Beruflich Dokumente
Kultur Dokumente
EN
RE
G ING
VE R
TI TU
VA EA
NO F
IN TER
N
A FIL
F
I
E
L
Contact Information:
Product Features:
Parker Hannifin
Hydraulic Filter Division Europe
European Product
Information Centre
Freephone: 00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES,
FI, FR, IE, IT, PT, SE, SK, UK)
filtrationinfo@parker.com
www.parkerhfde.com
21
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
TTF Series
Tanktop Mounted Return Line Filters
MAX 500 I/min - 10 bar
Features & Benefits
Features
Advantages
Benefits
LEIF elements
In-to-Out filtration
Ensures that oil enters the tank under the oil level Significant reduction of oil foaming
Magnetic pre-filtration
Typical Applications
Waste management trucks
Mobile cranes
Power packs
Wheeled loaders
Drilling equipment
22
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
Specification
Operation pressure:
Max. 10 bar.
Assembly:
Tank top mounted.
Connections:
Threaded BSP ports.
Flanged ports on request.
Filter housing:
Aluminium head and cover.
Seal material:
Nitrile, fluoroelastomer, neoprene.
Operation temperature range:
Seal material Nitrile: -40 to +100C.
Seal material Fluoroelastomer: -20 to
+120C.
Bypass setting
Opening pressure 0.8 / 1.5 or 2 bar.
Other settings on request.
Degree of filtration:
Determined by multipass test according to
ISO 16889.
Flow fatigue characteristics:
Filter media is supported so that the
optimum fatigue life is achieved.
TTF
Filtration media:
Microglass III and Ecoglass III for LEIF elements.
Also available 10m cellulose and 40m stainless steel mesh.
Element collapse rating:
10 bar (ISO 2941)
Pressure indicator options:
Setting 0.7 or 1.2 bar.
Other settings on request.
Visual pressure gauge.
Electrical pressure switch.
Options:
Diffuser type P (straight pipe, no perforated plate area)
Diffuser type T (with closed diffuser end cap and with perforated plate
area, recommended when oil entry in reservoir is close to the reservoir
bottom or to ensure oil entry under the reservoir oil level)
Magnetic pack:
Standard. TTF400 and 500 are standard supplied without magnets
Filling port in cover: (optional)
Plugged.
Filter element:
LEIF element with reusable metal element sleeve.
Optional conventional style element with steel end caps.
The LEIF element is patented and safeguards the use of genuine parts.
Note:
LEIF element can be used with mineral and HEES type oils.
For other fluids consult Parker Filtration.
LEIF contributes to ISO 14001 quality standards.
3
4
5
6
7
9a
8
10
9b
11
12
No.
4
1
1
1
1
1
1
0-1
0-3
0-3
1
1
1
1
1
1
Description
Flange nut
Cover
Cover-seal
Top-spring
Insert
Insert-seal
Element
Indicator
Plug M10x1
Unit-ring
Housing
Gasket
Sleeve
Funnel/diffuser
O-ring
Bypass set
13
14
15
16
23
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
TTF Series
Tanktop Mounted Return Line Filters
MAX 500 I/min - 10 bar
TTF Lengths 2-5 Single port
2
3
4
5
TTF 1-60
TTF 1-90
TTF 1-120
TTF 1-150
Port option
h1
D D1 H1
H2 H3 b
R R1
R2
FP
28
73
90
93
68 60 63 10 4x9 G1/2
Dimensions in mm
6
7
8
9
10
TTF 2-170
TTF 2-230
TTF 2-300
TTF 2-400
TTF 2-500
Port option
h1
D D1 H1
H2 H3 b
R R1
R2
FP
36
92
Dimensions in mm
24
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
H2
H1
Port option A - B h
2
3
4
4A
5
4B
TTF 1-60
TTF 1-90
TTF 1-120
TTF 1-140
TTF 1-150
TTF 1-175
h1
D D1 H1
H2
R R1 R2
175 170
G1 - G1
30
74
88
91
225 220
90 83 87.5 12 4x11
285 280
325 320
376 370
Dimensions in mm
6
7
8
9**
10**
TTF 2-170
TTF 2-230
TTF 2-300
TTF 2-400
TTF 2-500
h1 D D1 H1
H2
H3 R R1
R2
FP
Dimensions in mm
25
FP
131 190
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
G1
TTF Series
Tanktop Mounted Return Line Filters
MAX 500 I/min - 10 bar
Pressure Drop Curves
The recommended level of the initial pressure drop for low pressure filters is max 0.5 bar.
If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows:
p = (p32 x viscosity of medium used) / 32cSt.
