Beruflich Dokumente
Kultur Dokumente
SS/AMAS/S_6
AquaMaster S
the next generation integrated
measurement system for water
system management
SS/AMAS/S_6
Typical Applications
District metering
Trunk mains
Treatment works
SS/AMAS/S_6
Logger Facility
The AquaMaster S transmitter also contains a multichannel,
multivariable logger. The ability of the logger to run at two speeds
simultaneously enables the user to investigate, in precise detail,
the flow and pressure activity during a period of interest. This
logger logs both flow and pressure via a direct digital transfer of
data, thereby ensuring optimum accuracy and resolution of
measurement. Graph 1 (below) illustrates actual district network
measurements showing extra detail captured utilizing the twin
loggers. Traditional techniques of counting pulses over a short
logging interval leads to quantization effects corresponding to
whole numbers of pulses on logger graphs which is shown on
Graph 2 (below). AquaMaster S eliminates such effects,
averaging digitally over the selected logging interval. Such high
resolution data facilitates step testing, leak detection and water
network analysis.
30
Flow (l/s)
10
10
Pressure (bar)
20
5
Flowrate 1 min log
Flowrate 15 min log
Pressure 1 min log
Pressure 15 min log
20
30
23:00
2
0:00
1:00
2:00
3:00
4:00
5:00
6:00
Time
18
AquaMaster Integrated Logger
External Logger using pulse output
13
2
22:00
23:00
0:00
1:00
2:00
3:00
4:00
5:00
6:00
SS/AMAS/S_6
Antenna
The AquaMaster is available with either an internal or external
antenna. Having the antenna external to the Transmitter cabinet
or other field enclosure that may be used to house the
Transmitter. The integral antenna version can be used within any
plastic enclosure or in outside locations.
To ensure satisfactory signal reception at the time of
commissioning, AquaMaster can check the signal strength in its
final installed location with the covers/enclosures etc. fitted
and report on its suitability for data transfer.
Base
Station
Base
Station
SS/AMAS/S_6
Support Software
AquaMaster S is compatible with a variety of industry-standard
third party software (Technolog [PMAC], Hydreka Winfluid,
Primayer, OSI PI database and Capula Beaver Valley
[WADIS]) for downloading, managing, analysis and display of
data, either directly from the RS232 port or remotely.
Software
SMS (Text)
ABB
LogMaster
Technolog
(PMAC)
Primayer
OSI PI
Database or
Capula
Beaver Valley
(VVADIS)
Hydreka
(Winfluid)
Automated
Meter
Reading
(via SMS
Gateway)
Mobile
Phone Text
Mobile
Phone
AquaMaster
Log Master
SS/AMAS/S_6
Transmitters
Comprehensive display
Submersible for use in flooded chambers IP68 (NEMA6)
Resetable or secure totals
8mm high displays for totals
(exceeds ISO 4064 requirements)
Total security:
Two user-security levels
Anti-tamper switch and seals
Three outputs
(forward & reverse pulse, or pulses & direction and
alarm)
AquaMaster
88888888 8
m3
gal
ftm3/hMGD
AB 0 .8.8.8.8 gal/sm
Status Indicators
Battery A low
Fault
Empty pipe
Battery B low
Mains off
SS/AMAS/S_6
Tariff A
Tariff B
Day and night during weekend Day and night during week
Tariff A
Tariff B
Foolproof, no errors
Day and night during summer Day and night during winter
SS/AMAS/S_6
5%
ISO 4064 Class C
AquaMaster
Class C
AquaMaster
2%
0.25%
0.25%
2%
Actual AquaMaster
calibration results
5%
Qmin
Class C
AquaMaster
Qt
0.24(1.1)
0.1(0.45)
0.24(1.1)
Q0.25%
80(364)
0.6(2.7)
2(9.1)
Comparison of 80mm (3 in.) AC Performance Specification m3/h (gal/min.) with ISO 4064 Class C
Qmax
80(364)
SS/AMAS/S_6
Specification
Battery-powered Meters Flow Requirements per ISO 4064 (Standard Version)
Size
mm
in.
