Sie sind auf Seite 1von 8

Model FB-S

Horizontal
Steam Boiler
60 - 400 BHP

a few of the

Features
Operating Principal
Compact design minimizes Footprint
Seamless tubes 15% thicker than
competitors
Corrugated Furnace
Large Water Content
Generous Heating Surface
Three year pressure vessel warranty

The FB-S is a traditional three-pass horizontal


firetube boiler. The first pass flows through the
furnace from front to back. The furnace is
corrugated to maximize efficiency while also
minimizing thermal stress.
The second and third passes travel through heavy
duty seamless tubes. Flue gasses travel first from
the combustion furnace to the front chamber
forming the second pass. The gases then flow
through the third pass tubes to the back of the
boiler stack and out the exhaust vent, located
conveniently in the back of the boiler.

a wide range of

Applications
Bio-Fuel
Fulton boilers are used in a variety of
applications throughout the industry. Food,
plastic and chemical processing as well as
pharmaceutical and bio-fuel production are
only a few of the many existing applications
using Fulton.

Laundry
Large scale laundry applications rely on Fulton
FB-S boilers every day to provide a steady
supply of steam, which is critical for their
business.

Building Heat
Fulton horizontal boilers can often be found in
many large building heat applications - such as
schools and government buildings - where a
reliable source of heat is crucial.

C
E

Rear stack connection for easy venting.

D
B

Multiple banks of heavy gauge seamless


boiler tubes used in the second and third
flue pass ensure durability.

Water-backed design eliminates heavy


refractory on rear door while increasing
efficiency and reducing radiant heat loss.

Large water volume and generous steam


chamber ensure low sensitivity to load
change and pressure vessel stability.
The combustion chamber is located
below the water level and with enough
clearance from the bottom of the boiler to
allow for optimal water circulation. The
low placement of the combustion
chamber provides an additional buffer
between the furnace and the water level,
providing higher quality steam.

take a look

Inside

Fully modulated oil, gas


or combination burner.
(open protocol)

The large diameter corrugated


combustion chamber provides a generous
heating surface area. This enhances heat
transfer while reducing heat flux.
In addition to reinforcing the overall
strength of the combustion chamber, the
corrugation also increases the longevity of
the pressure vessel. This is due to a
substantial reduction in thermal and
mechanical fatigue caused by cyclical
expansion and contraction.

The large surface area of the burner


initially reduces exit temperatures through
enhanced radiation and convection.
Radiant heat losses from the gas chamber
are then minimized by heavy insulation on
the front door. This also helps to reduce
the temperature of the front door.
The gas chamber is air insulated to reduce
heat exchange loss. Though it is not a part
of the pressure vessel, it does play a
crucial role in the boiler design.

technical

Details
Specifications
Models
Max Operating Pressure *
Steam Output

FB-S

60

100

150

200

250

300

400

BHP
PSI
BAR
LBS/HR
KG/HR

60
150
10.3
2,204
1,000

100
150
10.3
3,306
1,500

150
150
10.3
4,409
2,000

200
150
10.3
6,612
2,999

250
150
10.3
8,816
3,999

300
150
10.3
9,918
4,499

400
150
10.3
13,224
5,998

GPH
LPH
FT3/HR
M3/HR

19
72
2,705
77

28
106
4,058
115

37
140
5,378
153

56
212
8,122
230

75
284
10,806
306

84
318
11,936
338

112
424
15,715
445

IN
MM
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM

2
51
2
51
1.25
32
1.5
38
0.5
13
12
305

2
51
2.5
64
1.25
32
1.5
38
0.5
13
14
356

2
51
3
76
1.25
32
1.5
38
0.5
13
16
381

2
51
4
102
1.25
32
2
51
0.5
13
18
457

2
51
4
102
1.5
38
2
51
0.5
13
20
508

2.5
64
4
102
1.5
38
1.5
38
0.5
13
20
508

3
76
5
127
2
51
2
51
0.5
13
24
610

BHP
KW
BHP
KW

2
1.5
2
1.5

3
2.2
3
2.2

7.5
4.5
7.5
4.5

15
7.5
15
7.5

15
7.5
20
15

15
7.5
20
15

20
15
20
15

Approximate Fuel Usage


Light Oil **
Natural Gas **

Connections
Safety Relief Valve
Steam Outlet (150 lb flange)
Feedwater inlet
Blowdown
Water Column Blowdown
Stack Diameter

Power
Burner Motor (Oil)
Burner Motor (Gas)

* Please consult factory for alternate operating pressures.


** Please consult factory for additional fuel options.
Specifications and Dimensions are approximate. Consult factory for model specific electrical requirements.
We reserve the right to change specifications and/or dimensions without notice.

Dimensions
Models
A. Boiler Length (w/o burner)
B. Boiler Length (w/ burner)
C. Boiler Width (w/ trim)
D. Boiler Height (w/ trim)
E. Door Opening

FB-S

60

100

150

200

250

300

400

BHP
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM

60
131
3,327
173
4,394
67
1,702
77
1,956
32
813

100
143
3,632
185
4,699
70
1,788
80
2,032
34
837

150
161
4,089
207
5,258
83
2,108
92
2,337
36
914

200
188
4,775
234
5,944
86
2,184
98
2,489
36
914

250
195
4,953
246
6,248
86
2,184
100
2,540
43
1,092

300
236
5,994
286
7,264
86
2,184
100
2,540
43
1,092

400
218
5,537
270
6,858
106
2,692
118
2,997
46
1,168

LB
KG
LB
KG
GAL
LITERS

9,460
4,291
14,972
6,791
661
2,500

11,330
5,139
17,827
8,086
779
2,950

14,300
6,486
22,006
9,982
924
3,500

20,240
9,181
31,032
14,076
1,294
4,900

25,564
11,596
38,783
17,592
1,585
6,000

28,786
13,057
44,207
20,052
1,849
6,998

38,126
17,294
56,407
25,586
2,192
8,297

Approximate Weights
Shipping Weight
Operating Weight
Water Content

Specifications and Dimensions are approximate. We reserve the right to change specifications and/or dimensions without notice.

C
E

A
B

The Fulton Companies


3981 Port Street
Pulaski, NY 13142
Call: (315) 298-5121
Fax: (315) 298-6390

www.fulton.com

Fulton is a global manufacturer of steam,


hot water & thermal fluid heat transfer systems.

FB-S IC BRO
051007
Printed in USA