Accuracy, repeatability, rangeability and flow range


make gas turbine meters the preferred choice in an
increasing number of gas measurement applications.
American Meters gas turbine meters, first introduced
in 1968, now serve the gas industry in installations
throughout the world.
American Meters gas turbines incorporate refinements
in design learned from years of application experience.
Refinements that improve performance and reduce the
cost of maintenance and ownership. Our gas turbines
offer a mechanical output to drive a wide variety of
auxiliary devices such as base volume correctors,
plus electronic pulse outputs to interface with flow
computers. Low-, medium- and high-pressure models
are available in 3-inch through 12-inch sizes. Direct
replacement for specified 4", 6" and 8" Equimeter
models are also available.

Options
Mechanical Drive Output
Mechanical and Electronic Pulse Outputs
Temperature Compensation
Standard and Extended Capacity Ranges with 45
or 30 Rotors

Calibration Facilities
The American Meter gas turbine meter line is
supported by three calibration facilities available
for low-, medium- and high-pressure testing and
re-certifications.
Low Pressure
Atmospheric-pressure air testing is done on a high
capacity sonic nozzle prover and on a 350-cubic foot
(10-cubic meter) bell prover. Accuracy of the provers
is traceable to the U.S. National Institute of Standards
and Technology (formerly the National Bureau of
Standards). Flow rates to 130,000 cubic feet per hour
(370 cubic meters per hour).
Medium Pressure
Medium-pressure testing is conducted on a
recirculating air loop at pressures to 150 psi (10 bar).
The loop is available for certification or re-certification
of meter performance under actual operating pressures. Certified master turbine meters are the
reference standards.
High Pressure
American Meters high-pressure test station, located
at a gas storage field in northwestern Pennsylvania,
is 30 minutes from the manufacturing plant. Test
pressures to 750 psi (50 bar) and higher are available.
Master turbine meters tested in Europe and at Southwest Research Institute are used as reference meters.

Top and Middle Photos: High-pressure test facility.


Bottom Photo: Low-pressure 350 ft.3 (10M 3) Bell Prover.

9
2

4
10
2/8
1/11

Features And Benefits (GTS and E-Class Meters)


1 Models with Extended Capacity Ratings can
reduce the diameter of an entire meter run, resulting
in substantial savings in piping, flanges, block
valves, etc. See Capacity Tables.
2 Mechanical Drive Models for use with P&T Correctors
or Electronic Pulse Output Models to interface
directly with popular flow computers.
3 Electronic Temperature Compensation with Fixed
Factor Pressure.
4 Flush-Type Lubrication System flushes main
bearings while meter is in operation.
5 Aluminum Rotors for high pressure models and
for meters with high-frequency pulse outputs.
3

6 One Output Gear Train for all meter sizes; reduces


spare parts inventory.
7 High-Efficiency Inlet Flo-Guide flow conditioners
to minimize the effects of flow disturbances in
short coupled installations.
8 High-Frequency RF-Type Pulser that monitors rotor
condition.
9 Interchangeable Pre-Calibrated Measurement
Cartridges for easy maintenance.
10 Pre-Machined Meter Housings to allow upgrade
to AccuTest self-test model.
11 Direct Equimeter Turbine Meter Replacement with
new E-Class models.

3" GTS Capacities


Output Drive 100 Ft.3 / 45 Rotor Angle

3" GTS Capacities


Output Drive 1.0m3 / 45 Rotor Angle

Line
Min. Actual Press.
1000 SCFH
Pressure
Range
Flow Rate Drop In.
(psig)
Q max Q min Q max/Qmin
MACFH
W.C.

Line Pressure

0.25
5
10
15
20
25
50
75
100
125
150
175
200
275
300
400
500
600
700
800
900
1,000
1,100
1,200
1,300
1,400

0.02
2
0.30
30
0.70
70
1.00
100
2.00
200
3.00
300
5.00
500
7.00
700
8.00
800
9.00
900
10.00 1,000
12.00 1,200
15.00 1,500
20.00 2,000
30.00 3,000
35.00 3,500
40.00 4,000
50.00 5,000
60.00 6,000
70.00 7,000
80.00 8,000
90.00 9,000
100.00 10,000

10 0.83
13 0.96
17 1.08
20 1.18
23 1.28
27 1.37
44 1.76
61 2.08
79 2.36
97 2.62
114 3.35
132 3.07
150 3.28
205 3.86
224 4.04
301 4.72
379 5.35
461 5.95
545 6.52
632 7.09
722 7.64
814 8.18
910 8.71
1,007 9.24
1,106 9.76
1,197 10.18

12
14
15
17
18
20
25
30
33
37
40
43
46
53
55
64
71
78
84
89
95
100
104
109
113
118