16
21
26
29
1.4
21.8
10Q
p (bar)
05Q
7.3
0.5
20Q
20
40
60
16
17.4
14.5
11.6
0.8
05Q
0.6
8.7
0.4
10Q 5.8
2.9
20Q
0
30
60
90
0
150
120
Flow (l/min)
Flow (l/min)
16
47
20.3
31
1.4
17.4
1.2
14.5
14.5
0.8
11.6
0.8
11.6
16
24
31
39
02Q
1.2
05Q
0.6
8.7
10Q
0.4
20Q
0.2
0
30
60
90
120
150
p (bar)
p (PSID)
47
20.3
0
1.4
p (bar)
39
20.3
02Q
0.2
0
100
80
31
24
p (PSID)
p (bar)
14.5
1.2
02Q
1.5
p (PSID)
02Q
0.6
05Q
17.4
8.7
5.8
0.4
5.8
2.9
0.2
10Q
2.9
20Q
0
180
Flow (l/min)
60
120
0
180
Flow (l/min)
26
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
p (PSID)
39
66
79
93
36.3
21.8
14.5
05Q
0.5
100
39
150
200
250
7.3
26
39
53
66
50
100
150
79
119
132
23.2
1.8
20.3
1.2
17.4
1.4
14.5
05Q
0.6
8.7
p (bar)
11.6
0.8
10Q 5.8
0.4
0.2
2.9
20Q
50
100
150
200
250
300
350
400
0
500
450
13
26
39
53
66
79
92
106
119
132
20.3
17.4
14.5
0.8
05Q 11.6
0.6
8.7
0.4
10Q 5.8
20Q
0.2
2.9
Flow (l/min)
145
26.1
23.2
02Q
1.2
p (PSID)
1.4
p (bar)
106
1.6
300
0.1
106
Flow (l/min)
02Q
250
0.4
200
119
14.5
13.1
05Q
11.6
10.2
8.7
7.3
10Q
5.8
4.4
2.9
20Q
1.5
0
350
400
450
92
0.5
79
0.6
Flow (l/min)
1.6
66
0.2
0
350
300
53
02Q
0.7
20Q
50
26
0.3
10Q
13
0.8
29
1.5
0.9
02Q
p (bar)
53
50
100
150
200
250
300
350
400
450
500
0
550
Flow (l/min)
26
39
53
66
79
92
119
132
145
02Q
1.4
p (bar)
106
159
23.2
20.3
1.2
17.4
14.5
11.6
0.8
05Q
0.6
8.7
10Q 5.8
0.4
20Q
0.2
0
p (PSID)
1.6
50
100
150
200
250
300
350
400
450
500
550
2.9
0
600
Flow (l/min)
27
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
p (PSID)
26
p (bar)
13
p (PSID)
0
2.5
p (PSID)
TTF Series
Tanktop Mounted Return Line Filters
MAX 500 I/min - 10 bar
Pressure Drop Curves (cont.)
TTF60 (Element length code 2)
Cellulose & stainless steel media
16
20
1.45
0.1
0.58
040W
0.02
30
45
60
0.29
0
90
75
1.16
0.87
0.06
040W
0.04
0.58
0.02
0.29
30
60
39
47
56
2.03
10C
p (bar)
0.12
1.74
0.1
1.45
0.08
1.16
0.06
0.87
040W
0.04
0.58
0.02
0.29
30
60
90
120
150
0
0.12
16
1.45
24
0.58
0.04
040W
0.29
0.02
0
30
60
120
31
39
47
56
1.74
0
0.14
040W
0.04
0.58
0.02
0.29
p (bar)
0.87
0.06
26
39
53
66
1.74
1.16
0.87
0.06
040W
60
90
120
150
180
Flow (l/min)
0.58
0.29
0.02
0
210
1.45
0.08
0.04
30
79
2.03
10C
0.1
p (PSID)
1.16
13
0.12
1.45
10C
0
150
0.08
p (bar)
90
Flow (l/min)
0.1
1.16
0.87
39
1.74
0.06
31
10C
Flow (l/min)
0
0.12
24
0.08
0
210
180
0.1
p (bar)
24
p (PSID)
16
0
120
90
Flow (l/min)
31
1.74
1.45
Flow (l/min)
0
0.14
24
0.08
p (bar)
0.87
0.04
15
16
0.1
p (PSID)
p (bar)
1.16
0.06
10C
10C
0.08
0
0.12
24
1.74
p (PSID)
50
100
150
200
250
0
300
Flow (l/min)
26
39
53
66
79
92
0.12
1.74
10C
0.1
p (bar)
106
2.03
1.45
1.16
0.08
0.06
0.87
0.04
040W 0.58
0.02
0.29
50
100
150
200
250
300
350
p (PSID)
0
0.14
p (PSID)
0
400
Flow (l/min)
28
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
p (PSID)
0
0.12
TTF Series
Tanktop Mounted Return Line Filters
MAX 500 I/min - 10 bar
Indicator Options
Indicator PS pressure switch
Protective cap
with dual cable duct
for 1, 7-2, 3mm diameter cable
74
1
Switch
75
58
1 = COM.
