Alarm Updates........................................................................................................................................16
3.3.4 Performance Event Updates...................................................................................................................17
3.4 V100R003C01.................................................................................................................................................17
3.4.1 Feature Updates......................................................................................................................................18
3.4.2 Hardware Updates..................................................................................................................................19
3.4.3 Alarm Updates........................................................................................................................................20
3.4.4 Performance Event Updates...................................................................................................................21
3.5 V100R003C00SPC200....................................................................................................................................21
3.5.1 Feature Updates......................................................................................................................................22
3.5.2 Hardware Updates..................................................................................................................................22
3.5.3 Alarm Updates........................................................................................................................................22
Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

ii

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Contents

3.5.4 Performance Event Updates...................................................................................................................23


3.6 OptiX OSN 1800 V100R003C00SPC100.......................................................................................................23
3.6.1 Feature Updates......................................................................................................................................23
3.6.2 Hardware Updates..................................................................................................................................24
3.6.3 Alarm Updates........................................................................................................................................25
3.6.4 Performance Event Updates...................................................................................................................26
3.7 OptiX OSN 1800 V100R003C00....................................................................................................................26
3.7.1 Feature Updates......................................................................................................................................27
3.7.2 Hardware Updates..................................................................................................................................28
3.7.3 Alarm Updates........................................................................................................................................28
3.7.4 Performance Event Updates...................................................................................................................29

4 Resolved Issues and Known Issues...............................................30


4.1 Resolved Issues................................................................................................................................................30
4.1.1 V100R003C01SPC300...........................................................................................................................30
4.1.2 V100R003C01SPC200...........................................................................................................................35
4.1.3 V100R003C01SPC100...........................................................................................................................36
4.1.4 V100R003C01........................................................................................................................................37
4.1.5 V100R003C00SPC200...........................................................................................................................37
4.1.6 V100R003C00SPC100...........................................................................................................................38
4.1.7 V100R003C00........................................................................................................................................38
4.2 Known Issues...................................................................................................................................................38

5 Important Notes.......................................................................... 46
5.1 Hardware..........................................................................................................................................................46

6 Upgrade Impact..........................................................................47
6.1 Impact Checklist..............................................................................................................................................47
6.2 Impact During Upgrade and Rollback.............................................................................................................48
6.2.1 Impact of an Upgrade from V100R003C01SPC200..............................................................................49
6.2.2 Impact of an Upgrade from V100R003C01SPC100..............................................................................49
6.2.3 Impact of an Upgrade from V100R003C00SPC100..............................................................................50
6.2.4 Impact of an Upgrade from V100R003C00SPC200..............................................................................51
6.2.5 Impact of an Upgrade from V100R003C00...........................................................................................52
6.3 Impact on the System After the Upgrade.........................................................................................................52
6.3.1 Impact on Equipment Maintenance........................................................................................................52
6.3.2 Impact on Service Configuration............................................................................................................52
6.3.3 Impact on Alarm and Performance Event Reporting..............................................................................53
6.3.4 Impact on Security..................................................................................................................................53

7 Related Documents.....................................................................54
7.1 V100R003C01 SPC300Documents.................................................................................................................54
7.2 Obtain Documents...........................................................................................................................................54
7.2.1 Support Website......................................................................................................................................54
Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

iii

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Contents

7.2.2 Hard Copies............................................................................................................................................55

A Acronyms and Abbreviations.......................................................56

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

iv

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

1 Version Mapping

Version Mapping

This chapter lists the version information for the OptiX OSN 1800 V100R003C01SPC300
and the network management system (NMS), NE software, and hardware that are required for
the OptiX OSN 1800 V100R003C01SPC300.

1.1 Product Version


Table 1.1 lists the version information for the product.
Table 1.1 Product version
Product Name

OptiX OSN 1800 Compact Multi-Service Edge Optical Transport


Platform

Product
Version

V100R003C01SPC300

1.2 Software Versions


Table 1.1 lists the software versions that are required for the current product version.
Table 1.1 Software versions
Software

Version

NE software

5.67.03.25

NMS software

iManager U2000 V100R006C00

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

1 Version Mapping

1.3 Board Versions


Table 1.1 lists the board versions that are required for the current product version.
Table 1.1 Board versions
Board Type

Board
Name

Softwa
re
Version

FPGA or
CPLD
Version

BIOS or
Extended BIOS
Version

PCB
Version

System control and


communication unit
(SCC)

TNF1SCC

5.67.03.25

FPGA: 300

EXT-BIOS: 9.27.25

VER.B or
VER.D

Backplane

Optical transponder
unit (OTU)

BIOS: 8.27.25
TNF1CTL

N/A

N/A

N/A

VER.A

TNF1AFBS

N/A

N/A

N/A

VER.A

TNC1AFB

N/A

N/A

N/A

VER.A

TND1AFB

N/A

N/A

N/A

VER.A

TNF1LQM

N/A

FPGA: 120

N/A

VER.B

TNF1LQM2

N/A

FPGA: 120

N/A

VER.B

TNF1LDGF

N/A

FPGA: 120

N/A

VER.C

TNF1LDGF2

N/A

FPGA: 120

N/A

VER.B

TNF1LQG

N/A

FPGA: 120

N/A

VER.B

PL271:200
PL276:200
SERDES: 110
TNF1LWX2

N/A

FPGA: 120

N/A

VER.B

TNF1LSPU

N/A

FPGA: 120

N/A

VER.B

TNF1LSPL

N/A

FPGA: 120

N/A

VER.B

TNF1LSPR

N/A

FPGA: 120

N/A

VER.B

TNF1LOE

N/A

FPGA: 130

N/A

VER.B

PL286*: 210
PL322**: 130
TNF1LSX

N/A

FPGA: 120

N/A

VER.A

TNF1LQPL

N/A

FPGA: 120

N/A

VER.C

TNF1LQPU

N/A

FPGA: 120

N/A

VER.C

N/A

VER.B

CPLD: 100
TNF1LDE

Issue 01 (2013-01-10)

N/A

FPGA: 100

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Board Type

Board
Name

Softwa
re
Version

FPGA or
CPLD
Version

1 Version Mapping

BIOS or
Extended BIOS
Version

PCB
Version

N/A

VER.A

N/A

VER.A

FPGA: 120

EXT-BIOS: 1.16

BDCPLD: 100

BIOS: 1.08

VER.A
(TNF1LEM1
8A)

PL320*: 120
PL323**: 120
TNF1TSPA

N/A

FPGA: 110
CPLD: 110

TNF1TSPB

N/A

FPGA: 110
CPLD: 110

TNF1LEM18

1.07

VER.A
(TNF1LEM1
8B)

POWER1220:
100
TNF2ELOM

N/A

FPGA: 200

N/A

CPLD: 110

VER.A
(TNF2ELOM
C)
VER.B
(TNF2ELOM
B)

TNF1LDX

N/A

FPGA: 110

N/A

VER.A

N/A

VER.A

N/A

VER.A

N/A

VER.A

N/A

VER.A

N/A

VER.A

CPLD: 110
TNF2LQM

N/A

FPGA: 100
CPLD: 110

TNF2LQM2

N/A

FPGA: 100
CPLD: 110

TNF2LSX

N/A

FPGA: 110
CPLD: 110

TNF2LDGF2

N/A

FPGA: 100
CPLD: 110

TNF1ELQM

N/A

FPGA: 110
CPLD: 120

Two-fiber
bidirectional OADM
board for the
DWDM/CWDM

Issue 01 (2013-01-10)

TNF1MR1

N/A

N/A

N/A

VER.A

TNF1MR1S

N/A

N/A

N/A

VER.A

TNF1MR2

N/A

N/A

N/A

VER.A

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

1 Version Mapping

Board Type

Board
Name

Softwa
re
Version

FPGA or
CPLD
Version

BIOS or
Extended BIOS
Version

PCB
Version

system

TNF1MR2S

N/A

N/A

N/A

VER.A

TNF1MR4

N/A

N/A

N/A

VER.A

Two-fiber
bidirectional OADM
board for the
DWDM system

TNF1MR8

N/A

N/A

N/A

VER.A

TNF1SBM8

N/A

N/A

N/A

VER.A

Two-fiber
bidirectional OADM
board for the
CWDM system

TNF1MD8

N/A

N/A

N/A

VER.A

TNF1MD8S

N/A

N/A

N/A

VER.A

TNF1SBM4

N/A

N/A

N/A

VER.A

TNF1MR4S

N/A

N/A

N/A

VER.A

Single-fiber
bidirectional OADM
board for the
DWDM/CWDM
system

TNF1SBM1

N/A

N/A

N/A

VER.A

TNF1SBM2

N/A

N/A

N/A

VER.A

Two-fiber
bidirectional OADM
board for the
DWDM/CWDM
system

TNF1DMD1

N/A

N/A

N/A

VER.A

TNF1DMD2

N/A

N/A

N/A

VER.A

Two-fiber
bidirectional OADM
board for the
CWDM system

TNF1DMD1
S

N/A

N/A

N/A

VER.A

TNF1DMD2
S

N/A

N/A

N/A

VER.A

Protection board

TNF1OLP

N/A

FPGA: 120

N/A

VER.B

TNF1SCS

N/A

N/A

N/A

VER.A

Optical multiplexing
and demultiplexing
board

TNF1FIU

N/A

N/A

N/A

VER.A

40-channel
multiplexing and
demultiplexing
board

TNF1X40

N/A

N/A

N/A

VER.A

Optical amplifier
board

TNF1OPU

N/A

FPGA: 120

N/A

VER.A

TNF1OBU

N/A

FPGA: 120

N/A

VER.A

Power supply board

TNC1PIU

N/A

N/A

N/A

VER.A

TND1PIU

N/A

N/A

N/A

VER.A

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Board Type

Fan board

1 Version Mapping

Board
Name

Softwa
re
Version

FPGA or
CPLD
Version

BIOS or
Extended BIOS
Version

PCB
Version

TNF1APIU

N/A

N/A

N/A

VER.A

TNF1FAN01

N/A

N/A

N/A

VER.A

TNF1FAN02

N/A

N/A

N/A

VER.A

NOTE
For the TNF1LDE and TNF1LOE boards, the displayed complex programmable logic device (CPLD) version is the sum of the
version numbers marked with one asterisk (*) and two asterisks (**). Take the TNF1LOE board for example. The version
number of PL286 (marked with *) is 210 and the version number of PL322 (marked with **) is 130; therefore, the displayed
CPLD version of the TNF1LOE board is 340 (210 + 130).