0.83
0.73
0.65
0.59
0.55
0.51
0.40
0.34
0.30
0.28
0.30
0.24
0.23
0.20
0.19
0.17
0.15
0.14
0.13
0.13
0.12
0.12
0.12
0.11
0.11
0.11

Bar

4.5
6.0
7.5
9.0
10.5
12.1
19.7
27.3
35.0
42.6
50.2
57.9
65.5
88.4
96.1
127
157
188
218
249
279
310
340
371
402
432

kPa

SCMH
Q max Q min
284
365
482
559
841
1,124
1,694
2,270
2,559
2,851
3,143
3,733
4,626
6,143
9,289
10,912
12,581
16,031
19,630
23,387
27,274
31,287
35,478

24
27
31
33
41
47
58
67
72
76
80
87
97
112
140
153
165
188
211
233
254
275
296

Range Min. Actual Press.


Q max/
Q min

Flow Rate
Am3/h

Drop
mbar

12
14
16
17
21
24
29
34
36
38
40
43
48
55
66
72
76
85
93
100
107
114
120

23.5
21.0
18.5
16.8
13.8
12.0
9.8
8.5
8.1
7.7
7.3
6.8
6.1
5.4
4.6
4.3
4.1
3.7
3.5
3.3
3.2
3.1
3.0

11.3
14.3
18.8
22.1
33.1
44.2
66.3
88.4
99.5
111
122
144
177
232
343
398
453
564
674
785
895
1,006
1,116

Note: Capacity Table values established @ base pressure of 101.325 kPa and
base temperature of 15 C. Supercompressibility included.

Note: Capacity Table values established @ base pressure of 14.73 PSIA and
base temperature of 60F. Supercompressibility included.

3" GTS Turbine Meter

4" GTS, GTX and E-Class Capacities Output Drive 100 ft.3
45 Rotor Angle

30 Rotor Angle

Line
Pressure
PSIG

Qmax
MSCFH

0.25
5
10
15
20
25

18
24
30
36
42
48

1.2
1.4
1.5
1.7
1.8
2.0

15
17
19
21
23
25

1.20
1.06
0.90
0.85
0.77
0.75

2.4
3.2
4.0
4.8
5.6
6.4

23
30
38
46
54
62

1.9
2.2
2.5
2.7
3.0
3.2

12
14
15
17
18
20

1.92
1.65
1.48
1.36
1.26
1.18

3.9
5.2
6.5
7.8
9.1
10.5

50
75
100
125
150

80
110
142
173
206

2.5
3.0
3.4
3.8
4.8

31
37
42
46
50

0.58
0.50
0.43
0.40
0.43

10.5
14.6
18.7
22.7
26.8

102
142
182
222
263

4.1
4.8
5.4
6.0
7.7

25
30
33
37
40

0.93
0.79
0.70
0.64
0.69

17.1
23.7
30.3
36.9
43.5

175
200
275
300
400

239
271
370
403
540

4.4
6.0
5.5
5.8
6.8

54
57
66
69
80

0.34
0.41
0.28
0.27
0.24

30.9
34.9
47.2
51.2
67.5

304
346
472
516
691

7.1
7.6
8.9
9.3
10.9

43
46
53
55
64

0.55
0.52
0.45
0.44
0.39

50.2
56.8
76.6
83.3
110

500
600
700
800
900

695
830
981
1,138
1,299

7.7
8.6
9.4
10.2
11.0

89
97
104
112
118

0.22
0.21
0.19
0.18
0.18

83.8
100
116
133
149

872
1,060
1,254
1,455
1,661

12.3
13.7
15.0
16.3
17.6

71
78
84
89
95

0.35
0.33
0.31
0.29
0.28

136
163
189
216
242

1,000
1,100
1,200
1,300
1,400

1,466
1,637
1,812
1,991
2,154

11.8
12.5
13.3
14.0
14.7

124
130
136
142
147

0.17
0.17
0.16
0.16
0.15

165
182
198
214
230

1,873
2,092
2,315
2,544
2,754

18.8
20.0
21.2
22.4
23.4

100
104
109
113
118

0.27
0.26
0.26
0.25
0.24

269
295
322
348
375

Qmin
MSCFH

Range
Qmax/Qmin

Min. Actual
Flow Rate
MACFH

Press. Drop
Inches
W.C.

Qmax
MSCFH

Qmin
MSCFH

Min. Actual Press. Drop


Range
Flow Rate
Inches
Qmax/Qmin MACFH
W.C.

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60F. Supercompressibility included.
Meters with 30 rotors have higher Qmax and Qmin values.

