Sie sind auf Seite 1von 2

Stahlton Tech & Design Office

133 Waterloo Road, Hornby, Christchurch

ph 03 344 3014 Fax 03 344 3018

PO Box 8369 Riccarton, Christchurch 8440.

Web www.stahlton.co.nz

Rib&InfillFlooring

ProductDataSheet

RibandInfillflooringsystemincorporatesprestressedribs,permanentformworkinfills(usuallytimber)andaninsitu
concretetoppingtogiveanextremelylightweightandversatilesuspendedfloorrelativetootherconcretesystems.Temporary
proppingisusuallyrequired.
Stahlton'sRib&infillarenominally200mmwideandmanufacturedindepthsfrom100to300mmin25mmmodules.Usuallythe
ribsarespacedat900mmcentres.
OurlighterRibandInfillfloorsystemprovidesbenefitsbyreducingfoundationsandsupportstructure,idealfordifficultsites
whereaccessisachallenge.Forconcentratedloadsribsatclosercentrescanprovideevenmorecapacity.
OnyourdrawingscallupStahltonRib&Infillsaseg."150mmStahltonribs@900crs,250mmO/A".

Rib&InfillLoad/SpanTable(Indicativeonly)
Unfactoredmaximumsuperimposedliveload(Qb)inkilopascals(kPa),(assumingnosuperimposeddeadloadie.SDL=0kPa).
75mmof25MPatoppingconcreteonroughsawn25mmthickpinusradiatatimberinfillsonribsspacedat900mmcentres.
Simplysupportedspan(m)

Rib

Selfwt

depth(mm)

(kPa)

4.5

5.5

6.5

100

2.6

10.3

7.0

6.0

4.0

3.5

2.0

125

2.8

10.8

7.6

6.7

5.5

4.3

3.7

150

2.9

8.3

6.4

5.5

175

3.0

8.4

200

3.2

225

3.3

250

3.5

275

3.6

300

3.7

7.5

8.5

10

4.8

4.0

3.5

6.4

5.5

8.8

7.3
9.0

11

12

13

14

4.8

4.0

2.5

6.3

5.5

4.0

2.5

7.8

6.5

4.5

3.0

8.9

8.0

6.0

4.0

3.0

9.5

7.0

5.0

3.5

2.5

8.5

6.5

4.5

3.5

2.0

10

11

12

13

14

Unfactoredmaximumsuperimposedliveload(Qb)inkilopascals(kPa),(assumingnosuperimposeddeadloadie.SDL=0kPa).
100mmof25MPatoppingconcreteonroughsawn25mmthickpinusradiatatimberinfillsonribsspacedat900mmcentres.
Rib

Selfwt

depth(mm)

(kPa)

4.5

5.5

6.5

100

3.2

13.4

9.1

7.8

5.2

4.5

3.3

125

3.4

14.1

7.2

7.8

7.2

5.6

4.8

150

3.5

10.8

8.5

7.2

175

3.7

11.0

200

3.8

225

3.9

250

4.1

275

4.2

300

4.3

Simplysupportedspan(m)
7.5

8.5

6.2

5.2

4.6

8.3

7.2

6.2

5.2

3.2

11.4

9.5

9.5

7.2

5.2

3.2

11.7

10.1

8.5

5.9

3.9

11.6

10.4

7.8

5.2

3.9

12.4

9.1

6.5

4.6

3.3

11.1

8.5

5.9

4.6

NotesregardingLoad/Spantables:
1

Considerationneedstobegiventolongtermcreepeffectsduetohighersuperimposeddeadloads.ContactStahlton'stechnical
peopleforguidance.

TheLoadSpantablesassumeloadsareuniformlydistributed.Considerationisrequiredforshearactionsenducedfrompointloads.
Again,conctactStahlton'stechnicalpeopleforadvice.

Theoreticalcambershavebeenlimitedtospan/400.Considerhighercambersforsituationsclosetothetabulatedloadlimits.

RefertoStahlton'swebsitewww.stahlton.co.nzformoreinformation.

Ribsectionsdovaryslightlyinwidthanddepthdependingonfactorylocation.Refer"TypicalRib&InfillSection"forthisinformation.

Theactualprestressusedandthecapacityofthefloorvariesaccoordingtothedesignloadspecified.

