Sie sind auf Seite 1von 8

CCTA

Air Handling Units

0.3 to 39.0 m3/s


1000 to 140 000 m3/h

The new CCTA Air Handling Unit


has been designed with accuracy,
indoor air quality and flexibility in
mind. This range meets most of the
demanding requirements in air
conditioning from comfort to
industrial applications:

Unequalled flexibility
Energy efficiency
High indoor air quality
CCTA-H Hygienic version
Eurovent certified
Easy Installation and
maintenance

Adaptable product

High built quality

The CCTA Air Handling Unit range


offers an extreme flexibility to meet
application constraints in terms of
thermal, acoustical, dimensional,
and functional aspects.
This range has been designed to
meet current customers needs for
new and existing buildings,
including offices, commercial
centers, retail stores, hotels, and
movie theatres. In addition many
options have been developed to
meet hospital and industrial
facilities requirements.

- The unit structure is based on a


newly designed framework made
of extruded anodized aluminum
and reinforced glass fiber or
aluminum corners to ensure
strong rigidity. The entire casing
construction is made with no
welding, providing a corrosion
resistant assembly and a long life
cycle.

Designed to meet every


project requirements

- The casing is made of 25, 40, 50,


60, 70 or 100 mm double wall
panels with various materials to
comply with thermal, acoustical
and hygienic requirements of all
projects.
- Panels are fitted to the framework
with a screwless locking system
including a specific rubber seal for
a nice finish, optimized air
tightness, and easy panel removal.

Quality and performance in


mind

2
American Standard Inc. 2005

Unequalled flexibility
The CCTA range covers air volumes
from 1000 to 140.000 m3/h with total
pressure up to 2000 Pa. The units
can be provided in an infinite
number of sizes variable with 50mm
increments.

Wide choice of components


All components are available with a
wide choice of options.

Fan-motor groups

Filtration

- Direct or belt driven plug fans

- EU3/G3 auto-roll filters

Wide choice of casing options


To comply with acoustical, thermal
and hygienic requirements, the unit
casing can be manufactured with
the following panel options:

- Pre filters EU1/G1 to EU4/G4

- Axial fans
All fans are fully insulated from the
casing with spring isolators and
flexible connections.

Wall materials
- Galvanized steel

- Soft and rigid bag filters EU6/F6 up


to EU9/F9.
- Absolute (HEPA) filters from
EU10/H10 up to EU14/H14

- Made of aero profiled aluminum


blades with frame and internal
nylon gears.

- Standard version: 25 or 50 mm

- Variable frequency drives


(VarioTrane)

- Steam humidifiers

- Peraluman

Panel thickness

- Motors class F, IP55.

Humidifying systems

- Inertial filters
Dampers

- Stainless steel 304 or 316

- Backward inclined or airfoil type

- Activated carbon filters

- Pre-painted steel
- Anodized aluminum

- Centrifugal forward curved

- Evaporative humidifiers

- Blades equipped with edge rubber


seals for an optimum air-tightness
as standard.

- Hygienic version: 65 mm

- Air washers
- Air/Water atomizing humidifiers
- Pressurized water atomizing
humidifiers
- Ultrasonic humidifiers
Silencers
For projects where low in duct
sound levels are required, CCTA
units can be equipped with
silencers available with various
executions and lengths for sound
attenuations from 24dB up to 45 dB
at 500 Hz.

- Super quiet version: 70 mm


Panel insulation
- Injected polyurethane foam with
40 kg/m3 density (0.6 mm thick
double skin)
- Mineral wool with 80 kg/m3
density (1.2 mm thick double skin)
Aluminum dampers
Heating and cooling coils
- Hot water and steam coils
- Electric heaters
- Chilled water and DX coils
All coils are available with various
materials and anti-corrosion
treatments.

Enhanced casing design

Modular unit construction

External units
CCTA Air Handling units are
available in outdoor version.
External units are equipped with a
proper roof protruding by 100 mm
all around the units.
Fresh air and exhaust air openings
are equipped with either weather
louvers or hoods.
Plug fan section

Hydraulic module

Wide choice of configurations


The CCTA modular unit construction
allows to accommodate site
constraints and can be built with the
following configurations:

Energy efficient
systems

- Horizontal in line
- Horizontal, L or U shaped
- Double stacked and side by side

External unit

- Vertical, up stream air flow.


Super quiet version
For projects where surrounding
sound levels are critical, CCTA units
can be manufactured with the
following options:
- Panel sheets from 0.6 to 2 mm
- Up to 100mm panel thickness
- High density mineral wool

Technical cabinets
To protect peripheral devices such
as humidifier generators, pumps,
valves, starters and other control
equipment, an additional cabinet
with the same casing construction
as the unit can be fitted to the side
of the unit.