4" GTS, GTX and E-Class Capacities Output Drive 1.0m3


45 Rotor Angle
Line Pressure
Bar

kPa

Qmax
Sm3/h

Qmin
Sm3/h

30 Rotor Angle

Min. Actual
Range
Flow Rate
Qmax/Qmin
Am3/h

Pressure
Drop
mbar

Qmax
Sm3/h

Qmin
Sm3/h

Min. Actual
Range
Flow Rate
Qmax/Qmin
Am3/h

Pressure
Drop
mbar

0.02
0.30
0.70
1.00
2.00
3.00

2
30
70
100
200
300

509
657
867
1,006
1,513
2,022

34
39
45
48
59
68

15
17
19
21
26
30

34
30
27
24
20
17

6.0
7.7
10.1
11.8
17.8
23.7

651
841
1,109
1,287
1,935
2,587

54.1
61.9
71.4
76.4
93.7
108.5

12
14
16
17
21
24

53.9
48.3
42.6
38.7
31.7
27.5

9.8
12.6
16.4
19.3
29.0
38.7

5.00
7.00
8.00
9.00
10.00

500
700
800
900
1,000

3,047
4,082
4,603
5,127
5,654

83
97
103
109
114

36
42
45
47
49

14
12
12
11
11

35.5
47.4
53.3
59.2
65.1

3,897
5,221
5,887
6,558
7,231

133.5
154.9
164.6
174.0
182.9

29
34
36
38
40

22.5
19.6
18.5
17.6
16.9

58.0
77.4
87.0
96.7
106

12.00
15.00
20.00
30.00
35.00

1,200
1,500
2,000
3,000
3,500

6,714
8,320
11,049
16,707
19,626

125
140
162
201
220

54
60
68
83
89

10
9
8
7
6

77.0
94.7
124
184
213

8,587
10,641
14,132
21,368
25,101

199.8
223.2
258.7
321.9
350.9

43
48
55
66
72

15.6
14.1
12.5
10.5
9.9

126
155
203
300
348

40.00
50.00
60.00
70.00
80.00

4,000
5,000
6,000
7,000
8,000

22,628
28,834
35,306
42,064
49,054

237
271
303
335
366

95
106
116
126
134

6
5
5
5
5

243
302
361
420
480

28,941
36,878
45,155
53,799
62,740

379.1
433.2
485.0
535.6
584.8

76
85
93
100
107

9.4
8.6
8.1
7.6
7.3

397
493
590
687
783

90.00
9,000
100.00 10,000

56,272
63,810

396
426

142
150

4
4

539
598

71,970
81,612

632.9
681.2

114
120

7.0
6.8

880
977

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15 C. Supercompressibility included.
Meters with 30 rotors have higher Qmax and Qmin values.

6" GTS, GTX and *E-Class Capacities Output Drive 100 ft.3
45 Rotor Angle
Line
Pressure
PSIG

Qmax
MSCFH

0.25
5
10
15
20
25

30 Rotor Angle

Qmin
MSCFH

Range
Qmax/Qmin

Min. Actual
Flow Rate
MACFH

Press. Drop
Inches
W.C.

35
46
58
70
82
94

1.9
2.2
2.5
2.8
3.0
3.2

18
21
23
25
28
29

1.94
1.69
1.51
1.38
1.27
1.19

3.3
4.4
5.5
6.6
7.7
8.8

50
66
83
100
117
134

3.3
3.8
4.3
4.7
5.1
5.5

15
17
19
21
23
25

3.34
2.90
2.59
2.36
2.18
2.03

6.7
8.9
11.2
13.5
15.8
18.1

50
75
100
125
150

154
215
276
338
401

4.1
4.9
5.5
6.1
7.8

38
44
50
55
60

0.94
0.80
0.71
0.64
0.70

14.4
20.0
25.6
31.2
36.8

220
307
395
483
572

7.0
8.3
9.4
10.4
11.3

31
37
42
47
51

1.59
1.34
1.19
1.07
0.99

29.7
41.4
53.2
65.0
77.0

175
200
275
300
400

463
526
719
785
1,052

7.2
7.7
9.0
9.4
11.0

65
69
80
83
95

0.56
0.53
0.46
0.44
0.39

42.4
48.1
64.9
70.5
92.9

661
752
1,027
1,121
1,502

12.1
12.9
15.1
15.8
18.3

55
58
68
71
82

0.92
0.86
0.74
0.70
0.61

89
101
138
151
202

500
600
700
800
900

1,328
1,613
1,908
2,213
2,527

12.5
13.9
15.2
16.5
17.8

106
116
125
134
142

0.36
0.33
0.31
0.30
0.29

115
138
160
182
205

1,897
2,305
2,726
3,161
3,610

20.5
22.6
24.6
26.5
28.3

92
102
111
119
127

0.54
0.49
0.45
0.42
0.39

256
310
367
426
486

1,000
1,100
1,200
1,300
1,400

2,851
3,183
3,524
3,872
4,190

19.1
20.3
21.6
22.8
23.8

149
157
163
170
176

0.28
0.27
0.26
0.26
0.25

227
250
272
294
317

4,072
4,547
5,034
5,531
6,041

30.1
31.8
33.4
35.1
36.6

135
143
151
158
165

0.37
0.35
0.33
0.32
0.30

549
613
678
745
814

Qmax
MSCFH

Qmin
MSCFH

Min. Actual Press. Drop


Range
Flow Rate
Inches
Qmax/Qmin MACFH
W.C.

