Standard Functionality
50BF
Circuit Breaker Fail
64H
High Impedance REF
74TC
Trip Circuit Supervision
81HBL2
Inrush Detector
81HBL5
Overfluxing Detector
87BD
Biased Differential (2Windings)
87HS
High-Set Differential
8 Settings Groups
Password Protection 2 levels
User Programmable Logic
Self Monitoring
Optional Functionality
24
27/59
37
46NPS
49
50
50G/N
51
51G/N
59N
81
Over-Fluxing
Under/Over Voltage
Undercurrent
Negative Phase Sequence Overcurrent
Thermal Overload
Instantaneous Overcurrent
Instantaneous Earth Fault
Time Delayed Overcurrent
Time Delayed Measured Earth Fault /SEF
Neutral Voltage Displacement
Under/Over Frequency
Data Communications
Front USB port
Rear RS485 port
User Interface
20 character x 4 line backlit LCD
Menu navigation keys
3 fixed LEDs
16 or 24 Programmable Tri-colour LEDs (Option)
Protocols
IEC60870-5-103 or Modbus RTU protocols User
selectable
Optional DNP 3.0
REYROLLE
7SR242_-2_A_1-0CA0
74
TCS
(x6)
W1-IL1 (IA)
37
(x2)
49
50
BF
50
(x2)
51
(x2)
81
HBL
2
81
HBL
5
W1-IL2 (IB)
37
(x2)
49
50
BF
50
(x2)
51
(x2)
81
HBL
2
81
HBL
5
W1-IL3 (IC)
37
(x2)
49
50
BF
50
(x2)
51
(x2)
81
HBL
2
81
HBL
5
46
NPS
(x4)
50N
(x2)
51N
(x2)
64H
50G
51G
(x2)
IG1
ICT
64H
50G
51G
(x2)
46
NPS
50N
51N
37
49
50
BF
50
51
81
HBL
2
81
HBL
5
37
49
50
BF
50
51
81
HBL
2
81
HBL
5
37
49
50
BF
50
51
81
HBL
2
81
HBL
5
24
(x3)
27
59
(x4)
59N
(x2)
81
(x6)
IG2
W2-IL3 (IC)
W2-IL2 (IB)
W2-IL1 (IA)
V1 (VX)
87BD
ICT
REYROLLE
Standard Functionality
Waveform recorder
Data Log
Fault Records
The last 10 fault records are displayed on the HMI, with
time and date of trip, measured quantities and type of
fault.
Optional Functionality
24 Over-Fluxing
Two elements each provide a definite time lag (DTL)
characteristic, the third element provides a user defined
characteristic. Operates if Volts/Hertz ratio is above
setting for duration of delay.
27/59 Under/Over Voltage
Each element has settings for pickup level, drop-off level
and Definite Time Lag (DTL) delays. Operates if voltage
exceeds setting for duration of delay. Can be applied in
load shedding schemes.
37 Undercurrent
Each element has settings for pickup level and Definite
Time Lag (DTL) delays. Operates if current falls below
setting for duration of delay.
46NPS Negative Phase Sequence Overcurrent
Two DTL and two inverse/DTL elements are provided.
NPS Current elements can be used to detect unbalances
on the system or remote earth faults when a delta-star
transformer is in circuit.
49 Thermal Overload
REYROLLE
Tri-colour LEDs
81 Under/Overfrequency
Each element has settings for pickup level, drop-off level
and Definite Time Lag (DTL) delays. Each element
operates if frequency exceeds setting for duration of
delay. Typically applied in load shedding schemes.