1.4 Virus Scan Result


The software package has been scanned by antivirus software. No risk is found. The details
are as follows:
Antivirus Software Name

McAfee

Antivirus Software
Version

5400.1158

Antivirus Database
Version

6948.0000

When to Scan

2013-1-7

Result

No risk found

Antivirus Software Name

OfficeScan

Antivirus Software
Version

10.5.1103

Antivirus Database
Version

9.642.60

When to Scan

2013-1-7

Result

No risk found

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

1 Version Mapping

Antivirus Software Name

Symantec

Antivirus Software
Version

12.1.1101.401

Antivirus Database
Version

3954179 r3

When to Scan

2013-1-7

Result

No risk found

Antivirus Software Name

Kaspersky

Antivirus Software
Version

v13.0.1.4190(e)

Antivirus Database
Version

2013-1-9

When to Scan

2013-1-9

Result

No risk found

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Version Compatibility

This chapter describes the compatibility between the current product version and the earlier
product versions of the OptiX OSN 1800.

2.1 Compatibility with Earlier Product Versions


The current version is compatible with all the earlier official versions of the product:

OptiX OSN 1800 V100R001C01 and associated patch versions

OptiX OSN 1800 V100R001C02 and associated patch versions

OptiX OSN 1800 V100R002C00 and associated patch versions

OptiX OSN 1800 V100R003C00 and associated patch versions

OptiX OSN 1800 V100R003C01 and associated patch versions

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

What's New

This chapter describes the updates in each version of the OptiX OSN 1800.

3.1 V100R003C01SPC300
3.1.1 Feature Updates
New Features
No.

Description

Purpose

The TNF2LSX, TNF1LDX, and


TNF2ELOM boards support SFP+
modules on the client side to transmit
services over 40 km.

The boards with SFP+ modules can


provide service access over a longer
distance.

A TNF1SCC board is equipped with


an OSC module to transmit services
over 80 km or 150 km.

The board with an OSC module can


provide service transmission over a longer
distance.

Modified Features
No.

Description

Reason

Impact

Loopback configuration on
the WDM side of a
TNF2LSX, TNF2ELOM,
or TNF1LDX board is not
allowed when the board is
configured with intra-board
1+1 or SNCP protection.

When the specified


protection is configured
for the board, the
loopback configurations
on the WDM side of the
board conflict with the
protection configurations.

Loopback on the WDM


side cannot be
configured if the
TNF2LSX,
TNF2ELOM, or
TNF1LDX board is
configured with intraboard 1+1 or SNCP
protection.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

No.

Description

Reason

Impact

If a
TNF1LSX/TNF2LSX/TNF
1LDX/TNF2ELOM board
reports a LOCAL_FAULT
alarm when
receiving/transmitting
10GE services, an
REM_SF alarm is reported
on the client-side port of a
downstream board that
interconnects with the
board on the WDM side. If
the downstream board is
configured with client-side
1+1 protection, the
REM_SF alarm triggers
protection switching.

A more robust protection


switching mechanism is
provided when the board
is receiving/transmitting
10GE services.

If a
TNF1LSX/TNF2LSX/T
NF1LDX/TNF2ELOM
board reports a
LOCAL_FAULT alarm
when
receiving/transmitting
10GE services, an
REM_SF alarm is
reported on the clientside port of a
downstream board that
interconnects with the
board on the WDM
side. If the downstream
board is configured with
client-side 1+1
protection, the REM_SF
alarm triggers
protection switching.

The protocol for accessing


NEs using web is changed
from HTTP to HTTPS.

After the protocol


change, accessing NEs
using web is protected in
a more secure manner.

The protocol for


accessing NEs using
web is changed.

Deleted Features
None

3.1.2 Hardware Updates


New Hardware
None

Modified Hardware
None

Deleted Hardware
None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.1.3 Alarm Updates


New Alarms
Alarm Name

Description

INPWR_FAIL

Indicates an input power failure of an APIU board.

OUTPWR_FAIL

Indicates an output power failure of an APIU board.

PWR_TEMP_HIGH

Indicates that the temperature of the power module on


an APIU board is excessively high.

Modified Alarms
Alarm Name

Description

PWR_TEMP_OVERTH

Indicates that the working temperature of an APIU


board exceeds the threshold. The alarm display
interface is optimized.

POWER_MODULE_OFFLINE

Indicates that the power module of an APIU board is


offline. The alarm display interface is optimized.

ODU0_PM_AIS

The following attributes are modified for these alarms:

ODU1_PM_AIS

Monitoring status: not monitoring

ODU2_PM_AIS

Reporting status: not reported by default

ODU5G_PM_AIS

Alarm level: warning

ODUFLEX_PM_AIS
OTU1_AIS, OTU2_AIS
OTU5G_AIS
OUT_PWR_HIGH
OUT_PWR_LOW

The reporting attribute of the two alarms is modified


to not reported by default.

Deleted Alarms
Alarm Name

Description

POWER_FAIL

The APIU POWER_FAIL alarm is replaced by the


INPWR_FAIL and OUTPWR_FAIL alarms.

3.1.4 Performance Event Updates


New Performance Events
None
Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

10

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Modified Performance Events


None

Deleted Performance Events


None

3.2 V100R003C01SPC200
This section describes the updates in V100R003C01SPC200 compared with
V100R003C01SPC100.

3.2.1 Feature Updates


New Features
No.

Description

Purpose

The following boards


support bidirectional
automatic laser
shutdown (ALS):

The OptiX OSN 1800 provides the bidirectional ALS


function. Thanks to this function, client equipment
connected to the OptiX OSN 1800 at both ends will
switch services to the backup network for transmission
when a failure occurs on the client side or WDM side of
an OTU board on the OptiX OSN 1800.

TNF1LSX

TNF2LSX

TNF1LDX

TNF2ELOM

TNF2LQM

TNF2LDGF2

TNF2LQM2

TNF1ELQM

TNF1LDGF

TNF2LDGF2

TNF1LQM

TNF1LQM2

The TNF1APIU board


reports an event in case
of a power failure.

Non-GNEs that are powered by the TNF1APIU boards


will be unreachable by the NMS once the boards
undergo a power failure. This new feature enables the
non-GNEs to report an NE-DYING-EVENT in this
situation so that users can know why these non-GNEs
are unreachable by the NMS.
This feature applies only to non-gateway NEs that use
ESC communication. When using this feature, take the
following precautions regarding hardware
configurations:
Power failure events are reported only when both the
TNF1APIU board and the two power modules have the
PCB version of VER.B. The TNF1APIU board with the

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

11

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

No.

Description

7 Related Documents

Purpose
PCB version of VER.B is incompatible with a power
module with the PCB version of VER.A, and is
compatible only with a power module with the PCB
version of VER.B.
The TNF1APIU board with the PCB version of VER.A
is compatible with the power modules with the PCB
versions of VER.A and VER.B.

The following boards


support SONET
services:

TNF1LSX

TNF2LSX

TNF1LDX

TNF2LQM

TNF2LQM2

TNF1ELQM

TNF2ELOM

The boards listed in the Description column support


SONET services so that the boards can transmit and
receive a wider range of services.

The TNF1LEM18 board


supports ODU2 SNCP
protection.

The TNF1LEM18 board supports OTN extended model


and SNCP protection, and provides protection for lineside services.

Users can set the holdoff time, which is the


period that the ALS
function delays turning
on lasers.

Users can set the hold-off time that the ALS function
delays turning on lasers on the client sides of the
following boards:

Issue 01 (2013-01-10)

The OptiX OSN 1800


2U equipment can
monitor the external 1U
high AC/DC power
module (S4815AF)
through a serial port.

TNF1LSX

TNF2LSX

TNF1LDX

TNF2ELOM

TNF2LQM

TNF2LDGF2

TNF2LQM2

TNF1ELQM

TNF1LDGF

TNF1LDGF2

TNF2LDGF2

TNF1LQM

TNF1LQM2

The external power module (S4815AF) can be


monitored.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

12

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Modified Features
None

Deleted Features
None

3.2.2 Hardware Updates


New Hardware
None

Modified Hardware
None

Deleted Hardware
None

3.2.3 Alarm Updates


New Alarms
Alarm Name

Description

LAN_LOC

Indicates an Ethernet communication failure.

DBMS_DELETE

Indicates that the NE database is being deleted.

PASSWORD_NEED_CHANGE

Indicates that the password of the default user account


must be changed to prevent risks of security.

SSL_CERT_NOENC

Indicates that the SSL certificate file is not encrypted.

Modified Alarms
None

Deleted Alarms
None

3.2.4 Performance Event Updates


New Performance Events
None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

13

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Modified Performance Events


None

Deleted Performance Events


None

3.3 V100R003C01SPC100
The feature updates of V100R003C01SPC100 compared with V100R003C01 are as follows.

3.3.1 Feature Updates


New Features
No.

Description

Purpose

Precision Time Protocol (PTP)


as defined in IEEE 1588

Equipment with the PTP function can achieve


networkwide frequency synchronization and time
synchronization in a packet switching network
(PSN). A carrier network transmits various
services, some of which require time
synchronization of high precision. Such services
include net voting and billing. The PTP-based
clock is mainly used in such scenarios to meet the
requirement for time synchronization of high
precision.

Intra-board 1+1 protection is


supported on the following
boards:

Intra-board 1+1 protection uses the dual feeding


selective receiving function and separate routes to
provide protection for OCh fibers.

Issue 01 (2013-01-10)

TNF1ELQM

TNF1LDX

TNF2ELOM

TNF2LDGF2

TNF2LQM

TNF2LQM2

TNF2LSX

The LEM18 board supports


service-based LPT.

Service-based LPT applies to the service access


points at both ends of a service network. It tracks
the state of a link that carries important services
so that the service access points promptly respond
to the link state changes. If a fault occurs on the
link that carries important services, the LPT
function ensures that the services are promptly
switched to the backup network.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

14

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

No.

