Sie sind auf Seite 1von 24

Power sources

Power sources

Whether you need to run your parts once a day or


24 hours a day, Enerpac has the power source to
help you get the job done. Power sources range from
air operated pumps to fully customizable electric
motor driven units.

With a wide variety of accessories to choose from,


Enerpac power units are easily the most versatile and
reliable in the industry.

Technical support
Refer to the “Yellow Pages” of this
catalog for:
• Safety instructions
• Basic hydraulic information
• Advanced hydraulic technology
• FMS (Flexible Machining Systems)
technology
• Conversion charts and hydraulic
symbols

113 

74 © 2006
▼ series ▼ page

Turbo air-hydraulic pumps PA 76 - 77

Modular Electric Pumps 78 - 81

Electric Pumps with remote valve control ZW 78 - 81

Other power sources 82 - 87

Air hydraulic boosters AHB, B 82 - 83

Pressure intensifiers PID 84 - 85

www.enerpac.com © 2006 75
Turbo II air-hydraulic pumps Application & selection
Shown: PAMG-5402PB, PACG-3102PB, PATG-3102PB, PATG-5105PB
Quick and powerful hydraulic supply in an
economical air-powered unit
Swing cylinders
Work supports

• On-demand stall-restart operation maintains system


pressure, providing clamp security
• External adjustable pressure relief valve (behind sight glass)
• Internal pressure relief valve provides overload protection
Linear cylinders

• Reduced noise level to 75 dBA reduces operator fatique


• Operating air pressure: 1,7-8,6 bar – enables pump to start at
low air pressure
• Reinforced heavy-duty lightweight reservoir for applications
in tough environments
• 5 valve mounting options provide flexibility in setup and
01_007
Power sources

operation
• Composite air piston seal allows operation on completely dry
Turbo II air-hydraulic pumps generate the
air supply
hydraulic pressure you need, using the air pressure
you have available. The air saver piston reduces air
consumption and operating costs. Select the required operation
They are ideal for providing the power and speed
PATG series PACG series
desired in simple clamping circuits. Turbo II air-
• Momentary (air-inlet) treadle • Momentary or continuous
hydraulic pumps are best suited to medium and for operation of single acting air inlet treadle
cylinders
lower cycle applications. At only 75 dBA, these new • Remote valve is required to
• Provides advance, hold and operate single-acting
Turbo II series help to keep noise level to a retract functions cylinders
minimum. • Pressure gauge included

PASG series PAMG series


• Momentary or continuous • Momentary or continuous
air inlet treadle air inlet treadle
• Suitable for mounting any • Manual 4-way, 3-position,
single or double acting valve tandem center valve for
with a CETOP 03 mounting single or double acting
configuration operation

PARG series
Select the required output • Includes 4,5 m air pendant
for remote control of
3000 series single-acting cylinders
• Hydraulic-air ratio 45:1 (350 bar hydraulic pressure • Provides advance, hold
at 8 bar air pressure) and retract functions
• Hydraulic pressure range 85 - 350 bar (range of
35 - 85 bar available with diminished stall/restart
performance)
• Maximum hydraulic oil flow 3,0 l/min Output Oil Flow versus pressure
3000 series – Flow vs hydraulic pressure 5000 series – Flow vs hydraulic pressure
5000 series 3,00 2,00
7,0 bar 7,0 bar
• Hydraulic-air ratio 60:1 (350 bar hydraulic pressure 2,50 5,5 bar 5,5 bar
1,60
at only 5,5 bar air pressure) 4,0 bar 4,0 bar
Oil flow (l/min) ➔

Oil flow (l/min) ➔

2,00 Air pressure Air pressure


• Hydraulic pressure range 120 - 350 bar (range of 1,20
48 - 120 bar available with diminished stall/restart 1,50

performance) 0,80
1,00
• Maximum hydraulic oil flow 2,0 l/min 0,50 0,40

0 0
0 100 200 300 400 0 100 200 300 400
Hydraulic pressure (bar) ➔ Hydraulic pressure (bar) ➔

76 © 2006 www.enerpac.com
Dimensions & options PA series
PATG series P T Oil Flow: 2,0-3,0 l/min
1 3/8"NPTF 2 G1/4" 4 1/4"NPTF
Pressure: 85 - 350 bar

219
Air: 340 l/min

176
203
165

139

121
151
Reservoir: 2,4 - 5,0 litres

5 8 6
178 38 320 8
30 254 347 E Bombas hidroneumáticas
F Pompes hydro-pneumatiques
PACG series PACG series include pressure gauge G-2517L.
P T D Lufthydraulische pumpen
3/8"NPTF 1 2 G1/4"
1/4"NPTF 3 4 1/4"NPTF

244
203
176
165

180

160
146

121
Options

Power sources
8 6
5 178 38 G1/4" 8 Large reservoir models
30 254 320 Enerpac Turbo
air-hydraulic
PASG series A B pumps are also
M5x11 3/8"NPTF 1 G1/4" 2 CETOP03 4 1/4"NPTF
available with
large reservoir.
B

Valves
Usable oil capacity
203
165

176
36

180

161
148

121

A Hor. mounted: 3,7 litres


Vert. mounted: 2,9 litres
5 8 6
178 38 8
30 254 320

201

components
71

System
PAMG series AB 396
3/8"NPTF 1 2 G1/4" 4 1/4"NPTF
To order your Turbo II with a
275

B large reservoir, replace 2 in


the model number with 5.
203
176
165

160
36

148

121

Yellow pages
5 8 6
178 38 8
Gauges and
30 254 320
accessories
PARG series
3/8"NPTF 1 2 G1/4" 4 1/4"NPTF 7 1/4"NPTF P T 106 

