Sie sind auf Seite 1von 44

Operating Manual

Refrigerated Compressed-Air Dryer

Air Dryer
FR005AP
FR010AP
FR020AP
FR030AP
FR050AP
FR075AP
FR100AP

FR005A
FR010A
FR020A
FR030A
FR050A
FR075A
FR100A
FR150A

z This Air Dryer is designed for


industrial use. Handle with care.
z Please read this manual carefully
and operate this equipment
accordingly.
z Retain this manual for future
Reference.

Ver.071203

Thank you for your purchase.


Thank you for purchasing this Fu Sheng Co., Ltd product.
To ensure safe and efficient use, please install and operate this equipment in
accordance with the instructions provided in this manual.
Product specifications are subject to change without notice. Please be aware that
recent changes to product specifications may not be reflected in the content of
this manual.

Important Notes...................................................... 1(1)


Names of Parts and Functions..........................................

2(1)

1Appearance.................................................. 2(1)
2Control panel................................................

2(1)

3Switch board................................................. 3(1)


Installation Notes.....................................................

4(1)

1Checking Model.............................................. 4(1)


2Space for Installation.......................................... 5(1)
3Forbidden places.............................................. 5(1)
Preparation for Operation.............................................

6(1)

1Piping....................................................... 6(1)
2Installation of Accessories....................................... 7(1)
3Wiring........................................................ 9(1)
Operation............................................................ 10(1)
1How to Start.................................................. 10(1)
2How to Stop.................................................. 11(1)
Safety Devices......................................................... 12(1)
Daily Maintenance and Checks........................................... 13(1)
1Daily Checks................................................... 13(1)
2Maintenance................................................... 13(1)
1Cleaning of Condenser...................................... 13 (1)
2Cleaning of Auto Drain Trap(ET3000 4000).................... 14(1)
3Cleaning of Auto Drain Trap(AD-5) .......................... 15(1)
Troubleshooting....................................................... 16(1)
AfterSale Service.................................................... 16(1)
Before Long Disuse.................................................... 17(1)
Table of Specifications.................................................. 18
Specification.......................................................... 20

Part list............................................................ . 30

Important Notes.
1. Do not carry the dryer turned aslant or upside

2. Be sure to ground the unit to prevent electric

down

shock.

3. Do not modify the wiring in the switchboard

4Before inspection, be sure to stop the air

Do not modify the wiring except at the

compressor and turn off power to the air dryer.

primary-side power terminals.

Make sure that pressure is reliefed in the


air dryer.

5Never turn the operation switch on and off


frequently.

1(1)

Names of Parts and Functions


Illustrations used are those of FR020A

1. Appearance
Air Outlet
Dry compressed air outlet.

Air inlet
Wet compressed air inlet

Control Panel
Power Cord Hole

Lead the power cord out


from here.

Leg
Use the aperture to fix
this device in place.

2. Control Panel
FR005AFR005APFR010AFR010AP
EVAP. Pressure Gauge
Indicates the EVAP. Pressure of the
FR005AFR005AP

Operation Switch (with lamp)


Press ON, and the lamp lights up, the dryer starts
operating. Press OFF, and the lamp goes out, the
dryer stops

FR010AFR010AP

FR020A~075AFR075AP~100AP

1 ALARM

LAMP

2 RUNNING

3 STOP

4 START

LAMP

SWITCHRED
SWITCH (WHITE)

5 REMOTE/LOCAL

2
3
4

6 AIR

SWITCH

PRESSURE GAUGE

7 EVAP.

PRESSURE GAUGE

8 COND.PRESSURE

2(1)

GAUGE

3.Switchboard

Terminal

Earth

FR010AP
FR020A

FR020AP~050AP
FR030A~075A

Terminal

FR100A 075AP

Terminal

3(1)

Earth

FR150A 100AP

Earth

Earth Terminal

Installation Notes
1. Checking Model
After unpacking the dryer, check the Specifications Plate to make sure that you have received
the system that you ordered..

Accessories

FR005AP 010AP 020AP 30AP050AP


FR005A 010A 020A FR030A 050A 075A
FR075AP 100APFR
FR100A 150A

Auto drain trap

Ball valve

Float type 1pc

1/2B 1pc

Discus type 1pc

1/2B 1pc

Also confirm that the unit has not suffered any shipping-relating damage. In the event of a
problem, please contact your dealer

4(1)

2. Space for Installation


Locate the dryer with enough free space around.
To ensure a sufficient ventilation and accessibility, keep adequate distances
between the dryer and objects in its surrounding

Space for ventilation


60cm or more

Side space
60cm or more

Space for ventilation


60cm or more

Side space
60cm or more

3. Forbidden places
Do not install in the place where unit will
be exposed to direct sunlight, rain, or
external heat. Such exposure may reduce
the ability of the condenser to release heat,
resulting in poor performance.

