Quick Overview
Customer
Inverter
Problem
Owner: JPM
Name?
Customer type?
Installer
End-user
Sales customer
Type?
Serial number?
Check Navision
1000
274410789.xls
06/23/2015
Site Info
Which Country
How big is the site?
How many inverters are installed ?
How many inverters have failures ?
Software Version on the inverter ?
Is it a new installation or has the site been running for some time?
Has there been problems at the site in the past?
Display defect
Communication problem
New software
Wrong events in datalogger-> which one? Solarlog?? Customer must get the
newest firmware from Solare Datensysteme!
No communication with the datalogger?
274410789.xls
Onsite visit
Search
Search
Search
Search
Search
Search
Inverter smokes
Exchange
06/23/2015
Failure
Failure
Failure
Failure
Failure
Failure
OK
Exchange
1
2
3
OK
OK
OK
Individual
Asymmetrical layout:
Is the PV power entered into the
inverter?
Yes
No
Yes
OK
No
Yes
No
Onsite visit
yes
Yes
No
Yes
No
Max T
Max AC
Power Adj
Reac power
Freq stab
yes
NO
No
274410789.xls
Onsite visit
06/23/2015
Owner: JPM
OK
Then do it
Exchange
Check installation of the modules
OK
Install the PV bridge
274410789.xls
06/23/2015
Owner: JPM
yes
NO
Yes
No
Exchange
Onsite visit
No
Yes
yes
NO
Yes
No
Onsite visit
yes
No
yes
No
Exchange
Yes
Exchange
No
Onsite visit
Installer?
Yes
No
Onsite visit
Yes
Yes
No
Onsite visit
Yes
No
Fuses OK?
No
Yes
No
Yes
Yes
Onsite visit
No
No
274410789.xls
Yes
Exchange
No
Onsite visit
06/23/2015
Yes
No
OK
Change fuses
Yes
OK
No
Yes
OK
No
Is the production
time before week
360
Offgrid
Yes
Onsite visit
No
Yes
yes
Connecting
274410789.xls
Is the PV voltage
within the limits?
Is AC correctly installed?
Yes
No
Solved by
Hotline
Does it help?
No
No
Yes
No
Yes
Exchange
No
Yes
274410789.xls
06/23/2015
Owner: JPM
Exchange
274410789.xls
06/23/2015
274410789.xls
06/23/2015
Yes
No
yes
Low?
yes
no
Yes
PV OK?
Yes
No
max T
max AC
No
Onsite visit
Yes
OK
No
Yes
Onsite visit
No
Exchange
Yes
No
OK
Is the production time before week
360
Yes
No
Check logfiles/events
OK?
Failure?
OK
Depending on the failure code ?
Onsite visit
Exchange
274410789.xls
06/23/2015
Owner: JPM
OK
Check the Derate on the inverter
OK
Correct the installation
OK
Correct the installation
Check conditions inside /outside
Check grid (10 mins mean)
Onsite visit
Make a 24h pasw for changing
the country settings level 2
274410789.xls
Solved by
Hotline
06/23/2015
Fault Events
Event ID
0
Area
Description
Grid
UGRID - low L1 S2
2
3
Grid
Grid
UGRID - low L2 S2
UGRID - low L3 S2
Grid
UGRID - low L1 S1
Grid
6
7
Grid
Grid
UGRID - low L2 S1
UGRID - low L3 S1
274410789.xls
UGRID - mean L1
06/23/2015
Fault Events
Event ID
Area
Description
8
9
10
Grid
Grid
Grid
UGRID - mean L2
UGRID - mean L3
UGRID - high L1 S1
11
12
13
Grid
Grid
Grid
UGRID - high L2 S1
UGRID - high L3 S1
UGRID - high L1 S2
14
15
16
Grid
Grid
grid
UGRID - high L2 S2
UGRID - high L3 S2
UGRID - momentary L1
17
18
grid
Grid
UGRID - momentary L2
UGRID - momentary L3
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
19
Grid
FGRID - low L1
20
21
22
Grid
Grid
Grid
FGRID - low L2
FGRID - low L3
FGRID - high L1
23
24
Grid
Grid
FGRID - high L2
FGRID - high L3
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
25
Grid
LOM - 3 - L1
26
27
28
Grid
Grid
Grid
LOM - 3 - L2
LOM - 3 - L3
LOM - ROCOF - L1
29
30
31
Grid
Grid
Grid
LOM - ROCOF - L2
LOM - ROCOF - L3
IGRID - DC L1
32
33
Grid
Grid
IGRID - DC
IGRID - DC
274410789.xls
L2
L3
06/23/2015
Fault Events
Event ID
Area
Description
34
Grid
35
36
37
40
Grid
Grid
Grid
Grid
41
Grid
42
Grid
43
Grid
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
44
Grid
IgridDC detector L1
45
46
47
Grid
Grid
Grid
IgridDC detector L2
IgridDC detector L3
PLA - low
48
Grid
49
50
Grid
Grid
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
51
Grid
52
53
54
55
56
100
Grid
Grid
Grid
Grid
Grid
PV
101
102
PV
PV
IPV_NEGATIVE_PV2
IPV_NEGATIVE_PV3
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
103
PV
104
105
115
PV
PV
PV
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
116
PV
PV - wrong polarity
201
Internal
TEMP - power
202
Internal
TEMP - power
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
203
Internal
TEMP - power
204
Internal
TEMP - power
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
205
Internal
TEMP - PCB
The temperature inside the inverter is too high
206
Internal
TEMP - PCB
The temperature inside the inverter is too high
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
207
Internal
TEMP - PCB
The temperature inside the inverter is too high
208
Internal
TEMP - PCB
The temperature inside the inverter is too high
209
Internal
UDCbus - high
210
Internal
UDCbus - high
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
211
Internal
FAN_RPM_LOW
212
Internal
213
Internal
214
215
216
Internal
Internal
Internal
217
Internal
HW Trip L2
274410789.xls
HW Trip L1
06/23/2015
Fault Events
Event ID
Area
Description
218
222
Internal
Internal
HW Trip L3
Auto test
224
Internal
RCMU_OVERRANGE,
HW trip RCMU
225
Fail safe
Memory
226
Fail safe
Memory
227
Fail safe
Memory
228
Fail safe
Memory
229
Fail safe
Memory
230
Fail safe
Memory
231
Fail safe
Memory
232
Fail safe
Memory
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
233
Fail safe
Memory
234
Fail safe
Memory
235
Fail safe
Memory
236
Fail safe
Memory
237
Fail safe
Memory
238
Fail safe
Memory
239
Fail safe
Memory
240
Fail safe
Memory
241
Fail safe
COMM
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
242
Internal
COMM
243
Internal
244
Internal
245
246
Internal
Grid
Cover Open
A grid event was detected and inverter was stopped by
the redundant safety circuit
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
247
Internal
248
Fail safe
249
Internal
250
251
Internal
255
Internal
256
Internal
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
257
Internal
258
Internal
259
Fail safe
260
Fail safe
261
Fail safe
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
262
Fail safe
350
Fail safe
351
Fail safe
352
Fail safe
353
Fail safe
353-355 is pv side.