Regulator-
filter-lubricator
208
203
176
165

139

121

97 
8

8 6
5 30
178
254
38
320 4500
Important
1 Auxiliary vent/tank fill port 4 Swivel air input with filter For high cycle applications
2 Hydraulic output 5 Filtered permanent tank vent electric pumps are
recommended.
3 Gauge mounting port 6 Adjustable pressure relief valve
7 Air pendant air input
Product Selection
Pump 3000 series Oil flow 1) 5000 series Oil flow 1) Max. Reservoir Usable Air Air
type Model 3000 series Model 5000 series hydraulic size 2) oil capacity 2) pressure consumption
Number Number pressure range
litres
hor. vert.
l/min l/min bar litres mount. mount. bar l/min kg
PATG PATG-3102PB 3,0 PATG-5102PB 2,0 350 2,4 2,1 1,1 1,7-8,6 340 8,6
PACG PACG-3002PB 3,0 PACG-5002PB 2,0 350 2,4 2,1 1,1 1,7-8,6 340 8,6
PASG PASG-3002PB 3,0 PASG-5002PB 2,0 350 2,4 2,1 1,1 1,7-8,6 340 8,6
PAMG PAMG-3402PB 3,0 PAMG-5402PB 2,0 350 2,4 2,1 1,1 1,7-8,6 340 11,3
PARG PARG-3102PB 3,0 PARG-5102PB 2,0 350 2,4 2,1 1,1 1,7-8,6 340 10,5
1) At 0 bar hydraulic and 7 bar air pressure.
2) TurboII air-hydraulic pumps are also availble with 5 litres reservoir.
To order replace 2 in model number with 5. © 2006 77
Electric Driven Workholding Pumps Application & Selection
Shown: ZW5111SWE100
Customize to your needs
Swing cylinders
Work supports

• Various models including electric controls and


isolating valves
• Stackable to 8 VP-series valve stations high
• Customer adjustable relief valve
• Glycerine dampened pressure gauge G-2517L on
Linear cylinders

pumps with VP-series valves


• 230/400 Volt - 50Hz - 1,1 kW Motor
Power sources

02_003

Enerpac’s workholding pump unit features an


innovative range of zero leakage, poppet design,
directional valves. With the modular valve design,
various independent single-acting or double-acting
circuits can be realized.
ZW5-Series Oil flow vs hydraulic pressure
2,5

Application 2,0
These advanced workholding pumps, operating at
Oil flow (l/min) ➔
maximum 350 bar hydraulic pressure, are highly 1,5

suitable for production tooling applications – offering


1,0
the optimum in terms of compact size for required oil
flow and pressure rating and customization to your 0,5
specific needs.
0
0 150 200 250 300 350
Enerpac electric pump used in conjunction with swing
Pressure (bar) ➔
cylinders, work supports, directional valves, control
valves and sequence valves can provide a complete
clamping solution. The pressure switch allows the unit
to be fully automated.

Product selection
Oil Pressure Voltage Usable Valve Model
Flow Range and oil models number
rate current capa- included
50Hz city 2)
l/min bar V@A litres kg
▼ With manifold for VP-series modulair valves, no electric controls
1,64 100-350 230 @ 3,3 10,0 – ZW5VPSEE100 65
1,64 100-350 400 @ 1,9 10,0 – ZW5VPSWE100 65
▼ With manifold for CETOP 03 valves, no electric controls
1,64 100-350 230 @ 3,3 10,0 – ZW5C03SEE100 65
1,64 100-350 400 @ 1,9 10,0 – ZW5C03SWE100 65
▼ For 2x Single-Acting circuits
1,64 100-350 230 @ 3,3 10,0 1x VP-41 ZW5141SEE100 77
1,64 100-350 400 @ 1,9 10,0 1x VP-41 ZW5141SWE100 77
▼ For 1x Double-Acting circuits + Isolating Valve 1)
for A-port
1,64 100-350 230 @ 3,3 10,0 1x VP-11 ZW5111SEE100 77
1,64 100-350 400 @ 1,9 10,0 1x VP-11 ZW5111SWE100 77
▼ For 2x Double-Acting circuits + Isolating Valves 1)
for all A-ports
1,64 100-350 230 @ 3,3 10,0 2x VP-11 ZW5211SEE100 80
1,64 100-350 400 @ 1,9 10,0 2x VP-11 ZW5211SWE100 80
1)
Isolating Valve is Pressure Switch PSCK-8.
2)
ZW5-series pumps comes standard with 10 litres reservoir. (4, 8, 20 or 40 litres
78 © 2006 reservoir is optional).
Dimensions & options ZW5 series
Flow: 1,64 l/min

Pressure: 100-350 bar

Motor: 1,1 kW
ZW5-series Shown: ZW5211SEE100 with standard 10 litres reservoir Reservoir: 4 -40 litres

Electric Control Box E Bombas eléctricas


Adjustable relief valve
F Centrale hydraulique
G-2517L
PSCK-8
D Modulare Spannpumpe
TRK-2
VP-11

Power sources
555
533

290

5
155 Options

6 VP-series,
419 (10 ltr) 305 modular valves

Valves
447 384 (10 ltr)
88 
 Pressure gauge  Directional valve
 Pressure switch  Oil level glass VFC-3 Inline
 Tie Rod Kit  Oil drain Flow control
valve

components

Product specifications 89

System
Pump Voltage Phase Continous Motor Motor Motor Sound Pressure
series operation capacity speed protection Level
at class
switches
350 bar
89 
Volt kW RPM dBA
Hoses and

Yellow pages
ZW5.... 230 1 50% 1,1 1390 IP54 75
ZW5..... 400 3 50% 1,1 1390 IP54 75 couplers

108 

High pressure
Valve options filters
The VP-serie modular 109 
directional valves with all its
VP-41 options, stackable up to 8 Fittings
stations high.
88-91 
110 
PSCK-8
Important
Oil should be replaced
every 500 working hours or
4 times a year whichever
comes first to ensure long
life.

