Beruflich Dokumente
Kultur Dokumente
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. PCS0534
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.
The air conditioners manufactured All Daikin Industries locations About ISO 14001
by Daikin Industries have and subsidiaries in Japan have ISO 14001 is the standard defined by the
received ISO 9001 certification for received environmental International Organization for Standardization (ISO)
quality assurance. management system standard relating to environmental management systems.
ISO 14001 certification. Our group has been acknowledged by an
Certificate Number. JMI-0107
JQA-0495 internationally accredited compliance organisation
Daikin Industries, Ltd.
JQA-1452 Domestic Group as having an appropriate programme of
Certificate Number. EC99J2044 environmental protection procedures and activities
to meet the requirements of ISO 14001.
Head Office:
Umeda Center Bldg., 4-12, Nakazaki-Nishi
2-chome, Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 18-1, Konan
2-chome, Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global/
C r e a t io n o f
The specifications, designs, and information in this brochure are subject to change without notice.
c All rights reserved
Printed in Japan 02/05/003 SW • HP • SS
C o m fo r t
Cooling only
HP 2 2.5 3 4 5 6 8 10 15 20
Capacity *1 kW 5.6 6.8 8.1 11.4 14.3 15.8 24.0 29.2 47.9 58.4
Btu/h 19,100 23,200 27,800 38,900 48,800 53,900 81,800 99,600 163,500 199,400
kcal/h 4,820 5,850 7,000 9,800 12,300 13,500 20,600 25,100 41,200 50,200
CEILING MOUNTED
CASSETTE TYPE
Specifications Page 24
Indoor unit FDB50KVE FDB60KVE FDB71KVE
Outdoor unit R50GVAL R60GVAL R71FUVAL
MIDDLE STATIC
PRESSURE TYPE
DUCT
CONNECTION
Specifications Page 24
Page 15– 16 Indoor unit FDM03FAVAL FDM04FAVAL FDM05FAVAL FDYM06FAVAL
Outdoor unit R71FUVAL R100FUVAL R125FUTAL R140KUTALK
HIGH STATIC
PRESSURE TYPE
OUTDOOR UNIT
Page 17– 18
R125KUYALK R125FUTAL R140KUTALK RU06KTAL RU08KUTAL RU10KUTAL RU08KUTAL × 2 RU10KUTAL × 2
R50GVAL R60GVAL R71FUVAL R100FUVAL R140KUYALK RU08KTAL RU10KTAL RU08KTAL × 2 RU10KTAL × 2
Notes)
•*Capacities of FD series are gross capacities which do not include a deduction for evaporator fan motor heat.
*1. The values given on the right are for the FHYC type. Values for other types may differ slightly.
The values given for 8HP to 20HP are for the FD type.
1 2
Cooling only
Page 19– 20
Simultaneously running
Specifications
Simultaneous operation system TWIN MULTI OPERATION Page 27– 29
HP 6 8 10
Capacity *1 kW 15.8 22.2 26.6 2 to 4 units completely
Btu/h
kcal/h
53,900
13,500
75,800
19,100
90,800
22,900
distributes comfort across
CEILING MOUNTED wide spaces.
CASSETTE TYPE
CEILING SUSPENDED
TYPE
DUCT CONNECTION
MIDDLE STATIC PRESSURE
TYPE Large room air conditioned by
Simultaneous control with Simultaneous control with
simultaneous control of four
Indoor unit FDYM04FAVAL × 2 FDYM05FAVAL × 2 2 units in spacious room 3 units for irregularly shaped room
distributed units
Outdoor unit R200KUTAL/YAL R250KUTAL/YAL
OUTDOOR UNIT
Page 17– 18
R200KUTAL R250KUTAL
R140KUTALK R200KUYAL R250KUYAL
*1. The values given on the right are for the FHYC type. Page 19– 20 Specifications Page 27– 28
CEILING MOUNTED
CASSETTE TYPE
OUTDOOR UNIT
Page 17– 18
Heating kW 6.3 7.19 9.0 12.8 16.2 18.1 23.2 29.5 44.8 56.8
Btu/h 21,500 24,500 30,600 43,700 55,200 61,900 79,200 100,700 153,000 194,000
kcal/h 5,420 6,180 7,700 11,000 13,900 15,600 20,000 25,400 38,500 48,800
Page 9– 11
Indoor unit FHYC50KVE FHYC60KVE FHYC71KVE FHYC100KVE FHYC125KVE FHYC140KVE
Specifications Page 30 Outdoor unit RY50GVAL RY60GVAL RY71FUVAL RY100FUVAL RY125FUTAL RY140KUTALK/YALK
Page 12
Indoor unit FHY50BVE FHY60BVE FHY71BVE FHY100BVE FHY125BVE
Specifications Page 30 Outdoor unit RY50GVAL RY60GVAL RY71FUVAL RY100FUVAL RY125FUTAL
Page 13
Indoor unit FHYB71FVAL FHYB100FVAL FHYB125FVAL
Specifications Page 31 Outdoor unit RY71FUVAL RY100FUVAL RY125FUTAL
Page 14
Indoor unit FAY71FVE FAY100FVE
Specifications Page 31 Outdoor unit RY71FUVAL RY100FUVAL
Page 14
Indoor unit FVY71LAVE FVY100LAVE FVY125LAVE
Specifications Page 32 Outdoor unit RY71FUVAL RY100FUVAL RY125FUTAL
PACKAGED AIR CONDITIONERS
LOW STATIC PRESSURE
TYPE
OUTDOOR UNIT
Notes)
•*Cooling capacities of FDY series are gross capacities which do not include a deduction for evaporator fan motor heat.
