EXCELAIR RSRL Terminal Housing Boxes are ideal for clean room applications for supplying Laminar
flow air to provide clean air. EXCELAIR Terminal Housing boxes are compact in design and easy to
install. It has Provision for easy connection to the duct. Installation of box is so easy by using the
fasteners and duct connection is through the flexible ducts or some other duct connectors. Terminal
Housing Box with Top opening with Damper control is also available.
The Housing Box shall be designed according to the Airflow & Velocity requirements.
Duct Connection
The hood shall have an integral duct connected spigot in the side to connect to the flexible duct easily.
The spigot diameter shall be 200 mm, 250mm or 305mm. The hood shall have an opening option
at the top. It may be round or rectangular spigot provision with flanges to connect to the duct easily.
Installation
The Terminal hood shall have the side Hanging Tabs, permanently welded with the hood, having 10
mm Dia hole to fasten it. The hanging tabs are to hang with threaded rods or to fix with some HVAC
work place in operation theatre.
Filter Installation
The hood shall have a channel to fix the Hepa filters and the filters clamped with help of SS fasteners
with the box. Filter Replacement is from the front side of the housing box by removing the socket
and the fasteners.
www.cmsglobal.com
Filter selection
The Hepa filter shall be selected as per the Clean room standard ISO 14644 to ensure the quality of
High efficiency filter.
The operating maximum velocity of the filter is 100 fpm. The Filter dimension is based on the Airflow.
For selection of filters, contact the factory.
www.cmsglobal.com
ADDITIONAL OPTIONS
www.cmsglobal.com
The Filter Replaceable Terminal Module RSRL is designed for applications that require frequent filter
testing and routine cleaning procedures as in hospitals, surgical rooms, pharmaceutical firms and
biotechnology Cleanrooms.
The Filter is easy to install, change and provides an optimum service life. A gel seal between the filter
and hood eliminates any by-pass of air leakage.
The RSRL module shall have the filter depth range from 66mm to 150mm profile depth.
particle size.
SELECTION CHART
Housing Details
Termi RSRL
LFA-H14
LFB-H14
LFC-H14
MP GEL-H14
RSRL 1
100
0.49
0.38
0.33
0.49
RSRL 2
200
0.49
0.38
0.33
0.49
RSRL 3
300
0.49
0.38
0.33
0.49
RSRL 4
400
0.49
0.38
0.33
0.49
RSRL 5
600
0.49
0.38
0.33
0.49
RSRL 6
800
0.49
0.38
0.33
0.49
SELECTION CHART
Housing Details
Termi RSRL
LFA-H13
LFB-H13
LFC-H13
MP GEL-H13
RSRL 7
100
0.44
0.33
0.29
0.44
RSRL 8
200
0.44
0.33
0.29
0.44
RSRL 9
300
0.44
0.33
0.29
0.44
RSRL 10
400
0.44
0.33
0.29
0.44
RSRL 11
600
0.44
0.33
0.29
0.44
RSRL 12
800
0.44
0.33
0.29
0.44
www.cmsglobal.com