VFC-3 PRV-1
Output flow rate should be
matched to hydraulic
PB-1 components used in the
system.
TRK-3

www.enerpac.com © 2006 79
Electric Driven Workholding Pumps Applications & Options
Shown: ZW5111SWE100
ZW5VPSEE100 with manifold for VP-series or CETOP Basic pumps
Swing cylinders

03 valves, without electric controls and gauge


Work supports

Customize to your needs with


the Enerpac VP-series valves
and options or choose your own
CETOP 03 valve.
Linear cylinders

02_004
Power sources

ZW5 series
These advanced workholding
pumps, operating at maximum
350 bar hydraulic pressure, are
highly suitable for production
tooling applications – offering Isolating valves
ZW5111SEE100 For 1x Double-Acting circuit and
the optimum in terms of
Isolating Valve for A-port For applications where clamping
compact size for required oil
flow and pressure rating and PS 1 pressure has to be maintained,
customization to your specific isolating valves are an economic
needs. and safe solution.
VP-11
The pressure switch (PS 1)
Application switches in the hydraulic line to
the cylinder actuates the valve
Enerpac electric pump used in
with a closed center position and
conjunction with swing
isolates the circuit when the
cylinders, work supports,
preset pressure has been reached.
directional valves, control valves G-2517L In case of pressure drop the
and sequence valves can
PS 0 switch opens the valve to
provide a complete clamping
compensate.
solution. The pressure switch
allows the unit to be fully
For some particular applications,
automated.
i.e. when a workpiece has to be
positioned and clamped with
different forces, you can set
different isolating valve pressures
for the independent circuits.

ZW5141SEE100 For 2x Single-Acting circuits Pressure switch (PS 0) switches


the motor off at maximum
pressure; in case of pressure drop
❚ Enerpac VP-series valves due to activating circuits, the
stackbuilded on ZW5211SWE100. VP-41 motor restarts.
The pressure switch PSCK-8 is
mounted directly onto the
endplate of Tie Rod Kit TRK-2.

G-2517L
PS 0
02_005

80 © 2006 www.enerpac.com
Applications & Options ZW5 series
CSM-572 ZW5211SEE100 for 2x Double-Acting circuit and Flow: 1,64 l/min
Isolating Valve for all A-ports
SLRD-92 SLRD-92 Pressure: 100-350 bar
PS 1 PS 2 Motor: 1,1 kW

Reservoir: 4-40 litres


VP-11 VP-11

E Bombas eléctricas
F Centrale hydraulique
D Modulare Spannpumpe

MVPM-5 WFL-222
PS 0
G-2517L

Power sources
ZW5211SEE100

Options
Application example

Valves
Building the right workholding Sequence
system for a specific production valves
tooling requirement is best
92 
achieved by observing the Basic
System Set-up in our “Yellow
Flow control

components
Pages” ( 113 ). valves

System
96 

Hoses and
couplers

Electric Scheme 108 

Yellow pages
Shown the electric scheme of
the ZW5211SWE100 (400 volt) High pressure
filters
for two double-acting circuits
and isolating valves (pressure 109 
switches) in both A-lines.
Hydraulic oil
ZW5211SWE100
F1, 2A F3, 2A
~ 109 
400V~

+
27V~

– CRI
~
Fittings
F2, 2A – 1
1 3 5 T1
F1
21 110 
SO
22 1
13 1 23 13 23 VP-series
S1 S2
2 4 6 14 2 24 14 2 24 Valve options

PS2 88-91 
1 3 5 PS1
6
5
4

KO
8

2 4 6
3

2 4 5 6 8 10 12
2 4
PS0
L1 L2 L3 U V W

3 7 9 11 13
M 3~ K0
– – – –

© 2006 81
Air hydraulic boosters Application & selection
Shown: AHB-46, B-5003, B-3006
For high production applications
Swing cylinders
Work supports

• High speed operation


• Extended service life
• Constant hydraulic output
• Large oil delivery per stroke allows quick filling of cylinders
for clamping or punching
Linear cylinders

AHB series Boosters


• Fiberglass wound air chamber eliminates possibility of rust
due to moisture in air system
• Designed for fully automated production applications
99-077-2
Power sources

• Double-acting, high speed operation of air piston

AHB and B series boosters B series Boosters


Large effective area of air piston allows compressed • One-shot spring return
air to generate high output hydraulic pressure.
• Aluminium construction
• Built-in stroke sensor for automatic cycle operation
30 VDC switch closes 25 mm before end of full air piston stroke
• Internal self-bleeding
Automatically purges air from system when booster piston
is at highest point in circuit

VA-42
Manual
control valve
RFL-102 Serie AHB
Air filter regulator Air hydraulic booster

Serie G
350 bar
gauge

V-19
Check valve

To hydraulic
system

❚ In an automated clamping set-up with both hydraulic


and pneumatic components, AHB series boosters are
used as a power source for the hydraulic system.
Hydraulic system schematics
Complete power systems
eliminate guesswork of
selecting valves and other
system components. Plug in
your 1 to 8 bar shop air line AHB-46
and connect your hydraulic
components for a total
system.
VA-42

RFL-102 V-19
98-010

82 © 2006 www.enerpac.com
Dimensions & options AHB/B series
AHB series – Oil pressure vs Air pressure B series - Oil pressure vs Air pressure Ratio: 1:16 - 1:64
350 350
Pressure: 110 - 350 bar

03
66

46

50
300

B-
B-

B-
AH
275 AH 34 Oil flow: 60-295 cm3/stroke
06
Oil pressure (bar) ➔

Oil pressure (bar) ➔


B- 250 30
AH B-
200 200 Air: 27-64,1 dm3/cycle
150
140 -17
AHB E Multiplicadores
100
40
50 F Multiplicateurs
0
0 1,7 3,4 5,1 6,9 8,6
0
0 2 4 6 8 D Druckübersetzer
Air pressure (bar) ➔ Air pressure (bar) ➔

Power sources
AHB series
Options
Air Oil Gauge
connection reservoir G1/8" port Air valves
34 230
*
G3/8"

**
97 
22

310
226

Valves
HF-series
113

G3/8"
57 1)
97

Hydraulic oil
39 220 209 12,7
25,4

255 222 16 108 


504 254

1)
Fittings
Ø 71,9 mm for model AHB-17

components
System
* Oil connection (G1/4”) for model AHB-17
** Oil connection (G1/4”) for model AHB-34, -46, -66 110 
*** Adaptor to 3/8” NPT air connection is included.