354
Fail safe
353-355 is pv side.
355
Fail safe
353-355 is pv side.
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
356
Fail safe
357
Fail safe
358
Fail safe
359
Fail safe
360
Fail safe
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
361
Fail safe
362
Fail safe
274410789.xls
06/23/2015
Fault Events
Event ID
Area
363
Fail safe
364
Fail safe
274410789.xls
Description
Transistor & Relay test failed.
06/23/2015
Fault Events
Event ID
Area
1000 Internal
274410789.xls
Description
Communication Board start up
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1,06
Grid1
Grid2
Grid3
See event 1
See event 1
Description: Grid voltage on phase 1 too low
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Voltage on phase1 not ok check all fuses and the RCD
o All ok 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
1,06
Grid4
Grid5
Grid6
see event 4
see event 4
End-user: Call installer
Installer: two options
Larger cable (diameter to ensure lower voltage drop) between inverter and meter
Program PF(P) TLX+ and PRO+ only
Call DNO to get permission to increase limit (note: Ugrid_RMS_high)
1,06
Grid7
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
Grid8
Grid9
see event 7
see event 7
Description: Grid voltage on phase 1 too high
Call installer and inform about the phase1 voltage.
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite help needed
Voltage on phase1 not ok onsite help needed call installer
Installer: Measure the actual grid voltage
Ok call Danfoss service partner
Not ok Call DNO to solve the problem
1,06
Grid10
Grid11
Grid12
see event 10
see event 10
Description: Grid voltage on phase 1 too high
Call installer and inform about the phase1 voltage.
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite help needed
Voltage on phase1 not ok onsite help needed call installer
1,06
Grid13
Grid14
Grid15
see event 13
see event 13
Description: Inverter has detected a voltage peak on the grid
End-user: Call DNO to solve the problem
1,06
see event 16
see event 16
274410789.xls
solarlog coder
06/23/2015
Grid16
Grid17
Grid18
Owner: TJA
Action / Description
SW
solarlog coder
1,06
Grid19
Grid20
Grid21
see event 19
see event 19
Description: the grid frequency is out of spectrum!
Call installer and inform about the phase1 freq.
End-user: check menu->status->phase1 freq.
Freq. on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Freq. on phase1 not ok check all fuses and the RCD
o All ok wait 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
1,06
Grid22
Grid23
Grid24
see event 22
see event 22
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1,06
Grid25
Grid26
Grid27
see event 25
see event 25
Description: Rate Of Change Of Frequency too high
End-user: If the event re-occurs (several times each day) contact DNO
1,06
Grid28
Grid29
Grid30
see event 28
see event 28
Description: DC grid current on phase 1 too high
1,06
274410789.xls
Grid31
Grid32
Grid33
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
Description: Residual Current Monitoring Unit (RCMU) has measured a too high current
End-user: Turn both DC and AC off and wait until the display turns off. Hereafter turn on DC and AC and
observe if the event re-occurs. If the event re-occur, call the installer.
Installer: Check the PV installation. If ok, exchange the inverter
see event 34
see event 34
see event 34
Description: AC Grid out of spec for more than 10 minutes (freq. and/or voltage)
1,06
1,06
1,06
1,06
Grid34
Grid35
Grid36
Grid37
End-user: Call installer and inform about the freq. and voltage, SW version and grid code settings
(country settings)
Installer: onsite
Check AC installation
1,06
Grid42
Description: Inverter has detected that grid voltage was below certain level
End-user: Call installer if the problems re-occurs (several times each day)
Installer: onsite - Perform grid analysis
Check if MV or LV ( Germany )setting, there is a failure in the LV Germany settings
Fix : New Grid code
1,10
2,10
Grid43
1,10
2,10
1,10
2,10
see event 41
see event 41
274410789.xls
06/23/2015
Grid44
Grid45
Owner: TJA
Action / Description
SW
solarlog coder
2,10
2,10
2,10
Grid46
Grid47
Grid48
2,10
Grid49
2,10
2,10
2,10
see event 48
see event 48
274410789.xls
06/23/2015
Grid50
Grid51
Grid52
Owner: TJA
Action / Description
SW
solarlog coder
2,10
2,10
2,10
2,10
see event 51
see event 51
Grid53
Grid54
Grid55
Grid56
Description: The input current on PV1 is negative the polarity of the PV string is wrong. Should only
appear during or immediately after installation or service.
End-user: call installer
Installer: Check PV installation
Is the polarity of the PV strings reversed (e.g. PV plus-wire connected with inverter minus-input) ->
Fix it!
Ok call Danfoss service partner
event 100
event 100
274410789.xls
06/23/2015
Grid57
Grid58
Grid59
Owner: TJA
Action / Description
SW
solarlog coder
1,06
PV107
PV108
PV109
event 103
event 103
Potential HW BUG: Go through the PV installation and check connectors, cables and modules for
insulation-failure. When Event 115 is Pressent
IF no Error then Exchange Inverter with Special handling
----------------------------------------------------------------------------Description: The resistance between the PV strings and ground is too low for the inverter to start-up.
End-user: Check [status->photovoltaic->isolation resistance] and call installer
Installer: Check minimum recorded isolation resistance [status->photovoltaic->isolation resistance, level
1]
Go through the PV installation and check connectors, cables and modules for insulation-failure.
1,06
If the failure is present while on-site, disconnect PV input 1 and restart the inverter to locate the
affected PV string. Continue with strings 2 and 3. See section in reference manual and copy it to this
document.