*1. The values given on the right are for the FHYC type. Values for other types may differ slightly.
The values given for 8HP to 20HP are for the FDY type.
5 6
Heat pump
CEILING SUSPENDED
TYPE
OUTDOOR UNIT
Page 17– 18
RY200KUTAL RY250KUTAL
RY140KUTALK RY200KUYAL RY250KUYAL Page 19– 20 Specifications Page 34– 36
CEILING MOUNTED
CASSETTE TYPE
CEILING SUSPENDED
TYPE
OUTDOOR UNIT
Page 17– 18
*1. The values given on the right are for the FHYC type.
RY200KUTAL RY200KUTAL RY250KUTAL
RY140KUTALK RY200KUYAL RY200KUYAL RY250KUYAL
7 8
Super cassette type is more compact, lighter and
CEILING MOUNTED CASSETTE
CEILING-MOUNTED CASSETTE TYPE
TYPE easier to install than the conventional types.
F H (Y )C 5 0 – 1 4 0 K Maintainability also greatly improved.
Sound level Wired LCD remote controller Wireless LCD remote controller
Compact and aesthetic square panel type
3 5 /3 0
[High] [Low]
dB A signal rec eiver must be
added to the indoor unit.
FHYC71K
Uniform panel size for all models.
The conventional 100– 140models' rectangular panel types have all been
converted to the same compact square type as the 50– 71models. This
permits smooth interior harmony of ceilings with the lighting fixtures.
BRC1C61
BRC7C613W Installation of multiple air conditioners of different capacities will also be
(for c ooling only type)
Note: R emote c ontroller c able not Signal receiver unit
inc luded. C ables must be (Installed type)
BRC7C612W
proc ured loc ally. (for heat pump type)
FH(Y)C50K–71K FH(Y)C100K–140K
4-way 3-way 2-way 4-way 3-way 2-way
air flow air flow air flow air flow air flow air flow
9 10
CEILING SUSPENDED TYPE
Accessory required for indoor unit (option)
F H ( Y ) 5 0 –1 2 5 B
Wired LCD remote controller Wireless LCD remote controller
Soiling of ceiling reduced 30–40% (compared to conventional models). Cleaning is simple because of the "Non-dew Flap" with no flocking.
Although flocking is presently used on flaps to prevent dewing, the
Conventional system New system new flaps are "Non-dew Flaps" that do not soil easily and are easy to
Signal receiver unit
BRC1C61
BRC7E66 (Installed type)
Sound level Note: R emote c ontroller c able not
(for c ooling only type)
inc luded. C ables must be
BRC7E63W
3 9 /3 5
Horizontal proc ured loc ally.
(for heat pump type)
discharge
Non-dew flap
[High] [Low]
dB
Stepping motor
Wireles s remote c ontroller and s ignal
FHY71B rec eiver unit are s old as a s et.
Newly set angle Newly set angle
Once Once
2years 3years
New model
100°
Maintenance is simple
Installable on ceilings
Long-life filter lasts about 1 year *
3. 5 m high.
Maintenance not required.
* For dust concentration of 0.15 mg/m3
Usingthe optional accessories produces anevenhigher level of comfort
Two time settings (2500 hrs and 1250 hrs) are available to match the installation
Fresh air intake kit (Option) Branch duct chamber (Option) environment. Maintenance time warning is displayed on the remote controller
(filter sign).
Allows intake of fresh air from the outdoors. When neither heating In addition to discharging air from the outlet on the decoration panel,
nor cooling is required, fresh air can be circulated by only using the a duct can be connected to the air conditioner itself for an additional
fan. This is especially useful in buildings in which ventilation fans discharge outlet. The additional discharge outlet is useful for areas
Two Select thermo-sensors
which tend to be crowded or near doors or windows where the
temperature is affected by the outside temperature. Thermo-sensors on both indoor unit and wired remote con-
troller (option). Temperature detection can be set closer to
the living area to further improve comfort level.
