Commissioning
2.1. Settings to be made before login
Go to Control Panel Go to Network Connections Go to LAN Properties
Go to TCP/IPv4 Click on Obtain IP address automatically

2.2. LCT Start-up and Login


Physical Connection
Web Login
Straight Cable
LCT Port

URL-http://172.17.254.253/

User Name Admin


Password - 12345678

Press OK

Start the browser Internet Explorer and enter the URL


http://172.17.254.253/ to open the Web LCT
Login screen.
Enter the User Name and Password in the provided text boxes and Click Ok button
Default Username: Admin
Password: 12345678
LCT main menu opens in the Current Status screen

LAN Port

2.3. Web LCT Initial Screen

Equipment Configuration
Radio Configuration
AMR/Radio Mapping
Network Management Configuration
E1/STM-1/Cross Connect Setting

Current Metering

2.4. Equipment Configuration

Enter Site ID as mentioned in LB


as

2.5. Radio Configuration


Enter Radio Parameters as shown in the Image below.

Channel Spacing28MHz
Reference ModulationQPSK
Radio Mode-High Capacity
TX RF Frequency-As per LB
Frame ID - 1
TX Power Control - ATPC

After Filing all the Parameters


Press Next

Press OK

Press OK

Press OK

2.6. AMR Settings


Select AMR Operation as - Non Operation
st

Enter number of E1 as
required

2nd

Select Non Operation

Press Next

Press Next

4th

3rd

Press OK

Press OK

Press OK

2.7. Network
Management
Enter IP Address
(As mentioned in LB),
Subnet Mask
& Default gateway as
shown in the Image.

2.8. TX Power
Enter TX Power(as per LB) as shown in the Image below.

2.9. Antenna Alignment


Connect multi-meter pins to AGC port of ODU & grounding to check the desired
reading on multi-meter(Keeping the multi-meter Knob on 20V)
Adjust the direction of Antenna, so as to get multi-meter reading approx. 3.95 Volts.
Repeat the above point at Far end to get the desired RX Level (Check in Metering).

2.10.

E1 Port Settings

Select CH Usage as Used All


Select Impedance as All CH 120(Ohms)

Press OK

2.11.

E1 Cross connect Settings

Click on Add Give Service Name Cross Connect type E1


On Edge A Select Mainboard (Select number of E1 to be used)
On Edge B Select Modem1 (Select number of E1 to be used) and click ok.

Edge A Select Mainboard


Edge B Select Modem1

Select 1 to N in Edge A (by pressing shift + down Arrow Key)


Select 1 to N in Edge B (by pressing shift + down Arrow Key)
Press OK

N = Number of E1 required

2.12.

Equipment Clock Setting

Equipment CLK settings to be made at MUX end

Setting at MUX END


Sync ETH Disabled
Equipment CLK Mode - Slave
Sync ETH Disabled
Timing source E1 Line CLK
Port/CH CH01
Priority Level - 1

Setting at BTS END

Equipment CLK settings to be made at BTS end

Sync ETH Disabled


Equipment CLK Mode - Slave
Sync ETH Disabled
Timing source MODEM
Port/CH Port01
Priority Level - 1

The Physical Installation & Commissioning at near end is complete.

Repeat Steps 1.1 to 2.12 at Far End

3. E1 Patching
3.1. E1 punching on DDF
CH-1 to CH-8 TX

CH-9 to CH-16 TX

Prepare PCM Cable according to the


Colour Code mentioned below.
DDF should be installed as per Customer instruction.
Connect MDR Cable/Y Cable with the PCM Cable.
Labelling(CH number & towards XX)
on DDF Crone is compulsory.
CH-1 to CH-8 RX
CH-9 to CH-16 RX

NEC DDF
Connection with IDU

MDR Cable / Y-Cable

PCM Cable

Connection of Y-Cable & PCM Cable

3.2. Extending E1 from Customer MUX to NEC DDF


We need to identify the E1 details provided by Customer
Identify the Tx of MUX E1 with LED
Accordingly punch the E1 & extend it to NEC DDF.

3.3. Colour Coding for PCM Cable


E1
RX8
RX7

NEC Standard Colour code II


WHITE
BLUE
WHITE
ORANGE
GND

RX6
RX5

WHITE
GREEN
WHITE
BROWN
GND

RX4
RX3

RED
BLUE
RED
ORANGE
GND

RX2
RX1
TX8
TX7

RED
GREEN
RED
BROWN
BLUE
ORANGE
GND

TX6
TX5
TX4
TX3

GREEN
BROWN
YELLOW
BLUE
YELLOW
ORANGE
GND

TX2
TX1

3.4. Metering at
both ends.
Verify the desired RSL in Metering
as shown in the Image

YELLOW
GREEN
YELLOW
BROWN