The isolation resistor between ground and PV is too low. After 10 minutes it will try again! Check if PE is
installed correct! Perhaps the modules or pv cables are wet?
PV122
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
2.10
check PV polarity
- Active in SW 2,10
Description: Internal temperature too high
PV123
1,06
Fail114
274410789.xls
06/23/2015
Fail225
Owner: TJA
Action / Description
Over (S1) For occurrence > 100 C
SW
solarlog coder
Fail226
274410789.xls
06/23/2015
Fail227
Owner: TJA
Action / Description
SW
solarlog coder
1,06
Fail228
274410789.xls
06/23/2015
Fail229
Owner: TJA
Action / Description
SW
solarlog coder
Fail230
274410789.xls
06/23/2015
Fail231
Fail232
Fail233
Owner: TJA
Action / Description
SW
solarlog coder
1,06
No Tacko signal from fan check the fans! Perhaps defect fan. Check the event-log
Check the surroundings IF ok and only 1inverter Exchange else Onsite
Fail234
The failure comes when unit is off grid and there it out of balance between the capacitors. shut down AC
& DC, wait 5-10 minutes and start again.
if the failure comes again, then exchange
solve for New production - week 48-2011
Gate driver problem can be seen in Refurbish Inverter After Week 48-2011
It seems that the error 212(trafo and Gate driver problem ) can trigger the event 241
1,06
Fail235
Description: Internal error. Voltage measured before and after the relay differs with more than 20V
End-user: Call installer
Installer: Call Danfoss Service Partner
Plausibility error between internal measurements
difference, then change inverter
1,06
Fail236
Fail237
Fail238
1,06
The grid current is too high For occurrence i| > 60 A For clearance |i| < 60 A
Fail239
Fail240
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
Fail241
1,06
Fail248
1,06
Fail350
1,06
Fail351
Fail352
Fail353
274410789.xls
Fail354
1,06
Fail355
Fail356
Fail357
Fail358
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1,06
Fail359
RAM - Comm
see event 233
RAM - FSP
see event 233
Does not exist!
RAM - xxx
RAM - CTRL
see event 233
RAM - Comm
see event 233
RAM - FSP
see event 233
Does not exist!
RAM - xxx
Description: No contact to sensor
Fail360
Fail361
Fail362
1,06
Fail363
Fail364
Fail365
Fail366
1,06
274410789.xls
06/23/2015
Fail367
Owner: TJA
Action / Description
SW
solarlog coder
Description: Communication between control board and control board failed for more than 10 sec.
End-user: Restart the inverter. If error persists call installer
Installer: Replace inverter
1,06
Fail368
1,06
Fail369
Fail370
Cannot be displayed after SW version 2.01 (new comm. Boards introduced week 37, 2010)
Description: Functional Safety processor detected grid event
End-user: Check event log for other grid events (1-55) and follow the instructions for these events. If
the error persist call installer
1,06
274410789.xls
06/23/2015
Fail372
Owner: TJA
Action / Description
SW
solarlog coder
1,06
Fail373
1,06
Fail375
1,06
Fail377
End-user: Check event log for other grid events (1-55) and follow the instructions for these events. If
the error persist call installer.
1,09
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1,09 /
2,01
2,10
- Active in SW 2,10
Description: Unable to change the voltage between ground and neutral during isolation test (by less
than 10 V)
End-user: Call Danfoss Service
Installer: Check the PV installation for isolation error. If ok, exchange the inverter.
2,10
- Active in SW 2,10
2,10
- Active in SW 2,10
Exchange
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
2,10
- Active in SW 2,10
1,06
Exchange inverter
For occurrence - mean above 25 mA (Value from plausibility test table)?
a. Yes Go to fail safe and report Fail Safe (after three retries).
For clearance
- Reset - if not Exchange inverter
Description: RCMU cannot detect step (of 25 mA) in residual current
End-user: Call Danfoss Service/installer
Installer: Exchange the inverter.
1,06
1,06
1,06
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1.04
Description: Inverter relay has failed (assumed welded)
End-user: Call Danfoss Service
Installer: Exchange the inverter
1.04
1.04
1.04
274410789.xls
1.04
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1.04
105
1.04
106
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
1.04
107
1.04
108
274410789.xls
06/23/2015
Owner: TJA
Action / Description
SW
solarlog coder
When AC and DC was shot off and power is back on the inverter the event 1000 is giving the
notice that the COMBO is start up
Capa case number 138048
It seems that the error 242 and 1000 is the ( AC Standby problem )
event is seen after Sundown on the inverter - Exchange inverter
NEW
- Ask the customer what kind of RCMU (FI/HPFI) that is used, and write it into the RMA case.
E.g.: MOELLER FI-Schutzschalter PXF 63/4/03-A
- If the FI/HPFI is the pulse sensitive type, change it to a, none sensitive type.
Exchange of the inverter will NOT solve the FI/HPFI problem!
2.10
274410789.xls
06/23/2015
Fault Events
Event ID
0
GSM
Yes
LAN
Yes
Owner: TJA
Name
eNomemory
Yes
No
No
No
Description / Action
eok
No Error
Dynamic memory Allocation Failed
End-user: Power cycle inverter
Installer: call Danfoss After Sales Service
Service provide: call Danfoss After Sales Service
Danfoss: report bug
Not used
eModembufferinoverflow
Not used
Incomming data buffer overflowed (modem response to long)
Yes
No
emodemCmdReplyerror
4
Yes
No
emodenCmdTimeout
Yes
No
No
No
274410789.xls
Not used
Not used
06/23/2015
Fault Events
Event ID
GSM
LAN
Owner: TJA
Name
emodeminitfail
Yes
Yes
Not used
eUnexpectedState
No
10
eModemReplyParseFailed
Yes
eConnectionUnavailable
Yes
274410789.xls
No
Not used
Internal fault, Unexpected state
End-user: Power cycle inverter
Installer: call Danfoss After Sales Service
Service provide: call Danfoss After Sales Service
Danfoss: report bug
Modem response not recognized
End-user: Power cycle inverter
Installer: call Danfoss After Sales Service
Service provide: call Danfoss After Sales Service
Danfoss: report bug
No
11
No
No
8
9
Description / Action
Upload failed, not logged into home nor roaming (if allowed) GSM network
End-user:
Only take action if event re-occurs!