Important
B series
Boosters can provide high

Yellow pages
Air Oil fill Gauge oil flow rates based on the
connection port port volume of incoming air.
3/8 BSPT 1/2 BSPP 3/8 BSPP
Do not exceed the flow rate
requirements of the
components being used.
222
117

Stroke
sensor
ø 11 For vertical mounting of
71 216 156
booster, an elbow fitting is
121 183
recommended for the oil
484 238
reservoir.

Product selection
Oil pressure Oil volume Air to oil Model Air Air Hydraulic Hydraulic Air operating
per stroke pressure number consumption piston piston stroke pressure
bar ratio per cycle 1) diameter diameter

at 5 bar at 7 bar dm3


air pressure air pressure cm3 at 6 bar air mm mm mm bar kg
▼ AHB series
83 110 295,0 1:16 AHB-17 62,6 203 51 145 1-8 18,8
175 235 139,3 1:34 AHB-34 63,6 203 35 145 1-8 16,8
240 315 100,0 1:46 AHB-46 63,9 203 30 145 1-8 16,4
330 – 73,7 1:64 AHB-66 64,1 203 25 145 1-5 16,0
▼ B series
155 210 101,6 1:30 B-3006 27 180 31 132 3-9 14,0
260 350 60,6 1:50 B-5003 27 180 24 132 3-9 14,0
1)
One cycle = advance + retract stroke.
Note: Seal material: Buna-N, Polyurethane.
© 2006 83
Oil/oil intensifiers
Shown: PID-402
High flow units intensify low inlet oil
pressure to high outlet pressure
Swing cylinders
Work supports

• Internal bypass valving enables high output flow rates


• Wide range of intensification ratios allows for adapting to various operating
pressure requirements
Linear cylinders

• Compact and self-contained design allows for ease of installation


• Includes dump valve, eliminates the need for an external pilot check valve
• Select fit of all internal components provides long operating life

Intensifier principle
Power sources

99-055

PID series • When oil is supplied to the inlet (IN) • Free flow from the cylinder to tank
port it flows freely past the check occurs when the directional control
When hydraulic pressure from valves (CV) and the dump valve to the valve is switched to supply the R-port.
an existing power source is cylinder and advances it.
limited, Enerpac oil-to-oil
• As the inlet pressure increases the • A 10 micron filtration is essential in the
intensifiers serve to increase
oscilating pump (OP) automatically supply circuit to ensure trouble free
output pressure to satisfy the
increases the outlet pressure by the operation (see options).
required application. chosen intensification.
• Once the maximum pressure is
reached, the pump frequency lowers
and balances at the maximum
pressure.

PID series

Low
pressure

High
pressure
❚ PID-Series intensifier utilizes low
pressure machine hydraulics to To cylinder
power clamping cylinders.

Product selection
Maximum Pressure Maximum Maximum Model Inlet
output intensification input flow output flow number pressure
pressure ratio range

with min. - max.


bar l/min l/min dump valve bar kg
640 1 : 3,2 15,0 2,5 PID-322 20 - 200 1,2
700 1 : 4,0 14,0 2,0 PID-402 20 - 175 1,2
700 1 : 5,0 14,0 1,6 PID-502 20 - 140 1,2
98-021

700 1 : 6,6 13,0 1,3 PID-662 20 - 106 1,2

84 © 2006 www.enerpac.com
Dimensions & options PID series
System set-up information Ratio: 1 : 3,2 - 1 : 6,6

Flow: 1,3 - 2,5 l/min

With dump valve Pressure: 65 - 700 bar


(PID models) E
R
PID
The intensifier with the dump IN E Multiplicadores
valve is used to achieve high
pressure on the advance side F Multiplicateurs
of a double-acting cylinder. D Öl-Öl Druckübersetzer

Low
pressure

Power sources
With external dump valve
E
In a circulating system where
the pump’s oil flow is higher
than the maximum inlet oil flow
of the intensifier, an external IN
check valve and flow control PID
valve reduces the pump’s oil R
flow.

Valves
This application can be set up
when machines are equipped Low
with low pressure hydraulics pressure
but the pressure to clamp the
workpiece must be higher.
Options
FL-series,

components
High pressure

System
filters
109 

Directional
valves

Yellow pages
88 

FZ-series
Fittings

110 

PID models with dump


valve provide an
economical means of
relieving pressure from the
system.

Product dimensions in mm [ ] Can be panel mounted into


machine (M24x1,5 thread).

PID Serie 18,8-19,2


2,3-2,7 G1/4" Important
Do not exceed maximum
allowable inlet pressure.
49,95-50,00
ø29,8-30,0

27,8-28,0

R
M24x1,5
G1/4"

IN
10 micron inlet filtration is
essential to ensure trouble-
84,8-85,2 40,9 free operation.
109,8-110,2

© 2006 85
Valves
Technical support Valves

Refer to the “Yellow Pages” of this Valves – Controlling the operation of your clamping
catalog for:
system requires the use of many specialized
• Safety instructions
directional, pressure and flow control valves.
• Basic hydraulic information
• Advanced hydraulic technology Enerpac has the complete line of valving components
• FMS (Flexible Machining Systems) to complement any hydraulic system. Choose from
technology
electric directional valves and a wide variety of
• Conversion charts and hydraulic
symbols pressure control, flow control and specialty valves to

113  provide the control and automation that your


application needs.

