INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M],
FVR20C2(M,S)2 & FVR40C4(M,S)4
SINGLE, DUAL OR QUAD-CHANNEL 10-BIT DIGITALLY ENCODED
SHORT-HAUL VIDEO AND CONTACT CLOSURE

This manual serves the following


ComNet Model Numbers:

FVT10C1M1/M
FVT10C1S1/M
FVT10C1M1
FVT10C1S1
FVR10C1M1
FVR10C1S1
FVR20C2M2
FVR20C2S2
FVR40C4M4
FVR40C4S4

The ComNet series video transmitters and receivers support the transmission of one,
two, or four independent short-haul quality 10-bit digital video signals and one, two,
or four contact closures in the direction of the video over multimode or single mode
optical fibers. These modules are universally compatible with major CCTV camera
manufacturers. The receivers are compatible with the FVT1(M,S)1/M* series single
channel transmitters. Plug-and-play design ensures ease of installation and no electrical
or optical adjustments are ever required.
Bi-color (Red/Green) LED indicators are provided for rapidly confirming operating
status. Please see Figure 10 on Page 7 for LED explanations.
The FVT10C1(M,S)1/M units have a small footprint and are ideal for mounting where
space is limited or can be mounted inside equipment housing. The remaining ComFit
units may be either wall or rack-mounted. Please see Figures A and B on Page 8 for
mounting instructions.

* FVT1(M,S)1/M not available in North America.

TECH SUPPORT: 1.888.678.9427

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV- Rev. 06.30.14

PAGE
1

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4

FIGURE 1 FVT10C1/M TRANSMITTER

Power Supply:
9 36VDC @ 2W
OR
12 24 VAC @ 2W

Power Input &


Contact Closure

BNC
Video

Multimode or Single Mode


Optical Fiber

FIGURE 2 FVT10C1/M TRANSMITTER


FRONT PANEL

REAR PANEL

TECH SUPPORT: 1.888.678.9427

Mounting
Bracket
(Included)

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
2

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4

FIGURE 2 FVT10C1 TRANSMITTER

Multimode or Single Mode Optical Fiber


Video Signal In
Contact In
Black
Black With White Stripe

Power Supply:
Surface Mount: 8 15VDC @ 2W
Rack Mount: From Rack

FIGURE 3 FVT10C1 TRANSMITTER


FRONT PANEL

TECH SUPPORT: 1.888.678.9427

NOTE: R
 emove Electrical
Connector for Rack
Mount Units

REAR PANEL

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
3

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4

FIGURE 4 FVR10C1 RECEIVER

Video Signal Out


Contact Out
Multimode or Single Mode
Optical Fiber

Black
Black With White Stripe

Power Supply:
Surface Mount: 8 15VDC @ 2W
Rack Mount: From Rack

FIGURE 5 FVR10C1 RECEIVER


FRONT PANEL

TECH SUPPORT: 1.888.678.9427

NOTE: R
 emove Electrical
Connector for Rack
Mount Units

REAR PANEL

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
4

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4

CHANNEL 1

FIGURE 6 FVR20C2 RECEIVER

Video Signal Out


Contact Out

CHANNEL 2

Multimode or Single
Mode Optical Fiber

Video Signal Out


Contact Out
Black
Black With White Stripe

Power Supply:
Surface Mount: 8 15VDC @ 2W
Rack Mount: From Rack

FIGURE 7 FVR20C2 RECEIVER


FRONT PANEL

TECH SUPPORT: 1.888.678.9427

NOTE: R
 emove Electrical
Connector for Rack
Mount Units

REAR PANEL

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
5

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4

FIGURE 8 FVR40C4 RECEIVER

CH1 Video
Signal Out

CH2 Video
Signal Out

Multimode or
Single Mode
Optical Fiber

CH3 Video
Signal Out
Contact Out
Contact Out

CH4 Video
Signal Out

Black
Black With White Stripe

Operating Voltage
Range: 8 to 15VDC
Power Consumption: 4W
NOTE: R
 emove Electrical
Connector for
Rack Mount Units

FIGURE 9 FVR40C4 RECEIVER


FRONT PANEL

TECH SUPPORT: 1.888.678.9427

REAR PANEL

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
6

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4

FIGURE 10 LED INDICATORS


LINK (RECEIVERS ONLY)

VIDEO

CONTACT*

GREEN

Communication link has been


established over optical fiber

Video signal is present on the


channel.

Contact input is closed.

RED

Communication link has not


been established.

Video signal is not present on the


channel.

OFF

Unit powered down.

Unit powered down.

Contact input is open.

* Contact Closure channels are not operational when used with the FVT1(M,S)1/M transmitters.

TECH SUPPORT: 1.888.678.9427

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
7

INSTALLATION AND OPERATION MANUAL

FVT/FVR10C1(M,S)1[/M], FVR20C2(M,S)2 & FVR40C4(M,S)4


FIGURE A

INSTALLATION CONSIDERATIONS

The FVT10C1(M,S)1/M is supplied as a Standalone/Surface Mount module. Dimensions are for a ComNet FVT10C1/M module
The remaining units covered in this manual are supplied as Standalone/
Rack (ComFIt) modules. Units should be installed in dry locations
protected from extremes of temperature and humidity.
2.2in
(5.5cm)

C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS


CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the
power supply be turned off and that the rack power supply is disconnected
from any power source. Note: Remove electrical connector before
installing in card cage rack.

4.5in
(11.7cm)

1. Make sure that the card is oriented right side up, and slide it into the
card guides in the rack until the edge connector at the back of the card
seats in the corresponding slot in the racks connector panel. Seating
may require thumb pressure on the top and bottom of the cards front
panel.

1.1in
(2.7cm)

CAUTION: Take care not to press on any of the LEDs.


2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:

FIGURE B
Dimensions are for a standard ComNet one slot module
.156 [3.96 mm]

A) Elevated Operating Ambient - If installed in a closed or multiunit rack assembly, the operating ambient temperature of the
rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation of the
equipment is not compromised.

.313 [7.95 mm]

3 CORPORATE DRIVE | DANBURY, CT 06810 | USA


T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
2014 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC.

TECH SUPPORT: 1.888.678.9427

INS_FVTFVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)[M]_REV-

Rev. 06.30.14

PAGE
8

Das könnte Ihnen auch gefallen