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60F. Supercompressibility included.
Meters with 30 rotors have higher Qmax and Qmin values.
* E-Class not available in 1440 psig MAOP.

6" GTS, GTX and *E-Class Capacities Output Drive 1.0m3


45 Rotor Angle
Line Pressure
Bar

kPa

Qmax
Sm3/h

Qmin
Sm3/h

30 Rotor Angle

Min. Actual
Range
Flow Rate
Qmax/Qmin
Am3/h

Pressure
Drop
mbar

Qmax
Sm3/h

Qmin
Sm3/h

Min. Actual
Range
Flow Rate
Qmax/Qmin
Am3/h

Pressure
Drop
mbar

0.02
0.30
0.70
1.00
2.00
3.00

2
30
70
100
200
300

1,000
1,291
1,703
1,977
2,972
3,973

55
63
73
78
96
111

18
20
23
25
31
36

55
49
44
40
32
28

8.2
10.5
13.7
16.2
24.3
32.4

1,440
1,836
2,403
2,829
4,253
5,679

95.7
108.0
123.6
134.1
164.4
190.0

15
17
19
21
26
30

95.0
84.1
73.5
67.8
55.3
47.8

5.00
7.00
8.00
9.00
10.00

500
700
800
900
1,000

5,986
8,020
9,043
10,073
11,107

137
159
169
178
187

44
51
54
57
59

23
20
19
18
17

48.5
64.7
72.8
80.9
89.0

8,570
11,473
12,956
14,409
15,902

233.4
270.0
287.0
302.6
317.9

37
42
45
48
50

38.9
33.7
31.7
30.0
28.6

101
135
152
169
187

12.00
15.00
20.00
30.00
35.00

1,200
1,500
2,000
3,000
3,500

13,190
16,346
21,708
32,823
38,558

205
229
265
330
359

64
72
82
100
107

16
14
13
11
10

105
129
170
251
291

18,875
23,258
31,119
46,813
55,176

346.4
384.5
444.7
545.5
592.2

54
60
70
86
93

26.2
23.6
20.4
16.7
15.4

221
273
365
549
647

40.00
50.00
60.00
70.00
80.00

4,000
5,000
6,000
7,000
8,000

44,455
56,648
69,363
82,640
96,374

388
444
497
548
599

114
128
140
151
161

10
9
8
8
7

332
413
494
575
655

63,881
81,261
99,691
118,499
138,322

637.2
718.7
796.0
867.8
937.6

100
113
125
137
148

14.3
12.7
11.4
10.5
9.7

749
953
1,169
1,390
1,622

90.00
9,000
100.00 10,000

110,554
125,364

648
698

171
180

7
7

736
817

159,214
180,742

1,005.9
1,071.8

158
169

9.0
8.5

1,867
2,119

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15 C. Supercompressibility included.
Meters with 30 rotors have higher Qmax and Qmin values.
* E-Class not available in 100 Bar MAOP.

16.9
21.5
28.2
33.2
49.9
66.6

8" GTS, GTX and *E-Class Capacities Output Drive 1,000 ft.3
45 Rotor Angle
Line
Pressure
PSIG

