Even in the most demanding industrial and resource industry applications,
Nexans FIREX-II TECK90 cables have proven to have a superior service and
maintenance record.
FIREX-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket
compounds to ensure maximum safety to personnel and equipment in the event
of fire.
Standards
National CSA C22.2 N 131
Applications
FIREX-II TECK90 Cables, originally developed for use in Canadian mines, are
flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.
They are
suitable for a wide range of applications, including ALL hazardous locations.
Industries such as pulp and paper, chemical, petroleum and other primary and
secondary manufacturing industries have used FIREX-II TECK90 Cables,
particularly in areas
where cables are subject to the risk of mechanical damage and chemical attack.
Commercial applications for FIREX-II TECK90 Cables include apartment
buildings and commercial complexes.
FIREX-II TECK90 Cables can be relocated easily because they are rugged and
flexible. They can be used in both dry and wet locations in open wiring, in
ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible
cableways, and for direct burial.
TECK90 Cables are also suitable for service entrance installations - above and
below ground.
Highlights
Nexans FIREX-II TECK90 Cables are:
Page 1 / 4
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Offshore Topside cables
Phone: +65 6317 0101
candy.teo@nexans.com
Characteristics
Construction characteristics
Conductor material
Copper
Usage characteristics
Maximum operating temperature
90 C
Page 2 / 4
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Offshore Topside cables
Phone: +65 6317 0101
candy.teo@nexans.com
Bonding
AWG
8
6
Insulation
Thickness
Inner
Jacket
Thickness
Nominal
Diameters
Inner
Jacket
Armour
Outer
Covering
Approximate
Net Cable Weight
Aluminum Armour
Approximate
Copper
Content
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
lb/kft
kg/km
kg/km
10
0.090
2.29
0.060
1.52
0.931
23.64
1.206
30.63
1.315
33.40
721
1073
281
0.090
2.29
0.080
2.03
1.051
26.69
1.326
33.68
1.435
36.45
872
1298
446
0.090
2.29
0.080
2.03
1.146
29.11
1.421
36.09
1.530
38.86
1155
1720
665
0.090
2.29
0.080
2.03
1.200
30.49
1.475
37.46
1.584
40.23
1322
1968
866
0.090
2.29
0.080
2.03
1.266
32.15
1.541
39.14
1.670
42.42
1503
2237
1057
0.090
2.29
0.080
2.03
1.335
33.91
1.610
40.89
1.739
44.17
1732
2578
1304
1/0
0.090
2.29
0.080
2.03
1.415
35.95
1.690
42.93
1.819
46.20
2013
2997
1609
2/0
0.090
2.29
0.080
2.03
1.500
38.10
1.775
45.09
1.904
48.36
2339
3481
1997
3/0
0.090
2.29
0.080
2.03
1.606
40.80
1.956
49.68
2.090
53.09
2929
4359
2558
4/0
0.090
2.29
0.080
2.03
1.724
43.79
2.074
52.68
2.208
56.08
3544
5274
3173
250
0.090
2.29
0.110
2.79
1.882
47.80
2.232
56.69
2.366
60.10
4032
6001
3716
300
0.090
2.29
0.110
2.79
1.990
50.55
2.340
59.44
2.474
62.84
4605
6852
4414
350
0.090
2.29
0.110
2.79
2.094
53.19
2.444
62.08
2.578
65.48
5242
7800
5171
400
0.090
2.29
0.110
2.79
2.188
55.56
2.538
64.47
2.672
67.87
5852
8709
5883
500
0.090
2.29
0.110
2.79
2.355
59.81
2.705
68.71
2.839
72.11
7053
10495
7278
Page 3 / 4
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Offshore Topside cables
Phone: +65 6317 0101
candy.teo@nexans.com
Power
Bonding
AWG or kcmil
AWG
60C
75C
90C
10
40
50
55
65
70
85
85
95
1/0
2/0
Fittings
Appleton
T&B
CMP
Products
Cooper
Crouse-Hinds
55
TMC100138
10469/ST100-469
TMC125A
TECK100-7
75
TMC125163
10470/ST125-470
TMC125A
TECK125-8
95
TMC125163
10470/ST125-550
TMC150A
TECK125-8
100
115
TMC125163
10550/ST125-550
TMC150A
TECK125-8
115
130
TMC125188
10471/ST125-471
TMC150A
TECK125-10
110
130
145
TMC125188
10471/ST150-472
TMC200SA
TECK125-10
125
150
170
TMC125188
10472/ST150-472
TMC200SA
TECK125-10
145
175
195
TMC150200
10472/ST150-472
TMC200SA
TECK150-11
3/0
165
200
225
TMC150220
10551/ST200-551
TMC200A
TECK150-12
4/0
195
230
260
TMC200238
10474/ST200-474
TMC250SA
TECK150-12
250
215
255
290
TMC200275
10475/ST200-475
TMC250SA
TECK200-15
300
240
285
320
TMC200275
10552/ST200-475
TMC250A
TECK200-15
350
260
310
350
TMC200275
10553/ST250-477
TMC250A
TECK200-16
400
280
335
380
TMC200275
10553/ST250-478
TMC300A
TECK200-16
500
320
380
430
TMC300A
10477/ST300-479
TMC300A
TECK300-19
Notes:
1) Where stated, nominal and approximate values are provided for information purposes only and are subject to
standard manufacturing tolerances.
2) Based on 2012 CEC Table 2, for not more than 3 current carrying conductors in a cable or raceway.
3) The maximum conductor temperature (used to determine the maximum conductor ampacity) shall be based
on the lowest temperature rating of the electrical equipment, any wire connector, or cable (2012 CEC Rule 4-006).
Selling information
Caution Notice
In case of fire, well maintained early warning smoke detectors will give an alarm long before non-metallic coverings become
combustible.
However, in spite of the widespread and long-standing use of PVC in residential and commercial buildings, all purchasers of
PVC insulated/ jacketed products should be aware of the following:
Non-metallic coverings of electrical cables can burn and may transmit fire when ignited.
Burning non-metallic coverings may emit acid gases which are toxic and may generate dense smoke.