15
20
25
40
50
65
80
100
150
200
250
300
350
400
450
500
600
/2
/4
1
11/2
2
21/2
3
4
6
8
10
12
14
16
18
20
24
Qmax.
Q (0.5%)
Qt
Qmin.
m3/h (Ugal/min)
m3/h (Ugal/min)
m3/h (Ugal/min)
m3/h (Ugal/min)
m3/h (Ugal/min)
3 (13)
5 (22)
7 (31)
20 (88)
30 (132)
50 (220)
80 (352)
120 (528)
300 (1320)
500 (2200)
800 (3520)
1200 (5280)
1600 (7040)
2000 (8810)
2600 (11450)
3000 (13210)
5000 (22010)
1.5 (7)
2.5 (11)
3.5 (15)
10 (44)
15 (66)
25 (110)
40 (176)
60 (264)
150 (660)
250 (1100)
400 (1760)
600 (2640)
800 (3520)
1000 (4400)
1300 (5720)
1500 (6600)
2500 (11010)
0.23 (1.0)
0.38 (1.7)
0.53 (2.3)
1.5 (6.6)
2.3 (9.9)
3.8 (16.5)
6 (26)
9 (40)
23 (99)
38 (165)
60 (264)
90 (400)
120 (530)
150 (660)
195 (860)
225 (990)
375 (1650)
0.023 (0.099)
0.038 (0.165)
0.053 (0.23)
0.150 (0.66)
0.23 (1.0)
0.38 (1.7)
0.6 (2.6)
0.9 (4.0)
2.3 (10)
3.8 (17)
6 (26)
9 (40)
25 (110)
31 (138)
44 (193)
63 (275)
79 (347)
0.009 (0.040)
0.015 (0.066)
0.021 (0.09)
0.06 (0.26)
0.09 (0.40)
0.15 (0.66)
0.24 (1.06)
0.36 (1.59)
0.9 (4.0)
1.5 (6.6)
2.4 (11)
3.6 (16)
10 (44)
13 (55)
18 (77)
25 (110)
32 (139)
15
20
25
40
50
65
80
100
150
200
250
300
350
400
450
500
600
in.
1
/2
/4
1
1 1 /2
2
2 1 /2
3
4
6
8
10
12
14
16
18
20
24
Qm a x .
Qt
Qm i n .
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
3 (13)
5 (22)
7 (31)
20 (88)
30 (132)
50 (220)
80 (352)
120 (528)
300 (1320)
500 (2200)
800 (3520)
1200 (5280)
1600 (7040)
2000 (8810)
2600 (11450)
3000 (13210)
5000 (22010)
1.5 (7)
2.5 (11)
3.5 (15)
10 (44)
15 (66)
25 (110)
40 (176)
60 (264)
150 (660)
250 (1100)
400 (1760)
600 (2640)
800 (3520)
1000 (4400)
1300 (5720)
1500 (6600)
2500 (11010)
0.075 (0.33)
0.125 (0.55)
0.175 (0.77)
1.5 (6.6)
1.5 (6.6)
1.5 (6.6)
2 (8.8)
3 (13)
7.5 (33)
12.5 (55)
20 (88)
30 (132)
80 (352)
100 (440)
130 (572)
150 (660)
250 (1101)
0.010 (0.044)
0.016 (0.069)
0.025 (0.11)
0.063 (0.28)
0.1 (0.4)
0.16 (0.7)
0.3 (1.1)
0.4 (1.8)
1 (4)
1.6 (7)
2.5 (11)
4 (18)
8 (35)
13 (55)
18 (77)
20 (88)
32 (139)
0.004 (0.018)
0.006 (0.028)
0.01 (0.04)
0.025 (0.11)
0.04 (0.18)
0.063 (0.28)
0.1 (0.44)
0.16 (0.70)
0.4 (1.8)
0.63 (2.8)
1 (4)
1.6 (7)
3.2 (14)
5 (22)
7 (31)
8 (35)
13 (55)
(0 .2 5 % )
SS/AMAS/S_6
Battery-powered Meters Flow Requirements per CEN pr 14154 and latest ISO4064 (Standard Version)
Size
mm
in.