Ambient temperature should be between 2


and 40. Ambient temperatures above
40. can impede heat release from the
condenser, resulting in safety-device
activation and equipment shutdown. If you
need to install the unit in an area where
ambient temperature may exceed 40 , set
up ductwork as necessary to supply outside
air directly to the air intake area on the
cabinet, or construct an outdoor exhaust
port to discharge the inside exhaust air
(warm air). Be sure that the design does
not result in a drop in the fan airflow.
Do not install in a dusty location.
Dust accumulation on the condenser may
reduce the units performance

5(1)

Preparation for Operation


1. Piping
Air inletoutlet connection dimension
Model

FR005AP

Model
Pipe size

FR005AFR010A
1/2B

FR010AP015AP
020AP
FR020A030A
1B

FR030AP
050AP
FR050A075A
1-1/2B

FR075AP

FR100AP

FR100A
2B

FR150A
2 1/2B

.
Piping notes
Suspend By-pass circuit Check valve Heat Insulator
AIR INLET

AIR OUTLET
When providing a
riser in piping

Inclination

Valve or drain trap


Compressor Chamber

Inside

1Do not confuse the inlet and outlet of the air dryer.
2Do not use any riser in the piping from air compressor to air dryer
However, if it is inevitable, install a valve or a drain trap so that water can be purged
3Provide a by-pass circuit between the inlet and the outlet of the air dryer
4Do not allow the piping weight to bear on the air dryer
5In a cold place, cover the outdoor piping, if any, with heat insulator
Even indoors, use heat insulator if the air dryer outlet piping develops condensation.
6In piping, prevent dust and other foreign materials from entering the air circuit

6(1)

2. Installation of Accessories
1) FR005AP010AP020AP030A050AP
FR005A010A020A030A050A075A
Accessories
Auto drain trap
Ball valve
Auto drain trap

Float type

1/2B
Float type

1pc
1pc
1pc

1) As shown, install the ball valve and auto drain trap on the drain pipe with the marking
DRAIN .
2) After the installation, open the ball valve.
3) Install the auto drain trap so that the drain outlet is positioned below.
4) Use the following vinyl hose when the drainage is to be led out of the auto drain trap.
Hose inside diam.:16 mm
5) When connecting a pipe, screw it on the threaded part of the drain trap outlet.
Drain trap outlet thread diam: Rc 1/4
Important
To remove the drain trap (when you need to replace it), proceed as follows:
(1) Close the ball valve;
(2) Release the pressurized air from the trap;
(3) Hold on to the ball valve so that it cannot turn, and rotate (unscrew) the trap to remove.

Important
If attaching a pipe to the drain outlet, note that the pipe should not be too long and should not
move upward. Reverse pressure caused by excessive pipe length or upward flow may prevent
draining.

7(1)

2) FR050AP075AP100AP
FR050A075A100A150A
Accessories
Auto drain trap

Discus type

1 pc

Ball valve

1/2B

1 pc

Important
To remove the drain trap (when you need to replace it), proceed as follows:
1) Close the ball valve;
2) Release the pressurized air from the trap;
3) Hold on to the ball valve so that it cannot turn, and rotate (unscrew) the trap to remove.
Important
If attaching a pipe to the drain outlet, note that the pipe should not be too long and should not move
upward. Reverse pressure caused by excessive pipe length or upward flow may prevent draining.

8(1)

3. Electrical Wiring
1) Power-cord capacities are as follows.
Model
Power source
(standard type)
Power cord (mm2)
Breaker capacity (A)
Ground line (mm2)

FR005AP010AP020AP FR030AP FR050AP FR075AP100AP


FR005A010A020A030A FR050A
FR075A
FR100A150A
Single phase 220V
3 phase 220V 50/60Hz
50/60Hz
1.25 or more
2.0 or more
10A
20A
1.25 or more
2.0 or more

2) Install an overload leakage breaker (overload-protect function plus current leakage


function).
The breaker must be dedicated to the air dryer. (Use high-speed type with 30mA
current sensitivity.)
3) Connect up the power cord.
For single-phase models, connect the wires to terminals 1 and 2.
For three-phase models, connect to terminals R,S and T
4) Connect the ground.
Ground (earth) connection must be set up by a qualified electrician. The ground line
must be connected to the earth terminal. The line diameter must be at least 2mm2.
5) Power voltage should remain within 5% of the rated value while the dryer is operating.