Qmax
MSCFH

0.25
5
10
15
20
25

60
79
100
120
141
161

50
75
100
125
150

30 Rotor Angle

Range
Qmax/Qmin

Min. Actual
Flow Rate
MACFH

3
3.5
3.9
4.3
4.6
4.9

20
23
26
28
31
33

3.00
2.61
2.33
2.13
1.97
1.84

1.6
2.1
2.7
3.2
3.7
4.3

88
116
146
177
207
237

5.9
6.8
7.6
8.3
9.0
9.6

15
17
19
21
23
25

5.87
5.11
4.56
4.16
3.85
3.60

3.4
4.5
5.7
6.8
8.0
9.1

265
369
474
580
686

6.3
7.5
8.5
9.4
12.1

42
49
56
62
67

1.45
1.23
1.09
0.99
1.08

7.0
9.7
12.4
15.2
17.9

388
541
695
850
1,006

12.4
14.6
16.6
18.4
23.6

31
37
42
46
50

2.83
2.41
2.14
1.95
2.11

14.9
20.7
26.4
32.2
38.0

175
200
275
300
400

794
902
1,232
1,345
1,803

11.1
11.8
13.9
14.6
17.0

72
76
89
92
106

0.86
0.81
0.71
0.68
0.60

20.6
23.3
31.4
34.2
45.0

1,164
1,324
1,807
1,973
2,645

21.6
23.1
27.2
28.5
33.2

54
57
66
69
80

1.68
1.59
1.38
1.33
1.18

43.7
49.5
66.8
72.6
95.7

500
600
700
800
900

2,276
2,766
3,271
3,794
4,332

19.3
21.4
23.5
25.5
27.5

118
129
139
149
158

0.55
0.51
0.48
0.46
0.44

55.9
66.7
77.6
88.5
99.3

3,339
4,056
4,798
5,564
6,354

37.7
41.9
45.9
49.9
53.8

89
97
104
112
118

1.08
1.00
0.95
0.90
0.87

119
142
165
188
211

1,000
1,100
1,200
1,300
1,400

4,887
5,457
6,041
6,638
7,184

29.4
31.4
33.3
35.1
36.7

166
174
182
189
196

0.43
0.41
0.40
0.39
0.38

7,167
8,004
8,860
9,735
10,536

57.6
61.3
65.1
68.7
71.7

124
130
136
142
147

0.84
0.81
0.79
0.77
0.75

234
257
280
303
326

Qmin
MSCFH

Press. Drop
Inches
W.C.

110
121
132
143
154

Qmax
MSCFH

Qmin
MSCFH

Min. Actual Press. Drop


Range
Flow Rate
Inches
Qmax/Qmin MACFH
W.C.

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60F. Supercompressibility included.
Meters with 30 rotors have higher Qmax and Qmin values.
* E-Class not available in 1440 psig MAOP.

8" GTS, GTX and *E-Class Capacities Output Drive 10m3


45 Rotor Angle
Line Pressure
Bar

kPa

Qmax
Sm3/h

Qmin
Sm3/h

30 Rotor Angle

Min. Actual
Range
Flow Rate
Qmax/Qmin
Am3/h

Pressure
Drop
mbar

Qmax
Sm3/h

Qmin
Sm3/h

Min. Actual
Range
Flow Rate
Qmax/Qmin
Am3/h

Pressure
Drop
mbar

0.02
0.30
0.70
1.00
2.00
3.00

2
30
70
100
200
300

1,700
2,195
2,895
3,360
5,053
6,755

85
97
112
120
147
170

20
23
26
28
34
40

84
76
67
61
50
43

4.0
5.1
6.7
7.9
11.8
15.8

2,500
3,228
4,257
4,942
7,431
9,933

166.3
190.1
219.2
234.6
288.0
333.4

15
17
19
21
26
30

165.5
148.4
130.8
119.0
97.3
84.5

8.7
11.1
14.6
17.2
25.7
34.3

5.00
7.00
8.00
9.00
10.00

500
700
800
900
1,000

10,176
13,635
15,373
17,125
18,882

209
243
258
273
287

49
56
60
63
66

35
31
29
28
26

23.7
31.6
35.5
39.5
43.4

14,965
20,051
22,607
25,184
27,768

410.0
475.8
505.8
534.5
561.9

36
42
45
47
49

69.3
60.3
57.0
54.2
51.8

51.5
68.7
77.3
85.8
94.4

12.00
15.00
20.00
30.00
35.00

1,200
1,500
2,000
3,000
3,500

22,423
27,788
36,903
55,799
65,548

313
350
405
504
550

72
79
91
111
119

24
22
20
16
15

51.3
63.2
82.9
122
142

32,974
40,865
54,269
82,057
96,394

613.8
685.6
794.8
989.0
1,078.2

54
60
68
83
89

47.8
43.4
38.4
32.3
30.3

112
137
180
266
309

40.00
50.00
60.00
70.00
80.00

4,000
5,000
6,000
7,000
8,000

75,574
96,301
117,917
140,488
163,836

594
679
760
839
916

127
142
155
167
179

15
13
13
12
11

162
201
241
280
320

111,139
141,619
173,407
206,600
240,936

1,164.8
1,330.8
1,490.0
1,645.4
1,796.5

95
106
116
126
134

28.8
26.4
24.8
23.5
22.5

352
438
524
610
695

90.00
9,000
100.00 10,000

187,941
213,119

992
1,067

190
200

11
11

359
399

276,384
313,410

1,944.3
2,092.8

142
150

21.6
21.0

781
867

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15 C. Supercompressibility included.
Meters with 30 rotors have higher Qmax and Qmin values.
* E-Class not available in 100 Bar MAOP.