86 © 2006
▼ series ▼ page

Modular directional valves VP 88

PSCK
Pressure switches, Flow control valve 89
VFC

TRK
Tie rod kits, Remote/porting manifolds 90
WM, PB

Pressure reducing valves PRV 91

MVPM
Sequence valves 92
V

Pilot operated check valves MV, V 93

MH, HV
Accessory valves 94 - 95
PLV, V

Flow Control Valves VFC 96

VA, VR
Air valves and accessories 97
RFL, QE

www.enerpac.com © 2006 87
Modular directional valves VP series
Shown: VP-11
Solenoid directional valves Pressure: 350 bar
Swing cylinders
Work supports

Max. Flow: 15 l/min @ 0 bar

• Dual poppet valve design for zero internal Voltage: 24 VDC


leakage
E Válvulas de control
• Inlet check-valve standard
• High cycle switching F Electrodistributeurs
Linear cylinders

• Stackable to 8 valve stations high D Wegesitzventile


• 17 - 350 bar operational pressure
• Oil flow capacity 7 l/min @ 350 bar
• Oil flow capacity 15 l/min @ 0 bar
• G1/4” oil connections and integrated filtration
99-017
Power sources

VP-series Options
Solenoid directional valves PB-1 Auxiliary
control the direction of the oil block
flow to each cylinder port. VP series
90 
Application
Valves

Tie Rod Kits


142

VP-valve in combination with all


its options in the drawing and Pressure switch
photo below. For remote ports at both 90 
sides for
mounting of these valves use PSCK-8, 9
WM-10 manifold ( 90).
40

Flow control
G1/4" ports at both Oil flow vs pressure drop
sides for VFC-3 10
A B
28
40

9
8
Pressure drop (bar) ➔

60
12

7
92 6
5
4
3
2
1
0
0 1 2 3 4 5 6 7 8
Oil flow (l/min) ➔

Flow Path 1)

VP-11
Product selection
❚ Enerpac VP-series valves Voltage @ current Model Used
stackbuilded on a workholding number with VP-21
cylinder(s)
pump.
at 50/60 Hz
@ 1,13 Amps
▼ 4/3 Closed centre VP-31
24 VDC @ 1,13 A VP-11 1x DA / 2xSA
▼ 4/3 Float centre
24 VDC @ 1,13 A VP-21 1x DA / 2xSA
VP-41
▼ 3/2 Normally closed
24 VDC @ 1,13 A VP-31 1x DA / 2xSA
▼ 3/2 Normally open
24 VDC @ 1,13 A VP-41 1x DA / 2xSA VP-51
▼ 3/2 one port normally open, one port normally closed
99-030

24 VDC @ 1,13 A VP-51 1x DA / 2xSA


1)
Note: DIN 43650 electrical connector included. Valve weight 3,0 kg. See page 129 for full hydraulic scheme.

88 © 2006 www.enerpac.com
Pressure switches, Flow control valve PSCK, VFC series
Shown: PSCK-8, VFC-3
Pressure: 350 bar To control your
Flow: 7 l/min @ 350 bar
hydraulic system
Voltage: 24 VDC • Mounts directly into VP-series modular valves
• In-line installation
E Presostatos
• Cartridge type flow control valve and pressure
F Pressostats switches can be manifold mounted for remote
D Druckschalter use
• Lockable adjustment screw on PSCK models

A B

99-020
PSCK-8, 9 Mounting dim.

Options Hydraulic PSCK-8, 9


connection
Flow control Adjustable pressure switches

6,0
40,0 75,0 M4
valves will open or close electrical
contacts when the desired

9,0
96  pressure value is reached.
ø 3,0-5,0
61,0

Valves
Pressure Application
reducing
To open or close an electric
13,0
valves

28,0
91  circuit when a preset pressure
28,0 value is reached. The electrical
min. 35 circuit is used to control further
working cycles, such as

components
actuating control valves or to

System
VFC-3 Back pressure vs flow return
terminate a working cycle.
10 VFC-3 VFC-3 Mounting dimensions
Directly mounted into Enerpac
Flow direction B-A
8 118° VP-series valves.
Back pressure (bar) ➔

Protective cover ø17,0-18,0


6 ø10,0-10,3
0,05 C VFC-3
1,0

M8x1

Yellow pages
4 1,6
M8x1
Screw-in throttle type valve to
18,0-19,0
max. ø5,0

4,0 Hex. Adjustment screw control the amount of oil flow to


14,0

min. 25,0

2
15,0

the hydraulic cylinder.


0
0 2 4 6 8 10 B
Oil flow (l/min) ➔ A Application
32,0 C ø5H11 Used to control cylinder speed
13,0 Hex. Lock nut
in hydraulic circuits. Directly
mounted into Enerpac VP-series
valves or custom made
Product selection manifolds for remote
Solenoid Model Hydraulic Pressure Deadband Maximum applications.
voltage @ current number scheme range oil flow

❚ PSCK-8 and VFC-3 directly


at 50/60 Hz bar bar l/min
mounted on VP-valves.
▼ Pressure switch

24 VDC @ 2 A PSCK-8 100 - 350 18 - 35 7

▼ Pressure switch

24 VDC @ 2 A PSCK-9 20 - 210 6 - 15 7

▼ Flow control valve


Screw-in A B
throttle VFC-3 0 - 350 – 7
99-028

valve

© 2006 89
Tie Rod Kits, Remote/Porting Manifolds TRK, WM, PB-series
Shown: WM-10, TRK-4, PB-1
Simplifies valve and Mounting: 1-8 VP valve stations
Swing cylinders

accessory mounting
Work supports

Pressure: 350 bar max.