For reduced operating costs, the


CCTA units can be equipped with
integrated heat recovery systems,
with efficiency from 40 to 80%:
Run around coils (coil loop)
With stacked or side by side
exhaust/supply units, the heat
recovery system can be fully
equipped with the hydraulic
module, including expansion tank,
circulating pump, piping, and all
necessary parts needed for proper
operation.

- Perforated internal metal sheet.


Enhanced thermal performances.
When Air Handling Units have to be
installed in severe humidity and
temperature conditions, CCTA units
can be built with 70 mm triple skin
panels. In this case, panels and
framework include a thermal break
profile to minimize thermal bridges.
For non common applications with
low supply air temperature or
severe climate conditions, please
contact your local Trane sales office.

A solution for each project


need

Plate heat exchangers


Made of aluminum and optionally
protected against corrosion with an
acrylic treatment, the plate heat
exchangers can be provided with
bypass damper to control
temperature and prevent freezing.
Thermal rotary wheels
Of sensible or hygroscopic type
with high efficiency, the thermal
wheels are equipped with individual
motor, drive and speed controller.

Reduction of operating costs

Thermal break profile

Indoor air quality

Hygiene Options

CCTA Air Handling Units have been


designed with Indoor Air Quality in
mind to provide occupants with a
safe, enjoyable and productive
environment.

Cleanable version
When integral cleaning inside the
units is required, all components
such as fan motor groups, silencers,
and droplet eliminator can be fitted
on rails or rollers for an easy
removal.

Casing air tightness


Air tightness certified Class B as per
EN 1886, ensures minimized
untreated air bypass.

Cold room type door handle

Inclined drain pans


On all units, cooling coil, humidifier
and heat recovery sections are
equipped with inclined drain pans
made of stainless steel 430 quality.

CCTA-H
Hygienic version

Stainless steel
Frames of cooling coil and droplet
eliminator are made of stainless
steel as standard.
High efficiency filters
Fitted on universal frames, the
filters used on all units minimize
filter bypass leakage: 0.21% bypass
leakage over 400 Pa differential
pressure. Corresponds to Class F9
as per EN1886.
Optional features
For applications with aggressive air
or for cleaning purposes, the
panels, framework and other
internal metallic parts such as filter
frames and supports can be
optionally treated against corrosion
or manufactured with specific
materials such as aluminum or
stainless steel.

Easy fan removal

For applications where hygiene


requirements are critical such as
hospitals, laboratories, clean rooms,
the CCTAH (Hygienic execution) is
available with the following
additional features:
- Special hygienic framework with
round corners
- 65 mm triple skin panel

Automatic cleaning system


Sections needing to be regularly
cleaned or disinfected can be
provided with the following options:
- Welded inner skin made of
stainless steel providing a fully
water-tight section.

- Minimized dust traps due to


smooth internal walls

60

- Fully air tight Cold room type


door handles.
- Automatic factory mounted
cleaning system which can be
programmable.

15

The IAQ solution for the


specific needs of your
application

Cleaning nozzle

Hygienic construction

- All units are delivered with a


150 mm high base frame or feet
for easy on site lifting and
positioning.
- All sections requiring regular
access for maintenance are
equipped with properly sized and
air tight hinged doors.

Eurovent certified
Trane is participating in the
Eurovent participation program for
Air Handling Units. The CCTA range
is certified under the number
03.12.047 and presented in the
directory of certified AHU.

- Units provided in several sections


are delivered with a quick locking
system to allow easy section
connection with no special tool.

Successful installation
guaranteed

Integrated comfort
systems

The unit performances and the


mechanical casing characteristics
have been tested and certified
respectively according to EN13053
and EN 1886:

The factory mounted controls


package can be tied to other Trane
products through Trane Integrated
Comfort System (ICS), a powerful
system architecture that unifies
Trane control and building
management into a coherent whole
with an assured source of comfort:

Certified performances

- Single source of responsibility


- Monitoring and diagnostics
- System optimization
- Open protocol communication.

Contact your local sales


office for more information

Easy installation and


maintenance

Factory mounted
controls

- Units can be delivered in one


piece, in sections, or flat packed
for easier on site assembly.

Upon request, CCTA units can be


provided with factory mounted
controls as a plug and play product.
The control system including
control panel, sensors, actuators,
and motor starters is engineered,
mounted, wired and tested before
shipment, resulting in:

Service in mind

- Minimized job coordination

- Supply of spare parts

- Faster commissioning by Trane


experts.

- Warranty and maintenance


contracts.