12" GTS Capacities


Output Drive 1,000 ft.3 / 45 Rotor Angle
Line
Pressure Q max
Q min
Range
(psig)
MSCFH MSCFH Q max/Qmin
0.25
150
5
199
10
250
15
301
20
352
25
404
50
662
75
922
100
1,185
125
1,449
150
1,715
175
1,984
200
2,256
275
3,081
300
3,363
400
4,508
500
5,691
600
6,914
700
8,179
800
9,484
900
10,830
1,000
1,100
1,200
1,300
1,400

12,217
13,643
15,103
16,594
17,959

12" GTS Capacities


Output Drive 10m3 / 45 Rotor Angle

Min. Actual
Flow Rate
MACFH

Press.
Drop In.
W.C.

Line Pressure

0.02
2
0.30
30
0.70
70
1.00
100
2.00
200
3.00
300
5.00
500
7.00
700
8.00
800
9.00
900
10.00 1,000
12.00 1,200
15.00 1,500
20.00 2,000
30.00 3,000
35.00 3,500
40.00 4,000
50.00 5,000
60.00 6,000
70.00 7,000
80.00 8,000
90.00 9,000
100.00 10,000

6.00
6.91
7.75
8.51
9.21
9.86
12.65
14.97
17.00
18.84
24.14
22.13
23.65
27.80
29.12
33.99
38.52
42.82
46.97
51.02
54.98

25
29
32
35
38
41
52
62
70
77
84
90
95
111
116
133
148
161
174
186
197

6.00
5.22
4.66
4.25
3.93
3.68
2.89
2.46
2.19
1.99
2.16
1.72
1.62
1.41
1.36
1.21
1.10
1.03
0.97
0.92
0.89

2.1
2.8
3.5
4.2
4.9
5.6
9.2
12.8
16.3
19.9
23.4
27.0
30.6
41.3
44.8
59.1
73.3
87.6
102
116
130

58.89
62.74
66.53
70.27
73.31

207
217
227
236
245

0.86
0.83
0.81
0.79
0.76

145
159
173
187
202

Bar

kPa

Range Min. Actual Press.

Sm3/h
Q max

Q min

Q max/
Q min

Flow Rate
Am3/h

Drop
mbar

4,289
5,512
7,269
8,438
12,689
16,962
25,554
34,239
38,604
43,004
47,416
56,307
69,782
92,670
140,121
164,603
189,780
241,829
296,110
352,790
411,422
471,954
535,179

171
195
225
240
295
342
420
487
518
548
576
629
702
814
1,013
1,105
1,193
1,363
1,527
1,686
1,841
1,992
2,144

25
28
32
35
43
50
61
70
74
79
82
90
99
114
138
149
159
177
194
209
224
237
250

170
152
134
122
100
87
71
62
58
55
53
49
44
39
33
31
29
27
25
24
23
22
22

5.2
6.7
8.7
10.3
15.4
20.5
30.8
41.0
46.2
51.3
56.4
66.7
82.1
108
159
185
210
262
313
364
416
467
518

Note: Capacity Table values established @ base pressure of 101.325 kPa and
base temperature of 15 C. Supercompressibility included.

Note: Capacity Table values established @ base pressure of 14.73 PSIA and
base temperature of 60F. Supercompressibility included.

3" GTS Basic Specifications

Figure 1 - Horizontal Flow

Horizontal (Figure 1)
Dimensions (Inches)

Vertical (Figure 2)
Dimensions (Inches)

MAOP
(psig)

Material
(See
Note C)

Weight
(lbs.)

275
1,440

AL
ST

9
11.1

6.5
6.5

0.4
0.4

12.2
14.5

9.9
9.9

0.4
0.4

10
20

A
1/4 - 18 NPT

FLOW

C
B

3" GTS (75 mm) Basic Specifications

Bar

kPa

Horizontal (Figure 1)
Dimensions (mm)

Vertical (Figure 2)
Dimensions (mm)

Material
(See
Note C)

Weight
(kg)

AL
ST

229
282

165
165

10
10

310
368

251
251

10
10

4.5
9.0

FLOW

MAOP

Figure 2 - Vertical Flow

1/4 - 18 NPT

19
190
100 1,000

B
C

4" GTS, GTX and E-Class Basic Specifications (Figures 3, 3a)


Flange
Material
(See
Note C)

175
720
1,440

AL
CS
CS

AL
AL
AL

Bolts
Inches

B
E-Class

5.85 14.0
5.85 14.0
5.85 14.0

15.50
15.50
15.50

Dia.
O.D. B.D. No. (In.)