15
20
25
40
50
65
80
100
150
200
250
300
350
400
450
500
600
/2
/4
1
1 1 /2
2
2 1 /2
3
4
6
8
10
12
14
16
18
20
24
Q4
Q3
Q (0 .5 % )
Q2
Q1
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
5 (22)
8 (35)
12.5 (55)
31 (138)
50 (220)
79 (347)
125 (550)
200 (880)
500 (2200)
788 (3470)
1250 (5500)
2000 (8810)
2000 (8810)
3125 (13760)
4375 (19260)
5000 (22010)
7875 (34670)
4 (18)
6.3 (28)
10 (44)
25 (110)
40 (176)
63 (277)
100 (440)
160 (700)
400 (1760)
630 (2770)
1000 (4400)
1600 (7040)
1600 (7040)*
2500 (11010)*
3500 (15410)*
4000 (17610)*
6300 (27740)*
0.23 (1.0)
0.38 (1.7)
0.5 (2.3)
1.5 (6.6)
2.3 (9.9)
3.8 (16.5)
6 (26)
9 (40)
23 (100)
38 (170)
60 (260)
90 (400)
120 (530)
150 (660)
195 (860)
225 (990)
375 (1650)
0.025 (0.110)
0.039 (0.173)
0.063 (0.28)
0.156 (0.69)
0.3 (1.1)
0.39 (1.7)
0.6 (2.8)
1 (4.4)
3 (11)
3.9 (17)
6.3 (28)
10 (44)
25 (110)
31 (138)
44 (193)
63 (275)
79 (347)
0.010 (0.044)
0.016 (0.069)
0.025 (0.11)
0.063 (0.28)
0.1 (0.44)
0.16 (0.69)
0.25 (1.10)
0.4 (1.76)
1 (4.4)
1.6 (6.9)
2.5 (11)
4 (18)
10 (44)
13 (55)
18 (77)
25 (110)
32 (139)
R
400
400
400
400
400
400
400
400
400
400
400
400
160
200
200
160
200
AC-powered Meters Flow Requirements per CEN pr 14154 and latest ISO4064 (Standard Version)
Size
mm
15
20
25
40
50
65
80
100
150
200
250
300
350
400
450
500
600
10
in.
1
/2
/4
1
1 1 /2
2
2 1 /2
3
4
6
8
10
12
14
16
18
20
24
Q4
Q3
Q2
Q1
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
m3 /h (Ugal/min)
5 (22)
7.9 (35)
12.5 (55)
31 (138)
50 (220)
79 (247)
125 (550)
200 (880)
500 (2200)
788 (3470)
1250 (5500)
2000 (8810)
2000 (8810)
3125 (13760)
4375 (19260)
5000 (22010)
7875 (34760)
4 (18)
6.3 (28)
10 (44)
25 (110)
40 (176)
63 (277)
100 (440)
160 (700)
400 (1760)
630 (2770)
1000 (4400)
1600 (7040)
1600 (7040)*
2500 (11010)*
3500 (15410)*
4000 (17610)*
6300 (27740)*
0.075 (0.33)
0.13 (0.55)
0.18 (0.77)
1.5 (6.6)
1.5 (6.6)
1.5 (6.6)
2 (8.8)
3 (10)
8 (30)
13 (60)
20 (90)
30 (132)
80 (352)
100 (440)
130 (570)
150 (660)
250 (1100)
0.010 (0.044)
0.016 (0.069)
0.025 (0.11)
0.063 (0.28)
0.1 (0.4)
0.16 (0.7)
0.3 (1.1)
0.4 (1.8)
1 (4)
1.6 (7)
2.5 (11)
4 (18)
8 (35)
13 (55)
18 (77)
20 (88)
32 (139)
0.004 (0.018)
0.006 (0.028)
0.01 (0.04)
0.025 (0.11)
0.04 (0.18
0.063 (0.28)
0.1 (0.44)
0.16 (0.70)
0.4 (1.8)
0.63 (2.8)
1 (4)
1.6 (7)
3.21 (14)
5 (22)
7 (31)
8 (35)
13 (55)
(0 .2 5 % )
R
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
SS/AMAS/S_6
...Specification
Flow Requirements per CEN pr 14154 (Bulk Revenue Version)
Size
Q4
Q3
Q2
Q1
mm
in.