Description

Purpose

The ELOM board supports the


ODUk ADM function.

In 1*AP8 general mode, the ELOM board


supports a maximum of 20 Gbit/s service
grooming and transparent transmission of 10
Gbit/s ODUk services between the east and west
directions.

The commissioning tool of the


access WDM OTN is
supported.

The commissioning tool of the access WDM


OTN can be used to configure basic NE
attributes, perform optical power commissioning,
and configure basic NE functions such as ECC.

Modified Features
No.

Description

Reason

Impact

For the ELOM board, "1*AP2


ODUflex mode" is changed to
"1*AP1 ODUflex mode."

For the ELOM board, only the


RX1/TX1 port supports
ODUflex services.

None

Deleted Features
No.

Description

Reason

Impact

Client-side optical
ports RX5/TX5 and
RX7/TX7 on the
ELOM board do not
support GCC
communication.

An OptiX OSN 1800 2 U subrack


supports a maximum of 24 GCC
channels. When the subrack is fully
configured with six ELOM boards
and each ELOM board provides six
GCC channels, the maximum number
of GCC channels provided by ELOM
boards is greater than the maximum
number of GCC channels supported
by the subrack.

GCC
communication is
unavailable at
client-side optical
ports RX5/TX5
and RX7/TX7 on
the ELOM board.

WDM-side optical
ports IN2/OU2 and
IN4/OU4 on the
TNF1LDX board do
not support GCC
communication.

An OptiX OSN 1800 2 U subrack


supports a maximum of 24 GCC
channels. When the subrack is fully
configured with six LDX boards and
each LDX board provides six GCC
channels, the maximum number of
GCC channels provided by LDX
boards is greater than the maximum
number of GCC channels supported
by the subrack.

GCC
communication is
unavailable at
WDM-side
optical ports
IN2/OU2 and
IN4/OU4 on the
TNF1LDX
board.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

15

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.3.2 Hardware Updates


New Hardware
Name

Description

TNF1ELQM

Enhanced 4 x multi-rate ports wavelength conversion board. The WDM


side supports dual feeding selective receiving and OTU1 IEEE 1588v2
functions. The client side supports GE services.

Modified Hardware
None

Removed Hardware
None

3.3.3 Alarm Updates


New Alarms
Alarm Name

Description

SHELF_AREA_POWER_OVER

The total optical power consumption of the subrack


exceeds the threshold

LPT_ACTIVE

LPT switching occurred alarm

TIME_LOS

Loss of the time source

EXT_TIME_LOC

Loss of the external time source

TIME_NO_TRACE_MODE

Tracing of the local time source

PTP_SOURCE_SWITCH

Switching of the IEEE 1588v2 time source

PTP_TIMESTAMP_ABN

Unchange of the time stamp

CLK_LOCK_FAIL

Clock (frequency) unlocking

TIME_LOCK_FAIL

Time unlocking

FOP_NR

Protection group not receiving negotiation response


from the peer end

FOP_PM

Protection protocol information inconsistency

Modified Alarms
None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

16

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Deleted Alarms
None

3.3.4 Performance Event Updates


New Performance Events
Performance Event
Name

Description

MAXFREQDEV

Maximum frequency deviation from the output clock and


the reference clock source for the input clock

MINFREQDEV

Minimum frequency deviation from the output clock and


the reference clock source for the input clock

AVGFREQDEV

Average frequency deviation from the output clock and the


reference clock source for the input clock

MAXMEANPATHDELAY

Maximum path delay between the master clock and slave


clock

MINMEANPATHDELAY

Minimum path delay between the master clock and slave


clock

AVGMEANPATHDELAY

Average path delay between the master clock and slave


clock

MAXPHASEOFFSET

Maximum phase offset between the master clock and slave


clock

MINPHASEOFFSET

Minimum phase offset between the master clock and slave


clock

AVGPHASEOFFSET

Average phase offset between the master clock and slave


clock

Modified Performance Events


None

Deleted Performance Events


None

3.4 V100R003C01
This section describes the updates in V100R003C01 compared with V100R003C00SPC200.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

17

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.4.1 Feature Updates


New Features
No.

Description

Purpose

001

The OptiX OSN 1800


supports VLAN SNCP
protection.

To provide protection for Ethernet services.


A service under VLAN SNCP protection is dually fed
at the transmit end and selectively received at the
receive end.
This feature applies to transport networks with low
delay and low jitter to provide carrier-class protection
for large volumes of Ethernet private line traffic.

002

The OptiX OSN 1800


supports the ETH-OAM
(IEEE 802.3ah)
function.

As a protocol based on the MAC layer, ETH-OAM


(IEEE 802.3ah) detects faults on Ethernet links and
monitors link performance using OAM protocol
packets. In addition, it can trigger remote loopbacks for
fault location. ETH-OAM (IEEE 802.3ah) is irrelevant
to transmission medium. OAM packets sent by ETHOAM (IEEE 802.3ah) are processed only at the MAC
layer. ETH-OAM (IEEE 802.3ah) is a low-rate
protocol, requiring small bandwidth and therefore
having no impact on services over the Ethernet links.

003

The OptiX OSN 1800


supports both the
Spanning Tree Protocol
(STP) and Rapid
Spanning Tree Protocol
(RSTP).

The STP and RSTP apply to looped networks and


provide path redundancy using specific algorithms. By
using the STP or RSTP, a looped network can be
trimmed into a tree network without any loop. This
feature prevents the proliferation and endless cycling of
packets in the looped network, and therefore prevents a
broadcast storm and MAC address flapping in the
network.
When a loop is caused in an Ethernet network topology,
the STP or RSTP must be enabled.

004

The OptiX OSN 1800


can encapsulate and
cross-connect ODUflex
signals.

To improve service grooming capability.


In addition to providing alarm management, this feature
enables encapsulation, mapping, grooming, and
protection for ODUflex services.
By using this technology, users can flexibly configure
ODUk based on the service capacity, therefore fully
using the line bandwidth.

005

The OptiX OSN 1800


supports ODUk SNCP
protection.

ODUk subnetwork connection protection (SNCP) uses


the dual feeding and selective receiving function
implemented by using electrical cross-connections on
OTU boards to protect services on ODUk channels. (K
= 0, 1, flex, 2)
ODUk SNCP protection has no restriction on the
network topology. It can be applied to protect ODUk
channels if there are vacant ODUk channels.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

18

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

No.

Description

Purpose

006

The OptiX OSN 1800


supports query of power
consumption for each
board.

With this function, users can quickly learn about the


power consumption of a subrack, facilitating
management of subrack energy consumption.

007

The OptiX OSN 1800


supports board version
replacement by
switching board IDs.

This feature enables F2 series boards (such as


F2LQM2, F2LQM, F2LDGF2, and F2LSX) that
support multiple IDs to be used as F1 series boards
(such as F1LQM2, F1LQM, F1LDGF2, and F1LSX) so
that the NE software can manage the F2 series boards
in the same way as that for managing F1 series boards
at the same time, thereby improving the management
efficiency of the NE software.

Modified Features
No.

Description

Purpose

001

Inter-subrack wavelength
protection is categorized into
client 1+1 protection.

Client 1+1 protection and inter-subrack


wavelength protection are categorized into the
same group to optimize protection configuration.

Deleted Features
None

3.4.2 Hardware Updates


New Hardware
Name

Description

TNF1LDX

The TNF1LDX board is a dual-channel 10 Gbit/s wavelength conversion


board.

TNF2LSX

The TNF2LSX board is a single-channel 10 Gbit/s wavelength conversion


board.

TNF2LQM

The TNF2LQM board is a 4 x multi-rate ports wavelength conversion


board. It maps four channels of client services at Any rates into one OTU1
signal.

TNF2LQM2

The TNF2LQM2 board is a double 4 x multi-rate ports wavelength


conversion board. It maps double four channels of client services at Any
rates into two channels of OTU1 signals or maps the eight channels of
services At Any rates into one channel of OTU1 signals.

TNF2LDGF2

The TNF2LDGF2 board is a double 2 x GE wavelength conversion board.

TNF1OBU

The TNF1OBU board amplifies 40 wavelength signals in the C band.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

19

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Modified Hardware
None

Removed Hardware
None

3.4.3 Alarm Updates


New Alarms
Alarm Name

Description

OPUFLEX_PLM

OPU payload mismatch in ODUflex services

ODUFLEX_PM_TIM

ODUflex PM trace identifier mismatch

ODUFLEX_PM_DEG

ODUflex PM signal degrading

ODUFLEX_PM_BDI

ODUflex PM backward defect indication

ODUFLEX_PM_LCK

ODUflex PM signal locked

ODUFLEX_PM_OCI

ODUflex PM open connection indication

ODUFLEX_PM_AIS

ODUflex PM alarm indication signal

ODUFLEX_LOFLOM

Loss of frames or multiframes in ODUflex services

ETHOAM_SELF_LOOP

Point-to-point OAM port loopback

ETHOAM_VCG_SELF_LOOP

Point-to-point OAM VCTRUNK loopback

ETHOAM_RMT_LOOP

Point-to-point Ethernet OAM remote loopback

ETHOAM_RMT_SD

Point-to-point Ethernet OAM remote signal degrade

ETHOAM_DISCOVER_FAIL

Point-to-point Ethernet OAM discovery failure

ETHOAM_RMT_CRIT_FAULT

Point-to-point Ethernet OAM remote critical fault

LPT_ACTIVE

LPT switching indication

SHELF_AREA_POWER_OVER

Subrack section power high

VLAN_SNCP_PS

VLAN-SNCP protection switching indication

ODU_SNCP_STA_INDI

ODU SNCP protection switching indication

Modified Alarms
None

Deleted Alarms
None
Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

20

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.4.4 Performance Event Updates


New Performance Events
Performance Event
Name

Description

ODUFLEX_PM_BBE

PM section background block errors in ODUflex services

ODUFLEX_PM_ES

PM section errored seconds in ODUflex services

ODUFLEX_PM_SES

PM section severely errored seconds in ODUflex services

ODUFLEX_PM_UAS

PM section unavailable seconds in ODUflex services

ODUFLEX_PM_SESR

PM section severely errored second ratio for ODUflex


services

ODUFLEX_PM_BBER

PM section background block error ratio for ODUflex


services

ODUFLEX_PM_FEBBE

PM section far-end background block errors in ODUflex


services

ODUFLEX_PM_FEES

PM section far-end errored seconds in ODUflex services

ODUFLEX_PM_FESES

PM section far-end severely errored seconds in ODUflex


services

ODUFLEX_PM_FEUAS

PM section far-end unavailable seconds in ODUflex


services

ODUFLEX_PM_FESESR

PM section far-end severely errored second ratio for


ODUflex services

ODUFLEX_PM_FEBBER

PM section far-end background block error ratio for


ODUflex services

Modified Performance Events


None

Deleted Performance Events


None

3.5 V100R003C00SPC200
This section describes the updates in V100R003C00SPC200 compared with
V100R003C00SPC100.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

21

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.5.1 Feature Updates


New Features
None

Modified Features
No.