9(1)

Operation
Before starting operation, make certain that the power breaker is ON

1How to start
c Press the operation switchON
The operation lamp lights up and operation starts
FR005AP

FR010AP above

FR005A010A

FR020AP

d 3 minutes later, start supplying compressed air


About three minutes after the start of the dryer, supply compressed air by operating
the air compressor

Close

Open

Caution

By-pass valve

Open

At this time, be sure to close the by-pass valve in the piping

10(1)

e Check the indications on the gauges.


Soon after the flow of compressed air, EVAP. pressure gauge will normally start indicating within the
green-colored range
EVAP. pressure gauge
The air dryer may not easily develop trouble even when it is operated with the EVAP. pressure
gauge indicating a little beyond the green range. Yet, take care to use it within the green range
so that the dryer can perform at its maximum efficiency
Green range

Note When the ambient temperature drops, the fan may repeat stop and run operationThis is
to prevent the freezing inside the heat exchanger

2How to Stop
c Stop the air compressor
d Press the stop switch OFF
The operation lamp goes out and operation stops

11(1)

Safety Devices
The dryer is provided with safety devices to ensure operational safety for you
The air dryer will stop automatically at the operation of any safety device
Refrigerant circuit safety device ) High-pressure switch
The high-pressure switch operates when the condensation pressure reaches:
3.00.1MPa (301kgf/cm2G) (R407CRefrigerant)
2.0 0.1MPa (201kgf/cm2G) (R134aRefrigerant)
and stops the dryer
Electric circuit ) Motor protector
The motor protector will operate to stop the air dryer if the temperature of the compressor gets
high or an over current flows in the circuit.

How to reset
1Remove the cause of stoppage.See Troubleshooting
2Press the operation switch ON on the control panel.

12(1)

Daily Maintenance and Checks


1. Daily Checks
Checking of auto drain trap
Check the auto drain trap everyday.

Check items
Air leakage
Normal operation
(water draining)

No air
leakage

Water
draining

2. Maintenance
1Cleaning of condenser
Clean the condenser periodically, using a brush or air gun

Dust or dirt accumulated on the condenser


will reduce the heat exchange efficiency
At the worstthe dryer may stop with the
safety device operating

Caution

In cleaning, exercise care so as not to deform the condenser fins

13(1)

2) Cleaning of auto drain trap (Float type)


.

Overhaul the auto drain trap periodically


NO.
1
2
3
4
5
6
7
8
9
10
11
12
13

(every week) so that it can always operate normally.

PARTS NAME
Plat cover
Body
O-ring
Filter
Bowl
Bowl guard
Float
Orifice
Float level arm
Spring
Packing
Valve
Orifice spring

How to clean
(1) Close the ball valve.
(2) Remove the dirt and dust from the filter element, which is fit in the lower part of the auto
drain unit, using an air gun or like means.
(3) Wash the separated parts with a neutral detergent.
(4) Check for damaged parts. Make a particularly careful check of O-ring.
(2) Caution
Never disassemble the auto
drain unit. Otherwise
troubles will result.

(3)

(4)

The drain should not be exposed to direct sunlight, as such exposure may damage the drain
bowl.
The following substances can damage the drain bowl. These substances should never be
present within the drain or in the atmosphere around the drain.
Oils based on phosphoric acid esters.
Organic solvents (aromatic, chloride, and hydrocarbon compounds)
Benzene, toluene, phenol, trichloroethylene, gasoline, paint thinner, etc.
Sulfurous acid gas, chorine gas, CFC gas.
Acids: hydrochloric acid, sulfuric acid, acetic acid, etc.