Check GSM signal strength (if not ok, try different provider)
Check if the SIM cards works (in a mobile phone)
Call installer
Installer: Install router with build-in GSM modem and place it for better
reception
06/23/2015
Fault Events
Event ID
GSM
LAN
12
Owner: TJA
Name
Description / Action
eModemLinkOpenFail
Failed to open upload connection (generic)
Something other than GPRS or FTP failed
Only take action if event re-occurs!
Yes
13
14
15
16
17
End-user:
Check GSM signal strength (if not ok, try different provider)
Check if the SIM cards works (in a mobile phone)
Meteocontrol: file a bug
Other FTP server: Try to configure another/different FTP-server
Installer: Call Danfoss after sales Service
Danfoss: Report bug
No
eModemLinkCloseFail
Yes
No
No
No
Yes
No
No
No
Yes
Not used
Not used
Not used
eUploadFileSize
eModemNoNetwork
Yes
274410789.xls
No
Not used
Not used
Not used
Uploaded file size check did not match. Part of the file was probably lost.
End-user: call installer
Installer: change FTP server configuration (spec. defining supported FTP
config. Needed)
18
Failed to close connection (FTP or GPRS) after upload. Not critical, data was
sent OK.
End-user: Not a serious event, if it reoccurs Inform your Installer
Installer: call Danfoss After Sales Service
Danfoss: report bug
06/23/2015
Fault Events
Event ID
19
GSM
Yes
LAN
No
20
eModemParseMfgr
Yes
No
Yes
No
Yes
No
Yes
No
No
No
Yes
No
eModemParseModel
eModemParseRvsn
24
25
26
274410789.xls
Description / Action
Check if the SIM cards works (in a mobile phone)
Installer: replace modem
Upload file exists on server (with exactly the same serial and timestamp in
name). DWH refuses to overwrite existing log files on server.
Avoid uploading to the same FTP server from different sites
Installer: change FTP server configuration (spec. defining supported FTP
config. Needed)
Call Danfoss ASS
Danfoss: report bug
No
21
23
Name
eModemSIMResponse
eUploadFileExists
Yes
22
Owner: TJA
eModemParseRSSI
Not used
eModemSecurityNotPIN
06/23/2015
Fault Events
Event ID
GSM
LAN
Owner: TJA
Name
27
Yes
Description / Action
Failed to parse response to pin status query
End-user: Power cycle inverter
Installer: replace modem. If that does not help then call Danfoss After
Sales Service
Service provide: call Danfoss After Sales Service
Danfoss: report bug
No
eModemParsePINStatus
28
Yes
No
eModemParseNetRegStat
Internal fault, unexpected MCH initialization state
Call Danfoss
Danfoss: report bug
29
Yes
No
eUnexpectedInitState
30
No
eModemSetPIN
31
32
Yes
No
Yes
No
274410789.xls
eGPRSParams
Not used
06/23/2015
Fault Events
Event ID
33
34
GSM
LAN
Yes
No
Yes
No
Owner: TJA
Name
eGPRSAuthUser
eGPRSAuthPasswd
Description / Action
Failed to set GPRS user name
End-user: User name is not sane. Avoid whitespace.
Failed to set GPRS password
End-user: Password is not sane. Avoid whitespace.
35
No
eGPRSOpen
36
Yes
End-user:
Many things can cause GPRS connection to fail. The APN, user name
or password might be wrong, ask GSM provider for GPRS
configuration. Maybe GPRS is not enabled for your SIM?
Yes
eFTPOpen
37
Yes
No
eFTPTransferType
38
Yes
No
eFTPChdir
274410789.xls
06/23/2015
Fault Events
Event ID
GSM
LAN
Owner: TJA
Name
Description / Action
39
Yes
eFTPPut
40
Yes
No
eUploadFileRead
There is no data log to upload.
All unsent log has been sent and inverter has not yet generated any
new log.
This is not an error. It just indicates that all log that needs uploading
has already been uploaded.
41
Yes
No
eNoData
The master inverters RTC is not set. Inverters time must be set for
uploads to occur.
End-user: call installer
Installer: set clock
42
Yes
Yes
eTimeNotSet
43
Yes
Yes
eInvalidSerial
274410789.xls
06/23/2015
Fault Events
Event ID
GSM
LAN
Owner: TJA
Name
Description / Action
The SIM PIN code is not valid.
End-user: A PIN code must be 4-8 characters long and consist only of
digits. No other characters are permitted.
Failed to open FTP file for uploading
End-user:call installer
Installer: Installer: change FTP server configuration (spec. defining
supported FTP config. Needed)
44
Yes
No
NO
No
eInvalidPIN
45
eModemFileOpenFail
46
No
No
eModemSendSMSFail
47
No
No
NO
NO
NO
NO
NO
NO
48
49
50
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
Grid
UGRID - low L1 S2
2
3
Grid
Grid
UGRID - low L2 S2
UGRID - low L3 S2
Grid
='Fault Events'!C8
Grid
UGRID - low L2 S1
6
7
Grid
Grid
UGRID - low L3 S1
Grid
UGRID - mean L2
274410789.xls
UGRID - mean L1
06/23/2015
Fault Events
Event ID
Area
Description
Grid
UGRID - mean L3
10
Grid
UGRID - high L1 S1
11
12
Grid
Grid
UGRID - high L2 S1
UGRID - high L3 S1
13
Grid
UGRID - high L1 S2
14
Grid
UGRID - high L2 S2
15
Grid
UGRID - high L3 S2
16
grid
UGRID - momentary L1
17
grid
UGRID - momentary L2
18
Grid
UGRID - momentary L3
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
19
Grid
FGRID - low L1
20
Grid
FGRID - low L2
21
Grid
FGRID - low L3
22
Grid
FGRID - high L1
23
Grid
FGRID - high L2
24
Grid
FGRID - high L3
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
25
Grid
LOM - 3 - L1
26
Grid
LOM - 3 - L2
27
Grid
LOM - 3 - L3
28
Grid
LOM - ROCOF - L1
29
Grid
LOM - ROCOF - L2
30
Grid
LOM - ROCOF - L3
31
Grid
IGRID - DC
L1
32
Grid
IGRID - DC
L2
33
Grid
IGRID - DC
L3
34
Grid
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
35
Grid
36
Grid
37
Grid
38
Grid
Insulation test
39
Grid
40
Grid
41
Grid
42
Grid
43
Grid
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
44
Grid
IgridDC detector L1
45
Grid
IgridDC detector L2
46
Grid
IgridDC detector L3
48
Grid
49
Grid
50
Grid
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
51
Grid
52
Grid
53
Grid
54
55
56
223
Grid
Grid
Grid
Grid
DC component L1 - stage 2
DC component L2 - stage 2
DC component L2 - stage 2
IgridHigh
246
Grid
06/23/2015
Owner: TJA
Action
Description: Grid voltage on phase 1 too low
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Voltage on phase1 not ok check all fuses and the RCD
o All ok 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
Ok call Danfoss service partner
Not ok Fix it
See event 1
See event 1
Description: Grid voltage on phase 1 too low
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Voltage on phase1 not ok check all fuses and the RCD
o All ok 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
Ok call Danfoss service partner
Not ok Fix it
see event 4
see event 4
End-user: Call installer
Installer: two options
Larger cable (diameter to ensure lower voltage drop) between inverter and meter
Program PF(P) TLX+ and PRO+ only
Call DNO to get permission to increase limit (note: Ugrid_RMS_high)
see event 7
274410789.xls
06/23/2015
Owner: TJA
Action
see event 7
Description: Grid voltage on phase 1 too high
Call installer and inform about the phase1 voltage.