Description

Reason

Impact

Information about the ELOM board is


changed, including:

"1*AP8
ODU0&ODU1
mode" and "ODU0
mode" have some
same application
scenarios.

None

The "ODU0 mode" is deleted.

"ODU1CONV" is changed to "1*AP8


ODU1 mode", "ODU1UNCONV" is
changed to "1*AP4 ODU1 mode", and
"8ANYODU0_ODU1" is changed to
"1*AP8 ODU0&ODU1 mode."

Deleted Features
None

3.5.2 Hardware Updates


New Hardware
Name

Description

TNF1X40

The board multiplexes and demultiplexes 40 channels of optical signals in a


two-fiber bidirectional system or 16 channels of optical signals in a singlefiber bidirectional system.

Modified Hardware
None

Removed Hardware
None

3.5.3 Alarm Updates


New Alarms
None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

22

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Modified Alarms
None

Deleted Alarms
None

3.5.4 Performance Event Updates


New Performance Events
None

Modified Performance Events


None

Deleted Performance Events


None

3.6 OptiX OSN 1800 V100R003C00SPC100


This section describes the updates in V100R003C00SPC100 compared with V100R003C00.

3.6.1 Feature Updates


New Features
No
.

Description

Purpose

001

Ethernet Layer 2
switching features,
such as link
aggregation group
(LAG), multiple
spanning tree
protocol (MSTP),
internet group
management protocol
(IGMP), and
operation,
administration, and
maintenance (OAM)
1ag are supported.

LAG: Increasing link capacity, improving link availability

Issue 01 (2013-01-10)

MSTP: Prevents loops on a network and therefore a


broadcast storm; be used to back up links so that the
spanning tree topology can be recomputed and the backup
link can be used to restore network connections when the
working path is faulty; Be used to identify VLANs.
IGMP: Less network bandwidth; packets are forwarded
within the range of each VLAN. Therefore, the information
security is enhanced; quick response can be made to link
faults. As a result, the reliability is enhanced.
OAM: Detect hardware faults; detect and locate faults
automatically.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

23

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

No
.

Description

Purpose

002

Supports synchronous
Ethernet.

The synchronization status message (SSM) protocolcompliance physical clocks are supported. Clock
frequencies can be restored directly from physical optical
signals to ensure frequency synchronization between
upstream and downstream NEs, ensuring normal
transmission of services.

003

Supports EPLAN and


EVPLAN services.

Provides interworking LAN services for enterprise users.

004

Supports FPGA
updates on boards
without CPUs
through customized
package loading.

This feature helps resolve memory shortages that may


occur during an upgrade. With this feature, the system can
select the required board software based on the types of
physical boards installed on the NE.

Modified Features
None

Deleted Features
None

3.6.2 Hardware Updates


New Hardware
Name

Description

TNF2ELOM

Enhanced 8-port multi-rate wavelength conversion board

Modified Hardware
Name

Description

TNF1LEM18

Line wavelength conversion unit with 16 x Gigabit and 2 x 10


Gbit/s (18 x Gigabit) Ethernet switch

Removed Hardware
None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

24

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.6.3 Alarm Updates


New Alarms
Alarm Name

Description

EX_ETHOAM_CC_LOS

Loss of periodical continuity check packets

EX_ETHOAM_MPID_CNFLCT

Maintenance point conflict

LAG_PORT_FAIL

Port failure in a link aggregation group (LAG).

LAG_VC_PORT_FAIL

Virtual concatenation group (VCG) port failure in


an LAG

ETHOAM_SELF_LOOP

Point-to-point operation, administration, and


maintenance (OAM) port loopback

ETHOAM_VCG_SELF_LOOP

Point-to-point OAM VCTRUNK loopback

ETHOAM_RMT_LOOP

Point-to-point Ethernet OAM remote loopback

ETHOAM_RMT_SD

Point-to-point Ethernet OAM remote Ethernet


performance deterioration

ETHOAM_RMT_CRIT_FAULT

Point-to-point Ethernet OAM remote critical fault

ETHOAM_DISCOVER_FAIL

Point-to-point Ethernet OAM discovery failure

ETH_CFM_MISMERGE

Connections are incorrect

ETH_CFM_UNEXPERI

Errored frames are received

ETH_CFM_LOC

Loss of continuity

ETH_CFM_MACSTATUS

The MAC of the remote MEP malfunctions.

ETH_CFM_RDI

RDI indicator of the remote MEP

FLOW_OVER

Traffic received at the port exceeds the threshold.

COMMUN_FAIL

Inter-board communication failure

MAIL_ERR

Mail communication error

ODU1_LOFLOM

ODU1 PM loss of frame and multiframe

SYNC_F_M_SWITCH

SYNC force or manual switch

SYNC_LOCKOFF

Locked timing source in priority list

CLK_NO_TRACE_MODE

Clock entering into non-tracing running mode

SYN_BAD

Synchronous source degrading

WAVEDATA_MIS

Mismatch between the configured wavelength


(band) and the supported wavelength (band).

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

25

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Modified Alarms
None

Deleted Alarms
Alarm Name

Reason

ALM_DATA_RLOS

The alarm specification is modified.

ALM_DATA_TLOS

The alarm specification is modified.

3.6.4 Performance Event Updates


New Performance Events
Performance Event
Name

Description

HPFEUAS

Hp far end unavailable second

LPFEUAS

Lp far end unavailable second

Modified Performance Events


None

Deleted Performance Events


None

3.7 OptiX OSN 1800 V100R003C00


This section describes the updates in V100R003C00 compared with V100R002C00SPC200.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

26

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.7.1 Feature Updates


New Features
No.

Description

Purpose

001

Support for EPL


and EVPL services

In the case of EPL services, a bandwidth is exclusively


occupied by the service of a user and the services of
different users are isolated. In addition, the extra QoS
scheme and security scheme are not required.
In the case of EVPL services, services of different users
share the bandwidth. Therefore, the VLAN/QinQ scheme
needs to be used for differentiating services of different
users. If the services of different users need to be
configured with different quality levels, you need to adopt
the corresponding QoS scheme. EVPL services are
classified into two types, depending on whether the PORT
or VCTRUNK is shared.

002

Support for traffic


policing of
Ethernet data based
on quality of
service (QoS)

In a high bandwidth consuming network, quality of service


(QoS) can properly allocate limited bandwidth resources
by service type. In case of network congestion, QoS
preferentially guarantees committed bandwidth for
important services to ensure their availability.

003

Support for port


mirroring of
Ethernet data

To enable the LEM18 board to support port mirroring of


Ethernet data.

004

Support for
Ethernet ring
protection
switching (ERPS)
schemes

Ethernet ring protection switching (ERPS) prevents a


broadcast storm caused by data loops on an Ethernet ring
when the Ethernet ring is in normal state. Also, ERPS
quickly starts the ring protection link (RPL) when a link on
the Ethernet ring is broken to ensure proper
communication between the nodes on the Ethernet ring.

005

Support for the


open system
interconnection
(OSI) protocol

The NEs use unified DCCs to transmit the data of the OSI
protocol by using the OSI over DCC solution. In this way,
the U2000 can manage NEs. The OSI over DCC solution
applies to a network that is comprised of the OptiX
equipment and the third-party equipment that supports the
OSI over DCC function.

Modified Features
None

Deleted Features
None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

27

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.7.2 Hardware Updates


New Hardware
Name

Description

TNF1LEM18

An Ethernet board that converges 16 GE and 2 10GE services


into OTU2 service signals

Modified Hardware
None

Removed Hardware
None

3.7.3 Alarm Updates


New Alarms
Alarm Name

Description

BD_NOT_INSTALLED

No logical board is created for a physical board.

CLIENT_PORT_STA_INDI

Client-side 1+1 protection status indication.

INTRA_OTU_STA_INDI

OTU intra-board 1+1 protection status indication.

SW_SNCP_STA_INDI

SW SNCP protection status indication.

OLP_STA_INDI

Optical line protection status indication.

MULTI_RPL_OWNER

More than one RPL_OWNER node exists on a ring


network.

Modified Alarms
None

Deleted Alarms
Alarm Name

Reason

OPS_STA_INDI

The alarm specification is modified.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

28

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

3.7.4 Performance Event Updates


New Performance Events
Performance Event
Name

Description

E1_LCV_SDH

Count of E1 code violations

E1_LES_SDH

Count of E1 code violations in an errored second

E1_LSES_SDH

Count of E1 code violations in a severely errored second

E1_LLOSS_SDH

Count of E1 code violations in a signal loss second

T1_LCV_SDH

Count of T1 code violations

T1_LES_SDH

Count of T1 code violations in an errored second

T1_LSES_SDH

Count of T1 code violations in a severely errored second

T1_LLOSS_SDH

Count of T1 code violations in a signal loss second

Modified Performance Events


None

Deleted Performance Events


None

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

29

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Resolved Issues and Known


Issues

This chapter describes the issues resolved in each officially released version and the known
issues in the current version.

4.1 Resolved Issues


4.1.1 V100R003C01SPC300
This section describes the issues resolved in V100R003C01SPC300.
Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2012120604
414

Symptom and impact:

Minor

Root cause:

Sporadically, a BEFFEC_EXC alarm is


continually reported on the WDM-side
optical port of a TNF1LDX board when
the board undergoes a cold reset.

The board software is defective.


