Sie sind auf Seite 1von 6

Client : GULF STEEL WORKS

Date :

Project : GULF IND. GRATING FACTORY

Dsgn By: AVB

PGT Job no:

Chk By : HDM

Structure:

SAND BLASTING SHED

22/06/15

Sheet no
REV :

INDEX
SR NO

TABLE OF CONTENTS

PG. NO.

INTRODUCTION

STANDARDS

DESIGN CRIERIA

DESIGN PHILOSOPHY

DESIGN CALCULATION

5.1

LOAD CALCULATION

5.2

STAAD INPUT

5.3

STAAD OUTPUT

Client :

GULF STEEL WORKS

Date :

Project :

Gosi Office Park

Dsgn By:

PGT Job no:

22/06/15

Sheet no
REV :

Chk By :

BASE PLATE & ANCHOR BOLT DESIGN CALCULATIONS AS PER AISC

Critical Reaction on base plate are (Refer STAAD output)


Node No.

916

Load Case No.

101

Vertical Load (FY, P)

697.0

kN

156.7 kips

Horizontal Load (FX)

37.0

kN

8.318 kips

Horizontal Load (FZ)

28.0

kN

6.295 kips

Resultant Shear Force

46.4

kN

10.43 kips

Maximum tensile force = T

0.0

kN

0 kips

RCC Column/Pedestal Dimensions


Length

406

mm

Width

406

mm

164836 mm2

255.5 in2

50

7.11 ksi

Area of concrete support

A2

Specified Comp. Strength of Conc. = f'c =

Grade of the base plate :

N/mm2

2.5

A36

Specified minimum yield strength

Specified minimum yield strength

=
=

36.3

ksi
x

36.3

6.9

250.47 N/mm

Base Plate Dimensions


Length of the base plate

406

mm

(along web)

16

Width of the base plate

406

mm

(along flange

16

mm

Thickness of the base plate

30

A1

164836 mm2

255.5 in2

bf

280

mm

11.02 in

280

mm

11.02 in

Provided Area of base plate = A1

255.496 in2

Provided Area of Pedestal = A2

255.496 in2

1. A1req. = (1/A2) . (P / 0.35 f'c)2

15.52

2. A1req. = (P / 0.7 f'c)

31.4857 in2

3. Aprov. = bf x d

121.52

Base plate area (l x b)

Structural Steel Column Size

Check for Base Plate Size:

Required Area of base plate :


in2

in2

Base plate A1req. < Aprov, Hence OK.

Client :

GULF STEEL WORKS

Date :

Project :

Gosi Office Park

Dsgn By:

PGT Job no:

22/06/15

Sheet no
REV :

Chk By :

Check for Bearing Pressure :


Actual bearing pressure = fp = P/(B x N) =

0.613 ksi

4.229 N/mm2

Allowable bearing pressure on support = Fp = 0.35 f'c sqrt(A2 / A1) <= 0.70 f'c
0.35 f'c sqrt(A2 / A1)

2.489 ksi

0.70 f'c

4.977 ksi

Hence Fp

2.4885 ksi

fp <= Fp,

Hence Safe

&

17.5 N/mm2

Effective projection of base plate along column depth (web)


m

70

mm

2.756 in

Effective projection of base plate along column width (Flange)


n

91

mm

n'

2.756

mm

q = 4 fp d bf / [(d + bf)2 Fp] <= 1.0


shall be lesser of

3.583 in

0.246

2 [1 - sqrt(1 - q)] / sqrt(q) & 1.0

2 [1 - sqrt(1 - q)] / sqrt(q)

0.53152

Hence

0.53152

1.465

in

37.21 mm

c = max (m, n,n')

3.583

in

91 mm

Th. of base plate = tp = 2.c.sqrt(fp / Fy)

0.931

in

24 mm

Provide base plate thickness as

. n' = . Sqrt(d.bf)/4

30

mm

1.181 in

Hence, OK
Design of Anchor bolts :
Bolt Grade : ASTM-A307, Fu = 60 ksi. (Refer AISC 13th Edition,

Use M

25

bolts

Capacity of bolt in
Tension (Tb) = 60.9 kN

Ref Table J3.2, AISC 13th Edition

Shear (Vb) = 32.4 kN

Ref Table J3.2, AISC 13th Edition

Nos. of bolt =

Tension per bolt (tb) =

0.0 kN

tb/Tb =

0.00 <=1 Hence Safe

Shear per bolt (vb) = 11.6 kN

vb/Vb =

0.36 <=1 Hence Safe

Resultant of Shear and Tesnion Ratio =

0.358 <= 1.2

Hence Safe

Since bolts are not in tension, provide minimum bolt length.


AS per AISC 13th Edition,
Min. Edge Distance = 32mm

Ref. Table J3.4M

Max. Edge Distance = 12xt & Max 150mm

Ref Cl. J3.5

Min. Spacing = 3 x bolt dia. i.e. 75mm

Ref. Cl. J3.3

Max. Spacing = 300mm

Ref Cl. J3.5

Permissible Shear Stress Fnv= 24 ksi (165 MPa)

Ref Table J3.2

Permissible Tensile Stress Fnt = 45 ksi (310 Mpa)

Ref Table J3.2

Client :