Series B E3

Electronic Overload Relays


Features

CONTROL

DeviceNet Ready
(ODVA Conformance Tested)

PROTECTION

0.45000A Current Range


True RMS Current Sensing (20250 Hz)
Wide 5:1 Adjustment Range
IEC and NEMA Configurations
Over Molded Power Connections
Rotary Node Address Switches
Integrated I/O
Advanced Protection Functions with
Programmable Trip and Warning Settings
Motor Data Monitoring
Diagnostic Functions
Flash Memory

COMMUNICATIONS

E3 version offers:
2 Inputs / 1 Output
E3 Plus version offers:
4 Inputs / 2 Outputs
Low Level (15A) Ground Fault
Protection
PTC Thermistor Monitoring
DeviceLogix Component Technology
2-Speed Motor Protection

The Allen-Bradley Series B E3 Overload Relays expanded protection and control


functions deliver effective motor management to prevent and minimize production
downtime.
Critical protective functions can prevent motor damage and provide advance
notification of a machines performance being outside the boundaries of normal
operation.
DeviceNet network communication delivers immediate access to motor
performance and diagnostic data in addition to seamless control.
Integrated I/O provides convenient local termination of motor-related inputs and
outputs, simplifying the control architecture.
DeviceLogix component technology increases the control possibilities with function
block programs that operate at the device level.

Product Profile

Advanced Protection
First and foremost, the E3 Overload Relays provide advanced motor protection. What once required a combination of specialized protection
relays can now be accomplished cost-effectively with one compact device. User-adjustable parameters for all trip and warning functions
allow the E3 Overload Relays to be tailored to the application for providing a precise envelope of protection.

Thermal Overload

Jam

Precise hall effect current sensing combined with


microprocessor algorithm processing delivers accurate motor
thermal protection

A quick response to a mechanical jam reduces the potential for


damage to the motor and the power transmission components

Trip class adjustable from 5 to 30 in increments of one


Manual and automatic reset modes are available

Trip level adjustable from 50 to 600% FLA


Trip delay adjustable from 0.1 to 25.0 seconds
Warning level adjustable from 50 to 600% FLA

Reset level adjustable from 1 to 100% thermal capacity utilized


Warning level adjustable from 1 to 100% thermal capacity
utilized
E3 Plus offers a second FLA setting for two-speed motor
protection

Phase Loss

Underload
A drop in current can be a sign of pump cavitation, tool or belt
breakage rapid detection can help minimize damage and aid
in reducing production downtime
Trip level adjustable from 10 to 100% FLA
Trip delay adjustable from 0.1 to 25.0 seconds

Responsive phase loss detection protects motors from the


second leading cause of motor failure

Warning level adjustable from 10 to 100% FLA

Trip level factory set at 100% current imbalance

PTC Thermistor Monitoring E3 Plus

Trip delay adjustable from 0.1 to 25.0 seconds

Ground (Earth) Fault E3 Plus

Provides enhanced motor protection in cases where motor


overheating cannot be detected by monitoring current alone
(blocked ventilation or high ambient temperature)

Class 1 low level (arcing) ground fault protection can provide


early detection before a catastrophic fault develops

Built-in circuitry for monitoring motor winding-embedded


positive temperature coefficient (PTC) thermistors

The core balance (zero sequence) sensor is incorporated into


devices rated through 90A

Current Imbalance

Trip level adjustable from 1.0 to 5.0 amperes

Prevent increased motor heating that results from negative


sequence currents associated with current imbalance

Trip delay adjustable from 0.1 to 25.0 seconds


Warning level adjustable from 1.0 to 5.0 amperes
Selectable trip inhibit feature can be employed to prevent
opening of the motor starting contactor when the ground fault
current rises beyond the sensors saturation point and has the
potential to exceed the contactors interruption rating

Trip level adjustable from 10 to 100%


Trip delay adjustable from 0.1 to 25.0 seconds
Warning level adjustable from 10 to 100%

Remote Trip

Stall

External devices such as vibration sensors can be monitored


through the E3 Overload Relays discrete inputs

Monitor motor acceleration on start to ensure full speed is


achieved in the proper amount of time

Discreet inputs are configurable with an option for assigning


the remote trip function

Trip level adjustable from 50 to 600% FLA


Enable time adjustable from 0 to 250 seconds

Communications
Built-in DeviceNet communications streamlines the effort of connecting a motor starter to an automation network, enabling remote start-stop
control and providing access to vital motor operating data. Having fewer components to install reduces the time and cost of installation as
well as improving system reliability.