14(1)

3) Cleaning of auto drain trap ( Discus type )


Overhaul the auto drain trap periodically (every week) so that it can always operate normally.
Parts name

Draining
Discharge the drainage once a week by turning the drain plug clockwiseDuring a
cold season, perform the drainage after every operation to prevent freezing
Draining before a long suspension of operation
Be sure to discharge the water from the bowl by turning "clockwise" the drain plug
at the bottom of the drain trap
Adjustment of drainage discharge
The operating interval of this drain trap varies with the load, pressureetc
Turning the needle valve in the ""direction will shorten the interval and increase
the drainage dischargeAdjust the interval in such a way that water will not
accumulate in the bowl
Disassembly
If some abnormality, such as excessive dirt on the screen or longer interval, is found,
overhaul the drain trap as follows
Turn the cap counterclockwise and remove it
Blow the dust off from the filter, using compressed air
Clean the disc cap and disc
Turn the ring counterclockwise and remove it.
Remove the screen
Blow the dust off the screen
Wash the bowl with a neutral detergent. Never use any organic solvent
Check all the parts for damage. Never fail to check the O-rings, packings and washer

15(1)

Troubleshooting
Should any trouble arise during operation of the dryer, correct it using the troubleshooting chart
below
Problem
Dryer does not operate with
operation switch ON
pressed
(RUN lamp does not light up.)

Possible Cause
Lamp disconnected
Switch faulty
Low power supply voltage
Magnetic contactor faulty
Protector faulty
High pressure switch faulty
Dryer does not operate with Magnetic contactor faulty
operation switch ON pressed Protector fault
(RUN lamp lights up.)
Dew point is normal but
Drainage hindered by foreign
water or oil drops occur
material in auto drain trap
Drainage in auto drain trap frozen

Solution
Replace.
Replace.
Use specified voltage.
Replace
Replace
Replace.
Replace
Replace

Disassemble and clean


auto drain trap
Take proper measures to
prevent freezing
Dew point is high and water Too high air processing rate
Correct air processing
or oil drops occur
rate
Lowered cooling capacity
Check for gas leak
Condenser clogged up
Clean
Too high ambient temperature
Lower ambient
temperature.(below 40
)
Fan motor faulty
Replace
Machine stops suddenly
Replace
Magnetic contactor faulty
during operation
Too high air processing rate
Correct air processing
rate
Condenser clogged up
Clean
Too high ambient temperature
Lower ambient
Abnormal voltage
temperature. (below 40
)
Fan control pressure switch faulty Use rated voltage
Replace

After-Sale Service
Should any trouble arise, correct it according to the troubleshooting chart If you can not
correct it, contact your dealer and ask for the repair. When you request an after-sale service on
the dryer, give information on the following particulars
Application for repair
Application for parts
(1) Model and Serial Noof the air dryer
(1) Model and Serial Noof the dryer
(2) Defective part and trouble
(2) Number, name and quantity of part(s)
(3) Date of purchase
(4) Sketch map of your location

16(1)

Before Long Disuse


1. Turn off the power
Turn off the main power supplypower supply
breaker

2. Purge drainage out


Discharge the drainage inside the air dryer
completely through the auto drain trap.

3. Store
Store the air dryer in a place free from dirt,
dust, rain, water, snow, etc

For operation after a long disuse


Perform checks of the parts of the air dryer. Then resume operation according to the
instructions on preparation and operation in this manual

17(1)

Table of Specifications

Model

FR

Measurement conditions on air processing

Air processing capacity


3
m / min

Inlet air pressure


MPa

Inlet air temperature

Dew point of outlet air

Ambient temperature

Allowable conditions

Maximum inlet air temperature

Ambient temperature

Maximum air pressure


MPa

External dimensions

Height
mm

Depth
mm

Width
mm

Net weight
kg

Air pipe connection


B

005A

010A

020A

030A

050A

075A

100A

150A

0.6

1.2

2.4

4.4

7.0

11.0

14.0

23.5

0.69
35
-17 at atmosphere
17
32

10

50

40

0.2

0.98

478

542

705

705

966

1166

1220

1260

490

423

423

440

490

490

984

1022

377

722

797

797

944

944

696

792

22

34

42

42

70

88

105/95

180

R 2

R 2-1/2

R 1/2

R 1

R 1-1/2

Electric rating

Power source

Power consumption

Electric current

Equipment details

Evaporator

Condenser

Fan motor for condenser

Refrigerant controller

Capacity controller

Refrigerant

Auto drain trap

1220V 50/60Hz
220V 50/60Hz
kW

0.25/0.3

0.4/0.5

0.6/0.7 0.8/0.9 1.6/1.7 1.6/1.7

2.2/1.7

1.3/1.5

2.0/2.3

2.7/3.3 4.1/4.5 6.0/6.7 6.3/7.5

8.0/6.8 12.0/12.5

Cross - wave fin type (Shell : SUS304)