Solution:
The board software has been
modified.

Condition:
A TNF1LDX board undergoes a cold
reset.
DTS2012112100
358

Symptom and impact:

Minor

Though the trigger condition of ALS in the


forward direction is configured to
DISABLE, the configuration does not
take effect.
Condition:

Root cause:
The board software is defective.
Solution:
The board software has been
modified.

The trigger condition of ALS in the


forward direction is configured to
DISABLE, and the ALS function is
enabled.
Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

30

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2012112104
258

Symptom and impact:

Minor

Root cause:

On an in-service TNF1LEM18 board


equipped with an SFP electrical module,
services fail to restore after the SFP
electrical module is removed and reinserted.

After the SFP electrical module


is removed and re-inserted, it is
restored to the default
configuration. The board
software does not re-configure
the working rate and negotiation
mode of the SFP electrical
module.

Condition:
A TNF1LEM18 board is equipped with an
SFP electrical module. A user removes and
re-inserts the SFP electrical module.

Solution:
The board software has been
modified.

DTS2012112900
740

Symptom and impact:

Minor

When the manufacturer information of a


board is queried, the wavelength
information of the optical module is
incomplete and only the integral part of
the wavelength value is displayed. For
example, for an optical module whose
wavelength is 1560.61 nm, the wavelength
is displayed as 1560 nm.

The board software is defective


so that the fractional part of the
wavelength value is lost when
the board manufacturer
information is queried.
Solution:
The board software has been
modified so that the fractional
part of the wavelength value can
be displayed.

Condition:
A user queries the manufacturer
information of a board that has a colored
optical module.
DTS2012112104
230

Symptom and impact:

Root cause:

Minor

When a TNF2ELOM board is set to the


COMP mode and configured with crossconnections, a NEBD_XC_DIF alarm is
incorrectly reported.
Condition:
A TNF2ELOM board is set to the COMP
mode and configured with crossconnections.

Root cause:
When the NE software queries
the timeslot configuration of
cross-connections on the board,
the board incorrectly converts
the timeslot information and
sends the incorrect data to the
NE software. As a result, the
data is inconsistent between the
NE software and the board, and
a NEBD_XC_DIF alarm is
incorrectly reported.
Solution:
The board software has been
modified so that timeslot
information of crossconnections can be correctly
converted.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

31

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2012112104
578

Symptom and impact:

Minor

Root cause:

DTS2012112107
981

An NE houses an APIU board that is


equipped with power modules of both
versions A and B. When the power module
of version B has no external AC power
supply and the power module of version A
has normal external AC power supply, the
NE incorrectly reports an
EVT_CFG_DEAD_WORD_AUTOREP
event.

In hardware design, the power


module of version A is incapable
of detecting power-off events.
As a result, an
EVT_CFG_DEAD_WORD_AU
TOREP event is incorrectly
reported when the power
module of version B is powered
off.

Condition:

Solution:

Power modules of both versions A and B


are installed on an APIU board. The power
module of version B has no external AC
power supply, and the power module of
version A has normal external AC power
supply.

The board software has been


modified so that the
EVT_CFG_DEAD_WORD_AU
TOREP event is suppressed.

Symptom and impact:

Minor

A BD_STATUS alarm is incorrectly


reported sporadically when the SCC board
is being reset.

Root cause:
The board software is defective.
Solution:
The board software has been
modified.

Condition:
The physical board of a service board is
online and its logical board is properly
configured. The SCC board is reset.
DTS2012112104
914

Symptom and impact:

Minor

On a
TNF1LDGF/TNF1LDGF2/TNF1LQM2/T
NF1LQM board configured with intraboard 1+1 protection, when the fiber of
the working channel is removed within 5s
after the fiber of the protection channel is
re-inserted, the protection switching fails
and services keep interrupted.
Condition:
On a
TNF1LDGF/TNF1LDGF2/TNF1LQM2/T
NF1LQM board configured with intraboard 1+1 protection, the fiber of the
working channel is removed within 5s
after the fiber of the protection channel is
re-inserted.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

Root cause:
An OTUk_BDI alarm triggers
intra-board 1+1 protection
switching. When the fiber of the
working channel is removed
within 5s after the fiber of the
protection channel is re-inserted,
the peer board in the protection
group keeps inserting
OTUk_BDI alarms into both the
working and protection
channels. As a result, the
working and protection channels
remain in the SF state and
services fail to restore.
Solution:
The OTUk_BDI alarm is set to
an optional condition to trigger
intra-board 1+1 protection
switching. By default, this
trigger condition is suppressed.
32

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2012112100
293

Symptom and impact:

Minor

Root cause:

An ODUk_LOFLOM alarm on the lower


order channel is not suppressed by an
R_LOS alarm reported on the WDM side
of a TNF2LDGF2, TNF2LQM,
TNF2LQM2, TNF1ELQM, or
TNF2ELOM board.

The board software is defective.


Solution:
The board software has been
modified.

Condition:
Services on a TNF2LDGF2, TNF2LQM,
TNF2LQM2, TNF1ELQM, or
TNF2ELOM board are multiplexed from
lower order ODUk signals to higher order
ODUk signals. An R_LOS alarm is
reported on the WDM side of the board.
DTS2012112103
793

Symptom and impact:

Minor

Root cause:
The board software is defective.
Solution:
The board software has been
modified.

When an inloop is performed on the client


side of a TNF2LSX board, FEC bit errors
occur on the protection channel of an
interconnected downstream board.
Condition:
An inloop is performed on the client side
of board 1#, as shown in the previous
figure.
DTS2012112104
180

Symptom and impact:

Minor

If four or more FE RJ45 Copper modules


are installed on a board, the query for
board manufacturer information times out.
Condition:

Root cause:
The board software is defective.
Solution:
The board software has been
modified.

Four or more FE RJ45 Copper modules


are installed on a board.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

33

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2012112803
851

Symptom and impact:

Minor

Root cause:

An optical port on an NE is configured


with the ASON fiber function. After the
NE is upgraded from
V100R001C01SPC100 to
V100R002C00SPC100 or a later version,
if the ASON fiber function is reconfigured for this optical port and the
SCC board is reset, the NE software
cannot start properly.

The board software is defective.


Solution:
The board software has been
modified.

Condition:
An optical port on an NE is configured
with the ASON fiber function. After the
NE is upgraded from
V100R001C01SPC100 to
V100R002C00SPC100 or a later version,
the ASON fiber function is re-configured
for this optical port and the SCC board is
reset.
DTS2012092509
477

Symptom and impact:

Minor

The power consumption of OADM boards


cannot be queried.

The board software is defective.

Condition:

The board software has been


modified.

Solution:

A user queries the power consumption of


OADM boards.
DTS2012122707
867

Root cause:

Symptom and impact:

Minor

No LP_FEUAS, HP_FEUAS, or
MS_FEUAS performance event is
reported when a TNF1TSP board reports
an LP_REI/LP_RDI, HP_REI/HP_RDI, or
MS_REI/MS_RDI alarm.

Root cause:
The board software is defective.
Solution:
The board software has been
modified.

Condition:
A TNF1TSP board reports an
LP_REI/LP_RDI, HP_REI/HP_RDI, or
MS_REI/MS_RDI alarm.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

34

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

4.1.2 V100R003C01SPC200
This section describes the issues resolved in V100R003C01SPC200.
Trouble
Ticket
Number

Description

Severity

Solution

DTS2011120808
077

Symptom and impact:

Minor

Root cause:

After a user configures ODUk


cross-connections for the east and
west WDM-side ports on the
ELOM board that is enabled with
the ODUk ADM function, logical
ports 201208 are occupied and
should not be used by other crossconnections. The software,
however, does not have such
restriction. As a result, users can
still configure other services for the
occupied logical ports 201208.
The services, however, cannot be
deployed successfully but there is
no alarm to indicate this error.

Some pass-through crossconnections and other crossconnections may occupy the same
hardware resources of the ELOM
board.
Solution:
The software has been modified
so that different cross-connections
cannot occupy the same hardware
resources.

Condition:

N/A

The ELOM board is enabled with


the ODUk ADM function.

A user configures ODUk crossconnections for the east and


west WDM-side ports on the
board.

A user configures others services


for logical ports 201208.

Symptom and impact:

Minor

When the LQP board is


interconnected with the MA526X
series ONUs or some OLTs of the
latest mainstream versions, services
become unavailable.
Condition:
The LQP board is interconnected
with the MA526X series ONUs or
some OLTs of the latest mainstream
versions.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

Root cause:
The LQP board does not have the
auto-sensing function for frame
header identification.
Solution:
The logic of LQP board has been
modified so that the board now
has the auto-sensing function for
frame header identification.

35

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severity

Solution

NA

Symptom and impact:

Minor

Root cause:

The APIU board sporadically


reports a false POWER_FAIL
alarm. When this occurs, the board
keeps functioning properly but the
I2C bus for the slot undergoes a
deadlock. Consequently, the I2C
bus cannot read the status or
information about the I2C
component in the slot.

Emerson power modules interfere


with the signal bus, resulting in a
deadlock of the I2C bus. In
addition, the I2C logic does not
provide sufficient error tolerance
and cannot release the I2C bus
from the deadlock state.
Solution:
The SCC logic has been modified
to enhance the error tolerance
capability of the I2C bus.

Condition:
The APIU board works for a long
time.

Upgrade the software version to


V100R003C01SPC200 or later to
resolve this issue.

4.1.3 V100R003C01SPC100
This section describes the issues resolved in V100R003C01SPC100.
Trouble
Ticket
Number

Description

Severity

Solution

DTS2011120703
680

Symptom and impact:

Minor

Root cause:

The F1LQM, F2LQM, F1LQM2, F2LQM2,


ELOM boards fail to correctly insert payload
type (PT) overheads when they transmit a
mixture of different services in convergence
mode. Due to this failure, the boards report an
OPU1_PLM alarm even though services on
the boards are normal.

The software of the


boards fails to insert PT
overheads in a standard
way when the boards
transmit a mixture of
different services.

Condition:

The board software has


been modified so that it
can insert PT overheads
in a standard way.