- All panels can be easily removed


to maintain, repair or change
components inside the unit.
- Motors up to 2.2 KW are equipped
as standard with variable pitch
pulleys to adjust the air volume on
site.

Trane offers a wide range of


services to support its products in
the field:
- On site unit assembly supervising
- Commissioning by qualified
engineers

Extended service for a


constant optimization of
your equipment performance

Quick selection chart - CCTA standard sizes

590
640
690
790
890
990
990
1040
1140
1140
1340
1340
1340
1440
1440
1590
1630
1630
1630
1780
1780
1780
1780
1940
2130
2130
2280
2280
2300
2360

004
005
007
009
012
015
018
023
025
030
035
040
044
050
055
062
074
083
090
105
115
121
135
146
173
187
211
243
280
333

1080
1620
2160
2754
3726
4536
5400
6804
7776
9180
10692
12312
13284
15444
16632
18630
22464
25056
27081
31671
34560
36720
40500
44226
52164
56511
63450
73008
84672
100683

0.300
0.450
0.600
0.765
1.035
1.260
1.500
1.890
2.160
2.550
2.970
3.420
3.690
4.290
4.620
5.175
6.240
6.960
7.523
8.798
9.600
10.200
11.250
12.285
14.490
15.698
17.625
20.280
23.520
27.968

1296
1944
2592
3305
4471
5443
6480
8165
9331
11016
12830
14774
15941
18533
19958
22356
26957
30067
32497
38005
41472
44064
48600
53071
62597
67813
76140
87610
101606
120820

0.360
0.540
0.720
0.918
1.242
1.512
1.800
2.268
2.592
3.060
3.564
4.104
4.428
5.148
5.544
6.210
7.488
8.352
9.027
10.557
11.520
12.240
13.500
14.742
17.388
18.837
21.150
24.336
28.224
33.561

1512
2268
3024
3856
5216
6350
7560
9526
10886
12852
14969
17237
18598
21622
23285
26082
31450
35078
37913
44339
48384
51408
56700
61916
73030
79115
88830
102211
118541
140956

0.420
0.630
0.840
1.071
1.449
1.764
2.100
2.646
3.024
3.570
4.158
4.788
5.166
6.006
6.468
7.245
8.736
9.744
10.532
12.317
13.440
14.280
15.750
17.199
20.286
21.977
24.675
28.392
32.928
39.155

540
540
590
640
640
690
790
840
840
890
940
990
990
1040
1140
1190
1280
1280
1380
1380
1530
1530
1530
1580
1730
1730
1830
1880
2030
2330

690
590
690
690
690
840
840
840
840
840
840
940
940
940
940
1180
1180
1180
1280
1280
1480
1580
1580
1580
1580
1580
1580
1580
1580
1580

840
840
840
1040
1040
1040
1440
1440
1440
1440
1440
1640
1640
1640
1640
1690
2080
2080
2280
2280
2680
2880
2880
2880
2880
2880
3130
3130
3280
3280

790
790
790
790
790
790
790
790
790
790
790
790
790
790
790
830
830
830
830
830
830
830
830
830
830
830
830
830
830
830

440
440
440
440
440
440
440
440
440
440
440
440
440
440
440
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480

1140
1140
1140
1140
1290
1290
1290
1440
1540
1540
1540
1840
1840
1840
1840
1890
1880
1880
1880
2430
2430
2430
2430
2430
3030
3580
3580
3730
3730
3880

790
790
790
790
790
790
790
790
790
790
790
790
790
790
790
830
830
830
830
830
830
830
830
830
830
830
830
830
830
830

440
440
440
440
440
440
440
440
440
440
440
440
440
440
440
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480

690
590
690
690
690
840
840
840
840
840
840
940
940
940
940
1180
1180
1180
1280
1280
1480
1580
1580
1580
1580
1580
1580
1580
1580
1580

sound
attenuator

mm

mm

from 1390 to 2190

0.420
0.630
0.882
1.103
1.512
1.796
2.174
2.657
3.003
3.549
4.253
4.725
5.198
5.891
6.426
7.182
8.778
9.702
10.584
12.317
13.608
14.700
15.876
17.294
20.160
22.050
24.864
28.560
32.918
38.913

mm

from 1430 to 2230

1512
2268
3175
3969
5443
6464
7825
9563
10811
12776
15309
17010
18711
21206
23134
25855
31601
34927
38102
44339
48989
52920
57154
62257
72576
79380
89510
102816
118503
140087

mm

from 1390 to 2190

0.360
0.540
0.756
0.945
1.296
1.539
1.863
2.277
2.574
3.042
3.645
4.050
4.455
5.049
5.508
6.156
7.524
8.316
9.072
10.557
11.664
12.600
13.608
14.823
17.280
18.900
21.312
24.480
28.215
33.354