NA 9.00 7.50
0.06 10.00 7.87
0.25 10.75 8.50

8
8
8

5/8
3/4
7/8

ANSI
150 FF
300 RF
600 RF

CartApprox. ridge
Shipping Bolt
Weight Torque
(lb.)
(lb-ft.)
32
150
150

A
INLET

MAOP
psig Body Top

Dimensions
(Inches)

Figure 3 4", 6", 8" GTS/GTX

20
68
90

C
B

4" GTS, GTX and E-Class (100 mm) Basic Specifications (Figures 3, 3a)
Flange
Material
(See
Note C)

MAOP
Bar

kPa

AL
CS
CS

Bolts
Hole
O.D. B.D.
Size
(mm) (mm) No. (mm) ANSI

B
E-Class

356
394
394

NA
1.5
6.5

AL 149 356
AL 149 356
AL 149 356

230
255
275

190
200
216

8
8
8

19
22
25

150 FF
300 RF
600 RF

Approx. CartShipridge
ping
Bolt
Weight Torque
(kg)
(Nm)
14.5
68
68

27
92
122

A
INLET

12 1,200
50 5,000
100 10,000

Body Top

Dimensions
(mm)

Figure 3a 4", 6", 8" E-Class


(typical)

C
B

6" GTS, GTX and *E-Class Basic Specifications (Figures 3, 3a)


Flange
Material
(See
Note C)

MAOP
psig Body Top
175
720
1,440

AL
CS
CS

AL
ST
ST

Dimensions
(Inches)

Bolts
Inches

B
E-Class

6.42 16.0
6.92 18.0
7.25 18.0

16.00
22.50
NA

Dia.
O.D. B.D. No. (In.)

NA 11.00 9.50
0.06 12.50 10.62
0.25 14.00 11.50

8
12
12

3/4
3/4
1

ANSI
150 FF
300 RF
600 RF

CartApprox. ridge
Shipping Bolt
Weight Torque
(lb.)
(lb-ft.)
54
275
275

35
205
300

* E-Class not available in 1440 psig MAOP.

6" GTS, GTX and *E-Class (150 mm) Basic Specifications (Figures 3, 3a)
Flange
MAOP
Bar

kPa

12 1,200
50 5,000
100 10,000

Material
(See
Note C)
Body Top
AL
CS
CS

Dimensions
(mm)
A

B
E-Class

410
572
NA

NA
1.5
6.5

AL 163 410
ST 176 460
ST 188 460

Bolts
Hole
O.D. B.D.
Size
(mm) (mm) No. (mm) ANSI
279
318
356

241
270
292

8
12
12

22
22
29

150 FF
300 RF
300 RF

* E-Class not available in 100 Bar MAOP.

Approx. CartShipridge
ping
Bolt
Weight Torque
(kg)
(Nm)
24.5
125
125

47
278
407

Operating
Temperature Range:
-40F to +140F
-40C to -60C
Manufacturing standards
ANSI/ASME MFC - 4M - 1986
AGA Report #7
Note C:
AL = Aluminum
CS = Cast Steel
ST = Steel
B.D. = Bolt Circle Diameter

8" GTS, GTX and *E-Class Basic Specifications (Figures 3, 3a)


Flange
Material
(See
Note C)

Dimensions
(Inches)
Inches

AL
CS
CS

B
E-Class

AL 7.42
ST 7.92
ST 8.42

21.0
23.0
23.0

21.00
27.25
NA

Dia.
O.D. B.D. No. (In.)

ANSI

NA 13.50 11.75 8 3/4 150 FF


0.06 15.00 13.00 12 7/8 300 RF
0.25 16.50 13.75 12 1-1/8 600 RF

CartApprox. ridge
Shipping Bolt
Weight Torque
(lb.)
(lb-ft.)
90
450
450

A
INLET

MAOP
psig Body Top
175
720
1,440

Bolts

Figure 3 4", 6", 8" GTS/GTX

70
340
500

C
B

* E-Class not available in 1440 psig MAOP.

8" GTS, GTX and *E-Class (200 mm) Basic Specifications (Figures 3, 3a)
Flange
Material
(See
Note C)

MAOP
Bar

kPa

Dimensions
(mm)

Body Top
AL
CS
CS

B
E-Class

535
693
NA

NA
1.5
6.5

AL 188 535
ST 201 585
ST 214 585

345
385
420

298
330
349

8
12
12

22
25
32

150 FF
300 RF
600 RF

47
205
205

Figure 3a 4", 6", 8" E-Class


(typical)
A
INLET

12 1,200
50 5,000
100 10,000

Bolts
Hole
O.D. B.D.
Size
(mm) (mm) No. (mm) ANSI

Approx. CartShipridge
ping
Bolt
Weight Torque
(kg)
(Nm)
95
461
678

* E-Class not available in 100 Bar MAOP.

C
B

12" GTS Basic Specifications (Figure 4)


Flange
Material
(See
Note C)

Bolts

Dimensions
(Inches)

Inches

MAOP
psig

Body

Top

175
275
720
1,440

ST
ST
ST
ST

AL
ST
ST
ST

15.35
15.35
15.85
16.35

29.00
29.00
30.25
32.75

0.06
0.06
0.06
0.25

O.D. B.D. No.

Dia.
(In.)