m /h (Ugal/min)
m /h (Ugal/min)
m /h (Ugal/min)
m /h (Ugal/min)
50
50 (220)
40 (176)
1 (4.4)
0.4 (1.8)
100
65
2 /2
79 (347)
63 (277)
1.6 (7)
0.63 (2.8)
100
80
125 (550)
100 (440)
2.5 (11)
1 (4.4)
100
100
200 (881)
160 (704)
4 (18)
1.6 (7.0)
100
150
500 (2200)
400 (1760)
10 (44)
4 (18)
100
200
788 (3470)
630 (2770)
16 (69)
6.3 (28)
100
250
10
1250 (5500)
1000 (4400)
25 (110)
10 (44)
100
300
12
2000 (8810)
1600 (7040)
40 (176)
16 (70)
100
Qmax.
Qt
Qmin.
mm
in.
m /h (Ugal/min)
m /h (Ugal/min)
m /h (Ugal/min)
m /h (Ugal/min)
50
30 (132)
15 (66)
3 (13.2)
0.45 (2.0)
65
2 /2
50 (220)
25 (110)
5 (22)
0.75 (3.3)
80
80 (358)
40 (176)
8 (35)
1.2 (5.3)
100
120 (528)
60 (264)
12 (53)
1.8 (7.9)
150
300 (1320)
150 (660)
30 (132)
4 .5(20)
200
500 (2200)
250 (1100)
50 (220)
7.5 (33)
250
10
800 (3520)
400 (1760)
80 (350)
12 (53)
300
12
1200 (5280)
600 (2640)
120 (530)
18 (79)
5%
Class B
2%
2%
5%
CEN pr 14154
Q1
ISO 4064
Q min.
Q2
Q3
Qt
QN
Q4
Qmax.
11
SS/AMAS/S_6
...Specification
Wetted Materials
Pressure Loss
Flowrate
Q 3 (CEN)
< 0.63
< 0.3
ISO 4064 Qn
< 0.075
< .019
Brass
Flanged meters
Electrodes stainless steel 316L
Lining
Suitable for potable water (UKWFBS listed)
Pressure limitations
Transmitter
As flange rating
Mounting
Conductivity
>50S/cm
or
Remote up to 200m (650 ft)
End Connections
Housing
/4 in. NPSM
1 in. NPSM
11/4 in. NPSM
Electrical connections
20/16mm plastic glands, 20mm armored or accepts 1/2 in. NPT
threaded or military style plug & socket
Sensor cable
ABB cable supplied as standard
SWA cable available on application
Power supply
Battery life @ 0 to 50C (32 to 122F)
Type
AC
Battery
Frequency (Hz)
VA
85 to 265
47 to 440
<10
3.6 (Lithium)
Temperature Ranges
Process
Ambient
70C (158F)
10C (14F)
10C (14F)
Storage
60C (140F)
70C (158F)
20C (4F)
30C (22F)
Note. Operation outside ambient temperature limits of 0 to 50C (32 to 122F) reduces battery capacity and shortens battery life.
12
SS/AMAS/S_6
Transmitter
Pulse and alarm outputs
Logger details
Output 2
Output 3
Logger
1
Logger Function
Flow &
Pressure
Flow &
Pressure
Forward,
Reverse,
Tariffs &
Net Flow
Totals
8831
11361
366
No. of Records
Logging Interval
24 hours
(fixed)
3 months
@15min.
~7 days
@ 1 min.
1 year
Cyclic
Cyclic
Cyclic
Use Primayer
Primeware
Typical Capacity
Telemetry applications using
remote serial data communications
15 to 65500s
(adjustable)
Mode
German
Spanish
Italian
Dutch
Other languages can be added via Windows download Program
(contact ABB)
GSM Antenna
Mounting
Integral with transmitter
or
Remote (1m cable)
Antenna environmental
IP66 (NEMA4) waterproof for accidental submersion
(Note. The GSM does not operate with integral antenna under
water)
General advice is to mount the antenna as high as possible,
always outside of any metal enclosure and not under the surface
of the ground
13
SS/AMAS/S_6
Specification
Mounting
Pipe Conditions
45
maximum
minimum
Flow Direction
Sensor Electrodes
Default European
Ugal
Totalizer Units
Ugal
ISO 4064 Qn
ISO 4064 Qn
Flow Units
m /h
MUGD
Velocity Units
m/s
ft/s
DDMMYY
MMDDYY
Gauge
Gauge
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Display Pressure
Display Date
No
No
Display Velocity
No
No
16
16
900
900
60
20
Pulses Forward
Pulses Forward
Pulses Reverse
Pulses Reverse
Profile Factor
14
SS/AMAS/S_6
Approx.
