Beruflich Dokumente
Kultur Dokumente
www.murata-ps.com
Power density 2.68W/cm3
Wide temperature performance at full
3 Watt load, 40C to 85C3
UL 94V-0 package material
No heatsink required
Parameter
Isolation
Capacitance
MTTF2
70
45
45
45
60
40
40
40
pF
MHrs
80
84
83
85
82
84
84
85
83
87
86
88
85
88
88
89
32
50
41
51
42
66
77
91
3.9
2.9
4.2
2.5
3.6
3.7
3.4
3.4
Voltage range
Reected ripple current
Conditions
Min.
Typ.
Max.
4.5
10.8
5
12
5
5
5.5
13.2
15
15
Typ.
Max.
Units
1.01
1.1
%/%
Typ.
Max.
Units
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power
Voltage Set Point Accuracy
Line regulation
TA=-40C to 85C
See tolerance envelope
High VIN to low VIN
No external components required
mVp-p
5V & 12V input
Fully encapsulated with toroidal
magnetics
46
28
26
24
41
21
19
21
INPUT CHARACTERISTICS
Industry standard pinout
5V, 9V, 12V, & 15V output
8
6.5
6
6.5
6
5
4.5
4
%
6.3
5.2
4.7
4.7
4.3
3.5
3
2.7
Efciency (Min.)
703
677
691
679
290
280
280
277
mA
600
333
250
200
600
333
250
200
Load Regulation
(Typ)
Input Current at
Rated Load
mA
5
9
12
15
5
9
12
15
Efciency (Typ.)
Typical efciency from 83%
5
5
5
5
12
12
12
12
RoHS compliant
V
MEE3S0505SC
MEE3S0509SC
MEE3S0512SC
MEE3S0515SC
MEE3S1205SC
MEE3S1209SC
MEE3S1212SC
MEE3S1215SC
Load Regulation
(Max)
UL 60950 recognized
Output
Voltage
FEATURES
Nominal Input
Voltage
Order Code
Output Current
SELECTION GUIDE
Min.
Units
V
mA p-p
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
No electrolytic or tantalum capacitors
1000
10
PRODUCT OVERVIEW
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Switching frequency
VDC
G
Typ.
Max.
60
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specication
Storage
-40
-50
Typ.
MEE3Sxx05SC, MEE3S0512C
MEE3S0515C, MEE3S1209C, MEE3S1212C
MEE3S1215C, MEE3S0509C
Free air convection
Max.
Units
85
125
40
35
30
260C
7V
15V
www.murata-ps.com/support
KDC_MEE3.A03 Page 1 of 5
MEE3 Series
1kVDC Isolated 3W Single Output DC/DC Converters
TEMPERATURE DERATING GRAPH
85C
3.0
1.5
Output Voltage
4.5
l Loa
VNOM
d Lin
0%
0
-40
2%
Typic
a
25
50
75
-4%
100
100
50
0
Ambient Temperature (C)
150
The voltage tolerance envelope shows typical load regulation characteristics for
this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading.
TECHNICAL NOTES
ISOLATION VOLTAGE
Hi Pot Test, Flash Tested, Withstand Voltage, Proof Voltage, Dielectric Withstand Voltage & Isolation Test Voltage are all terms that relate to the same thing, a test voltage,
applied for a specied time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MEE3 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, What is the continuous voltage that can be applied across the part in normal operation?
The MEE3 series has been recognized by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
SAFETY APPROVAL
The MEE3 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional isolation in a maximum still air ambient temperature of 63C and/or case temperature limit of 91C. Case temperature measured on the face opposite the pins. File number E151252 applies.
The MEE3 series of converters are not internally fused so to meet the requirement of UL 60950, an input line fuse should always be used. An anti-surge 2.5A should be used for
MEE3S05xxSC models, and an anti-surge 1A should be used for MEE3S12xxSC models. All fuses should be UL approved and rated to at least the maximum allowable DC input
voltage.
www.murata-ps.com/support
KDC_MEE3.A03 Page 2 of 5
MEE3 Series
1kVDC Isolated 3W Single Output DC/DC Converters
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
DC
Power
Source
MEE3S0505SC
MEE3S0509SC
MEE3S0512SC
MEE3S0515SC
MEE3S1205SC
MEE3S1209SC
MEE3S1212SC
MEE3S1215SC
L, H
10
22
47
47
10
22
47
47
Load
DC
Inductor
SMD
Through Hole
84103C
11R103C
84223C
11R223C
84473C
11R473C
84473C
11R473C
84103C
11R103C
84223C
11R223C
84473C
11R473C
84473C
11R473C
Capacitor
C, F
4.7
2.2
1
1
4.7
2.2
1
1
C1
1F X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10F tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100m at 100 kHz
C3
R1
R2
50 BNC termination
T1
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
C1 C2 C3
+
SUPPLY
Input
R1
T1
R2
Y INPUT
Output
R LOAD
www.murata-ps.com/support
KDC_MEE3.A03 Page 3 of 5
MEE3 Series
1kVDC Isolated 3W Single Output DC/DC Converters
EFFICIENCY VS LOAD
MEE3S12xxSC Input Voltage
100
100
90
90
80
80
70
70
Efciency (%)
Efciency (%)
60
15V
12V
9V
5V
50
40
50
40
30
30
20
20
10
10
0
0
10
20
30
40
50
Load (%)
60
70
80
90
100
15V
12V
9V
5V
60
0
0
10
20
30
40
50
Load (%)
60
70
80
90
100
www.murata-ps.com/support
KDC_MEE3.A03 Page 4 of 5
MEE3 Series
1kVDC Isolated 3W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
SIP Package
14.15
(0.557) Max.
8.15
(0.321) Max.
Function
1
2
3
4
-VIN
+VIN
-VOUT
+VOUT
MEE3S0505SC
XYYWWi
4.10.5
(0.160.020)
17.00 (0.669)
0.4 (0.016)
Min.
11.43 (0.45)
10.15
(0.400) Max.
Pin
0.55 (0.022)
0.45 (0.018)
3.16 (0.124)
3.87 (0.152)
0.25 (0.100)
1.00-1.45
(0.039-0.057)
4.00
(0.157)
9.05 (0.356)
7.62
(0.300)
0.500.15
(0.1970.006)
All dimensions in mm 0.1mm (inches 0.004). All pins on a 2.54 (0.1) pitch
and within 0.25 (0.01) of true position.
Weight: 2.3 g
Tube Quantity: 35
1.00 (0.0394)
2.54
(0.1)
2.54
(0.1)
Unless otherwise stated all dimensions in mm (inches) 0.5mm.
www.murata-ps.com/support
KDC_MEE3.A03 Page 5 of 5