ANSI

19.00
19.00
20.50
22.00

7/8
7/8
1-1/8
1-1/4

150 FF
150 RF
300 RF
600 RF

17.00
17.00
17.75
19.50

12
12
16
20

CartApprox.
ridge
Shipping
Bolt
Weight Torque
(lb.)
(lb-ft.)
460
490
620
970

Figure 4 12" GTS

75
110
280
630
C
B

12" GTS (300 mm) Basic Specifications (Figure 4)


Flange
MAOP
Bar kPa
12 1,200
19 1,900
50 5,000
100 10,000

Material
(See
Note C)

Dimensions
(mm)

Body

Top

ST
ST
ST
ST

AL
ST
ST
ST

390
390
403
415

740
740
770
832

1.5
1.5
1.5
6.5

Bolts
Hole
O.D. B.D.
Size
(mm) (mm) No. (mm)
483
483
521
559

432
432
451
495

12
12
16
20

25
25
32
35

ANSI
150 FF
150 RF
300 RF
600 RF

10

CartApprox.
ridge
Shipping
Bolt
Weight Torque
(kg)
(Nm)
209
222
280
440

102
149
379
854

Ordering Information
GTS

3"

4"

6"

8"

12"

275 psig/19 bar


1440 psig/100 bar

175 psig/12 bar


720 psig/50 bar
1440 psig/100 bar

175 psig/12 bar


720 psig/50 bar
1440 psig/100 bar

175 psig/12 bar


720 psig/50 bar
1440 psig/100 bar

175 psig/12 bar


275 psig/50 bar
1440 psig/100 bar

MAOP

ROTOR

45 Plastic

45 Plastic
45 Metal
30 Metal

45 Plastic
45 Metal
30 Metal

45 Plastic
45 Metal
30 Metal

45 Plastic

INDEX

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

Low Frequency
Medium Frequency

Low Frequency
Medium Frequency
High Frequency

Low Frequency
Medium Frequency
High Frequency

Low Frequency
Medium Frequency
High Frequency

Low Frequency
Medium Frequency

PULSER

GTX

4"

6"

8"

MAOP

175 psig/12 bar

175 psig/12 bar

175 psig/12 bar

NA

ROTOR

45 Plastic

45 Plastic

45 Plastic

NA

INDEX

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

NA

Low Frequency
Medium Frequency

Low Frequency
Medium Frequency

Low Frequency
Medium Frequency

NA

4"

6"

8"

175 psig/12 bar


720 psig/50 bar
1440 psig/100 bar

175 psig/12 bar


720 psig/50 bar
NA

175 psig/12 bar


720 psig/50 bar
NA

NA

45 Plastic
45 Metal
30 Metal

45 Plastic
45 Metal
30 Metal

45 Plastic
45 Metal
30 Metal

NA

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

None
Circle-Type
Odometer-Type

NA

Low Frequency
Medium Frequency
High Frequency

Low Frequency
Medium Frequency
High Frequency

Low Frequency
Medium Frequency
High Frequency

NA

PULSER

E-CLASS
MAOP

ROTOR

INDEX

PULSER

Direct Equimeter turbine meter


replacement with new E-Class
models.

11

A Complete Family of Gas Measurement, Pressure Regulation, and Testing Systems

Rotary Meter With


Continuous Mechanical
Temperature Compensator

Rotary Meter with Integral


Mercury Corrector

The new CMTC RPM Series gas


meter provides flowing-gas volume
registration continuously and
mechanically corrected to the
standard base temperature (60F).
See bulletin SB 5520 for more
information.

AMC Quality System

ISO 9002 Certified

A new generation of Mercury


Mini-Max and Mini-AT Correctors
now mount integrally to American
Meters RPM Series Rotary Meters.
See bulletin SB 5510 for more
information.

Diaphragm Meters

Pilot-Loaded Regulators

American Meters compact,


lightweight, aluminumcase meters
are designed to provide positive
displacement accuracy for
industrial or commercial loads.
See bulletin SB 3510 for more
information.

1800 PFM industrial regulators are


designed for applications requiring
medium-to-high capacity, extremely
precise outlet-pressure control,
and fast response to changing
loads. See bulletin SB 8551 for
more information.

QMI is Accredited by:

Dutch Council
for Accreditation

Represented by...

YesterdayTodayTomorrow
300 Welsh Road, Building One
Horsham, PA 19044-2234
Phone: 215/830-1800 Fax 215/830-1890
www.americanmeter.com

275 Industrial Road


Cambridge, Ontario
Canada N3H 4R7
Phone: 519/650-1900 Fax 519/650-1717
www.americanmeter.com

Printed in U.S.A.

Core 2500 5/03

American Meter Company has a program of continuous product development and improvement; and, therefore, the information in this bulletin is subject to change or modification without notice.

Das könnte Ihnen auch gefallen