Reydisp Evolution
REYROLLE
Surge Immunity
Temperature
IEC 60255-22-5
IEC 60068-2-1/2
Type
Level
Operating Range
-10 C to +55 C
Storage range
-25 C to +70 C
Humidity
IEC 60068-2-3
Type
Level
Variation
Between all
terminals and
earth, or
between any
two
independent
circuits
10 %
Type
Level
Operational test
56 days at 40 C and 95 %
relative humidity
IEC 60255-22-6
Insulation
IEC 60255-5
Type
Level
Variation
0.15 to 80 MHz
10 V
5%
Type
Level
Emissions
IEC 60255-25
Between independent
circuits
Impulse Voltage
Type test
5 kV (peak) 1.2 / 50 s
Limits at 10 m, Quasipeak
30 to 230 MHz
40 dB(V)
47 dB(V)
IP Ratings
Type
Level
IP 51
IP 30
Type
Limits
Quasi-peak
79 dB(V)
73 dB(V)
Average
66 dB(V)
60 dB(V)
Mechanical
Level
Vibration (Sinusoidal)
Allowable
superimposed ac
component
12% of DC voltage
Allowable breaks/dips in
supply (collapse to
zero)
20ms
Type
Level
Variation
Vibration
response
0.5 gn
5%
Vibration
endurance
1.0 gn
5%
Level
Variation
Common (longitudinal)
2.5 kV
5%
Series (transverse)
mode
1.0 kV
5%
Level
Variation
Shock
response
5 gn, 11 ms
5%
15 gn, 11 ms
5%
Electrostatic Discharge
Shock
withstand
Bump test
10 gn, 16 ms
5%
Type
Level
Variation
Contact discharge
8.0 kV
5%
Radiated Immunity
Seismic
IEC 60255-21-3 Class I
Mechanical Classification
Level
Variation
10 V/m
5%
Type
Level
Durability
Fast Transients
IEC 60255-22-4 Class IV
Type
Level
Variation
4kV
5%
REYROLLE
E8 Case Dimensions
REYROLLE
2
4
6
8
10
12
14
7SR242
+ve
-ve
BO 7
BI 11
BO 8
BI 12
BO 9
BI 13
BO 10
18
20
-ve
9
11
+ve
Optional
I/O
PSU
CT
CT/VT
Data
Comms
(Optional)
13
+ve
15
BO 11
17
BO 12
19
+ve
27
28
27
28
27
28
27
28
Rear View
Arrangement of terminals and modules
21
BI 15
-ve
+ve
BO 13
23
BO 14
25
27
+ve
NOTES
BI =
BO =
BI 17
24
+ve
BI 16
22
+ve
BI 14
16
BI 10
Binary Input
Binary Output
+ve
BI 18
26
28
+ve
BI 19
-ve
D
1
22
24
28
+ve
BO 1
-ve
3
GND.
BO 2
2
4
6
8
10
12
+ve
BI 1
-ve
11
+ve
BO 3
13
BI 2
-ve
15
+ve
17
BO 4
BI 3
-ve
19
21
16
Screen
18
20
Term.
18
20
22
24
26
28
17
19
21
23
25
27
BO 5
23
RS485
14
25
BO 6
27
+ve
-ve
1A
W2-IL1 (IA)
BI 6
5A
8
1A
BI 8
W2-IL3 (IC)
BI 9
5A
11
12
1A
17
18
5A
W1-IL1 (IA)
IG2
4
5
9
10
2
3
BI 7
+ve
-ve
5
6
W2-IL2 (IB)
+ve
-ve
3
4
1A
+ve
-ve
5A
BI 5
+ve
-ve
BI 4
+ve
-ve
26
5A
19
20
1A
6
7
5A
W1-IL2 (IB)
27
V1 (VX)
28
1A
10
11
5A
W1-IL3 (IC)
12
13
1A
14
15
16
5A
IG1
REYROLLE
Variants
Order No.
DUOBIAS-M
Multifunctional 2 winding
transformer differential
protection
7 S R 2 4 2
|
|
|
|
|
|
|
|
Protection Product
Transformer
Relay Type
Differential (2 winding)
| |
| |
4 |
|
|
- 2
A 1
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
A
| |
B
| |
| |
| |
1 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
2
- 0
A 0
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
A |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
B |
| |
| |
| |
| |
| |
| |
| |
| |
REYROLLE
Product description
Variants
Order No.
DUOBIAS-M
(continued from previous page)
7 S R 2 4 2
Option C:
- 24
- 27/59
- 59N
- 81
- 37
- 46NPS
- 49
- 50
- 50G/50N
- 51
Additional Functionality
No Additional Functionality
- 2
1 - 0 C A 0
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1)
2)
Functions are per winding unless otherwise stated, REF models require external resistors and metrosil at extra cost, see page Error! Bookmark not defined.
3)
REYROLLE
Qualifications
Siemens Protection Devices Limited operates a quality system accredited to ISO9001.
CE Compliant to relevant EU Directives.
Siemens Protection Devices Limited
PO Box 8
North Farm Road
Hebburn
Tyne & Wear
NE31 1TZ
United Kingdom
Tel: +44 (0)191 401 5555
Fax: +44 (0)191 401 5575
PTD 24hr Customer Support
Tel: +49 180 524 7000
Fax: +49 180 524 2471
E-mail: support.energy@siemens.com
November 2008
Revision 16
10
REYROLLE