Beruflich Dokumente
Kultur Dokumente
SETUPFORFAGORDNC50/55
SETUPFORDNC
(otherthanFagor)
8050T/TC/M/MC
8050T/TC/M/MC
P0=7(9600baudrate)
baudrate)
P1=1(8databits)
P2=0(noparity)
P3=0(1stopbit)
P4=1(dncprotocol)
P5=YES(dncactiveonpowerup)
P6=NO(debugfeaturenotactive)
P7=0(CANabortcharacter)
P8=0(LFendoflinecharacter)
P9=0(EOTendoffilecharacter)
P10=ON(XonXoff)
P0=..6,7,8..(4800,9600,etc
P1=0,1(8or7databits)
P2=0,1,2(no,odd,evenparity)
P3=0,1(1or2stopbits)
P4=0 (generaldevice)
P5=NO(fagordncnotactive)
P6,P7,P8,P9,P10arethesame
note: Thedebugfeaturecanbeactivatedonce
communicationisestablished
note:ALTPwillopenthemenuto
selectthemachinetypeandbaudrate
ALTLwillselectanothercomport
sendingandreceiving:Tosendaprogram,gotoutilities,copythe
programtoserialline2.Makesurethecomputeriswaitingto
receive.Toreceive,copyserialline2totheprogramnumber
SYMPTOM:
Afterconnectingthecnc,(computernumericalcontrol),toanotherexternaldevice
thereisnocommunication.
ANALYSIS:
Step1: Bothdevicesmustbecorrectlyconfigured.
1)
Makesurethatbothdevicesareon.
2)
CheckthelistofmachineparametersinthecncrelatedwiththeRS232.
Please
lookattheRS232parameterlistdependingonthecncmodel.
3)
Checktheconfigurationoftheperipheral.Makesurethatbothdeviceshave
the
same baudrate,numberofbits,stopbits,parity,etc.
4)
IfcommunicationisthroughDNC,(Fagorcommunicationsoftware),makesure
that:
a)
thecncmachineparametersareactivatedforDNC.
b)
theconfigurationinDNCissetupaccordingtothemachinetype.
c)
thecorrectseriallineisselectedintheDNCsoftware.
Iftheproblemstillpersist,
STEP2: Thecablemustbeproperlyconnected.
1)
Makesurethattheconnectorsarepluggedintheproperplaceinbothsides
2)
Checkthepinoutofthecable.RefertotheinstallationmanualabouttheRS
232configuration.
3)
Makesurethatthecableislessthan49ft.anditisnotrunthroughpowerlines
ortransformers.Thiscancauseinterferencewithcommunications.
STEP3: Detectwhichdeviceisdefective.
1)
Alwaystrytoreceiveatthecomputerfirst.
f:\msoffice\service\bible\rs232_50.doc
2)
SYMPTOM:
ANALYSIS:
character
not
know
SYMPTOM:
ANALYSIS:
com
SYMPTOM:
ANALYSIS:
SYMPTOM:
ANALYSIS:
SYMPTOM:
ANALYSIS:
Ifanotherperipheralorcncisavailable,trytoestablishcommunication.Ifthis
isnotpossible,acheckoutoftheequipmentwillbeneeded.
AnalysisforFagorDNC
Thecncdoesnotsaythattheprogramisreceived.
Ingeneral,itisduetotheENDOFFILEorENDOFTRANSMISSIONASCII
thattheperipheralhastosendinthepartprogram.Withoutitthecncdoes
whentostopsendingtheprogram.
Thesoftwaregivesanoreplywithintimelimit.
Makesurethatyouareusingtherightcomportinthesoftware.ALTLchangesthe
port.Checktheparametersandmakesurethecablefollowsourspecifications.
Inthepc,therearepartprogramsbuttheydonotappearonthescreen.
Makesureyouareinthecorrectdirectory.Alsocheckifthefileshavethecorrect
extensions.Formills,thepartprogrammustendwitha*.pimextensionandforlathes
mustendwitha*.pitextension.Theseextensionshelpthecncrecognizewhattypeof
partprogramyouhave.
Thereiscommunicationbetweentheperipheralandthecnc,butitisnotpossibleto
loadapartprogramtofromtoperipheralintothecnc.
Checkthatthefirstcharacterofthepartprogramhasa%symbolnexttothe
program numberfollowedby,MX,.
Whileloadingalongpartprogramfromaperipheralintothecnc,thecncwillgivea
syntaxerrormessage.
Inordertoknowexactlywhatthelineis,itisrecommendedtocuttheprogramintotwo
sectionsandtransmiteachsectionseparately.Repeatthisprocessuntiltheerroris
found.
SYMPTOM:
program
ANALYSIS:
Whentransmittingorreceivingalongprogram,(digitizing,tracingorinfinite
execution),sometimesthecommunicationisinterruptedwithanerror.
1)
Checktoseeifthedevicesaregroundedproperly.
2)
Electricalnoiseinthecableoritisgreaterthan49ft.Trywithashortercable
andmakesurethattheshieldisconnectedonthecncsideonly.
3)
Trywithalowerbaudrate.
Aboutthismatter,theRS232haslimitationsfromthelengthpointofview.
RS232PORT
SerialPortCableConnectionCNCPC
COM1orCOM2PORT
CNC9pin
f:\msoffice\service\bible\rs232_50.doc
PCComputer
25pin9pin