(:SUS304)
Fin and tube, forced air cooling
Parallel flow condenser ,forced air cooling

/W

120/40

230/40

250/40

300/40

350/100

400/250

3.4/4.1

Fin and tube

500/400

Capillary tube system

Capacity control valve

R134a

R407C
Float type

Over current relay

Protecting devices

Compressor

Fan motor for condenser

Refrigerant circuit

3220V50/60Hz
220V50/60Hz

Discus type

Opposite phase relay

Thermostat

Fan motor over temp. switch

High pressure switch

Cooling fan control switch

18

Table of Specifications

Model
FR

Measurement conditions on air processing

Air processing capacity


3
m / min

Inlet air pressure


MPa

Inlet air temperature

Dew point of outlet air

Ambient temperature

Allowable conditions

Maximum inlet air temperature

Ambient temperature

Maximum air pressure


MPa

External dimensions

Height
mm

Depth
mm

Width
mm

Net weight
kg

Air pipe connection


B

005AP

010AP

020AP

030AP

050AP

075AP

100AP

0.6

1.2

2.4

4.4

7.0

11.0

14.0

0.69
55
-17 at atmosphere
17
32

10

80

40

0.2

0.98

542

705

705

966

1166

1214/1220

1260

423

423

440

490

490

1022/973

1022

722

797

797

944

944

792/670

792

34

42

42

70

88

175/105

180

R2

R2-1/2

R1/2

R1

R1-1/2

Electric rating

Power source

Power consumption

Electric current

Equipment details

Evaporator

Condenser

Fan motor for condenser

Refrigerant controller

Capacity controller

Refrigerant

Auto drain trap

1 phase 220V 50/60Hz


220V 50/60Hz
kW

0.4/0.5

0.6/0.7

0.8/0.9

1.6/1.7

1.6/1.7

3.4/2.6

3.8/4.1

2.0/2.3

2.7/3.3

4.1/4.5

6.7/7.0

6.7/7.7

12/7.5

12.0/12.5

Cross - wave fin type (Shell : SUS304)


(:SUS304)
Parallel flow condenser ,forced air cooling
Fin and tube, forced air cooling

500/400
/W
230/40
250/40
300/40
350/100
400/250
Capillary tube system

Capacity control valve

R134a

Discus type

Thermostat

High pressure switch

Cooling fan control switch

19

500/400

Opposite phase relay

Fin and tube

R407C
Float type

Over current relay

Protecting devices

Compressor

Fan motor for condenser

Refrigerant circuit

3phase220V50/60Hz
220V50/60Hz

Fan motor over temp. switch

Specifications
FR005A
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

20

Diagram

FR005AP FR010A
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

21

Diagram

FR010AP FR020A
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

22

Diagram

FR020AP FR030A
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

23

Diagram

FR030AP FR050A
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

24

Diagram

FR050AP FR075A
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

25

Diagram

FR100A60Hz
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

26

Diagram

FR075AP60Hz FR100A50Hz
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

27

Diagram

FR100AP

FR150A

Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

28

Diagram

FR075AP50Hz
Overall Dimensions(unit : mm)

Circuit

Wiring

Diagram

29

Diagram

PARTS LIST
FR005A

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

PART NAME
AUTO DRAIN TRAP
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
MOTOR PROTECTOR
HOOD
CONDENSER
FAN
FAN CONTROL
HEAT EXCHANGER
REFRIGERANT STRAINER
BASE
PANEL
RIGHT SIDE PANEL
LEFT SIDE PANEL

PRESSURE GAUGE 50
GAUGE FITTING
CORRUGATED SWITCH
OPERATION PLATE FILM
RUNNING CAPACITOR

50

30

SPECIFICATION
DT3000
111TP
CGX-2315DM
GL45TG
MRA-5758
1X8X240
S109AP-11-1
ACB-0905
RAX-3B
9G
LGHC
EGC-B
EGC-B
EGC-B
6123-0900-00
LGHC
3035-POT2B01RDBK
TETRONIC FILM
47MF

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

FR005AP

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

FR010A

PART NAME
AUTO DRAIN TRAP
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
MOTOR PROTECTOR
STARTING RELAY
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HEAT EXCHANGER
REFRIGERANT STRAINER
BUSH
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
PRESSURE GAUGE 50
GAUGE FITTING
CONTROL PANEL
CORRUGATED SWITCH
OPERATION PLATE FILM