mm

from 1430 to 2230

1296
1944
2722
3402
4666
5540
6707
8197
9266
10951
13122
14580
16038
18176
19829
22162
27086
29938
32659
38005
41990
45360
48989
53363
62208
68040
76723
88128
101574
120074

humidifcation
section

0.300
0.450
0.630
0.788
1.080
1.283
1.553
1.898
2.145
2.535
3.038
3.375
3.713
4.208
4.590
5.130
6.270
6.930
7.560
8.798
9.720
10.500
11.340
12.353
14.400
15.750
17.760
20.400
23.513
27.795

mm

from 490 to 1590

1080
1620
2268
2835
3888
4617
5589
6831
7722
9126
10935
12150
13365
15147
16524
18468
22572
24948
27216
31671
34992
37800
40824
44469
51840
56700
63936
73440
84645
100062

mm

from 530 to 1730

004
005
007
009
012
015
018
023
025
030
035
040
044
050
055
062
074
083
090
105
115
121
135
146
173
187
211
243
280
333

mm
mm
kW*
Single fan air handling units
690
890
1.1
790
890
1.5
890
940
2.2
1040
940
2.2
1090
1040
4.0
1240
1140
5.5
1440
1290
5.5
1440
1290
5.5
1590
1290
5.5
1590
1290
7.5
1640
1390
9.2
1790
1390
11.0
1990
1490
11.0
1990
1590
15.0
2140
1690
15.0
2140
1740
15.0
2580
1730
18.5
2580
1830
18.5
2780
1830
22.0
2930
1830
30.0
3080
2030
30.0
3080
2130
30.0
3530
2130
37.0
3430
2130
37.0
3580
2230
45.0
3880
2330
45.0
4080
2430
55.0
4630
2530
55.0
5130
2530
75.0
5830
2630
90.0
double fan air handling units
790
840
1.1
890
840
1.5
1090
890
2.2
1140
890
2.2
1440
940
4.0
1490
1040
5.5
1540
1190
5.5
1690
1140
5.5
1890
1140
5.5
1990
1140
7.5
2090
1240
9.2
2190
1240
11.0
2390
1290
11.0
2540
1390
15.0
2540
1440
15.0
2640
1490
15.0
2980
1480
18.5
3280
1530
18.5
3330
1580
22.0
3830
1630
30.0
3580
1730
30.0
3680
1830
30.0
4130
1830
37.0
4280
1830
37.0
4580
2030
45.0
4930
2030
45.0
5080
2130
55.0
5580
2230
55.0
5980
2230
75.0
6030
2330
90.0

from 490 to 1590

mm

from 530 to 1730

m3/s

plate heat
exch

m3/h

coils section

m3/s

bag filters

m3/h

double
mixing box

3.5

m3/s

single mixing
box

3.0

m3/h

Section length

fan section

2.5

height

Size

width

Unit cross
dimensions

Airflow rate at different coil face velocity (m/s)

Above section length are for indication only and for use for at the early stage of the project.
Unit cross dimensions refer to 25 mm panel for unit up to size 062 and 50 mm panel for larger units.
Unit height does not include feet or continuous base which are both 150 mm.
The unit width can be adjusted by 50 mm increments to comply with project specifications.
Dimensions can be changed depending on casing construction and selected components.
* Nominal motor size: motor size has been calculated considering 1000 Pa total static pressure and airflow at 2,5 m/s.

Optimized operation
The CCTA Air Handling Unit is an
environmentally friendly product:
- Recyclable components and casing
- Low energy consumption through
optimized component selection
- Optimized operation costs due to
efficient controls systems

Health and safety


- High efficiency heat recovery
systems
- Direct expansion system using
chlorine-free and ozone layer
friendly refrigerants.

Guaranteed long future for


your installation

The CCTA Air Handling unit, like all


Trane products, are designed and
manufactured with enhanced
features to ensure easier and safer
operation and maintenance.

Safe working environment

TRANE comfort systems


Tracer
Summit
VAV Box

Chiller CGAN

The Air Handling Solution Provider

Variable
Frequency Drive

Factory Engineered
Controls

CCTA

Literature Order Number

CCTA-SLB001

Date

1005

New
Literature Stocking Location
Europe
Trane has a policy of continuous product and product data improvement and reserves the right to change
design and specifications without notice.

www.trane.com
For more information, contact your local
sales office or e-mail us at comfort@trane.com

American Standard Europe BVBA


Registered Office: 1789 Chausse de Wavre, 1160 Brussels - Belgium

Das könnte Ihnen auch gefallen