Flow: 15 l/min
TRK-series Tie Rods
• Connects 1 to 8 VP-series valves E Pernos de montaje de válv.
• Provide leak-free sealing valves
F Vis de montage de distrib.
Linear cylinders

• G1/4” oil connection


D Zugstangen
WM-10 Remote manifold
• Allows remote VP-series valve mounting
M4
• Adjustable relief valve incorporated
• G1/4” oil connection M3 P
PB-1 Porting manifold P T M5
99-005
Power sources

• Provide 3 auxiliary pressure lines

TRK-series
• G1/4” oil connection Options
Tie Rod Kits mount Enerpac VP- Pressure
series modular valves to the switches
WM-10 manifold or pump
mounted manifold and can 89 
TRK
accommodate one to eight VP- Endplate
Valves

valve stations. VP-series


directional
Cap nut A valves
M6 88 
Seal washer Tie rod
WM-10 Gauges

Remote manifold allows


mounting of VP-series modular 106 
valves to a remote location from WM-10 PB-1
the pumping unit. This manifold
has a built-in adjustable relief Adjustable
valve. relief valve
72,5

M6
25

40
40

PB-1
12

Porting manifold provides three 55 M8


pressure ports for auxiliary lines G1/4"(2x) G1/4"
(3x)
or accessories, such as a
9,6

pressure gauge. Mounts


40

40
18

R
between VP-series modular P
valve stations using TRK-series 14 34
tie rod kits. 46 92
92

❚ Tie rods mount VP-series valves


Product selection Product selection
and accessories to manifold, Quantity Model Tie rod Mounting Oil Model Hydr. Maximum
providing leak-free sealing. of stackable number length thread ports number scheme pressure
VP-series
directional
valves
mm mm BSPP bar
▼ Tie rod kits ▼ Remote manifold with pressure relief
1 TRK-1 85 M6
2 TRK-2 125 M6 2x G1/4” WM-10 350
3 TRK-3 165 M6 P T

4 TRK-4 205 M6 ▼ Porting manifold (P port connection)


5 TRK-5 245 M6 M4

6 TRK-6 285 M6 1
3x G /4” PB-1 350
M3 P
7 TRK-7 325 M6 M5
99-035

8 TRK-8 365 M6

90 © 2006 www.enerpac.com
Pressure reducing valves PRV series
Shown: PRV-1
Pressure: 350 bar Precise control of
Flow: 7 l/min
hydraulic pressure

E Válv. reguladora de presión • Stackbuilding with VP series modular valves


F Valve de pression réglable • Stackable for multiple pressures on one valve
stack assembly
D Druckreduzierventil
• Tool adjustable knob can be locked
• Precise control of pressure
A P
A P • G1/4” oil connection
• Remote mount PRV-3
R

99-021
Options
VP-Modular PRV-series
valves
These valves regulates system
88  pressure for all subsequent
valves, according to the
Pressure adjusted pressure. Maintains a
switches constant pressure in a

Valves
secondary circuit. Includes a
89  check valve that prevents
pressure drop on secondary
Tie rod kits side.

90  Application

components
Used when a hydraulic supply

System
Fittings with a higher pressure (primary
side) must also be used for
another circuit with a lower
110  pressure (secondary circuit).

PRV-1 can be stack builded

Yellow pages
between VP-series valves.
PRV-3 is for remote mounting.
PRV-1 The cartridge from PRV-3 can
be removed from manifold for
PRV-3
direct integration into gundrilled
Adjustable fixture.
193

pressure
reducing valve
Port for
pressure
153

switch
12
40

PSCK-8, -9
G1/4"
16

G1/4"
16

92
8,4
38

50

A ❚ PRV-1 connected with remote


manifold WM-10.
40

G1/4" 12 16
34 35 50

Product selection
Mounting Adjustable Maximum Built-in Model Oil Maximum
style pressure pressure adjustable number ports oil flow
range pressure
relief valve

bar bar bar BSPP l/min kg


VP-series 30 - 300 350 – PRV-1 G1/4” 7 1,6
99-024

Remote 30 - 300 350 – PRV-3 G1/4” 7 1,3

© 2006 91
Sequence valves MVPM, V-series
Shown: MVPM-5
Pressure dependent Pressure: 350 bar max.
Swing cylinders

sequence control
Work supports

Flow: 4,1 - 6,0 l/min max.

MVPM-5 E Válvulas de secuencia


• Direct accurate pressure setting F Valves de séquence
• Pressure setting between 35 - 350 bar for D Folgeventile
secondary circuit is secured with lock nut
Linear cylinders

V-2000
• Direct accurate pressure setting P A

• Pressure setting betweeen 14 - 140 bar for


secondary circuit
• Flag indicator appears every time the valve is
99-107
Power sources

operated Options
Sequence valves Gauges
Sequence valves block the oil to
a secondary hydraulic circuit 106 
until pressure in the primary
circuit reaches a preset level.
The sequence valves have a MVPM-5 Pressure drop vs oil flow
Valves

built-in check system to allow 35


the oil to flow back without
30
external piping.

Pressure drop (bar) ➔


Pressure settings for the V-2000 25

can be adjusted by screwing the 20


slotted pin in or out. The 15
pressure settings for the other
10
models is adjusted by loosening
the jam nut and turn the set 5

screw to reach your setting. 0


0 2 4 6 8 10 12
Oil flow (l/min) ➔
Application
The sequence valves can be
mounted in-line or fixture
mounted using mounting bolts. V-2000 7 MVPM-5
A typical application for the 1/8"-27NPT
sequence valve would be to A manifold
build pressure within work
15,7

ports
35

supports before the swing ø 4,8


6,6

cylinders are applied to the P


142
1/8"
supported part, to prevent 38 -27NPT
deflection in the part. 51 A
G1/4"