Rib&InfillImportantInformation
EndSeatingStahltonRibflooringrequiresaminimum,andthegreaterof,75mmorL/180seatingontounarmouredconcretebeamorwall.
Aconstructiontoleranceofupto15mmneedstobecompensatedforaspercl.18.74NZS3101:Part1:2006.Stahltonandthecoderequirestheuseof
lowfrictionbearingstrips.
TemporaryproppingStahltonRibflooringdoesusuallyrequirepropping.Asaguidespans3to6mrequire1row,6to9m2rowsand
greaterthan9m3rowsofprops.Refertothesafeoperatingprocedureforproppingoftimberinfills.
CamberStahltonRibswillarriveonsitewithapositivecamberor"hog".Thisisunavoidableduetoprestressing.Hoggingwillvary
andbeinfluencedbytheamountofprestressrequiredtoresisttheinducedloads,lengthandageoftheunitsexposedtotheelements.
Handling&StorageStahltonRibsaredesignedtobeliftedusinghooksandchainstostrandliftingeyeslocatedatendsorlengthdividedby5
fromeachend.Ribsneedtobedunnagedascloseaspossibletotheliftinglocationandwithblocksinlinewiththeblockbelow,onsolidand
evenground.Ensureliftingequipmentisregularlychecked.
PenetrationsStahltonRib&Infillflooringdoesallowflexibilityforaccommodatingpenetrationsupto700mmwidethroughthetimbersection
andavoidingtheribs.Ifastrandiscutthroughribonsite,placeapropeithersideandcontactStahlton'sTechnicalDepartment
foradesignreview.AlsorefersectionXYforacceptabledetailsforattachingfixingstothesoffitoftheribs.

2.6

Stahlton Tech & Design Office


133 Waterloo Road, Hornby, Christchurch

ph 03 344 3014 Fax 03 344 3018

PO Box 8369 Riccarton, Christchurch 8440.

Web www.stahlton.co.nz

Rib&InfillSectionProperties
Sectionpropertiesarebasedon900mmribspacingwith25mmtimberplusa75mmconcretetopping.Compositesectionmodularratio=0.67.
BareUnit

Compositeunit

Rib

Unitwt

Overall

Yb

Zb

A'

Yb'

I'

Zb'

Zt'

depth(mm)

(kg/m)

depth(mm)

x103mm2

mm

x109mm4

x106mm3

x103mm2

mm

x109mm4

x106mm3

x106mm3

100

46

200

18

52

0.013

0.250

65

134

0.193

1.44

2.92

125

57

225

22

65

0.026

0.400

69

151

0.277

1.83

3.74

150

69

250

27

77

0.046

0.597

74

167

0.383

2.29

4.61

175

81

275

32

90

0.074

0.822

79

184

0.508

2.76

5.58

200

93

300

36

102

0.111

1.088

83

200

0.658

3.29

6.58

225

105

325

41

115

0.159

1.383

88

214

0.835

3.90

7.52

250

118

350

46

127

0.225

1.772

93

230

1.037

4.51

8.64

275

131

375

51

140

0.295

2.107

98

240

1.270

5.29

9.41

300

144

400

57

152

0.388

2.553

103

256

1.553

6.07

10.78

Thepropertiesabovewillprovideworstcaseofthe3ribsectionvariations..

TypicalRib&InfillSectionStahltonhave3subtlevariationstotheribsectionsnationally.
900 spacing
25 seating

25mm timber in-fill - refer to safe


operating procedure.

Topping
concrete

Overall
depth

Rib depth
100 - 300
Section variation,

Respective manufacturing plants:

150 at base,

Auckland & Balclutha

170 to base,

Christchurch & Cromwell

160 - 180 at top


185 - 215 at top

190 to base,

Bulls, New Plymouth & Mt Maunganui

195 - 205 at top

Rib&InfillAcousticRating
Rib

STC

depth(mm)

RwDnTw

Rw

STC

75mmtoppingconcrete

DnTw

plussuspendedceiling

TheacoustictableprovidesSTC(SoundTransmissionClass)ratings,
measuredindecibels.PredictedvaluescalculatedbyHegley

100

52

5355

55

54

56

AcousticConsultantsusingacomplexcrosssection.Benefitis

300

52

5456

60

60

62

gainedfromhavingasuspendedceilingof10mmGibraltorboard

Itisacceptabletolinearlyevaluateratingsbetweenribdepths.

suspendedbelowtheribsoffit.Anadditional8dBbenefitif
absorptionmaterialisusedbetweenribs.

Rib&InfillDurability
Stahlton'sRib&infillcomplieswithatbestexposureclassificationB2aspertable3.6inNZS3101:Part1:2006for50yearlife.

Rib&InfillThermalRating
Concrete

Timber

Normaldensity

Softwood

0.045

0.77

Rrating(m2oc/w)per100mmthickness
Theseareestimatedthermalresistanceratingsprovidedasaguideonly.

Rib&InfillFireResistanceRating
NewZealandStandardsrequireaminimumof95mmofconcretefor1.5hoursfirerating,110for2hoursand140mmfor3hours.Variationsare
permittedinthecaseofspecificproprietarysystemswhereacompletefloorisconstructedandthenfullyloadedandsubjectedtoafullscale
controlledfiretestcarriedoutbyanapprovedauthoritytoanacceptablestandard.StahltonRib&Infillsystemshavebeenextensivelytested
andwithinNewZealandbyBRANZandoverseasbytheCommonwealthBuildingStation(nowCSIRO).Onthebasisofthesetests,
StahltonRib&Infillfloorsqualifiedforafireratingof1.5hourswith75mmtoppingconcrete,2.0hourswith90mmtoppingand3.0hourswith
100mmoftoppingconcrete.In2010CSIROverifiedthatourtestingstillcomplieswiththelatestfiretestingstandards.Reportsareavailable
onrequest.

Das könnte Ihnen auch gefallen