2 = N.C.
3 = N.O.
24 A/F
27 A/F
M10x1
G1/8 (BSP)
30.5
28
Specifications
Elec.rating
Thread connection
Elec.connection
Protection
Code
Specifications
42V / 4A
M10x1
AMP 6.3x0.8 terminals + protective cap
IP65 (with cap) terminals IP00
FMUS1EBMM10L (Switch)
Elec.rating
Thread connection
Elec.connection
Protection
Switch type
Code
42V / 2A
G1/8
AMP terminal 6.3x0.8
IP65 (terminal IP00)
NO or NC
FMUS2EBMG02L (NO switch)
FMUS3EBMG02L (NC switch)
Visual indicator
M10: code
G1/8: code
1.2 bar
FMUG1EBPM10L
FMUG2EBPG02L
Indicator Thread
M10
M10
M10
G1/8"
M10
G1/8"
G1/8"
G1/8"
G1/8"
G1/8"
Ordering Information
Standard products table
Part number
Supersedes
TTF310QLBP2EG121
TTF320QLBP2EG121
TTF510QLBP2EG161
TTF520QLBP2EG161
TTF610QLBP2EG203
TTF620QLBP2EG203
TTF810QLBP2EG243
TTF820QLBP2EG243
TTF1010QLBP2HG24A
TTF1010QLBP2HG24A
TTF90
TTF90
TTF125
TTF125
TTF170
TTF170
TTF300
TTF300
TTF500
TTF500
Length 3
Length 3
Length 5
Length 5
Length 6
Length 6
Length 8
Length 8
Length 10
Length 10
10
20
10
20
10
20
10
20
10
20
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Plugged
Bypass
settings
Ports
Included
options
Replacement
elements
Supersedes
G3/4
G3/4
G1
G1
G11/4
G11/4
G11/2
G11/2
G11/2
G11/2
None
None
None
None
Diffuser type T
Diffuser type T
Diffuser type T
Diffuser type T
Diffuser type T
Diffuser type T
937878Q
937877Q
937852Q
937875Q
937853Q
937874Q
937855Q
937872Q
937857Q
937870Q
TXWL3-10
TXWL3-20
TXWL3E-10
TXWL3E-20
TXWL4-10
TXWL4-20
TXWL5A-10
TXWL5A-20
TXWL5C-10
TXWL5C-20
Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.
29
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
TTF Series
Tanktop Mounted Return Line Filters
MAX 500 I/min - 10 bar
Ordering Information (cont.)
Product configurator
Configurator example of a TTF Series filter
Box 2
Box 3
Box 4
Box 1
TTF
9
05QL
V
Box 1
Box 2
Code
Box 5
S3
Box 6
H
Box 8
1
Box 3
Filter type
Housing
TTF 1-60
TTF 1-90
TTF 1-120
TTF 1-120
TTF 1-120
TTF 1-150
TTF 2-170
TTF 2-230
TTF 2-300
TTF 2-400
TTF 2-500
TTF
Box 7
L24
Degree of filtration
Code
2
3
4
4A
4B
5
6
7
8
9
10
Box 4
Element media
Cellulose
Nom. rating
10C
Disposable element
LEIF element
Glass fibre
Microglass III (for disposable elements)
Ecoglass III (for Leif elements)
02Q
02QL
05Q
05QL
10Q
10QL
Box 5
Box 6
Seal type
Seal material
Nitrile
Fluorelastomer
Neoprene
Indicator
Code
B
V
On request
20Q
20QL
Wire mesh
Abs. rating
040W
Bypass valve
Code
G1
G2
S1
S2
S3
S4
S5
On request
P2
on request
Bypass valve
0.8 bar
1.5 bar
2.0 bar for TTF series
Blocked bypass
Other bypass settings
Code
B
E
H
X
on request
Box 7
Box 8
Filter connection
Ports
ISO 228-G3/4" (BSP) (TTF length 2,3,4 and 5)
ISO 228-G1" (BSP) (TTF length 2,3,4 and 5)
ISO 228-G11/4" (BSP) (TTF length 6 and larger)
2xISO 228-G11/4" (BSP) (TTF length 6 and larger)
ISO 228-G11/2" (BSP) (TTF length 6 and larger)
2xISO 228-G11/2" (BSP) (TTF length 6 and larger)
11/2" SAE-3000 PSI (TTF length 6 and larger)
