Sie sind auf Seite 1von 17

Cargo Apron

Hyderabad International Airport


Date:

08-08-2006

Designer:

Philips Electronics India Ltd

The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship
to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection
properties and electrical supply.

Central Lighting Design & Appl. Centre


7,Justice Chandra Madhab Road,
Calcutta - 700020

Telephone: 033-24769640
E-Mail: saumen.bhaumik@philips.com

CalcuLuX Area 6.5 RC2

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Table of Contents

1.

Project Description

1.1

Top Project Overview

2.

Summary

2.1
2.2
2.3

General Information
Project Luminaires
Calculation Results

4
4
4

3.

Calculation Results

3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8

Whole apron: Textual Table


Whole apron: Iso Contour
Aircraft stand: Textual Table
Aircraft stand: Iso Contour
Whole Apron without stnd: Textual Table
Whole Apron without stnd: Iso Contour
Aircraft stand_Ver: Textual Table
Aircraft stand_Ver: Iso Contour

5
7
8
10
11
13
14
16

4.

Installation Data

17

4.1
4.2

Legends
Luminaire Positioning and Orientation

17
17

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Page:

2/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

1. Project Description

880

890

900

910

920

930

940

950

960

1.1 Top Project Overview

820
810
670

680

690

700

710

720

730

740

750

760

770

780

790

800

Y(m)

830

840

850

860

870

-840 -830 -820 -810 -800 -790 -780 -770 -760 -750 -740 -730 -720 -710 -700 -690 -680 -670 -660 -650 -640 -630 -620 -610 -600 -590 -580

X(m)

MVF403 CAT-A7
Scale
1:1500

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Page:

3/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

2. Summary
2.1 General Information
The overall maintenance factor used for this project is 0.80.

2.2 Project Luminaires


Code
A

Qty Luminaire Type


8 MVF403 CAT-A7

Lamp Type
1 * MHN-SA2KW400V956

Power (W)
2163.0

Flux (lm)
1 * 200000

The total installed power: 17.30 (kWatt)


Number of Luminaires Per Arrangement:
Luminaire
Code
Arrangement
A
Point
4
Point1
4

Power (kWatt)
8.65
8.65

2.3 Calculation Results


(Il)luminance Calculations:
Type
Calculation
Surface Illuminance
Whole apron
Surface Illuminance
Aircraft stand
Whole Apron without
Surface Illuminance
stnd
Aircraft stand_Ver
Vertical Illuminance

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Unit
lux
lux

Ave Min/Ave Min/Max


28.2
0.27
0.11
25.8
0.29
0.11

lux

29.2

0.26

0.11

lux

45.8

0.55

0.26

Page:

4/17

Cargo Apron

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Hyderabad International Airport

3. Calculation Results
3.1 Whole apron: Textual Table
Grid
Calculation
X (m)
Y (m)
870.00

: Whole Apron at Z = 0.00 m


: Surface Illuminance (lux)

-812.00 -802.00 -792.00 -782.00 -772.00 -762.00 -752.00 -742.00 -732.00 -722.00 -712.00 -702.00 -692.00
10

19

23

11

34

28

31

33

25

23

24

26

36

859.11

19

31

48

68

57

35

46

41

35

32

33

36

44

848.22

34

50

50

47

46

42

45

41

35

32

33

38

44

837.33

38

59

65

55

49

48

41

33

31

30

30

31

32

826.44

38

50

54

50

48

41

33

27

25

25

25

26

28

815.56

29

39

40

37

32

29

25

23

20

21

21

21

23

804.67

23

28

28

27

24

22

19

18

17

16

17

17

17

793.78

17

19

20

19

19

17

16

14

14

13

13

13

13

782.89

12

14

14

14

14

14

12

11

11

11

10

10

11

772.00

10

10

11

10

10

10

Continue >

Average
28.2

Min/Ave
0.27

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80
Page:

5/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

< Continue
Grid
Calculation

X (m)
Y (m)
870.00

: Whole Apron at Z = 0.00 m


: Surface Illuminance (lux)

-682.00 -672.00 -662.00 -652.00 -642.00 -632.00 -622.00


34

34

39

20

30

22

14

859.11

49

33

52

67

51

48

39

848.22

48

41

47

49

72>

70

49

837.33

41

48

46

46

57

69

53

826.44

31

36

38

41

49

53

42

815.56

24

26

25

28

33

33

30

804.67

18

18

18

18

21

21

22

793.78

14

14

13

14

15

16

16

782.89

10

10

10

11

12

12

11

772.00

8<

Average
28.2

Min/Ave
0.27

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80
Page:

6/17

Cargo Apron

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Hyderabad International Airport

3.2 Whole apron: Iso Contour


: Whole Apron at Z = 0.00 m
: Surface Illuminance (lux)

880

890

900

910

920

930

940

950

960

Grid
Calculation

40

850

60

30

40

30

60
70

50
60

50

830

30

820

40

810

30

20

20

790

800

Y(m)

20

60

40

840

20

30

50

860

20

30

870

780

10
10

680

690

700

710

720

730

740

750

760

770

10

-840 -830 -820 -810 -800 -790 -780 -770 -760 -750 -740 -730 -720 -710 -700 -690 -680 -670 -660 -650 -640 -630 -620 -610 -600 -590 -580

X(m)

A
Average
28.2

MVF403 CAT-A7
Min/Ave
0.27

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80

Scale
1:1500
Page:

7/17

Cargo Apron

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Hyderabad International Airport

3.3 Aircraft stand: Textual Table


Grid
Calculation
X (m)
Y (m)
852.00

: Aircraft stand at Z = 0.00 m


: Surface Illuminance (lux)

-761.00 -750.31 -739.62 -728.92 -718.23 -707.54 -696.85 -686.15 -675.46 -664.77 -654.08 -643.38 -632.69
39

44

38

34

34

35

40

47

40

47

54

62

71>

840.57

48

42

35

32

31

32

35

40

50

47

45

58

67

829.14

42

34

27

26

25

27

28

32

38

40

42

50

58

817.71

31

26

23

21

21

22

23

24

27

27

30

35

37

806.29

23

19

19

17

17

17

18

18

19

19

19

22

23

794.86

18

16

15

14

13

14

14

14

14

14

14

16

16

783.43

14

12

11

11

11

10

10

11

10

10

11

12

12

772.00

10

8<

Continue >

Average
25.8

Min/Ave
0.29

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80
Page:

8/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

< Continue
Grid
Calculation

: Aircraft stand at Z = 0.00 m


: Surface Illuminance (lux)

X (m)
Y (m)
852.00

-622.00

840.57

54

829.14

45

817.71

32

806.29

23

794.86

16

783.43

11

772.00

44

Average
25.8

Min/Ave
0.29

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80
Page:

9/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

3.4 Aircraft stand: Iso Contour


: Aircraft stand at Z = 0.00 m
: Surface Illuminance (lux)

880

890

900

910

920

930

940

950

960

Grid
Calculation

40

840

70

820

40

30

810

20
20

780

790

800

Y(m)

50

830

60

30

40

50

850

860

870

10

680

690

700

710

720

730

740

750

760

770

10

-840 -830 -820 -810 -800 -790 -780 -770 -760 -750 -740 -730 -720 -710 -700 -690 -680 -670 -660 -650 -640 -630 -620 -610 -600 -590 -580

X(m)

A
Average
25.8

MVF403 CAT-A7
Min/Ave
0.29

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80

Scale
1:1500
Page:

10/17

Cargo Apron

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Hyderabad International Airport

3.5 Whole Apron without stnd: Textual Table


Grid
Calculation
X (m)
Y (m)
870.00

: Whole Apron without stnd at Z = 0.00 m


: Surface Illuminance (lux)

-812.00 -802.00 -792.00 -782.00 -772.00 -762.00 -752.00 -742.00 -732.00 -722.00 -712.00 -702.00 -692.00
10

19

23

11

34

28

31

33

25

23

24

26

36

859.11

19

31

48

68>

57

35

46

41

35

32

33

36

44

848.22

34

50

50

47

46

42

837.33

38

59

65

55

49

48

826.44

38

50

54

50

48

41

815.56

29

39

40

37

32

29

804.67

23

28

28

27

24

22

793.78

17

19

20

19

19

17

782.89

12

14

14

14

14

14

772.00

10

10

11

10

10

10

Page:

11/17

Continue >

Average
29.2

Min/Ave
0.26

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

< Continue
Grid
Calculation

X (m)
Y (m)
870.00
859.11

: Whole Apron without stnd at Z = 0.00 m


: Surface Illuminance (lux)

-682.00 -672.00 -662.00 -652.00 -642.00 -632.00 -622.00


34

34

39

20

30

22

14

49

33

52

67

51

48

39

8<

848.22
837.33
826.44
815.56
804.67
793.78
782.89
772.00

Average
29.2

Min/Ave
0.26

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80
Page:

12/17

Cargo Apron

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Hyderabad International Airport

