F/O
Clear Right?
Clear Right!
Turning Right
Rotation!
First indication of N1:
N1
Fuel Low Pressure light out
Oil Pressure rising
Oil Low Pressure light out
Confirm min. 60 psi
After stable N1 (min. 12%):
RIGHT CONDITION LEVER
LOW IDLE
Light up
ITT and N1 Monitor Max 1000C
____ Degrees
Note for tech log.
OFF
HIGH IDLE
R GEN
RESET, ON
R DC GEN
EXTINGUISHED
L & R GEN TIE OPEN
EXTINGUISHED
Check Positive Load on Load Meter
L & R AC BUS
L & R AC BUS
L & R AC BUS
L & R AC BUS
L INV freq
L INV volt
R INV freq
R INV volt
CHECK
ILLUMINATED
ON
EXTINGUISHED
380 420 Hz
110 120 V
380 420 Hz
110 120 V
R AC BUS
R AC BUS R AC BUS
Master Warning
Freq Indication
R AC BUS
OFF, XFR
ILLUM, then EXTING
CANCEL
RESTORED
ON
INVERT INDICATION
SELECT LEFT
L AC BUS
L AC BUS L AC BUS
MASTER WARNING
Freq Indication
L AC BUS
OFF, XFR
ILLUM, then EXTING
CANCEL
RESTORED
ON
Charge BATT until GEN load below 40% and ammeter shows
drop in charge from max.
Clear Left
Turning Left
LEFT IGNITION SWITCH
ON
Rotation
Fuel Low Pressure light out
N1
Oil Low Pressure light out
Confirm min. 60 psi
Oil Pressure Rising
After N1 stable (min 12% N1)
LEFT CONDITION LEVER
LOW IDLE
Light up
ITT and N1 Monitor Max 1000C
____ Degrees
Note for tech log.
OFF
L GEN
RESET, ON
L DC GEN
EXTINGUISHED
Load indicator on L DC GEN Load Meter
R GEN
R DC GEN
MASTER CAUTION WARNING
OFF
ILLUMINATED
CANCEL
VOLTAGES CHECK
BATT, L + R GEN, CTR BUS
TPL BUS
EXT PWR
27.5 29 V
26.5 28 V
0V
R GEN
RESET, ON
R DC GEN
EXTINGUISHED
Check positive load R DC GEN Load Meter
GEN TIE SWITCH
L & R GEN TIE OPEN
AMMETER
TPL BUS VOLTAGE
GEN TIE SWITCH
L & R GEN TIE OPEN
AMMETER
OPEN
ILLUMINATED
0V
26.5 28 V
NORM
EXTINGUISHED
INDICATING CHARGE
CENTRE BUS
SELECT
BUS SENSE SWITCH
TEST
L & R GEN TIE OPEN & BATT TIE OPEN ILLUMINATED
CTR BUS VOLTAGE
0V
BUS SENSE SWITH
RESET
L & R GEN TIE OPEN & BATT TIE OPEN EXTINGUISHED
CENTRE BUS VOLTAGE
RESTORED
LOAD METERS PARALLELED WITHIN 10%