50

31

SPECIFICATION
DT3000
111TP
CGX-2315DM
AEZ4430Y
MRT56AMK
0012-45 437
2-10-245-O
230D (9")
230D (9")
12"
ACB-0905
RAX-6B
9G
20
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
6123-0900-00
LGHC 2.3T
EGC-B
3036-POT2801ROBK
TETRONIC FILM

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

FR010AP

No.
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
25
26
27
29
30
31
32
33
34
35
36
37
38
39

FR020A

PART NAME
AUTO DRAIN TRAP
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
MOTOR PROTECTOR
STARTING RELAY
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
HEAT EXCHANGER
REFRIGERANT STRAINER
BUSH
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
SWITCH BOARD COVER
STARTING CAPACITOR
PRESSURE GAUGE 50
PRESSURE GAUGE 50
BUSH
FIXED METAL A
PILOT LAMP
PUSH BUTTON SWITCH
PUSH BUTTON SWITCH
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNETIC CONTACTOR
SWITCHBOARD HOOD
SWITCHBOARD BASE

50
50

32

SPECIFICATION
DT3000
111TP
CGX-2315DM
CAE4440Y
MRP36AMK
5645 514
3-11-330-O
250D (10")
250D (10")
12"
ACB-0905
DB92

20
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
64MF
6123-0900-00
M500-04-2084
30
LGHC 2.3T
NB-281PGF AC220V
P13-1B(WHITE)
P13-1C(RED)
TETRONIC FILM
EGC-B
TB112F 3P
S-C11 AC220V
EGC-B

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1

FR020AP

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

FR030A

PART NAME
AUTO DRAIN TRAP ASSY.
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
THERMOSTAT
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
REFRIGERANT STRAINER
HEAT EXCHANGER
BUSH
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
SWITCH BOARD COVER
PRESSURE GAUGE 50
PRESSURE GAUGE 50
FIXED METAL A
PILOT LAMP
RUNNING CAPACITOR
ON-PUSH BUTTON SWITCH
OFF-PUSH BUTTON SWITCH
STARTING CAPACITOR
STARTING RELAY
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNETIC CONTACTOR
SWITCHBOARD HOOD
SWITCHBOARD BASE
TERMINAL BLOCK
SWITCHBOARD FIXED METAL
CABLE CONNECTOR

50
50

33

SPECIFICATION
DT4000
1/2" T201-04BTP
SPX-4540DH
KE-C122QZ (1,220V 50/60Hz)
1NT001L-4663
0A00048720(PC114)
300D (12") (50,75,100)(6 )
300D (12") (50,75,100)
KAF12142 (1,220V 50/60Hz)
ACB-2114A
ACB-2330
1/41/4 2.4 (18.85t0.7)
02090149040 RAX22F
30
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
0-1.5MPa
6123-0914-00
LGHC 2.3T
NB-281PGF AC220V
17F400VAC
P13-1B (WHITE)
P13-1C (RED)
14.7uF
TETRONIC FILM 0.125T
EGC-B
TB112F 3P
S-C12D10G7 (220V)
EGC-B
TB112F 3P 25A
EGC-B
20

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
1
1
1

FR030AP

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39

FR050A

PART NAME
AUTO DRAIN TRAP ASSY.
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
THERMOSTAT
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
COPPER PIPE STRAINER
HEAT EXCHANGER
CABLE CONNECTOR
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
SWITCH BOARD COVER
PRESSURE GAUGE 50
PRESSURE GAUGE 50
BUSH
FIXED METAL A
PILOT LAMP
Opposite phase relay
PUSH BUTTON SWITCH
PUSH BUTTON SWITCH
TERMINAL BLOCK
ELECTROMAGNETIC CONTACTOR
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNETIC CONTACTOR
SWITCHBOARD HOOD
SWITCHBOARD BASE
SWITCHBOARD FIXED METAL

50
50

34

SPECIFICATION
Q'TY
DT4000
1
1/2" T201-04BTP
1
SPX-4540DH
1
KFPC262QZFC-F(3220V 50/60Hz)
1
1NT001L-4663
1
0A000489010(PC115)
1
350D (14")
1
350D (14")
1
YWF-4D-350D(14")
1
ACB-2114A
1
ACB-2330
1
FS1033-35(3/8")
1
02090342030 (RAX37F)
1
20
1
LGHC
1
EGC-B
1
EGC-B
1
EGC-B
1
EGC-B
1
EGC-B
1
EGC-B
1
EGC-B
1
0-1.5MPa
1
6123-0914-00
1
30
2
LGHC 2.3T
1
NB-281PGF AC220V
1
APR-3
1
P13-1B(WHITE)
1
P13-1C(RED)
1
TB112F 3P 25A
1
MSO-C12 220V NTH-11 11A
1
TETRONIC FILM
1
EGC-B
1
NHC-10-3P
1
S-C11 220V
1
EGC-B
1
EGC-B
1
EGC-B
1