3.6 Whole Apron without stnd: Iso Contour


: Whole Apron without stnd at Z = 0.00 m
: Surface Illuminance (lux)

880

890

900

910

920

930

940

950

960

Grid
Calculation

20
60

30

40

30

40

30

50

860

20

30

870

20

60

820
810
780

790

800

Y(m)

830

840

40

850

60

50
60

680

690

700

710

720

730

740

750

760

770

10

-840 -830 -820 -810 -800 -790 -780 -770 -760 -750 -740 -730 -720 -710 -700 -690 -680 -670 -660 -650 -640 -630 -620 -610 -600 -590 -580

X(m)

A
Average
29.2

MVF403 CAT-A7
Min/Ave
0.26

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.11

Project maintenance factor


0.80

Scale
1:1500
Page:

13/17

Cargo Apron

Central Lighting Design & Appl. Centre


Date: 08-08-2006

Hyderabad International Airport

3.7 Aircraft stand_Ver: Textual Table


Grid
Calculation
Height above grid
X (m)
Y (m)
852.00

: Aircraft stand at Z = 0.00 m


: Vertical Illuminance in +Y direction (lux)
: 2.00 m

-761.00 -750.31 -739.62 -728.92 -718.23 -707.54 -696.85 -686.15 -675.46 -664.77 -654.08 -643.38 -632.69
40

41

33

29

28

29

34

44

43

43

50

66

68

840.57

68

52

44

38

37

39

43

49

67

69

64

81

98

829.14

72

56

45

42

40

42

47

54

63

69

75

90

99>

817.71

61

53

46

42

41

42

47

50

56

56

58

72

71

806.29

55

47

44

39

38

40

42

44

47

46

45

53

55

794.86

50

43

40

37

34

36

36

39

38

39

40

45

45

783.43

42

38

35

34

32

31

31

33

32

32

33

36

37

772.00

35

32

31

29

29

26

27

27

26

25<

27

29

30

Continue >

Average
45.8

Min/Ave
0.55

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.26

Project maintenance factor


0.80
Page:

14/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

< Continue
Grid
Calculation
Height above grid

X (m)
Y (m)
852.00

-622.00

840.57

73

829.14

72

817.71

64

806.29

56

794.86

44

783.43

35

772.00

28

: Aircraft stand at Z = 0.00 m


: Vertical Illuminance in +Y direction (lux)
: 2.00 m

40

Average
45.8

Min/Ave
0.55

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.26

Project maintenance factor


0.80
Page:

15/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

3.8 Aircraft stand_Ver: Iso Contour


: Aircraft stand at Z = 0.00 m
: Vertical Illuminance in +Y direction (lux)
: 2.00 m

880

890

900

910

920

930

940

950

Grid
Calculation
Height above grid

850

860

870

60

40

820

60

80

60

810

40

800

Y(m)

830

840

60

680

690

700

710

720

730

740

750

760

770

780

790

40

-840 -830 -820 -810 -800 -790 -780 -770 -760 -750 -740 -730 -720 -710 -700 -690 -680 -670 -660 -650 -640 -630 -620 -610 -600 -590 -580

X(m)

A
Average
45.8

MVF403 CAT-A7
Min/Ave
0.55

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Min/Max
0.26

Project maintenance factor


0.80

Scale
1:1500
Page:

16/17

Cargo Apron
Hyderabad International Airport

Central Lighting Design & Appl. Centre


Date: 08-08-2006

4. Installation Data
4.1 Legends
Project Luminaires:
Code
Qty Luminaire Type
A
8 MVF403 CAT-A7

Lamp Type
1 * MHN-SA2KW400V956

Flux (lm)
1 * 200000

4.2 Luminaire Positioning and Orientation


Qty and
Code

Position

Aiming Angles

X (m)

Y (m)

Z (m)

Rot.

Tilt90

Tilt0

1*A
1*A
1*A
1*A
1*A

-785.00
-785.00
-785.00
-785.00
-650.00

876.00
876.00
876.00
876.00
876.00

30.00
30.00
30.00
30.00
30.00

-94.8
-23.7
-62.5
-112.6
-119.7

73.0
69.2
74.1
66.3
72.2

0.0
0.0
0.0
0.0
0.0

1*A
1*A
1*A

-650.00
-650.00
-650.00

876.00
876.00
876.00

30.00
30.00
30.00

-74.9
-58.5
-156.3

73.9
60.5
68.4

0.0
0.0
0.0

Philips Lighting B.V. - CalcuLuX Area 6.5 RC2

Page:

17/17

Das könnte Ihnen auch gefallen