Motor Current Monitoring

Motor Diagnostics

Individual phase currents (in amperes)

Device status

Individual phase currents (as % FLA)

Trip status

Average current (in amperes)

Warning status

Average current (as % FLA)

Time to trip (on thermal overload)

Ground fault current (in amperes)

Time to reset (after thermal overload trip)

Current imbalance percentage

History of past five trip events

Percentage of thermal capacity utilized

Control
The E3 overload relays provide integral inputs and outputs that can simplify the control architecture. Additionally, the Series B E3 Plus
Overload Relay offers increased control flexibility with DeviceLogix capabilities. Using RSNetWorx for DeviceNet (version 3.0 or later),
function block programs can be configured and saved to an E3 Plus overload relay to operate simple logic routines. The function blocks are
programmed using standard Boolean operators such as AND, OR, XOR, NOT plus timers, counters and latches. In addition to allowing the use
of the integral hardware and network inputs, protective functions can also be used as inputs to trigger outputs. For example, the Ground Fault
protection function could be used to control Output A of the E3 Plus Overload Relay for operation of a circuit breaker shunt trip mechanism.
DeviceLogix has many applications and the implementation is typically only limited to the imagination of the programmer.

Benefits of DeviceLogix:
Faster sense-to-actuate response

Increased uptime through distributed control architecture

Local processing

Reliable operation under failures or during maintenance operations

Higher network performance


Increased system/machine modularity
Increased system reliability

Control distributed throughout machine

Improved diagnostics and reduced troubleshooting

Reduced program size in the master improves processing and scan times

Reduced potential points of failure at system level

Bulletin 193 IEC Devices


Mounts to Contactor

100-C09C23

100-C30C43

100-C60C85

100-D95D180

100-D210D420

100-D630D860

Adjustment Range (A)

E3 Cat. No.

E3 Plus Cat. No.

0.42.0

193-EC1PB

193-EC2PB

15

193-EC1AB

193-EC2AB

315

193-EC1BB

193-EC2BB

525

193-EC1CB

193-EC2CB

15

193-EC1AD

193-EC2AD

315

193-EC1BD

193-EC2BD

525

193-EC1CD

193-EC2CD

945

193-EC1DD

193-EC2DD

945

193-EC1DE

193-EC2DE

1890

193-EC1EE

193-EC2EE

28140

193-EC1FF

193-EC2FF

42210

193-EC1GF

193-EC2GF

42210

193-EC1GG

193-EC2GG

60302

193-EC1HG

193-EC2HG

84420

193-EC1JG

193-EC2JG

125630

193-EC1KH

193-EC2KH

172860

193-EC1LH

193-EC2LH

Adjustment Range (A)

E3 Cat. No.

E3 Plus Cat. No.

Bulletin 592 NEMA Devices


Mounts to Starter Size

00

02

0.42.0

592-EC1PT

592-EC2PT

15

592-EC1AT

592-EC2AT

315

592-EC1BT

592-EC2BT

0.42.0

592-EC1PC

592-EC2PC

15

592-EC1AC

592-EC2AC

315

592-EC1BC

592-EC2BC

525

592-EC1CC

592-EC2CC

945

592-EC1DC

592-EC2DC

945

592-EC1DD

592-EC2DD

1890

592-EC1ED

592-EC2ED

Devices for Use with External Current Transformers


Mounts to

Adjustment Range (A)

E3 Cat. No.

E3 Plus Cat. No.

193-ECPM2

95000

193-EC1ZZ

193-EZ2ZZ

www.rockwellautomation.com

www.ab.com

Corporate Headquarters
Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201
Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Headquarters for Dodge and Reliance Electric Products
Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433
Europe/Middle East/Africa: Rockwell Automation, Herman-Heinrich-Gossen-Strasse 3, 50858 Kln, Germany, Tel: 49 (0) 2234 379410, Fax: 49 (0) 2234 3794164
Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 6356 9077, Fax: (65) 6356 9011
Publication 193-PP017A-EN-P January 2005