FR050AP

No.
1
2
3
4
5
6
7
8
9
10
11
14
15
16
17
18
19
20
21
22
23
24
25
26
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44

FR075A

PART NAME
AUTO DRAIN TRAP ASSY.

BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
THERMOSTAT
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
COPPER PIPE STRAINER
HEAT EXCHANGER
CABLE CONNECTOR
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
SWITCH BOARD COVER
PRESSURE GAUGE 50
PRESSURE GAUGE 50
BUSH
FIXED METAL A
PILOT LAMP
RUNNING CAPACITOR
PUSH BUTTON SWITCH
PUSH BUTTON SWITCH
STARTING CAPACITOR
STARTING RELAY
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNETIC CONTACTOR
SWITCHBOARD HOOD
SWITCHBOARD BASE
ELECTROMAGNETIC CONTACTOR
Opposite phase relay
TERMINAL BLOCK

50
50

35

SPECIFICATION
DT4000
1/2" T201-04BTP
WPR-1004DH-Q10
KFPC262QZFC-F(3,220V)
1NT001L-4663
0A000491020(PC116)
350D (14")
350D (14")
YWF-4D-350D(14")
ACB-2114A
ACB-2330
FS1033-35
02090348020 RAX55F
20
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
0-1.5MPa
6123-0914-00
30
LGHC 2.3T
NB-281PGF AC220V
25MF
P13-1B (WHITE)
P13-1C (RED)
88MF
RVA 2AE 3D
TETRONIC FILM
EGC-B
TB-112F 3P
S-C12 AC220V
EGC-B
MSO-C12 220V NTH-12 11A
APR-3
NHC-10-3P

Q'TY
1
1
1
1
1
1
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
0
0
1
1
1
1
1
1
1
1
1

FR100A(50Hz) FR075AP

No.
1
2
3
4
5
6
7
8
9
10
12
13
15
16
17
18
19
20
21
22
24
25
26
27
28
29
30
31
32
33
34
37
38
39
40
41
42
43
44
45
46
47

PART NAME
AUTO DRAIN TRAP ASSY.
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
COPPER PIPE STRAINER
HEAT EXCHANGER SET
CABLE CONNECTOR
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
PRESSURE GAUGE 50
PRESSURE GAUGE 50
BUSH
FIXED METAL A
PILOT LAMP
PUSH BUTTON SWITCH
PUSH BUTTON SWITCH
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNET SWITCH
SWITCH BOARD HOOD
ALARM LAMP
WAVY SWITCH
PRESSURE GAUGE 50
TERMINAL BLOCK
MAGNETIC CONTACTOR
Opposite phase relay
RELAY SOCKET
RELAY
RELAY SOCKET
RELAY

50
50

()

50

36

SPECIFICATION
AD-5
1/2" T201-04BTP
WPR-1004DH-Q10
TFH-5524 (3 220V) 60Hz
0A000491020(PC116)
400D (16")
400D (16")
YWF-4D-400D(16")
ACB-2114A
ACB-2330
FS1033-35 (3/8)
02090653020 RAX 120F
20
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
0-1.5MPa
6123-0914-00 1.5MPa
30
LGHC
NB-281PGF AC220V
P13-1B (WHITE)
P13-1C (RED)
TETRONIC FILM
LGC
TB112F 3P 25A
MSO-C12 220V NTH-11
LGC
NB-281 PRF AC220V(RED)
SLE6D2 4A 250V
GK25-S27(6113-0010-00) 0-3MPa
NHC-10-8P
S-C12 AC220V 1a
APR-4
PF085A
BMY-2C 5A 240V 0516B / K1 /1a1b
PYF-08A
AMY-2 5A 250VAC / 2a

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
3
3
0

FR100A (60Hz)

No.
1
2
3
4
5
6
7
8
9
10
12
13
15
16
17
18
19
20
21
22
24
25
26
27
28
29
30
31
32
33
34
37
38
39
40
41
42
43
44
45
46
47