Weight
Connection
kg
15
/2
119 (4.7)
G 3 /4 in. B or 3 /4 in.NPSM
2.5
20
/4
127 (5)
2.5
127 (5)
2.5
25
Dimensions in mm (in.)
lb
61 (2.4)
128 (5)
89 (3.5)
Dimensions in mm (in.)
in.
Dimensions mm (in.)
A
Approx. Weight
kg
lb
40
1 /2
176 (7)
200 (7.9)
11
24
50
176 (7)
200 (7.9)
12
27
65
21/2
219 (8.6)
200 (7.9)
13
29
80
219 (8.6)
200 (7.9)
18
40
100
230.5 (9.8)
250 (9.8)
15
33
150
281 (11.8)
300 (11.8)
31
68
200
402 (15.8)
350 (13.8)
48
106
250
10
440 (17.3)
450 (17.7)
75
165
300
12
480 (18.9)
500 (19.7)
112
247
in.
350
14
Approx. Weight
C
kg
lb
100
220
400
16
115
253
450
18
160
352
500
20
217
455
600
24
315
693
mm
Dimensions mm (in.)
=50%A
Meter Size
15
SS/AMAS/S_6
Overall Dimensions
Terminal Box Sensor Mounted
Transmitter
Dimensions in mm (in.)
Dimensions in mm (in.)
95 (3.75)
105 (4.13)
80 (3.15)
M20 Cable
Antenna
(Option)
Installation and
wiring access
300 (12) minimum
460 (18) preferred
22 (0.8)
176 (7)
61 (2.4)
AquaMaster
30 (1.2)
140 (5.5)
170 (6.7)
Allowance for
cable bend:
Standard 130 (5)
Armored 230 (9)
Allowance for
cable bend:
Standard 130 (5)
Armored 230 (9)
Transmitter
Mounting Plate
(Remote Only)
16
SS/AMAS/S_6
Electrical Connections
Optional Power
Supply
Optional
GSM
Modem
Optional RS232
Communication
Port
Measurement
System
Pulse/Alarm
Circuits
Processor
Common
Display
Local Configuration
Adaptor
Optional
Pressure
Transducer
Part No. WEBC2000
17
SS/AMAS/S_6
Ordering Information
Main Code
Australia
Germany
Spain
France
UK
Holland
Italy
USA
MM/G A X
Default
Flange Type
40 to 300mm
Default
Flange Type
3 to 25mm
Default
Cable
Entry
AS4087 Class 16
ISO7005 PN16
ISO7005 PN16
ISO7005 PN16
ISO7005 PN16
ISO7005 PN16
ISO7005 PN16
ANSI B 16.5
Class 150
20/16mm
20/16mm
20/16mm
20/16mm
20/16mm
20/16mm
20/16mm
1
/2 in. NPT
Additional Code
XXXX X X X X
A
D
E
F
G
H
I
U
Calibrated Bore
mm
in.