The F1LQM, F1LQM2, F2LQM2, F2LQM,


ELOM boards work in convergence mode to
transmit a mixture of different services.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

Solution:

36

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

4.1.4 V100R003C01
This section describes the issues resolved in V100R003C01.
Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2011091
900173

Symptom and impact:

Minor

Root cause:

When an OTU board uses an


exterior calibration optical
module on its WDM side, the
detected optical power of the
optical module is inaccurate.

The board software has a


bug in calculating the
input optical power of an
exterior calibration
optical module on its
WDM side. As a result,
the detected input optical
power differs greatly
from the actual input
optical power.

Condition:

DTS2011091
506411

The OTU board uses an


exterior calibration optical
module on its WDM side.

Users query the optical power


of the optical module.

Symptom and impact:

Solution:
The board software has
been modified to fix the
bug.
Minor

LPT is enabled for two


interconnected ELOM boards
and the client-side service type
is set to FE for the two boards.
When an R_LOS or LINK_ERR
alarm occurs on the client side
of the upstream ELOM board,
the tester that is connected to the
client side of the downstream
ELOM board fails to detect the
link down event. This issue
occurs sporadically.
Condition:

Two ELOM boards are


interconnected.

LPT is enabled for the ELOM


boards.

An R_LOS or LINK_ERR
alarm is generated on the
client side of the upstream
ELOM board.

Root cause:
The service chip
configuration in the
ELOM board software is
incorrect. When the
client-side service type is
FE and LPT is enabled
for the ELOM boards, the
boards sometimes fail to
insert code streams in
case of an R_LOS or
LINK_ERR alarm on
client side of the
upstream board.
Solution:
The board software for
the ELOM boards has
been modified.

4.1.5 V100R003C00SPC200
This section describes the issues resolved in V100R003C00SPC200.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

37

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

4.1.6 V100R003C00SPC100
This section describes the issues resolved in V100R003C00SPC100.
Trouble
Ticket
Number

Description

Severi
ty

Solution

DTS2010102
000735

Symptom and impact:

Minor

Root cause:

ERPS protection is
configured for the
LEM18 board. Trigger a
protection switching by
changing the optical port
status from enabled to
disabled. The switching
time is about 700 ms,
which exceeds the
specified time.
Condition:
ERPS protection is
configured. Trigger a
protection switching by
changing the optical port
status from enabled to
disabled.

When a port is enabled or disabled,


the NE software takes a long time
to delete the learned MAC address
of the east or west port and send a
protection switching notification.
As a result, the protection
switching time exceeds the
specified value.
Solution:
The NE software has been
modified so that it sends a
protection switching notification
prior to deleting the learned MAC
address when a port is enabled or
disabled. This ensures the protocol
components can promptly respond
to a protection switching action.

4.1.7 V100R003C00
No issues are resolved in V100R003C00.

4.2 Known Issues


This section describes the known issues in V100R003C01SPC300.
Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2013010504
456

Symptom and impact:

Minor

Preventive
measure:

10GE LAN services are connected to the client side of the


TNF1LDX or TNF2LSX board in bit transparent
transmission mode. In case of a client-side fiber cut, the
downstream board connected to the WDM side of the
TNF1LDX or TNF2LSX board sometimes reports transient
OTU2_LOF alarms.
Condition:
10GE LAN services are connected to the client side of the
TNF1LDX or TNF2LSX board in bit transparent

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

None.
Workaround:
Connect 10GE
LAN services
in MAC
encapsulation
mode.

38

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Trouble
Ticket
Number

Description

7 Related Documents

Severit
y

Solution

Minor

Preventive
measure:

transmission mode and a fiber cut occurs on the client side.


DTS2012081507
013

Symptom and impact:


When a TNF1LDX, TNF2LSX, TNF2ELOM, or TNF1LSX
board is receiving/transmitting 10GE LAN services (in
MAC encapsulation mode), packet loss occurs sporadically
if the services are composed of 64-byte packets and 9600byte packets, which account for 90% and 10% of the
services respectively.

None.
Workaround:
Transmit 10GE
LAN services
in bit
transparent
transmission
mode.

Condition:
A TNF1LDX, TNF2LSX, TNF2ELOM, or TNF1LSX
board receives/transmits 10GE LAN services (in MAC
encapsulation mode). The services are composed of 64-byte
packets and 9600-byte packets, which account for 90% and
10% of the services respectively.
DTS2012052408
976

Symptom and impact:

Minor

After an NE is powered on or the SCC board is cold reset,


an SWDL_CHGMNG_NOMATCH is incorrectly reported
sporadically. However, services are not interrupted.

None.
Workaround:

Condition:

Warm reset the


SCC board.

An NE is powered on or the SCC board is cold reset.


DTS2010121101
474

Symptom and impact:

Preventive
measure:

Minor

Two TNF1LSX boards on two NEs are interconnected on


their WDM sides. After one of the two NEs is upgraded
from V100R001C02 to V100R002C00SPC200 or a later
version, the TNF1LSX board on the other NE reports
transient SM_BDI and PM_BDI alarms on its WDM side.
However, services and communication are not affected.

Preventive
measure:
Do not monitor
the SM_BDI
and PM_BDI
alarms before
the upgrade.
Workaround:
None.

Condition:
Two TNF1LSX boards on two NEs are interconnected on
their WDM sides and one of the two NEs is upgraded from
V100R001C02 to V100R002C00SPC200 or a later version.
DTS2011112102
444

Symptom and impact:


After an NE is downgraded from V100R003C01 or a later
version to V100R003C00SPC200, communication channels
on the ELOM board installed on the NE are lost and the NE
becomes unreachable.
Condition:
An NE configured with the ELOM board is downgraded
from V100R003C01 or a later version to

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

Major

Preventive
measure:
Switch to the
standby
communication
channel before
a downgrade.
Workaround:
39

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Trouble
Ticket
Number

Description

7 Related Documents

Severit
y

V100R003C00SPC200.
DTS2011091405
413

Symptom and impact:

None.
Minor

Two F2LQM2, ELOM, F2LQM, F2LDGF2, F1ELQM or


F2LSX boards are interconnected on the WDM sides. After
independent DCN is enabled for one of them and disabled
for the other board, the ESC communication between the
two boards is interrupted.

Workaround:
Ensure that the
independent
DCN is enabled
or disabled for
both of the two
connected
boards.

Two F2LQM2, ELOM, F2LQM, F2LDGF2, F1ELQM or


F2LSX boards are interconnected on the WDM sides.

Symptom and impact:

Preventive
measure:
None.

Condition:

DTS2011041802
282

Solution

Warning

Cross-connection configurations on the ELOM board and


on the NE may be inconsistent in the following scenarios:

Preventive
measure:

Do not
perform a
cold reset on
the SCC
board before
configuratio
ns are saved
to the NE
database.

Do not delete
crossconnections
on the
ELOM
board when
the board is
in the warm
reset
process.

After cross-connections are configured on the ELOM


board, a cold reset is performed on the SCC board before
the cross-connection configuration is saved to the NE
database.
Cross-connections on the ELOM board are deleted during
the warm reset process of the board.
Condition:

After cross-connections are configured on the ELOM


board, a cold reset is performed on the SCC board
before the cross-connection configuration is saved to the
NE database.

Cross-connections on the ELOM board are deleted during


the warm reset process of the board.

Workaround:
None.
DTS2010092100
310

Symptom and impact:


No IIC chip is provided for a module with BOM code
34060287 (optical transceiver, SFP, 1310 nm, STM1, 19 to
14 dBm, 30 dBm, LC, MM, 2 km). Therefore, alarms,
performance events, and thresholds related to the laser on
the module, or the module manufacturer information cannot
be queried. In addition, a LASER_MOD_ERR_EX alarm is
reported when the module is online.

Minor

Preventive
measure:
None.
Workaround:
None.

Condition:
A module with BOM code 34060287 is used. The module is
Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

40

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Trouble
Ticket
Number

Description

7 Related Documents

Severit
y

Solution

Minor

Preventive
measure:

used in few network scenarios.


OPHD31591

Symptom and impact:


SFP optical modules are used on the WDM side of the
TNF1LWX2 board. When the board is connected to an
optical source without input signals, the SFP optical
modules behave differently. Some modules report the
R_LOC alarm, whereas other modules report the R_LOS
alarm.

None.
Workaround:
None.

This issue occurs because SFP optical modules from


different vendors have different R_LOS detection
mechanisms. Some modules detect the R_LOS alarm based
on the loss-signal mode, whereas other modules are based
on the loss-power mode. As a result, the SFP optical
modules behave differently.
Condition:
SFP optical modules are used on the WDM side of the
TNF1LWX2 board and the board is connected to an optical
source without input signals.
OPHD29274

Symptom and impact:

Minor

The jitter transfer function of the TNF1LWX2 board fails to


meet the specification requirement.

OPHD33667

Preventive
measure:
None.

Condition:

Workaround:

This problem inevitably recurs.

None.

Symptom and impact:


The LSX board transiently reports the OTU_LOF alarm or
the BEFEC_EXC, ODU2_PM_OCI, ODU2_PM_AIS, and
ODU2_PM_LCK alarms on the WDM side. The alarms do
not interrupt services or communication.
Condition:

Minor

Preventive
measure:
None.
Workaround:
None.

The WDM sides of two LSX boards are connected. In nonregeneration mode, a WDM-side inloop or outloop is
performed on the upstream LSX board A and then released.
The downstream LSX board B reports transient alarms.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

41

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

OPHD30423

Symptom and impact:

Minor

Preventive
measure:

When the LQM2 board works in regeneration mode, there


are no indicators to reflect the optical power status of the
RX1/TX1 and RX5/TX5 ports.

Power high and


low alarms are
added so that
users can
determine the
status of port
optical power.

Condition:
The LQM2 board (in 2LQM mode) is set to regenerating
mode.

Workaround:
None.
OPHD31809

Symptom and impact:

Minor

The OADM board does not report optical-layer alarms. If


you disconnect the fiber at the input terminal of the OADM
board when the NMS performs end-to-end management, the
downstream OTU board detects an R_LOS alarm. As a
result, the link status displayed on the NMS is incorrect.

Preventive
measure:
None.
Workaround:
None.

Condition:
This problem inevitably recurs.
OPHD35488

Symptom and impact:

Minor

When the LQG board adopts the GFP_F encapsulation


technology, the RMON performance statistics do not
include packets that are 1 byte larger than the maximum
packet length.