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite help needed
Voltage on phase1 not ok onsite help needed call installer
Installer: Measure the actual grid voltage
Ok call Danfoss service partner
Not ok Call DNO to solve the problem
see event 10
see event 10
Description: Grid voltage on phase 1 too high
Call installer and inform about the phase1 voltage.
End-user: check menu->status->phase1 voltage.
Voltage on phase1 is ok wait 10 minutes. Does it reconnect? Onsite help needed
Voltage on phase1 not ok onsite help needed call installer
Installer: Measure the actual grid voltage
Ok call Danfoss service partner
see event 13
see event 13
Description: Inverter has detected a voltage peak on the grid
End-user: Call DNO to solve the problem
see event 16
see event 16
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Grid freq. on phase 1 too low
Call installer and inform about the phase1 freq.
End-user: check menu->status->phase1 freq.
Freq. on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Freq. on phase1 not ok check all fuses and the RCD
o All ok wait 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
Ok call Danfoss service partner
Not ok Fix it
see event 19
see event 19
Description: the grid frequency is out of spectrum!
Call installer and inform about the phase1 freq.
End-user: check menu->status->phase1 freq.
Freq. on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Freq. on phase1 not ok check all fuses and the RCD
o All ok wait 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
If SW is below 2,10 - update SW call Danfoss service partner
Ok call Danfoss service partner
Not ok Fix it Grid must be checked
see event 22
see event 22
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Phase-to-Phase voltage on phase L1-L2 too low
Call installer and inform about all three phase voltages.
End-user: check menu->status->phase1 voltage.
Voltage on all three phases is ok wait 10 minutes. Does it reconnect? Onsite service needed
Voltage on all three phases is not ok check all fuses and the RCD
o All ok 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
Ok call Danfoss service partner
Not ok Fix it
see event 25
see event 25
Description: Rate Of Change Of Frequency too high
see event 28
End-user: If the event re-occurs (several times each day) contact DNO
see event 28
Description:
DC grid
current on phase 1 too high
Installer: Check
SW version
update to SW 1,12 / 2,15 call Danfoss service partner
End-user: Check SW version Status->blabla
If lower than 2.15 or 1.12 a SW update is required. Call Service
If 3.00 : update to SW 3.10
see event 31
see event 31
Description: Residual Current Monitoring Unit (RCMU) has measured a too high current
End-user: Turn both DC and AC off and wait until the display turns off. Hereafter turn on DC and AC and
observe if the event re-occurs. If the event re-occur, call the installer.
Installer: Check the PV installation. If ok, exchange the inverter
274410789.xls
06/23/2015
Owner: TJA
Action
see event 34
see event 34
see event 34
Does not exist anymore.
Insulation
impedance
- underInvestigate!
.Does
not exist
anymore????
Description: AC Grid out of spec for more than 10 minutes (freq. and/or voltage)
End-user: Call installer and inform about the freq. and voltage, SW version and grid code settings
(country settings)
Installer: onsite
Check AC installation
If SW version is below 2.15 an update is needed.
Check the log for other events
Description: Inverter has detected that grid voltage was below certain level
End-user: Call installer if the problems re-occurs (several times each day)
Installer: onsite - Perform grid analysis
Check if MV or LV ( Germany )setting, there is a failure in the LV Germany settings
Fix : New Grid code
see event 41
see event 41
274410789.xls
06/23/2015
Owner: TJA
Action
Description: DC grid current on phase 1 too high
End-user: Check SW version Status->blabla
If lower than 2.15 or 1.12 a SW update is required. Call Service
If 2.15 or higher: ??? currently no solution!
Active in SW 1,10 - 2,10
see event 44
see event 44
Description: Grid freq. on phase 1 too low
Call installer and inform about the phase1 freq.
End-user: check menu->status->phase1 freq.
Freq. on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Freq. on phase1 not ok check all fuses and the RCD
o All ok wait 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
Ok call Danfoss service partner
Not ok Fix it
Active in SW 2,10
see event 48
see event 48
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Grid freq. on phase 1 too High
Call installer and inform about the phase1 freq.
End-user: check menu->status->phase1 freq.
Freq. on phase1 is ok wait 10 minutes. Does it reconnect? Onsite service needed
Freq. on phase1 not ok check all fuses and the RCD
o All ok wait 10 minutes. Does it reconnect? Onsite service needed
o Not ok - Onsite service needed
Installer: Check AC installation
Ok call Danfoss service partner
Not ok Fix it
Active in SW 2,10
see event 51
see event 51
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
IPV_NEGATIVE_PV1
100
PV
101
102
PV
PV
IPV_NEGATIVE_PV2
IPV_NEGATIVE_PV3
103
PV
104
105
PV
PV
106
PV
EPV - diff
107
PV
EPV - diff
108
PV
EPV - diff
109
PV
EPV - low
110
PV
EPV - low
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
111
PV
EPV - low
115
PV
PV_ISO_TOO_LOW
116
PV
PV - wrong polarity
274410789.xls
06/23/2015
Owner: TJA
Action
Description: The input current on PV1 is negative the polarity of the PV string is wrong.
