Sie sind auf Seite 1von 16

KoCoS The Technology Group n Where Precision Meets Quality

Innovative Measurement and Technology


n Metering and Power Quality Analysis
n Digital Fault Recording
www.kocos.com

nnnnnEPP

Power Quality Analysis EPPE CX

METER AND POWER QUALITY

EPPE CX
Advance Power Meter &
Power Analyzer

Power Quality Analysis EPPE CX

EPPE CX Whats new?

New design
Improved performance
Increased computing capacity
Various measurement models
Integrated sensor card (PV systems,
wind power plants, industrial plants)

Replaceable measurement data


memory

6 current inputs (differential current


measurement)

Power Quality Analysis EPPE CX

EPPE CX

- Front -

NEW front design

New layout
Advanced display functions
2 additional LEDs
NEW

additional EPPE software

Basic software

Additional expert software

Power Quality Analysis EPPE CX

EPPE C8
Outstanding features of the EPPE C8 include

Intuitive operation with 5" TFT graphica


touch screen
IEC 61850 protocol
Parametrisation via USB stick
Integrated web server
Multi-client capability
2-GB internal flash memory
Multi-processor system

Power Quality Analysis EPPE CX

EPPE C8
Outstanding features of the EPPE C8 include

Integrated energy meter


Numerous communication
interfaces

Direct current measurement


up to 40A

Time synchronisation via GPS, DCF,


NTP, PC-time

12 binary inputs, 8 relay outputs


..

Power Quality Analysis EPPE CX

Application

U1, U2, U3, U (EN)

GPS

Ethernet

Application example: PV system

Sensor card
Light irradiation
Outside temperature
Module temperature
Humidity sensor
DC Current
DC Voltage

I1, I2, I3, IN

Power
Supply

Power Quality Analysis EPPE CX

Application

Application example: Wind power plant


U1, U2, U3, U (EN)
GPS

Sensor card
Wind intensity
Wind direction
Acoustic noise
Rotor oscillation
Generator temperature
UMTS

Outside temperature

I1, I2, I3, IN

Ethernet

Power
Supply

Power Quality Analysis EPPE CX

DIGITAL FAULT RECORDING


SHERLOG CRX
n

Digital fault recording

Fault location

Disturbance recording

Continuous recording

Power quality monitoring

Event recording

Synchrophasor measurement

Sequence of event recording

Real-time monitoring

Power Quality Analysis EPPE CX

Front and Back View- - -POWER SYSTEM RECORDER

Power Quality Analysis EPPE CX


Modules
Device Structure and Modules
Interface module FO
Synchronisation module
CPU module

Relays module
Power supply units

Analog and binary inputs

Power Quality Analysis EPPE CX


Example of Application Time Synchronisation and Interlink interface

DCF 77
Antenne

GPS
Antenne

IRIG-B Eingang

Zeitsync.
Datum/Zeit/PPS

Crosstrigger

SHERLOG
Interlink

Standard

NTP/SNTP

NMEA RMC
PPS/PPM

Glasfaser
GPS Eingang
Elektrischer
GPS Eingang

IRIG-B Eingang

NTP/SNTP
Zeitsync.
Datum/Zeit/PPS

Crosstrigger

Kriterium/Quelle

SHERLOG
Interlink

NMEA RMC

NMEA RMC

IRIG-B Eingang

NTP/SNTP
Zeitsync.
Datum/Zeit/PPS

Crosstrigger

Kriterium/Quelle

Kriterium/Quelle

SHERLOG
Interlink
Crosstrigger
Kriterum/Quelle

Coaxial Leitung
Ethernet

Glasfaser-Ring

Zeitsync.
SHERLOG
Interlink
Crosstrigger
Datum/Zeit/PPS

Kriterum/Quelle

SHE

SHE

NTP/SNTP
Zeitsync.
Datum/Zeit/PPS

Crosstrigger
Kriterum/Quelle

SHERLOG
Interlink

Optional

Zeitsync.
Datum/Zeit/PPS

NTP/SNTP
Optional

SHE

NTP/SNTP
Optional

2-Draht Leitung

SHERLOG
Interlink

zu weiteren SHERLOGs

Glasfaser Leitung
4-Draht Leitung

Elektrischer
GPS Eingang

PPS/PPM

Zweidraht-Bus

Legende

Glasfaser
GPS Eingang

PPS/PPM

SHERLOG CRX

Elektrischer
GPS Eingang

PPS/PPM

Optionales Synchronisationsmodul

PPS/PPM

NMEA RMC

Interner GPS
Empfnger

Standard

NMEA RMC

Glasfaser
GPS Eingang

Interner DCF 77
Empfnger

SHERLOG CRX

PPS/PPM

Optionales Synchronisationsmodul

NMEA RMC

Interner GPS
Empfnger

Standard

Interner GPS
Empfnger

Interner DCF 77
Empfnger

SHERLOG CRX

Interner DCF 77
Empfnger

Externe GPS Uhr

Optionales Synchronisationsmodul

GPS
Antenne

Power Quality Analysis EPPE CX


Analog Module with 8 Universal Inputs Example of Application
L1

L2

L3

PE

k1

l1

k2

R
X1

1+

U1

1-

2+

U2

2-

3+

U3

3-

4+

4-

UEN

5-

I1

SHERLOG CRX Analogmodul mit 8 Universaleingngen

k3

X2

5+

l2

X3

6-

I2

k4

X4

6+

l3

X5

X6

7+

7-

I3

l4

X7

X8

8+

8-

IN

Power Quality Analysis EPPE CX


Analog Module with 4 Current Inputs

4-channel current module

4 high-current inputs

3 selectable measuring ranges per input

Measuring ranges:

10 A
40 A
200 A

Power Quality Analysis EPPE CX


Concept

SHERLOG Operating Software

Features

All applications in one software package

Configuration of the measuring system


Automatic device and data handling
Evaluation and report creation
Maintenance and commissioning tools

Clearly designed user interface

Can be operated intuitively


Short familiarisation period
Enables users to work effectively

KoCoS The Technology Group n Where Precision Meets Quality


Power Quality Analysis EPPE CX

Thank you for your attention.

www.kocos.com

Das könnte Ihnen auch gefallen