Preventive
measure:
None.
Workaround:
None.

Condition:
The RMON packet length on the test instrument is 1 byte
larger than the maximum packet length.
OPHD29906

Symptom and impact:


Two LOE boards are interconnected to perform a PRBS
test. The test is initiated by LOE board A and a fiber
loopback is configured on the client side of LOE board B.
In this case, a few incorrect bytes and fragmented packets
occur in the RMON statistics. In addition, the number of
transmitted packets and the number of received packets for
some of the two types of boards are sometimes inconsistent
in the RMON statistics.

Minor

Preventive
measure:
None.
Workaround:
None.

Condition:
Two LOE boards are interconnected and a PRBS test is
performed in the upstream direction.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

42

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

OPHD38866

Symptom and impact:

Minor

Preventive
measure:

When an SM_TIM alarm is generated on the WDM side of


an OTU board and the TIM follow-up response in the SM
section is enabled, no count of ODU UAS performance
events is present on the WDM side of the board.

None.
Workaround:
None.

Condition:
An SM_TIM alarm is generated on the WDM side of the
OTU board and the TIM follow-up response in the SM
section is enabled.
OPHD38949

Symptom and impact:

Minor

In SDH OTU2 mapping mode, GE services encapsulated


in GFP-F mode are configured on the client side of the LOE
board. When an inloop is set on the WDM side of the
board, the client-side optical port reports an
ALM_DATA_TLOS alarm and the RMON statistics on the
client side are incorrect.

Preventive
measure:
None.
Workaround:
None.

Condition:
In SDH OTU2 mapping mode, the GFP-F encapsulation
mode is configured on the client side of the LOE board. In
this case, an inloop is set on the WDM side of the board.
OPHD38680

Symptom and impact:

Minor

Two LQP boards are interconnected on the WDM sides.


When an OTU_AIS or a LOS alarm is generated on one of
the LQP boards, sometimes the count of otu2biaes
performance events is present in the performance statistics
from the opposite board.

Preventive
measure:
None.
Workaround:
None.

Condition:
Two LQP boards are interconnected through the WDM
sides and an OTU_AIS or a LOS alarm is generated on the
WDM side of one of the LQP boards.
DTS2010101302
858

Symptom and impact:


A cold reset is performed on a non-RPL owner node when
ERPS protection is configured for the LEM18 board. The
service restoration time on the node is the sum of the board
cold reset time and the time specified by WTR timer.
Condition:

Minor

Preventive
measure:
None.
Workaround:
None.

Perform a cold reset on a non-RPL owner node configured


with ERPS protection.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

43

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2010121003
080

Symptom and impact:

Minor

Preventive
measure:

P<->P+S services are configured between IP and TRUNK


ports on the LEM18 board. Values of RMON statistical
items related to packets in the size range of 1024 bytes and
packets exceeding thresholds are inaccurate in some
scenarios.

None.
Workaround:
None.

Condition:
P<->P+S services are configured between IP and TRUNK
ports.
DTS2010122700
042

Symptom and impact:

Minor

A service under ERPS protection is dually fed over QinQ


links. After the protection QinQ link is deleted, the service
over the working QinQ link is interrupted for approximately
1 ms.

Preventive
measure:
None.
Workaround:
None.

Condition:
A service under ERPS protection is dually fed over QinQ
links.
The standby QinQ link is deleted.
DTS2011031103
948

Symptom and impact:


When the following boards are interconnected, a user
configures a fiber loopback on the client side of one of the
two boards and connects the client side of the other board to
a device or test meter:

TNF1ELQM

TNF1LQM

TNF1LQM2

TNF2ELOM

TNF2LQM

TNF2LQM2

Then the user configures an FE service, and removes and


reinserts the receive fiber on the client side. A LINK_ERR
alarm is reported and cannot be cleared.
Condition:

Any two of the above-mentioned boards are


interconnected.

A user configures an FE service.

The user removes and reinserts the receive fiber on the


client side.

A LINK_ERR alarm is reported.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

Minor

Preventive
measure:
None.
Workaround:
If the other
board is
connected to a
test meter on its
client side,
force the test
meter to send
packets. If the
other board is
connected to a
router, perform
a ping
operation on
the router. Then
the LINK_ERR
alarm is
cleared.

44

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Trouble
Ticket
Number

Description

Severit
y

Solution

DTS2012042401
494

Symptom and impact:

Warning

Preventive
measure:

Two ELOM boards are interconnected. After configuring an


ODUflex service, a user disconnects a client-side receive
port on one of the ELOM boards. Then the downstream
board reports a transient ODUFLEX_LOFLOM or
ODUFLEX_PM_AIS alarm.

None.
Workaround:
None.

Condition:
Two ELOM boards are interconnected.
A user configures an ODUflex service and disconnects a
client-side receive port on one of the ELOM boards.
DTS2012062504
449

Symptom and impact:


When a MAC or PHY inloop is configured at the client-side
port TX18/RX18 on the LEM18 board, false loopback
alarms are reported for WDM-side optical ports 1 and 2 on
the LEM18 board.
Condition:

Warning

Preventive
measure:
None.
Workaround:
None.

A MAC or PHY inloop is configured at the client-side port


TX18/RX18 on the LEM18 board.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

45

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Important Notes

5.1 Hardware

Wear an ESD wrist strap or a pair of ESD gloves when handling boards. Make sure that
the ESD wrist strap is properly grounded so that the board is not damaged by static
discharge.

Read through the related manuals before you install, operate, or maintain the OptiX OSN
1800 to prevent personal injuries caused by laser radiation.

Wear proper eye-protection when performing operations on fibers or lasers.

Ensure that the optical source is switched off before disconnecting optical fiber
connectors.

If an optical port is being used, cover it and the optical connector by using two separate
anti-dust caps after you disconnect the optical port from the fiber.

Do not look into an exposed fiber terminal or open connector if you are not sure that the
laser is shut down.

Use an optical power meter to verify that the optical source is switched off by measuring
the optical power.

Do not use an optical tool such as a microscope, magnifying glass, or eye glass to view
an optical connector or fiber that is transmitting optical signals.

Observe local safety regulations and only allow personnel certified to work with high
voltage and AC currents to install the AC power supply.

Do not wear electrically-conductive objects such as the watches, bracelets, earrings, and
necklaces during the operation.

If a subrack has water stains or is damp, shut down the power supply for the subrack
immediately.

If the environment in which the OptiX OSN 1800 operates is humid, ensure that the
OptiX OSN 1800 is completely dry.

Shut down the power before you install or remove power cables.

Note that the TSPA board needs to connect to a 75-ohm E1 port and the TSPB board
needs to connect to a 120-ohm E1 port or 100-ohm T1 port.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

46

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Upgrade Impact

Before upgrading the product from an earlier version to V100R003C01SPC300, read this
chapter carefully to understand the potential impact of the upgrade on the system.

6.1 Impact Checklist


No.

Item

Change
d

Change
Impact

Or Not

Impac
t
Level

Impact
Referenc
e

Changes to the alarm list

No

N/A

N/A

N/A

Changes to Nessus scanning report on Huawei


TX&FMSAN products and iManager U2000

No

N/A

N/A

N/A

Changes to Tx port list

No

N/A

N/A

N/A

Changes to product version mapping

Yes

Yes

Medium

For details,
see 1.2.1
IStep
11Table 1.1.

Changes to management northbound and


southbound interfaces

Changes to the power supply

No

N/A

N/A

N/A

Changes in the compliance with GS16

No

N/A

N/A

N/A

Changes to optical port specification and power


budget

No

N/A

N/A

N/A

Changes in the compliance with optical


EN60825 DoC and GS6 certification

No

N/A

N/A

N/A

Changes in the compliance with CE

No

N/A

N/A

N/A

Changes in the compliance with EN60950 DoC


for H&S

No

N/A

N/A

N/A

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

47

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

No.

Item

7 Related Documents

Change
d

Change
Impact

Or Not

Impac
t
Level

Impact
Referenc
e

10

Changes in the compliance with ETS 300 386


DoC and GS7 certification for EMC

No

N/A

N/A

N/A

11

Changes in the compliance with DoC for


acoustic emissions (ETS 300-753)

No

N/A

N/A

N/A

12

Changes in the compliance with DoC for


Environmental Conditions (ETS 300-019)

No

N/A

N/A

N/A

13

Change in processes to add or remove NEs

Change in processes to add or remove cards (all


card types required by design)

Change in processes to manual add or remove


circuits/trails (all card types required by design)

Change in processes to U2000 trail build


(search) and fiber connectivity

14

DCN management configuration

No

N/A

N/A

N/A

15

Network features (protection)

No

N/A

N/A

N/A

Network features (laser operation)

No

N/A

N/A

N/A

Test tools and diagnostics (power measurement)

No

N/A

N/A

N/A

Test tools and diagnostics (loop back)

No

N/A

N/A

N/A

17

Traffic performance monitoring

No

N/A

N/A

N/A

18

Changes to parameter configuration settings

No

N/A

N/A

N/A

16

6.2 Impact During Upgrade and Rollback


This section describes the impacts that may occur during the upgrade.

During the upgrade, ensure that the NE is in the normal state. After the FPGA of an
F1LQM, F1LDGF, F1LQM2, F1LDGF2, F1LDE, F1LOE, F1LQP, F1TSP, F1LWX2,
F1LQG, F1LSPL, F1LSPU, F1LSPR, F1LSX, or F1TSP is upgraded, the NE will
automatically perform a cold reset on the board. The cold reset takes less than 5 minutes.
During the cold reset, services on the board are interrupted.

During the activation of the new NE software, the NE is unreachable by the network
management system for less than 5 minutes.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

48

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

6.2.1 Impact of an Upgrade from


V100R003C01SPC200
Item

Affected
or Not

Description

Services

No

Services on the live network are not affected during the


upgrade.

Communicati
on

Yes

After the NE software is activated, the NE software is reset


and the software of the new version is started. The
communication between the U2000 and the NE is
interrupted for less than 5 minutes. During this period, the
U2000 cannot monitor the performance events and alarms
of the NE.
After the board software is activated, the board software is
reset and the software of the new version is started. The
communication between the U2000 and the board is
interrupted for less than 5 minutes. During this period, the
U2000 cannot monitor the performance events and alarms
of the board.