Should only appear during or immediately after installation or service.
End-user: call installer
Installer: Check PV installation
Is the polarity of the PV strings reversed (e.g. PV plus-wire connected with inverter minusinput) -> Fix it!
Ok call Danfoss service partner
event 100
event 100
IPV PV current is too high > 13,5 A - reset = IPV < 1A
Description: The input current on PV1 is too high Too many PV modules connected in parallel. Should
only appear on newly installed systems.
End-user: call installer
Installer: Check PV installation
how many strings are in parallel? What are their current ratings?
Have the inverter derated on PV current [log->derate, level 1]
If too many strings are in parallel, the fix it by:
1) Connect the inverter inputs in parallel to distribute the current into the inverter
2) Install a second inverter
Check the PV layout
event 103
event 103
Does not exist??
Does not exist??
Difference > 10% - CLEARANCE = Difference <10%
Does not exist??
Difference > 10% - CLEARANCE = Difference <10%
Does not exist??
Difference > 10% - CLEARANCE = Difference <10%
Does not exist??
< 1.5 kWh / input / day
< 1.5 kWh / input / day
274410789.xls
06/23/2015
Owner: TJA
Action
Does not exist??
Potential HW BUG: Go through the PV installation and check connectors, cables and modules for
<
1.5 kWh / input When
/ day Event 115 is Pressent
insulation-failure.
IF no Error then Exchange Inverter with Special handling
----------------------------------------------------------------------------Description: The resistance between the PV strings and ground is too low for the inverter to start-up.
End-user: Check [status->photovoltaic->isolation resistance] and call installer
Installer: Check minimum recorded isolation resistance [status->photovoltaic->isolation resistance, level
1]
Go through the PV installation and check connectors, cables and modules for insulation-failure.
If the failure is present while on-site, disconnect PV input 1 and restart the inverter to locate the
affected PV string. Continue with strings 2 and 3. See section in reference manual and copy it to this
document.
The isolation resistor between ground and PV is too low. After 10 minutes it will try again! Check if PE is
installed correct! Perhaps the modules or pv cables are wet?
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
201
Internal
TEMP - power
202
Internal
TEMP - power
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
203
Internal
TEMP - power
204
Internal
TEMP - power
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
205
Internal
TEMP - PCB
The temperature inside the inverter is too high
206
Internal
TEMP - PCB
The temperature inside the inverter is too high
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
207
Internal
TEMP - PCB
The temperature inside the inverter is too high
208
Internal
TEMP - PCB
The temperature inside the inverter is too high
209
Internal
UDCbus - high
210
Internal
UDCbus - high
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
211
Internal
FAN_RPM_LOW
212
Internal
213
214
215
Internal
216
Internal
HW Trip L1
217
218
219
Internal
Internal
Internal
HW Trip L2
HW Trip L3
IPV HW trip 1
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
220
Internal
221
Internal
222
Internal
Auto test
224
Internal
RCMU_OVERRANGE,
HW trip RCMU
242
Internal
COMM
274410789.xls
IPV
HW trip 2
IPV HW trip 3
06/23/2015
Fault Events
Event ID
Area
Description
243
Internal
244
Internal
246
Internal
247
Internal
249
Internal
251
Internal
255
Internal
256
Internal
257
Internal
274410789.xls
06/23/2015
Fault Events
Event ID
258
Area
Internal
Description
UDCbus - overvoltage
259
260
261
262
274410789.xls
06/23/2015
Fault Events
Event ID
Area
1000 Internal
Description
Communication Board start up
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Internal temperature too high
Is the inverter covered or is the ventilation duct (heat sink) blocked?
Call installer for service.
Installer: Has the inverter derated on temperature [log->derate, level 1], have the inverter reported
event 211 (fan)
NO call Danfoss service partner
Yes, clean heat sink / remove obstruction / see description for event 211
Check the airflow How are the conditions?? is the inverter mounted in the sun or something like that?
check if more events came! if all ok, then it could be the temp sensor (exchange)
Over (S1) For occurrence > 100 C For clearance < 90C
Description: Internal temperature too high
How to identify root cause
Is the inverter covered or is the ventilation duct (heat sink) blocked?
Call installer for service.
Installer: Has the inverter derated on temperature [log->derate, level 1], have the inverter reported
event 211 (fan)
NO call Danfoss service partner
Yes, clean heat sink / remove obstruction / see description for event 211
Check the airflow How are the conditions?? is the inverter mounted in the sun or something like that?
check if more events came! if all ok, then it could be the temp sensor (exchange)
Over (S1) For occurrence > 100 C For clearance < 90C
274410789.xls
06/23/2015
Owner: TJA
Action
Over (S1) For occurrence > 100 C
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Internal temperature too high
Is the inverter covered or is the ventilation duct (heat sink) blocked?
Call installer for service.
Installer: Has the inverter derated on temperature [log->derate, level 1], have the inverter reported
event 211 (fan)
NO call Danfoss service partner
Yes, clean heat sink / remove obstruction / see description for event 211
Check the airflow How are the conditions?? is the inverter mounted in the sun or something like that?
check if more events came! if all ok, then it could be the temp sensor (exchange)
Over (S1) For occurrence > 100 C For clearance < 90C
Description: Internal temperature too high
Is the inverter covered or is the ventilation duct (heat sink) blocked?
Call installer for service.
Installer: Has the inverter derated on temperature [log->derate, level 1], have the inverter reported
event 211 (fan)
NO call Danfoss service partner
Yes, clean heat sink / remove obstruction / see description for event 211
Check the airflow How are the conditions?? is the inverter mounted in the sun or something like that?
check if more events came! if all ok, then it could be the temp sensor (exchange)
Over (S1) For occurrence > 85 C For clearance < 75C
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Internal temperature too high
Is the inverter covered or is the ventilation duct (heat sink) blocked?
Call installer for service.
Installer: Has the inverter derated on temperature [log->derate, level 1], have the inverter reported
event 211 (fan)
NO call Danfoss service partner
Yes, clean heat sink / remove obstruction / see description for event 211
Check the airflow How are the conditions?? is the inverter mounted in the sun or something like that?
check if more events came! if all ok, then it could be the temp sensor (exchange)
Over (S1) For occurrence > 85 C For clearance < 75C
Description: Internal temperature too high
Is the inverter covered or is the ventilation duct (heat sink) blocked?