34
50

P
65

19
26,5
12,5

❚ Two MVPM-5 sequence valves


used in conjuction with Enerpac
38

13 28,5
MCA-series Auto Coupler to A 37
provide system automation. 50
79
87 60

Product selection
Pressure Maximum Maximum Model Oil ports Opening
adjustment pressure oil flow number pressure
range check valve

bar bar l/min bar kg


14-140 350 4,1 V-2000 1/8”-27N P T – 0,9
99-119

35-350 350 6,0 MVPM-5 G 1/4” 1,4 1,3


Seal material: Buna-N. Manifold O-rings included with MVPM-5. For manifold mounting installation information consult
Enerpac for surface preparation.
92 © 2006 www.enerpac.com
Pilot operated check valves MV-series
Shown: MV-72, MVM-72
Pilot ratio: 7:1 To hold cylinder load and
Flow: 38 l/min max. ensure remote unlocking

E Válvulas antiretorno pilotada • Fast check-off response


F Clapets antiretour piloté • Hardened seats ensure long life and positive
pressure holding
D Rückschlagventile
• Built-in accumulator to maintain system
pressure
• Mounting holes
• Manifold mount body MVM-72

99-109
Options
Fittings MV-series
Pilot operated check valves
110  check the oil flow with a built-in
pilot circuit providing fast,
automatic check-off for your
Product selection workholding applications.

Valves
Pilot Accumulator Maximum Maximum Model Oil ports Optional
The pilot operated check valves
ratio included oil flow pressure number charging with built-in accumulator help to
tool for maintain system pressure due to
ACL
minor oil loss.
l/min bar kg
7 : 1 – 38 350 MV-72 G 1/4” – 1,8 Application

components
Added capability to open with

System
7 : 1 ACL-22 38 350 MV-722B G 1/4” WAT-2 2,7
7 : 1 ACL-202 38 350 MV-7202B G 1/4” WAT-2 3,4 pilot pressure to allow cylinders
7 : 1 – 38 350 MVM-72 G 1/4” – 1,4 to retract. By using a pilot
For more information on ACL-series Accumulators see page 104. operated check valve, cylinder
retraction can be accomplished
automatically without operator
MV-722B, -7202B MV-72 MVM-72 activity.

Yellow pages
K E A
G L F G F
28,4
P
A B H A
z 7,9
G
Manifold 73,2
B ports 50,8
ø 4,75-4,93 28,7

A D B C
z A
C B C
28,7 P
D
A
D E
L K
M K L
H P z
H B A G
G F
E

Product dimensions in mm [ ]
Model A B C D E F G H K L M
number

MV-72 89,0 63,5 55,6 7,1 73,2 28,7 G1/4” 31,8 50,8 73,2 –
MV-722B 89,0 71,1 184,2 7,1 73,2 28,4 G1/4” 31,8 73,2 50,8 145
MV-7202B 89,0 92,4 181,1 7,1 73,2 28,4 G1/4” 31,8 73,2 50,8 185
MVM-72 89,0 63,5 38,1 7,1 28,7 28,4 G1/4” 31,8 44,5 73,2 –
Seal material: Buna-N. Manifold O-rings included with MVM-72. For manifold mounting installation information consult
Enerpac for surface preparation.
© 2006 93
Accessory valves Application & selection
Shown: HV-1000A, V-17, V-10, V-12, V-152
Your hydraulic control solution
Swing cylinders
Work supports

• Regulate oil flow or system pressure


• All valves feature NPT or SAE porting to insure against
leakage at rated pressure
• Can easily be installed in any system
• All valves are painted, coated or plated for corrosion
resistance
Linear cylinders

Product selection
Valve type Maximum Model Oil
pressure number ports
99-086
Power sources

Accessory valves bar


Enerpac accessory valves, available in a wide Holding valve, air pilot 210 HV-1000A 1/8”N P T
variety and many configurations to control Holding valve, modular 210 MHV-1 1/8”N P T
hydraulic pressure or oil flow. These valves are Presssure limiting valve 210 PLV-40013B 1/8”N P T
used in conjunction with other valves and Manual shut-off valve 350 V-12 SAE #4
system components to provide full automation Auto-damper valve 700 V-10 1/2”N P T
Valves

and control. Safety check valve 700 V-17 3/8”N P T


Presssure relief valve 700 V-152 1/8”N P T
Application
Accessory valves are used to automate clamp
cycles, prevent pressure loss and provide
additional operator and component safety.
Product specification
HV-1000A Air pilot holding valve
• Holds fluid under pressure offering P A
independent control of different
branches of the same
fixture 110
57
• Valve can control the pilot
1/4"-18 NPT

air and the booster in


P
sequence
• Max. oil flow 5 l/min
1/8"-
• Works with the VA-42 four- Air inlet
27NPT
7,1
way air valve and a 48
booster 25,4
A
51

MHV-1 P
❚ V-17 Safety check valve installed on a fixture. Modular holding valve
• Allows separate operation of clamping A
fixtures with a single power source
• Ideal for applications when 129
fluid feed lines are 19
impractical. If system 7,1
presssure is interrupted,
the MHV-1 will hold the
35

pressure beyond the valve


1/8"-27NPT

• Max. oil flow 5 l/min


• To release system
pressure, rotate valve
84

handle in either direction A P


35

90˚ to release and retract


system pressure
1/8"-
99-122b

35 27NPT

94 © 2006 www.enerpac.com
Dimensions & options MH, HV, PLV, V-series
Pressure: 0 - 700 bar

Flow max.: 5 - 30 l/min


PLV-40013B 89
Pressure limiting valve 17,3 E Válvulas de control
A P
• Allows precise control of
P F Valves de contrôle
pressures reaching specific

38
clamps D Regelventile
• When pressure build-up reaches a preset level, Adjustable pressure screw
the valve closes, stabilizing pressure to that
section of the fixture 41,5
P