Alarms

Yes

SWDL_INPROCESS, BD_STATUS,
GNE_CONNECT_FAIL, PASSWORD_NEED_CHANGE,
LAN_LOC, NE_COMMU_BREAK, and
NE_NOT_LOGIN

6.2.2 Impact of an Upgrade from


V100R003C01SPC100
Item

Affecte
d or
Not

Description

Services

Yes

The FPGAs of the TNF1LQP boards are modified.


In the process of activating the board FPGA, services on the
boards are interrupted for less than 5 minutes.
The ERPS protection mechanism has been modified for the
TNF1LEM18 board. If ERPS protection is configured using the
LEM18 board on the NE, manually reset (cold) the LEM18
board after the software version is upgraded to
V100R003C01SPC200. During the upgrade, services on the
board are interrupted for less than 5 minutes.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

49

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Item

Affecte
d or
Not

Description

Communi
cation

Yes

After the NE software is activated, the NE software is reset and


the software of the new version is started. The communication
between the U2000 and the NE is interrupted for less than 5
minutes. During this period, the U2000 cannot monitor the
performance events and alarms of the NE.
After the board software is activated, the board software is reset
and the software of the new version is started. The
communication between the U2000 and the board is interrupted
for less than 5 minutes. During this period, the U2000 cannot
monitor the performance events and alarms of the board.

Alarms

Yes

The following alarms are generated during the downgrade:

BD_STATUS

GNE_CONNECT_FAIL

LAN_LOC

NE_COMMU_BREAK

NE_NOT_LOGIN

PASSWORD_NEED_CHANGE

SWDL_INPROCESS

6.2.3 Impact of an Upgrade from


V100R003C00SPC100
Item

Affected
or Not

Description

Services

Yes

The FPGAs of the TNF1LQP boards are modified.


In the process of activating the board FPGA, services on the
boards are interrupted for less than 5 minutes.
The ERPS protection mechanism has been modified for the
TNF1LEM18 board. If ERPS protection is configured using
the LEM18 board on the NE, manually reset (cold) the
LEM18 board after the software version is upgraded to
V100R003C01SPC200. During the upgrade, services on the
board are interrupted for less than 5 minutes.

Communi
cation

Yes

After the NE software is activated, the NE software is reset


and the software of the new version is started. The
communication between the U2000 and the NE is interrupted
for less than 5 minutes. During this period, the U2000 cannot
monitor the performance events and alarms of the NE.
After the board software is activated, the board software is
reset and the software of the new version is started. The
communication between the U2000 and the board is
interrupted for less than 5 minutes. During this period, the

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

50

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Item

Affected
or Not

7 Related Documents

Description
U2000 cannot monitor the performance events and alarms of
the board.

Alarms

Yes

The following alarms are generated during the downgrade:

BD_STATUS

GNE_CONNECT_FAIL

LAN_LOC

NE_COMMU_BREAK

NE_NOT_LOGIN

PASSWORD_NEED_CHANGE

SWDL_INPROCESS

6.2.4 Impact of an Upgrade from


V100R003C00SPC200
Item

Affected
or Not

Description

Services

Yes

The FPGAs of the TNF1LQP boards are modified.


In the process of activating the board FPGA, services on
the boards are interrupted for less than 5 minutes.
The ERPS protection mechanism has been modified for the
TNF1LEM18 board. If ERPS protection is configured
using the LEM18 board on the NE, manually reset (cold)
the LEM18 board after the software version is upgraded to
V100R003C01SPC200. During the upgrade, services on
the board are interrupted for less than 5 minutes.

Communicat
ion

Yes

After the NE software is activated, the NE software is reset


and the software of the new version is started. The
communication between the U2000 and the NE is
interrupted for less than 5 minutes. During this period, the
U2000 cannot monitor the performance events and alarms
of the NE.
After the board software is activated, the board software is
reset and the software of the new version is started. The
communication between the U2000 and the board is
interrupted for less than 5 minutes. During this period, the
U2000 cannot monitor the performance events and alarms
of the board.

Alarms

Issue 01 (2013-01-10)

Yes

The following alarms are generated during the downgrade:

BD_STATUS

GNE_CONNECT_FAIL

LAN_LOC

NE_COMMU_BREAK

NE_NOT_LOGIN

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

51

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

Item

Affected
or Not

7 Related Documents

Description

PASSWORD_NEED_CHANGE

SWDL_INPROCESS

6.2.5 Impact of an Upgrade from V100R003C00


Item

Affecte
d or
Not

Description

Services

Yes

The FPGAs of the TNF1LQP boards are modified.


In the process of activating the board FPGA, services on
the boards are interrupted for less than 5 minutes.
The ERPS protection mechanism has been modified for
the TNF1LEM18 board. If ERPS protection is configured
using the LEM18 board on the NE, manually reset (cold)
the LEM18 board after the software version is upgraded
to V100R003C01SPC200. During the upgrade, services
on the board are interrupted for less than 5 minutes.

Communication

Yes

After the NE software is activated, the NE software is


reset and the software of the new version is started. The
communication between the U2000 and the NE is
interrupted for less than 5 minutes. During this period, the
U2000 cannot monitor the performance events and alarms
of the NE.
After the board software is activated, the board software
is reset and the software of the new version is started. The
communication between the U2000 and the board is
interrupted for less than 5 minutes. During this period, the
U2000 cannot monitor the performance events and alarms
of the board.

Alarms

Issue 01 (2013-01-10)

Yes

The following alarms are generated during the


downgrade:

BD_STATUS

GNE_CONNECT_FAIL

LAN_LOC

NE_COMMU_BREAK

NE_NOT_LOGIN

PASSWORD_NEED_CHANGE

SWDL_INPROCESS

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

52

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

6.3 Impact on the System After the Upgrade


6.3.1 Impact on Equipment Maintenance
The upgrade has no impact on equipment maintenance.

6.3.2 Impact on Service Configuration


GE-SYNC is changed to GE-TTT-AGMP.
An interface for configuring the OSI protocol is added to enable ESC communication for
OTU boards.

6.3.3 Impact on Alarm and Performance Event


Reporting
A BD_NOT_INSTALLED alarm is reported if a physical board is installed but a logical board
is not created accordingly.
If an APIU board is installed, the POWER_FAIL alarm is changed to INPWR_FAIL and
OUTPWR_FAIL alarms. The display interface of the POWER_MODULE_OFFLINE alarm
has been optimized.

6.3.4 Impact on Security


The upgrade has no impact on security.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

53

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Related Documents

This chapter lists the related documents for the current product version and describes how to
obtain these documents.

7.1 V100R003C01SPC300 Documents


Table 1.1 lists V100R003C01SPC300 documents.
Table 1.1 List of V100R003C01SPC300 documents
BOM

Document

Description

Delivery

31185410

OptiX OSN 1800 Compact


Multi-Service Edge
Optical Transport Platform
Product Documentation(V100R003C01_04)

This CD-ROM provides


information about the
technology, networking and
application, installation,
commissioning,
configuration, maintenance,
and troubleshooting for the
OptiX OSN 1800.

The CD-ROM is
delivered with
equipment

7.2 Obtain Documents


7.2.1 Support Website
You can view or download related documentation from http://support.huawei.com.
You must apply for permission to obtain documentation from the website. If you are using
http://support.huawei.com for the first time, first register with the website.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

54

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

7 Related Documents

Registering with the Website


To register with http://support.huawei.com, perform the following steps:
Step 1 Access http://support.huawei.com.
Step 2 Click Register, and follow the instructions to complete the registration process.
If your registration is successful, you will be informed of your user name and password within
two or three working days.
----End

Viewing or Downloading Documentation


To view or download documentation from http://support.huawei.com, perform the following
steps:
Step 1 Access http://support.huawei.com.
Step 2 Click Log In. In the dialog box that is displayed, enter the user name, password, and
verification code and click Login.
Step 3 After a successful login, choose Optical Network > WDM > OSN 1800 in the Product
catalog pane.
The product documentation page is displayed.
Step 4 Click the view or download icon on the right of the documentation package name to view or
download the documentation.

You can also enter the product name in the Product Name text box on the home page of
http://support.huawei.com to search for documents specific to a product.

If the file name extension of a documentation package is .hdx, use HedEx Lite to view the
documents. You can obtain the software from Huawei customer service engineers.

----End

7.2.2 Hard Copies


All product documentation is available on a CD-ROM. Some other documents are delivered
as printed documents. Both the CD-ROM and printed documents are delivered with the
product.
The documents on the CD-ROM support the version of the delivered product. If you upgrade
a version (V) or release (R), contact Huawei local technical support center or local office for a
new CD-ROM. If you upgrade a customization (C) or build (B), or install a patch, see the
corresponding release notes for upgrade information.
To order a CD-ROM, submit an application to Huawei local technical support center or local
office. Provide the BOM number and name of the CD-ROM in the application.

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

55

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

A Acronyms and Abbreviations

Figure 1.1

Acronyms and
Abbreviations

A
AC

alternating current

ADM

add and drop multiplexer

B
BIOS

basic input/output system

BOM

bill of material

C
CPLD

complex programmable logic device

CWDM

coarse wavelength division multiplexing

D
DWDM

dense wavelength division multiplexing

E
EPON

Ethernet passive optical network

F
FE

fast Ethernet

FEC

forward error correction

FPGA

field programmable gate array

Issue 01 (2013-01-10)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

56

OptiX OSN 1800 Compact Multi-Service Edge Optical


Transport Platform
Release Notes

GE

Gigabit Ethernet

GPON

Gigabit passive optical network

A Acronyms and Abbreviations

N
NE

network element

O
OADM

optical add/drop multiplexer

OTU

optical transponder unit

OLT

optical line terminal

ONU

optical network unit

P
PRBS

pseudo-random binary sequence

S
SDH

synchronous digital hierarchy

SONET

synchronous optical network

STM

synchronous transport module

W
WDM

Issue 01 (2013-01-10)

wavelength division multiplexing

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co.,
Ltd.

57

Das könnte Ihnen auch gefallen