Fresh air intake kit Air filter (Outdoor)
Intake duct * Indoor unit's thermo-sensor must be used when the air conditioner is controlled
Hood from another room. (Wireless remote controller does not have a thermo-sensor.)
(Option)
11 12
CEILING MOUNTED BUILT-IN TYPE WALL MOUNTED TYPE
Accessory required for indoor unit (option)
F H Y B 7 1 –1 2 5 F F A ( Y ) 7 1 /1 0 0 F
Wired LCD remote controller Wireless LCD remote controller
By separating the air outlet from the main unit and blowing air, various
conditions will be cleared such as in modified stores, state of sunshine
and gathering of people to realize comfortable air conditioning.
Long-life filter
Liquid crystal control panel
(Standard equipment)
Long-life filter
The unit can be installed, if there is a space of 350 mm Air suction panel* Air suction
above ceiling. (when suction panel is used.) canvas bellows*
The panel can also be removed and used for remote
control such as controlling air conditioning from a
With duct (case 1) Cassette style (high efficiency filter)
different room or from near the cashier.
Min. High-efficiency
350 mm filter*
Screening
door* Access panel* These units are number one in the world in quietness and lightness.
Long-life Filter is provided as a standard accessory. Air suction panel* Air suction The use of a high-efficiency, long-life filter reduces maintenance time and cost.
canvas bellows*
The heat exchanger has been subjected to antibacterial treatment and mildew proofing.
(Option)
13 14
DUCT CONNECTION MIDDLE STATIC DUCT CONNECTION LOW STATIC
PRESSURE TYPE F D ( Y ) M 0 3 –0 6 F A PRESSURE TYPE F D ( Y ) B 5 0 –7 1 K ( A )
Accessory required for indoor unit (option)
Sound level
Accessory required for indoor unit (option)
Wired LCD remote controller Wireless LCD remote controller
Note: The unit shown in the photo is a dedicated cooling type. A signal rec eiver must be
Switch box dimensions differ for combination cooling/heating type. added to the indoor unit.
Sound level BRC1C61 BRC4C64 (for c ooling only type) Signal receiver unit
These duct type air conditioners can be installed in the ceiling space
for an attractive interior finish. Daikin's middle static pressure duct type For cooling only type
air conditioners are compact and quiet, well-suited for use in a wide Digital remote controller Remote controller
variety of duct type air conditioning systems for homes, stores, and
offices.
Suction Chamber
(standard equipment)
305 mm or more
46 [Low] dB
Wired LCD remote controller Wireless LCD remote controller
When air conditioning two rooms simultaneously, the air For cooling only type
discharged into each room must be circulated back to the air Digital remote controller Remote controller
conditioner. To ensure this, a ventilation duct should be
installed for each room or one of the indicated ventilation
grilles should be installed on the partitioning wall or under the Door-installed Wall-installed KRC47-5 KRC47-3
door between the rooms. ventilation grille ventilation grille Under-door cutout
Cooling only
Heat pump only
15 16
Outdoor Unit
Flexible design
for large room or
multi-use
Reduces installation space. 200 and 250 models can be combined for Also adapts to year-round cooling
( Applies to R71–125FU and 140KU )
Long hypotenuse blades Common width and depth make series installation easy. RY200KU and RY250KU can adapt up to 0°C.
Long hypotenuse blades with a gentle camber make the pressure rise on the
(Optimal camber)
surface of the blades smooth and uniform, while suppressing break away of
the flow. As a result, it prevents rise in draft resistance produced due to lack of
50
open space behind the unit, and prevents air power from dropping.
0
50
in two types depending on
R(Y)200KU R(Y)200KU R(Y)250KU installation conditions
"Air Flow Adjustment Guide" (standard equipment).
( Applies to R71–125FU and 140KU ) 690 mm
RU08/10KU models are factory shipped with
Outdoor units include as standard equipment the "Air Flow Adjustment
refrigerant charged for 5 meters of piping.
Cross-section of "Air Flow Adjustment Guide".
Guide" which lets you set as desired the air flow in any one of four RU08/10K models are factory shipped with no
1280 mm 1280 mm 1280 mm
directions in accordance with your layout. Cushions effect of air flow refrigerant charged.
striking against obstructions in front of the unit (walls,etc.) and prevents
Allowable refrigerant pipe length and height difference
"short circuits" from being formed.
Pre-charged Max. length Max. height
30° *1 difference
50 m
R(Y)200KU 5m (Equivalent length 70 m) 30 m
50 m
As show in the diagram, the air flow adjustment guide is factory set R(Y)250KU 5m (Equivalent length 70 m) 30 m
so that exhaust air flow is inclined 30 degrees. The guide can be set
1
to direct the air flow to the left, right or down as well as upward, so Note: Additional refrigerant charging is required if the refrigerant pipe is
longer than the indicated length.
you can adjust the direction according to the place of installation.
17 18