11/2" SAE-3000 PSI (2nd port) + G11/2" (TTF length 6 and larger)
G2" (TTF length 6 and larger)
G2" + G11/2" (TTF length 6 and larger)
Options
Code
G12
G16
G20
2G20
G24
2G24
On request
LD24
On request
GM32
Options
No diffuser required
Diffuser type T with perforated plate area
Diffuser type P without perforated plate area
Diffuser with integrated hose connection for TTF
lengths 2, 3 and 4
No magnets
Plugged filling port
Diffuser type T and no magnets
Diffuser type P and no magnets
Diffuser type T, no magnets, plugged filling port
Diffuser type P, no magnets, plugged filling port
Air tight diffuser type T
Air tight diffuser type P
Other combinations
50.0%
N/A
N/A
N/A
6
On request
5
8
A
B
C
D
G
H
on request
Degree of filtration
x(c)=2
Code
1
3
4
Media
code
02Q/02QL
05Q/05QL
10Q/10QL
20Q/20QL
30
123
123
123
123
Item
Item
Item
Item
is
is
is
is
standard
standard green option
semi standard
non standard
Note: Standard items are in stock, semi standard items are available within
four weeks
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
spare element
spare element
spare element
spare element
spare element
spare element
spare element
spare element
spare element
TXWL2-2
937823Q
TXWL3-2
937824Q
TXWL3D-2
937825Q
TXWL3E-2
937826Q
TXWL4-2
937827Q
TXWL5-2
937828Q
TXWL5A-2
937829Q
TXWL5B-2
937830Q
TXWL5C-2
937831Q
TXWL2-5
937880Q
TXWL3-5
937879Q
TXWL3D-5
937825Q
TXWL3E-5
937849Q
TXWL4-5
937848Q
TXWL5-5
937847Q
TXWL5A-5
937846Q
TXWL5B-5
937845Q
TXWL5C-5
937844Q
TXWL2-10
937881Q
TXWL3-10
937878Q
TXWL3D-10
937851Q
TXWL3E-10
937852Q
TXWL4-10
937853Q
TXWL5-10
937854Q
TXWL5A-10
937855Q
TXWL5B-10
937856Q
TXWL5C-10
937857Q
TXWL2-20
937882Q
TXWL3-20
937877Q
TXWL3D-20
937876Q
TXWL3E-20
937875Q
TXWL4-20
937874Q
TXWL5-20
937873Q
TXWL5A-20
937872Q
TXWL5B-20
937871Q
TXWL5C-20
937870Q
Supersedes Spare Element table (TXW & TXX replaced by 900000 number)
TTF60
Part number
TTF90
Part number
TTF120
Part number
TTF125
Part number
TTF170
Part number
TTF230
Part number
TTF300
Part number
spare element
spare element
spare element
spare element
spare element
spare element
spare element
TXX2-10-B
937721
TXX3-10-B
937722
TXX3D-10-B
937723
TXX3E-10-B
937724
TXX4-10-B
937725
TXX5-10-B
937726
TXX5A-10-B
937727
TXW2-2-B
937751Q
TXW3-2-B
937750Q
TXW3D-2-B
937749Q
TXW3E-2-B
937748Q
TXW4-2-B
937747Q
TXW5-2-B
937746Q
TXW5A-2-B
937745Q
TXW2-5-B
937754Q
TXW3-5-B
937755Q
TXW3D-5-B
937756Q
TXW3E-5-B
937757Q
TXW4-5-B
937758Q
TXW5-5-B
937759Q
TXW5A-5-B
937760Q
TXW2-10-B
937787Q
TXW3-10-B
937786Q
TXW3D-10-B
937785Q
TXW3E-10-B
937784Q
TXW4-10-B
937783Q
TXW5-10-B
937782Q
TXW5A-10-B
937781Q
TXW2-20-B
937790Q
TXW3-20-B
937791Q
TXW3D-20-B
937792Q
TXW3E-20-B
937793Q
TXW4-20-B
937794Q
TXW5-20-B
937795Q
TXW5A-20-B
937796Q
ST2-40-B
937820
ST3-40-B
937819
ST3D-40-B
937818
ST3E-40-B
937817
ST4-40-B
937816
ST5-40-B
937815
ST5A-40-B
937814
31
Parker Hannifin
Hydraulic Filter Division Europe