15
20
25
40
50
65
80
100
150
200
250
300
350
400
450
500
600
/8
/4
1
1
1 /2
2
21/2
3
4
6
8
10
12
14
16
18
20
24
3
0015
0020
0025
0040
0050
0065
0080
0100
0150
0200
0250
0300
0350
0400
0450
0500
0600
1
2
3
A
B
D
Power Supply
AC
AC (with Battery Backup)
Battery
L
A
B
Options
With Earthing Rings (DN100)
With Earthing Rings (DN100) & Potting for Transmitter termination wiring
2
C
Cable Length
Not Required
10m
20m
30m
40m
50m
60m
70m
80m
100m
125m
150m
175m
200m
18
0
1
2
3
4
5
6
7
8
A
B
C
D
E
X X X 0 X 0 0 X 0 0 0
SS/AMAS/S_6
Main Code
MM/G A
XXXX
Additional Code
X
Labelling/Construction
ABB UK
ABB USA
Flange Style/End Connections
As defined by Country digit (see page 18)
AS4087 Class 14 Flanges (50 to 600mm [2 to 24 in.] only)
AS4087 Class 16 Flanges (50 to 600mm [2 to 24 in.] only)
AS2129 Table C Flanges (40 to 600mm [1.5 to 24 in.] only)
AS2129 Table D Flanges (40 to 600mm [1.5 to 24 in.] only)
AS2129 Table E Flanges (40 to 80mm [1.5 to 3 in.] only)
ISO7005 PN10 Flanged (40 to 600mm [1.5 to 24 in.] only)
ISO7005 PN16 Flanged (40 to 600mm [1.5 to 24 in.] only)
ANSI B16.5 Class 150 Flanged (1.5 to 12 in. only)
BS10 Table D Flanged (40 to 600mm [1.5 to 24 in.] only)
BS10 Table E Flanged (40 to 600mm [1.5 to 24 in.] only)
JIS B2210, 5k Flanged (40 to 600mm [1.5 to 24 in.] only)
JIS B2210, 10k Flanged (40 to 600mm [1.5 to 24 in.] only)
Parallel thread to ISO228-1 Class B (15 to 25mm [5 /8 to 1 in.] only)
Threaded to NPSM (5 /8 to 1 in. only)
Cable Entries
As defined by Country digit (see page 18). Cable not fitted/potted to sensor
20/16mm plastic glands. Cable not fitted/potted to sensor
20/16mm plastic glands. Cable fitted/potted to sensor
1
/2 in. NPT (USA only). Cable not fitted/potted to sensor
20mm armored. Cable not fitted/potted to sensor
20mm armored. Cable fitted/potted to sensor
MIL connector (sensor) + 16mm plastic glands. Cable fitted/potted to remote sensor
MIL connector (sensor) + 19 way MIL connector
+ 16mm plastic gland. Cable fitted/potted to remote sensor
20mm armored (sensor) + 16mm plastic glands. Cable not fitted to sensor
20mm armored (sensor) + 16mm plastic glands. Cable fitted/potted to sensor
Not Used
Calibration
1 Point (with Pressure Test)
3 Point (with Pressure Test)
NAMAS with Pressure Test (250mm [10 in.] only)
Bulk Revenue Version, 1 Point (with Pressure Test)
Bulk Revenue Version, 3 Point (with Pressure Test)
Not Used
Communications Option
Not Required
Remote Port RS232 C
ScanReader no cable fitted
ScanReader 5m cable fitted
GSM Modem, with internal antenna
GSM Modem, 1m remote antenna (not fitted)
Logger
Not required
ABB Logger enabled for ABB Software
ABB Logger enabled for CBV Software
ABB Logger enabled for Technolog Software
ABB Logger enabled for Primayer Software
ABB Logger enabled for Hydreka Software
SMS Logger enabled for ABB
SMS Logger enabled for Primayer
Pressure Transducer/Cable Length
Not required
Remote 1m cable
Remote 5m cable
Remote 10m cable
Remote 20m cable
Remote, no transducer
Pressure Transducer Span/Type
Not required
10bar Absolute Transducer
16bar Absolute Transducer
300 lb/in2 Absolute Transducer
0
1
0
A
Z
C
D
H
M
E
U
F
G
L
J
T
Y
0
1
B
3
2
C
5
6
7
D
0
1
3
4
7
8
0
1
2
3
6
7
0
1
2
3
4
5
7
8
0
1
2
3
4
Y
0
1
2
3
19
SS/AMAS/S_5
www.abb.com
SS/AMAS/S
Issue 6
ABB 2005
ABB Limited
Oldends Lane, Stonehouse
Gloucestershire
GL10 3TA
UK
Tel: +44 (0)1453 826661
Fax: +44 (0)1453 829671
ABB Inc.
125 E. County Line Road
Warminster
PA 18974
USA
Tel: +1 215 674 6000
Fax: +1 215 674 7183