PART NAME
AUTO DRAIN TRAP ASSY.
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
COPPER PIPE STRAINER
HEAT EXCHANGER SET
CABLE CONNECTOR
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
PRESSURE GAUGE 50
PRESSURE GAUGE 50
BUSH
FIXED METAL A
PILOT LAMP
PUSH BUTTON SWITCH
PUSH BUTTON SWITCH
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNET SWITCH
SWITCH BOARD HOOD
ALARM LAMP
WAVY SWITCH
PRESSURE GAUGE 50
TERMINAL BLOCK
MAGNETIC CONTACTOR
Opposite phase relay
RELAY SOCKET
RELAY
RELAY SOCKET
RELAY

50
50

()

50

37

SPECIFICATION
AD-5
1/2" T201-04BTP
WPR-1004DH-Q10
KFPC262QZFC-F (3 220V)
0A000491020(PC116)
400D (16")
400D (16")
YWF-4D-400D(16")
ACB-2114A
ACB-2330
FS1033-35 (3/8)
02090653020 RAX 120F
20
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
0-1.5MPa
6123-0914-00 1.5MPa
30
LGHC
NB-281PGF AC220V
P13-1B (WHITE)
P13-1C (RED)
TETRONIC FILM
LGC
TB112F 3P 25A
MSO-C12 220V NTH-11
LGC
NB-281 PRF AC220V(RED)
SLE6D2 4A 250V
GK25-S27(6113-0010-00) 0-3MPa
NHC-10-8P
S-C12 AC220V 1a
APR-4
PF085A
BMY-2C 5A 240V 0516B / K1 /1a1b
PYF-08A
AMY-2 5A 250VAC / 2a

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
0

FR100AP FR150A FR075AP(50Hz)

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
37
38
39
40
41
42
43
44
45

PART NAME
AUTO DRAIN TRAP ASSY.
BALL VALVE
CAPACITY CONTROL VALVE
BARE COMPRESSOR
CONDENSER
FAN
FAN GUARD
MOTOR
FAN CONTROL
HIGH PRESSURE SWITCH
COPPER PIPE STRAINER
HEAT EXCHANGER
HEAT EXCHANGER
ACCUMULATOR SET
BUSH
BASE
RIGHT FRONT PANEL
RIGHT SIDE PANEL
REAR PANEL
LEFT FRONT PANEL
LEFT SIDE PANEL
UPPER PANEL
PRESSURE GAUGE 50
PRESSURE GAUGE 50
PRESSURE GAUGE 50
BUSH
FIXED METAL A
PILOT LAMP
PUSH BUTTON SWITCH
PUSH BUTTON SWITCH
OPERATION PLATE FILM
CONTROL PANEL
TERMINAL BLOCK
MAGNETIC CONTACTOR
MAGNET SWITCH
ALARM LAMP
SWITCH BOARD BASE
TERMINAL BLOCK
RELAY
TIME RELAY
RELAY SOCKET
TERMINAL BLOCK
ELECTRIC WIRE DUCT
ELECTRIC WIRE DUCT

50
50
50

SPECIFICATION
AD-5
111TP
CTX-12220DPQ105
3220V TFH5538C
520545-D
20
20
20
ACB-2114A
ACB-2330
DML083
TRX-150
TRX-100B
KF70WLE1D
30
LGHC
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
EGC-B
GK25-S27(6113-0005-00)
6123-0914-00 1.5MPa
GK25-S27(6113-0010-00) 0-3MPa
30
LGHC
AC220V()
(WHITE)
(RED)
TETRONIC FILM
EGC-B
TB-30 (3P)
C-12D 1NO1NC 220V
C-18D 1NO1NC 220V GTH-11/3 11A
AC220V()
EGC-B
NHC-10-8P
MY2 AC220V/240V
H3Y-2 220V 5SEC
PYF08A
NHC-10-11P
HD-1-L607
HD-1-L247.5

38

Q'TY
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
2
1
1
1
1
1
2
1
3
1
2
2

Q'TY(075AP)
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
2
1
1
1
1
1
2
1
3
1
2
2

Fu Sheng Industrial Co., Ltd. Machinery Division


No. 60 Kwang Fu Road, Sec. 2 San Chung City 241, Taipei County, Taiwan
Tel : 886-2-2995-1411 Fax : 886-2-2995-7925
Headquarter
No. 172 Nanking East Road, Sec. 2,Taipei, Taiwan, R.O.C