Call installer for service.
Installer: Has the inverter derated on temperature [log->derate, level 1], have the inverter reported
event 211 (fan)
NO call Danfoss service partner
Yes, clean heat sink / remove obstruction / see description for event 211
Check the airflow How are the conditions?? is the inverter mounted in the sun or something like that?
check if more events came! if all ok, then it could be the temp sensor (exchange)
Over (S1) For occurrence > 85 C For clearance < 75C
check in Display the pv voltage (if it is over the maximum) could also be to high voltage on the AC side.
Voltage is out of specs.
For occurrence > 435
For clearance < 435
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Fan speed too low
End-user: Is the inverter fan blocked?
If yes unblock
If no - Call installer for service.
No Tacko signal from fan check the fans! Perhaps defect fan. Check the event-log
Check the surroundings IF ok and only 1inverter Exchange else Onsite
The failure comes when unit is off grid and there it out of balance between the capacitors. shut down AC
& DC, wait 5-10 minutes and start again.
if the failure comes again, then exchange
solve for New production - week 48-2011
Gate driver problem can be seen in Refurbish Inverter After Week 48-2011
It seems that the error 212(trafo and Gate driver problem ) can trigger the event 241
274410789.xls
06/23/2015
Owner: TJA
Action
Defined, but cannot be displayed
For occurrence -5 A < i > 15 A
For clearance -5 A > i < 15 A
Does not exist??
check the SW version. SW 1.09 should help for this problem. its cause of bad grid! if the inverter shows
other failures afterwards (self test failures) change the inverter
For occurrence -5 A < i > 15 A
For clearance -5 A > i < 15 A
Italy - Auto test
Someone commanded an Auto test. No action required
Description: Defect RCMU circuit, should also include events 350-352 from self-test (fail safe)
End-user: Call installer
Installer: Call Service partner to have the inverter replaced.
Value or broken wire in the RCMU - reset inverter or change inverter
For occurrence Value or broken wire
For clearance reset
Description: Communication between control board and control board failed for more than 10 sec.
End-user: Restart the inverter. If error persists call installer
Installer: Replace inverter
NO Communication - reset inverter - change inverter
Capa case number 138048
It seems that the error 242 and 1000 is the ( AC Standby problem )
event is seen after Sundown on the inverter - Exchange inverter
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Internal communication error
End-user: Restart the inverter. If error persists call installer
Installer: Replace inverter
274410789.xls
06/23/2015
Owner: TJA
Action
Description: DC bus overvoltage
End-user: If problem persists call installer.
Installer: Check PV installation/layout.
DC-bus capacitors exceeds the maximum limit for the inverter. The inverter continues normal operation
when the voltage level is lowered to a level within limits
For occurrence > 1010
For clearance < 1008
274410789.xls
06/23/2015
Owner: TJA
Action
When AC and DC was shot off and power is back on the inverter the event 1000 is giving the
notice that the COMBO is start up
Capa case number 138048
It seems that the error 242 and 1000 is the ( AC Standby problem )
event is seen after Sundown on the inverter - Exchange inverter
NEW
- Ask the customer what kind of RCMU (FI/HPFI) that is used, and write it into the RMA case.
E.g.: MOELLER FI-Schutzschalter PXF 63/4/03-A
- If the FI/HPFI is the pulse sensitive type, change it to a, none sensitive type.
Exchange of the inverter will NOT solve the FI/HPFI problem!
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
300
de-rate
Igrid L1
301
de-rate
Igrid L2
302
de-rate
Igrid L3
303
de-rate
Pgrid L1
304
de-rate
Pgrid L2
305
de-rate
Pgrid L3
306
de-rate
Ugrid L1
307
de-rate
Ugrid L2
308
de-rate
Ugrid L3
309
de-rate
IPV 1
310
de-rate
IPV 2
311
de-rate
IPV 3
312
de-rate
PPV 1
313
de-rate
PPV 2
314
de-rate
PPV 3
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
315
de-rate
Tpower
316
de-rate
Tpower
317
De-rate
Tpower
318
de-rate
Tpower
319
de-rate
TPCB
320
de-rate
TPCB
321
de-rate
TPCB
322
de-rate
TPCB
274410789.xls
06/23/2015
Owner: TJA
Action
Cannot be displayed???
Derate - Igrid L1
For occurrence >22A
For clearance ? <22A
Cannot be displayed???
Cannot be displayed???
Derate - Igrid L2
Cannot
be displayed???
For
occurrence
>22A
Derate
- Igrid L3
For
clearance
?
<22A
For
occurrence
Derate
Pgrid L1>22A
For
<22A
For clearance
occurrence? >
5000W
For clearance < 5000W
Cannot be displayed???
Cannot be displayed???
Derate Pgrid L2
Cannot
be displayed???
For
occurrence
Derate
Pgrid L3> 5000W
For occurrence
clearance < 5000W
For
5000W
For occurrence >
Variable
For
clearance
<
5000W
For clearance Variable
Cannot be displayed???
Cannot be displayed???
For occurrence Variable
Cannot
be displayed???
For
For clearance
occurrenceVariable
Variable
For
clearance
Derate
IPV 1 Variable
For occurrence > 12A
For clearance < 12A
Cannot be displayed???
Cannot be displayed???
Derate IPV 2
Cannot
be displayed???
For
occurrence
Derate
IPV 3 > 12A
For
clearance
< 12A
For
occurrence
Derate
PPV 1 > 12A
For
For clearance
occurrence<>12A
6000W
For clearance < 6000W
Cannot be displayed???
Cannot be displayed???
Derate PPV 1
For
occurrence
Derate
PPV 1 > 6000W
For occurrence
clearance <>6000W
For
6000W
For clearance < 6000W
274410789.xls
06/23/2015
Owner: TJA
Action
Cannot be displayed???
Derate - Tpower
For occurrence > 85 C
For clearance < 85 C
Cannot be displayed???
Cannot be displayed???
Derate - Tpower
For
occurrence
> 85 C
Derate
- Tpower
For
clearance
<
For occurrence >85
85C
C
For clearance < 85 C
Cannot be displayed???
Derate - Tpower
For occurrence > 85 C
For clearance < 85 C
Cannot be displayed???
Derate TPCB
For occurrence > 75 C
For clearance < 75 C
Cannot be displayed???