7,1
• Pressure adjustment between 14 - 105 bar P A

38
19
• Max. oil flow 5 l/min
A
1/8"-27NPT (2x) 30,5

V-12 Manual shut-off valve


130
• Ball type valve can be used for
the master system shut-off or
for isolating separate circuits
59

on a fixture
• Viton seals standard

Valves
• Straight through design for easy system 35
12

plumbing and installation 25 68


SAE #4 .437-20UNF
• Fully open allows high flow return of oil
• Max. oil flow 12 l/min

components
V-10 Auto-damper valve

System
38
28
• To protect gauge during high
cycle applications
38

• Creates a flow resistance when


load is released suddenly.
No adjustments are necessary 119
Options

Yellow pages
• Fits directly into GA-series gauge adaptor 1/2" -14NPT
VA-42
Air valve
97 
V-17 Safety check valve
101
• Ruggedly built to resist shock Gauges and
and operate with low adaptors
31

pressure drop 
3/8" -18NPT 106
• Closes smoothly without pounding
• Max. oil flow 30 l/min Hoses and
couplers
108 

V-152 Pressure relief valve Fittings


193 max
• Limits pressure developed by ø 38 38
the pump in hydraulic circuit,
79

thus limiting the force imposed 110 


on other components
• 55 - 700 bar adjustment range; 115 Important
±3% repeatability 3/8" -18NPT (3x)
• Valve opens whenever preset pressure is Valving help
reached. To increase pressure setting, turn handle clockwise See Basic System Set-up
• Max. oil flow 30 l/min and Valve information in our
“Yellow Pages”.
• Includes 1 m return line hose kit

113 

© 2006 95
Flow control valves VFC-series
Shown: VFC-1, VFC-2
Regulate the flow of oil Max. Flow: 38 l/min
Swing cylinders
Work supports

Pressure: 0 - 350 bar

• Color coded flow indicator


E Válv. reguladoras de caudal
• Free flow return
F Valves de control débit
• Fine metering capability
• Lockable D Stromregelventile
Linear cylinders

• Standard Viton seals


A B
99-025
Power sources

Options
VFC-series Fittings
Provide repeatable oil flow
control. The internal check valve 110 
allows metered flow in one
direction and free flow in the High pressure
opposite direction. Precise filters
Valves

control is achieved with a micro-


meter style adjustment knob, 109 
which can be locked with the
set screw. Inline Flow
Control Valve
Application 89 
Use VFC-series flow control
valves in-line with the Enerpac
WE-series workholding pump to
protect your components from
damage due to high flow rates. VFC-1, -2 Pressure drop vs oil flow VFC-1, -2
Flow setting (in turns) ➔
1 2 3 4 5 6 7
ø 29
100
90
80
Pressure drop (bar) ➔

70
60
72
65

50
40
30
20
25

10 Flow direction A-B


A B
0
0 10 20 30 40 50 34
Oil flow (l/min) ➔
55
VFC-1 SAE #4
VFC-2 G1/4"

❚ In-line installation of a VFC-1


flow control valve. Product selection
Maximum Pressure Oil Model Flow path Maximum
oil flow range ports number pressure drop

l/min bar bar kg


▼ Flow control valves
A B
38 0 - 350 SAE #4 VFC-1 105 0,8

A B
38 0 - 350 G 1/4” VFC-2 105 0,8
99-041

Seal material: Viton.

96 © 2006 www.enerpac.com
Air valves and accessories V, RFL, QE-series
Shown: VA-42, VAS-42
Air Pressure: 0 - 10 bar To control and regulate air supply

E Válvulas de aire
F Valves à air VA-42 Manual operated air valve, 5-way, 2-pos.
D Luftventile • For control of boosters
• Viton seals standard
VAS-42 Solenoid operated air valve 5-way, 2-pos.
• For control of pump and boosters air supply
• Viton seals standard
• Solenoid: 120 VAC, 50/60Hz
Amperage: inrush 0,11 Amp, holding 0,07 Amp
Options • Maximum cycle rate: 600 cycles per minute

99_110
Gauges and VR-3 Rapid exhaust valve
adaptors • Enables booster to advance and retract faster
Air valves
106  • Instantly exhaust air supply from booster to
Enerpac’s line of directional air
atmosphere
Hoses and valves and accessories
couplers V-19 Air check valve complete your workholding
• Prevent rapid drop of air pressure to the booster system. Used to control air
108  operated hydraulic units, they

Valves
in the event of sudden loss of input air
increase your productivity and
Fittings RFL-102 Regulator-Filter-Lubricator efficiency.
• Regulates air pressure
110  • Filter air input Application
• Lubricates air motors with a fine oil vapor mist
VA-series directional air valves

components
• Maximum air flow 1500 l/min provide either manual or electric

System
QE-375 Air/Noise silencer control to air operated hydraulic
units. Accessories such as rapid
• Reduces noise level of exhaust air from pump to
exhaust, check valves, silencers
45 dBa and regulators complete the air
control system.

Yellow pages
• Accessory valves provide
VA-42 6,3
57
VAS-42 57 greater safety and more
6,3
25,4

25,4

efficient clamping cycles


• Recommended for use with
69
51

51

all air powered units


28,5 43 28,5 42,7
• Directional valves to control
25,4

3/8"-18NPT (5x) booster and pump air supply


25,4

3/8"-18NPT (5x)
102

• Remote air valve permits


either hand or foot operation
28,5 28,5 28,5
28,5 28,5 28,5 168
174

V-19 VR-3
Product selection 98 3/8"-18NPT (3x)

Maximum Model
32

60

pressure number
3/8" -18NPT
74 60

bar RFL-102 QE-375


▼ Air valves
3/8"-18NPT 40 28
2 - 10 VA-42
2 - 10 VAS-42
103

0-7 VR-3
241

0-7 V-19 3/8"-18NPT


▼ Accessories
0-9 RFL-102
0-9 QE-375
212

© 2006 97

Das könnte Ihnen auch gefallen