Derate TPCB
For occurrence > 75 C
For clearance < 75 C
Cannot be displayed???
Derate TPCB
For occurrence > 75 C
For clearance < 75 C
Cannot be displayed???
Derate TPCB
For occurrence > 75 C
For clearance < 75 C
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
225
Fail safe
Memory
226
Fail safe
Memory
227
Fail safe
Memory
228
Fail safe
Memory
229
Fail safe
Memory
230
Fail safe
Memory
231
Fail safe
Memory
232
Fail safe
Memory
233
234
Fail safe
Fail safe
Memory
Memory
235
Fail safe
Memory
236
Fail safe
Memory
237
Fail safe
Memory
238
Fail safe
Memory
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
239
Fail safe
Memory
240
Fail safe
Memory
241
Fail safe
COMM
259
Fail safe
260
Fail safe
261
Fail safe
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
262
Fail safe
350
Fail safe
351
Fail safe
352
Fail safe
353
Fail safe
353-355 is pv side.
354
Fail safe
353-355 is pv side.
355
Fail safe
353-355 is pv side.
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
356
Fail safe
357
Fail safe
358
Fail safe
359
Fail safe
360
Fail safe
274410789.xls
06/23/2015
Fault Events
Event ID
Area
Description
361
Fail safe
362
Fail safe
274410789.xls
06/23/2015
Fault Events
Event ID
Area
363
Fail safe
364
Fail safe
274410789.xls
Description
Transistor & Relay test failed.
06/23/2015
Fault Events
Event ID
Area
Description
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Failure in Memory/Eeprom control board
End-user: Call installer
Installer: Replace inverter
Description: Failure in Memory/Eeprom comm board
End-user: Call installer
Installer: Replace inverter
Description: Failure in Memory/Eeprom Aux board
End-user: Call installer
Installer: Replace inverter
EEPROM - Power
See event 227
Flash - CTRL
See event 227
Flash - Comm
See event 227
Flash - FSP
See event 227
Does not exist!
Flash - xxx
Description: Memory check failed - control board
End-user:
Restart the inverter. If error persists call installer
RAM
- Comm
Installer:
inverter
see
event Replace
233
RAM - FSP
see event 233
Does not exist!
RAM - xxx
RAM - CTRL
see event 233
RAM - Comm
see event 233
274410789.xls
06/23/2015
Owner: TJA
Action
RAM - FSP
see event 233
Does not exist!
RAM - xxx
Description: No contact to sensor
End-user: Restart the inverter. If error persists call installer
Installer: Replace inverter
solve for New production - week 48-2011
Gate driver problem can be seen in Refurbish Inverter After Week 48-2011
It
seems thatInternal
the error
212(trafotoo
and
Gate driver problem ) can trigger the event 241
Description:
parameter
low
End-user: Call Danfoss Service
Installer: Exchange the inverter
Insulation test Difference
- Active in SW 2,10
Description: Unable to change the voltage between ground and neutral during isolation test (by less
than 10 V)
End-user: Call Danfoss Service
Installer: Check the PV installation for isolation error. If ok, exchange the inverter.
- Active in SW 2,10
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Short circuit boost transistor or wrong PV polarity
End-user: Call Danfoss Service/installer
Installer: Check the PV installation for polarity errors. If ok, exchange the inverter.
- Active in SW 2,10
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Test of inverter relay and voltage measurements cannot be performed
End-user: Call Danfoss Service
Installer: Exchange the inverter
274410789.xls
06/23/2015
Owner: TJA
Action
software Bug - solution new SW Controlboard 1,18/1,19 ( SW 3.10 )
if SW 3.00 update the SW
If SW Below 1.12 update SW (old Com Card )
Capa case number - In process
Description: Grid relay has failed (assumed open circuit)
End-user: Call Danfoss Service
Installer: Exchange the inverter
Description of failure:
HW: All
SW: <3.10
To be categorized as 8018:
The Customer complains error 361.
The Fault Code is 361 or failure 361 is written in the failure description.
The Inverter must run in mode 60 when tested.
There must be no other related errors when tested.
The Event- and data log has event 361 stored.
The max AC value in The TLX- or SE files exceeds more than 300 Vac in one or more phases.
Be aware:
Sometimes the log in the files is newer than the date the Inverter is complaint.
If the SW is 3.10 or higher when the event occurs, The MQG team must be advised immediately.
Other info:
This error is formerly known as: AUX/GRID/RL20x/361 or AUX/GRID/RL20x/INTERMITTENT
AUX board will no longer be replaced in the inverters with this error.
274410789.xls
06/23/2015
Owner: TJA
Action
Description: Neutral relay has failed (grid relay assumed welded)
End-user: Call Danfoss Service
Installer: Exchange the inverter
Capa case number - In process
Description: Neutral connection is damaged or missing
End-user: Call Danfoss Service/installer
Installer: Check AC installation for failure on neutral connection. Call Danfoss Service
Verify that the AC installation is correct according to the installation manual. Verify that the neutral wire
is connected. Failure is mostly in the installation!
Capa case number - 152591
Description of failure:
HW: All
SW: ALL
To be categorized as 8019:
The Customer complains error 364 or like.
The Fault Code is 364 or failure 364 is reported in the failure text.
The Inverter must run in mode 60 when tested.
There must be no other related errors when tested.
The Event- and data log has event 364 stored.
The Op- time must be few days without have been ON GRID.
The Installation date is 01-01-1970.
Max power, L1, L2 and L3 = 0 W.
The max AC value in The TLX- or SE-files often exceeds more than 300 Vac in one or more phases.
Be aware of: Verify that the screw to the NULL-wire doesnt go tight. If it is the reason
Select Fault Reason Code 2031 and write the summary: AUX/MAIN_PAGE/J100/DAMAGED
Other info:
This error is formerly known as: AUX/GRID/RL20x/364
or AUX/GRID/RL20x/INTERMITTENT
AUX board will no longer be replaced.
Report to Customer Claim Manager if this Inverter is claimed as an exchange
274410789.xls
06/23/2015
Owner: TJA
Action
274410789.xls
06/23/2015
FAT for
TripleLy
nx
3-phase
Danfoss
Solar Inverter
Owner: PE-SS
Contact person: Jens Meilandt
Tel: +45 7488 2854
274410789.xls
Revision list